SCAN 65-1, 65-2, 65-6, 65-7, 65-8 Assembly And Instruction Manual

...
Page 1
SCAN A/S-DK-5492 VISSENBJERG
Product registration number
Scan 65-series
ASSEMBLY- AND INSTRUCTIONS MANUAL
Please indicate the product registration number at any enquiry
GB
Congratulations on your new Scan wood-burning stove
pleasure with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.
Page 2
2
Table of contents
Technical data ........................................................................................................ 3
Installation Safety Technical data and dimensions Dimension sketch Type plate Product registration number Additional accessories Loose parts
Assembly ................................................................................................................9
Remove packaging Positioning your wood-burning stove Distance to furniture Distance to flammable materials, shown with insulated flue pipe Distance to flammable materials, shown with un-insulated flue pipe Distance to firewall Height adjustment of stove Load bearing foundation Floor plate Existing chimney and pre-fabricated element chimney Connection between stove and steel chimney Requirements for chimney Connection with 90° elbow pipe Connecting piece / top outlet Connecting piece / rear outlet Fitting the natural stones Fresh air intake Closed combustion system Indicator for control of air supply Scan 65 open plinth
Accessories ...........................................................................................................20
Heat accumulating stones Fitting the top plate of natural stones
Instruction for use ................................................................................................21
CB technique Primary air Secondary air Baffle plates Ash drawer Handle for riddling grate
Instructions for heating ...................................................................................... 22
The Clean Air Act 1993 Lighting Handling fuel
Maintenance ........................................................................................................ 24
Troubleshooting ..................................................................................................26
CONTENTS
Page 3
3
TECHNICAL DATA
Installation
The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regu­lations as well as the information provided in this Assembly and Instruction Manual.
When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning.
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
The Scan 65-series consists of:
Safety
Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
Scan 65-1
Steel sides
Scan 65-2
Steel sides and side windows
Scan 65-1 LB
Steel sides
Scan 65-2 LB
Steel sides and side windows
Scan 65-3
Natural stones
Scan 65-4
Natural stones and side windows
Scan 65-5
Steel sides, baking oven
Scan 65-6
Steel sides, baking oven and side windows
Scan 65-7
High Top, natural stones
Scan 65-8
High Top, natural stones and side windows
Scan 65-9
High Top, steel sides
Scan 65-10
High Top, steel sides and side windows
Page 4
4
senotherm
30 cm
65-1 /2 ca. 123 kg
65-3 ca. 180 kg
65-4 ca. 168 kg
65-5/6 ca. 162 kg
65-7 ca. 258 kg
65-8 ca. 246 kg
65-9/10 ca. 162 kg
144 mm
148 mm
65-1, 65-3, 65-5, 65-7 & 65-9
0,08
975
< 20
104
82
110
A+
6
221
300
5
12
15-18
13,3
2
1,5
65-2, 65-4, 65-6, 65-8 & 65-10
0,1
1221
< 20
117
79
106
A
6
240
305
6
12
15-18
12,5
2
1,5
4
TECHNICAL DATA
Technical data Unit
CO Emission at 13% O2 %
CO Emission at 13% O2 mg/Nm3
Dust @ 13% O2 mg/Nm3
Nox @ 13% O2 mg/Nm3
Efficiency %
Energy efficiency index
Energy efficiency class
Nominel output kW
Chimney temperature EN 13240 °C
Temperature in connecting piece °C
Amount of smoke g/sek
Sub-pressure EN 13240 Pa
Recommended sub-pressure in connecting piece Pa
Required combustion air supply Nm3/h
Fuel Wood
Fuel consumption kg/h
Amount of fuel kg
Technical data Unit
CO Emission at 13% O2 %
CO Emission at 13% O2 mg/Nm3
Dust @ 13% O2 mg/Nm3
Nox @ 13% O2 mg/Nm3
Efficiency %
Energy efficiency index
Energy efficiency class
Nominel output kW
Chimney temperature EN 13240 °C
Temperature in connecting piece °C
Amount of smoke g/sek
Sub-pressure EN 13240 Pa
Recommended sub-pressure in connecting piece Pa
Required combustion air supply Nm3/h
Fuel Wood
Fuel consumption kg/h
Amount of fuel kg
Test in compliance with EN 13240
Technical data and dimensions
Materials Steel plate, cast iron,
galvanised sheet, vermicolite
Surface treatment
Max. wood length
Weight
Weight
Weight
Weight
Weight
Weight
Weight
Connecting piece internal diameter
Connecting piece external diameter
Approval type Intermittent fuelling*
*Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refueling.
This stove is produced in accordance with type approval for the product, which also covers the product’s Assembly and Instruction Manual.
The Declaration of Performance (DoP) is available from www.scan.dk
Page 5
5
65-5, 65-6, 65-7, 65-8, 65-9 & 65-10
65-1, 65-2, 65-3 & 65-4
A-A ( 1 : 10 )
Top
Bund
1
1
3
2
490
2
1
0
*
*
*
*
7
2
1
0
1
2
*
1
1
1
1
*
*
3
8
0
1
9
0
154
1
1
4
9
0
*
*
*
A-A ( 1 : 10 )
Bund
2
1
0
*
*
*
*
7
2
1
0
1
2
*
1
1
1
1
*
*
154
9
0
*
*
*
A-A ( 1 : 10 )
Bund
154
1
1
4
9
0
*
*
*
A-A ( 1 : 10 )
Top
Bund
3
8
0
1
9
0
1
1
4
9
0
*
*
*
A-A ( 1 : 10 )
Top
Bund
1
1
4
9
2
*
*
*
3
8
2
1
9
2
A-A ( 1 : 10 )
Bund
154
1
1
4
9
2
*
*
*
A-A ( 1 : 10 )
Top
Bund
1
4
3
3
490
154
1
1
4
9
2
*
*
*
1
5
8
2
1
0
*
*
*
*
1
0
9
8
*
1
4
1
5
*
*
3
8
2
1
9
2
1433 (65-5/6 + 9/10)
1448 (65-7/8)
Bund
154
1
1
4
9
2
*
*
*
1
5
8
2
1
0
*
*
*
*
1
4
1
5
*
*
A-A ( 1 : 10 )
Top
Bund
154
1
1
4
9
2
*
*
*
3
8
2
1
9
2
65-9/10
1415** (65-5/6)
1201** (65-7/8)
1196** (65-9/10)
5
TECHNICAL DATA
Dimension sketch
* Centre rear outlet
** Height to the begin­ ning of the connecting piece at top outlet
*** Fresh air intake bottom
**** Fresh air intake at the back of the stove
Page 6
6
65-1 LB & 65-2 LB
490
1
0
0
0
1
2
1
5
0
9
7
9
8
8
0
154
1
1
4
9
0
1
9
0
3
8
0
1
2
1
5
0
9
7
9
8
8
0
154
1
1
4
9
0
154
1
1
4
9
0
1
1
4
9
0
1
9
0
3
8
0
6
6
TECHNICAL DATA
* Centre rear outlet
** Height to the begin­ ning of the connecting piece at top outlet
*** Fresh air intake bottom
**** Fresh air intake at the back of the stove
Dimension sketch
* Centre rear outlet
** Height to the begin­ ning of the connecting piece at top outlet
*** Fresh air intake bottom
**** Fresh air intake at the back of the stove
Dimension sketch
Page 7
6
Scan 65-1 - 65-3 - 65-5 - 65-7 - 65-9
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 Dop 90065600
Wood
Intermittent
EUR
Norway
Classification
Intermittent
Certificate/Standard
EN 13240
Approved by
RWE Power AG
Teknologisk Institut
Dust at 13% O2: < 20 mg/Nm³ Flue gas temperature: 300°C Nominal heat output: 6 kW Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 350 mm - Back: 150 mm - Front: 1000 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 05-2015
0,08% 975 mg/Nm³
Schweiz
Germany
RWE Power AG RWE Power AG
Scan 65-2 - 65-4 - 65-6 - 65-8 - 65-10
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 Dop 90065601
Wood
Intermittent
EUR
Norway
Classification
Intermittent
Certificate/Standard
EN 13240
Approved by
RWE Power AG
Teknologisk Institut
Dust at 13% O2: < 20 mg/Nm³ Flue gas temperature: 305°C Nominal heat output: 6 kW Efficiency: 79%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 500 mm - Back: 150 mm - Front: 1000 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 05-2015
0,10% 1221 mg/Nm³
Schweiz Germany
RWE Power AG RWE Power AG
65-2, 65-4, 65-6, 65-8 & 65-10
65-1, 65-3, 65-5,65-7 & 65-9
6500000
7
TECHNICAL DATA
(With side windows)
(Without side windows)
Type plate
Product registration number
Type plate
All Scan wood-burning stoves are fitted with a type plate that speci­fies the approval standards and the distance to flammable materials.
The type plate is located at the rear of the stove.
Product registration number
All Scan wood-burning stoves are provided with a product registra­tion number. You will always need to quote this number when con­tacting your dealer or Scan A/S.
The product registration number is located at the rear of the stove.
Page 8
7
8
TECHNICAL DATA
Additional accessories
• Small shaped floor plate in glass or steel
• Large shaped floor plate in glass or steel
• Natural stones top plate for stove with rear outlet
• Natural stones top plate for stove with top outlet
• Heat accumulating stones (Scan 65-7, 65-8, 65-9 & 65-10)
Loose parts
The loose parts are located in the stove's ash drawer.
Scan 65, all types:
• Glove
• Seal
• 4 pcs. screws for fastening the connecting piece
• 1 pcs. indicator for control of air supply
• 1 pcs. screw M5x6, must be placed for United Kingdom.
Scan 65-3 and 65-4:
• 4,5 m gasket
Scan 65-7 and 65-8:
• 7 m gasket
Disposal of packaging
Your Scan stove may come supplied with the following packaging:
WOOD PACKAGING:
The wood packaging can be reused and after final use can be inciner­ated as a CO2 neutral product or sent for recycling.
FLAMINGOTOP:
Send for recycling or waste disposal.
FOAM:
Send for recycling or waste disposal.
PLASTIC BAGS:
Send for recycling or waste disposal.
STRETCH FILM/PLASTIC FILM:
Send for recycling or waste disposal.
Page 9
8
9
Screws to be removed
Remove the screws securing the stove to the pallet.
Fit the plastic plugs from the service box into the transport protection holes.
Remove the protection between the baffle plates, before taking the stove into use!
Protection for baffle plates
Put back the upper plate on the pins, as the protection pushes the plate upwards.
Pin for baffle plate
ASSEMBLY
Removal of packaging
Check that the stove is not damaged before starting to install it.
The stove comes attached to a wooden pallet on delivery.
Page 10
50
500
250
250
778
5
3
6
745
240
513
50
350
2
5
3
595
240
50
50
313
578
9
65-2, 65-4, 65-6, 65-8 & 65-10
65-1, 65-3, 65-5,65-7 & 65-9
10
ASSEMBLY
Distance to flammable materials, shown with insulated flue pipe
(With side windows)
Without side windows)
Positioning your wood-burning stove
The stove must be set up so that the stove itself, the flue pipe, and the chimney can all be cleaned.
Distance to furniture: 1000 mm
You should however assess whether furniture or other items might become excessively dry due to being too close to the stove.
National and local regulations governing safety distances for wood­burning stoves must be complied with.
If the stove is to be connected to a steel chimney, the chimney require­ments in terms of safety distances must be met.
Distance to flammable materials
These distances apply for an uninsulated flue pipe/insulated flue pipe, all the way down to the stove, having a minimum of 30 mm insulation.
Page 11
150
500
5
3
6
250
778
250
340
745
513
150
350
340
595
100
363
628
100
3
2
4
10
65-2, 65-4, 65-6, 65-8 & 65-10 65-1, 65-3, 65-5,65-7 & 65-9
11
ASSEMBLY
Distance to flammable materials, shown with un-insulated flue pipe
(With side windows)(Without side windows)
Page 12
50
50
100
50
50
700
700
960
700
700
2
53
50
50
100
50
50
700
700
700
800
760
700
860
860
100
100
50
300
50
3
2
4
11
65-2, 65-4, 65-6, 65-8 & 65-10
65-1, 65-3, 65-5,65-7 & 65-9
12
ASSEMBLY
Flammable material
Firewall
Flammable material
Firewall
(With side windows)
Without side windows)
Distance to firewall
110 mm brick or other material with a corresponding insulation ability.
The distances presuppose the use of an insulated flue pipe with min. 30 insulation all the way to the stove.
Page 13
12
13
ASSEMBLY
Large shaped floor plate in glass or steel
Ajustment screw
IT IS VERY IMPORTANT THAT THE STOVE IS LEVEL TO ALLOW AN OPTIMAL FUNCTION OF THE DOOR. PLEASE NOTE THAT ONCE MOUNTED THE STOVE CAN NO LONGER BE ADJUSTED!
Small shaped floor plate in glass or steel
Height adjustment of stove
The stove has four adjustment screws under the stove. Use the adjust­ment screws to get the stove to stand straight and level.
Load-bearing subsurface
All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any reinforcement of the beam structure. They can be positioned on ordinary beams/ floor.
However, you should make sure that the load bearing underlay can bear the weight of the wood-burning stove and that of the chimney.
Floor plate
If you are erecting the stove on a flammable floor, you must comply with the national and local regulations on the size of any non-flam­mable subsurface required to cover the floor around the stove.
Your local Scan dealer can advise you on regulations concerning pro­tection of flammable materials in the vicinity of your stove.
The floor plate’s function is to protect the floor and flammable mate­rial against any sparks that may occur.
A floor plate can be made of steel or glass, but the stove can also be erected on clinker concrete, natural stone or similar materials.
This Scan wood-burning stove has an integrated floor plate at the bot­tom and can thus be erected directly on flammable material without the need for further protection underneath the stove.
Page 14
13
14
ASSEMBLY
Connecting piece
Ceramic asket
Mount the ceramic gasket on the connecting piece
Lift the top plate and connecting piece off the stove.
Existing chimney and pre-fabricated element chimney
If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chimney sweep, for advice. These experts will also let you know if your chimney needs renovating.
When connecting a pre-fabricated element chimney, follow the manu­facturer’s connection instructions for the relevant chimney type.
Connection between stove and steel chimney
Your Scan dealer, or local chimney sweep, can advise you on choos­ing a make and type of steel chimney (we recommend using JØTUL’s chimney system). This ensures that the chimney will match your wood-burning stove. As a general rule, the length of the chimney should not be less than 4 metres, measured from the top of the stove.
Specific weather or installation conditions might require a different length.
Choosing the wrong length or diameter of steel chimney could im­pair functionality.
Always observe the chimney vendor‘s instructions precisely.
Requirements for chimney
The chimney must be labelled T400 and G for soot testing.
Connecting piece / top outlet
The stove is prepared from the factory for top outlet.
The connecting piece is placed loosely in the top outlet of the stove.
The gasket for the connecting piece and the screws for fastening the connecting piece are in the stove’s ash drawer.
Page 15
14
15
ASSEMBLY
Connecting piece
Ceramic asket
Fasten the connecting piece with screws from the ash drawer and replace the top plate.
4 pcs. M5X10 mm screw
Connection piece / rear outlet
The stove is prepared from the factory for top outlet.
The connecting piece is placed loosely in the top outlet of the stove. The gasket for the connecting piece and the screws for fastening the connecting piece are in the stove’s ash drawer.
Lift the top plate and connecting piece off the stove.
Page 16
15
16
ASSEMBLY
Cut off the cover plate from the rear plate with cutting pliers at the fastening points.
Fastening points
Lift the heat shield off the stove and cut the cover plate free using cutting pliers at the fastening points and remove.
Page 17
16
17
ASSEMBLY
4 pcs. M5X10 mm screw
Fit the cover and tighten it. Replace the top plate.Remove the cover. This is to be used later as a seal and cover at the
top of the smoke outlet.
Fit the connecting piece with the four screws found in the stove’s ash drawer. Hook the heat shield onto the stove.
Cover plate
Page 18
17
=
65-3 65-4
65-7 65-8
18
ASSEMBLY
The delivered gasket (4,5/7 m) should be cut in appropiate lengths and sticked onto the sides of the stove as shown below.
Gasket
Fitting the natural stones
Some of the stoves are delivered with loose natural stone plates for mounting on the sides of the stove.
It is a natural material, wherefore there might be differences in struc­ture and form.
Each natural stone must be mounted with distance bushings and screws which are already mounted in the stones.
Page 19
18
19
ASSEMBLY
Hook the natural stone sides onto the stove.
Remove the cover plate at the back of the stove or the cover plate at the bottom of the wood compartment store, as shown on page 15. Connect outside air to the connection piece underneath the com­bustion chamber.
External combustion air via floor
External combustion air via wall
Fresh air intake
In a well-insulated house the air used for the combustion process has to be replaced. This particularly applies to houses with mecha­nical ventilation. There are different ways of making sure that air is exchanged. The most important thing is to ensure that there is a sup­ply of air to the room where the wood stove is located. The external wall vent must be located as close to the wood stove as possible, and you must be able to close it when you are not using the stove.
National and local building regulations must be followed with regard to connection of a fresh air intake.
Closed combustion system
You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home. External combustion air is connected through a ventilation pipe via the wall or floor.
It must be possible to shut off the ventilation pipe with a valve, when the stove is not in use. Minimum Ø100 mm ventilation pipe, maxi­mum length: 6 meters with a maximum of one bend.
If you want external combustion air via a wall, remove the cover plate at the rear of the stove with a pair of cutting pliers. See the procedure in this manual.
If the external combustion air is connected at the rear, the dis­mounted plate must be mounted on the hole for external air in the bottom of the stove.
NOTE: if the stove has a fresh air connection or closed combustion,
the ventilation pipe must be open, when the stove is in use.
Page 20
19
65-9 & 65-1065-7 & 65-8
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 68\90068058.idw
90068058
klargøring til vægbeslag
12-05-2015
hms
Scan 68
VÆGT:
AREAL:
N/A
N/A
20
ASSEMBLY / ACCESSORIES
Cover plate to be removed
Do not remove the radiation plate
The vent for adjustment of the convection air is placed at the back of the high top
ClosedOpen
Cut off this plate from the heat shield in order to make place for the heat accumulating stones
Open plinth
If you want open plinth, remove the wood compartment door and its stop as well as the large cover plate at the back of the stove.
Heat-storage stone
Heat-storage stones are made from a special material with a high heating capacity. The stones are heated up during the firing and gives off the heat again after the firing, which means that the stove stays warm for a longer time.
Firing with the vent open will give a quicker heating. Firing with the vent closed will extend the heating time of the stove.
Fitting the natural stone top
You can buy a natural stone top as an accessory. Place the stone top on the steel top plate
Page 21
0%-100%100%-0%
20
21
Baffle plates
The baffle plates are located in the upper part of the combustion chamber. The plates hold back smoke, making sure it stays inside the combustion chamber for a longer time before escaping through the chimney. This reduces the flue gas temperature as the gases have more time to dissipate heat to the stove. The baffle plates must be removed for sweeping; see “Maintaining your wood-burning stove”. Note that the baffle plates are made of porous, ceramic material, and are liable to break easily. You should therefore handle them with care. The baffle plates are subject to wear and tear and not covered by the warranty.
Ash container
Open the door of the stove to access the ash container under the combustion chamber.
The ash container must always be closed during operation.
The ash container must not be become too full and must therefore be emptied at regular intervals.
Handle for riddling grate
The stove is equipped with a riddling grate that empties ash from the combustion chamber down into the ash container when activated.
The riddling grate must remain half open while the wood stove is lit.
Primary air
Secondary air
Handle for riddling grate
Ash drawer
Adjustment of air supply,
primary and secondary damper
CB-technique
Baffle plates
INSTRUCTIONS FOR USE
IMPORTANT!
This screw (M5X6) must be placed as shown in the picture,to prevent secondary air control closure beyond the 35mm open position .
A
CB technology (Clean Burn)
The stove is equipped with CB technology. In order to ensure optimal combustion of gases released during the combustion process, air pas­ses through a specially developed system of channels. The heated air is conducted into the combustion chamber through the holes in the rear lining of the combustion chamber and at the baffle plates. This airflow is driven by the combustion rate and cannot be regulated.
NOTE: Wood must never be added above the CB rail.
Primary air
The primary air regulation mechanism is used for lighting the fire, or to boost the burning process when you put wood on. The primary air vent is used when you use hard wood fuel such as oak and beech. The primary air vent can be closed if you use soft wood such as birch or pine for fuel.
Settings for normal load: 0-30%
Settings for normal load: 50-70%
Secondary air
Secondary air is pre-heated and fed indirectly to the fire. At the same time, the secondary airflow cleans the glass pane to prevent build-up of soot. If you over-restrict the secondary airflow, soot can build up on the glass pane. The secondary airflow determines the heat output from your stove.
Page 22
21
22
INSTRUCTIONS FOR HEATING
INSTRUCTIONS FOR HEATING
Environmentally-friendly firing
Avoid turning down your stove to the point where no flames are visible from the wood, as this leads to poor combustion and low effi­ciency. The gases released from the wood will not be burnt off due to the low temperature in the combustion chamber. Some of the gases will condense in the stove and flue system as soot, and this could lead to your chimney catching fire at a later point. The residual smoke which exits the chimney will pollute the surrounding area and cause an unpleasant smell.
Lighting
We recommend the use of fire lighters, or similar products, which are available from your Scan dealer. Using fire lighters helps light the wood more quickly and keeps the combustion process clean.
Never use liquid lighting fuels!
“Top down” lighting
4 pieces of wood approx. 20-25 cm long with a weight of approx. 0.4-0.5 kg per piece.
15-20 thin pieces of firewood of about 20 cm in length, with a total weight of approx. 0.8 kg.
4 fire lighters in bag or block form
Place the pieces of wood, firewood and fire lighters in the
combustion chamber.
Set the primary and secondary airflow controls to maximum for the entire lighting phase.
"Top down" lighting is a more environmentally-friendly way of lighting the fire and helps to keep the glass area as clean as possible.
Continuous firing
It is important to obtain as high a temperature as possible in the combustion chamber. This results in best possible use of the stove and fuel, as well as achieving clean combustion. In this way you will avoid build-up of soot on the combustion chamber lining and glass pane. During operation, you should not see any smoke; just a movement in the air that indicates combustion is in progress.
¬ After completing the lighting phase, you should have a good layer of embers in the stove; you can then start operation of it proper. Add two pieces of wood at a time: they should be about 0.6 to 0.8 kg in weight and about 25 cm long.
NOTE: The wood must catch fire quickly; this is why we recommend setting the primary airflow fully open. Operating the stove at too low a temperature and with too little primary air can lead to gases igniting, which can damage the stove.
¬ When adding wood, always open the glass door carefully to prevent smoke escaping.
¬ Never add wood while the fire is burning nicely.
Firing in the spring or autumn
In the spring/autumn transition period, where there is less need for heating, we recommend you light the stove “top down” once, perhaps adding just two pieces of wood as above to ensure that the combu­stion chamber lining burns clean again.
The function of the chimney
The chimney is the wood-burning stove’s motor; its performance determines how well your stove will work. The draught in the chimney creates negative pressure in the wood-burning stove. The negative pressure draws the smoke out of the stove and takes in air through the combustion air damper to fuel the combustion process. Combustion air is also used for the air wash system that keeps the window clear of soot.
The draught in the chimney is created by the difference in tempera­ture inside and outside the chimney. The higher temperature diffe­rence, the better draught. This is why it is important that the chimney reaches operating temperature before you reduce the damper set­tings to restrict combustion in the stove (a brickwork chimney will take longer to reach operating temperature than a steel chimney). It is very important that the operating temperature is reached as quickly as possible on days when the draught in the chimney is poor due to unfavorable wind and weather conditions. You need to get a few flames going as quickly as possible. Chop the wood extra thin; use an extra fire lighter etc.
After longer periods without use, you must check the chimney flue for blockages.
You can connect several units to the same chimney. You should however first check the relevant regulations in this respect.
Using your stove in various weather conditions
The way the wind affects the chimney can have a big impact on how your stove reacts under various wind loads; you may need to adjust the airflow to achieve good combustion. Fitting a damper in the flue pipe may also help, as it will allow you to regulate the draught under changing wind loads. The damper must not close more than 80% of the surface.
Fog and mist can also have a big impact on chimney draught; you may need to use other settings for the combustion air to achieve good combustion.
General notes
note: Parts of the wood-burning stove, especially the outer surfaces, become hot during use. Due care should be exercised.
¬ Never empty ashes into a flammable container. Ashes can contain glowing embers long after you finish operating the stove. When the stove is not in use you can close the dampers to avoid a draught through the stove.
¬ If the stove has not been used for some time, you should check the flue passageways for potential blockages before relighting.
Chimney fire
In the event of a chimney fire, keep the stove door, the ash container, and all dampers on the stove closed. In an emergency, call the fire service.
We recommend that you get a chimney sweep to check the chimney before using the stove again.
Page 23
22
23
INSTRUCTIONS FOR HEATING
Fire starters
1.
2.
3.
4.
Handling fuel
Selecting wood/fuel
You can use any type of wood as fuel. However harder woods, such as beech or ash, are generally better for heating, as they burn more evenly and create less ash. Other woods, such as maple, birch and spruce, are excellent alternatives.
Preparation
The best fuel is obtained where the tree has been felled and the wood sawn and split before May 1st. Remember to cut the wood to match the size of the combustion chamber. We recommend a diameter of 6-10 cm. The length should be about 6 cm shorter than that of the combustion chamber to leave enough space for air to circulate. If the diameter of the wood is greater than the above, it should be split down its length. Wood that has been split dries faster.
Storing
You need to store the sawn and split wood in a dry place for 1-2 years before it will be dry enough to burn. Wood dries faster if you stack it in an airy place. Before using it, it is a good idea to store the wood for a few days at room temperature. Remember that wood absorbs moisture from the air during autumn and winter.
Moisture
To avoid problematic impact on the environment and to ensure opti­mum operating economy, the wood should be perfectly dry before it can be used as fuel. Maximum wood moisture content should not exceed 20%. A moisture content of 15-18% will deliver best efficiency. An easy way of checking wood moisture content is to knock the ends of the two pieces of wood together. If the wood is moist, the sound will be slightly muffled.
If you use wood that is too damp, most of the heat it produces will be used up in evaporating the water. The stove will accordingly not increase in temperature, nor emit heat to the room as a result. This is obviously poor economy, and it will cause soot build-up on the glass pane, in the stove and in the chimney. Operation using moist wood also pollutes the environment.
Understanding the terms used to designate quantities of wood
Various terms are used to designate quantities of wood. Before you buy wood, it makes sense to familiarize yourself with these terms. There are various brochures, in public libraries for example, that cover this topic.
Use of the following as fuel is illegal
Painted, pressure impregnated, or glued wood, or sea driftwood. Nor should you ever burn chipboard, plastics, or treated paper. These contain substances which are hazardous to human health, to the environment, your stove, and your chimney. In short – make sure you only use proper wood.
Calorific value of the wood
The various woods have different calorific values. In other words, for certain species of wood, you will need to use a greater quantity to achieve the same heating performance. This Instruction Manual assumes that you will be using beech, which has a very high calorific value and is also the easiest wood to buy. If you use oak or beech as fuel, you need to bear in mind that these woods have a greater calori­fic value than, say, birch. To avoid any risk of damage to the stove, you should therefore make sure you use less fuel in these cases.
Wood types Kg Dry wood/m3 Compared to beech
Hornbeam 640 110% Beech/Oak 580 100% Ash 570 98% Maple 540 93% Birch 510 88% Pine 480 83% Fir 390 67% Poplar 380 65%
Calorific value of the wood
Page 24
23
24
MAINTENANCE
Maintainance
Apart from having the chimney swept, your wood-burning stove does not require any regular maintenance. However, we do recommend servicing at least once every two years.
Only use original spare parts for maintenance and repair of your stove.
Make sure the stove is cold before starting maintenance or repair work.
Painted surfaces
Clean your wood-burning stove by wiping it down with a dry, lint-free cloth. If the paint finish gets damaged, you can purchase repair paint in spray form from your Scan dealer. As slight differences in color shade are possible, we recommend you spray a larger area to achieve a natural blend. For best results, apply repair spray when the stove is warm enough for you to just keep your hand on it, but no hotter.
Cleaning the glass
Our wood-burning stoves are designed to prevent serious soot build­up on the glass. The best way to achieve this is to make sure you have a good supply of combustion air. It is also very important that the wood is dry and the chimney correctly dimensioned.
Even if you operate the stove in accordance with our instructions, a slight film of soot may still accumulate on the glass. You can easily remove this film by wiping the glass down with a dry cloth and then with a cloth dampened with glass cleaner.
• The glass cleaner is not to get into contact with the gaskets, as this can discolor the glass permanently.
Combustion chamber lining
Slight cracks can appear in the combustion chamber lining due to moisture or sudden heating/cooling. These cracks have no influence on the output or lifetime of your stove. However, if the lining starts to crumble and fall out, you must replace it. The combustion chamber lining is not covered by the warranty.
Seals
All wood-burning stoves have seals made of ceramic material fitted to the stove, the door and/or the glass. These seals are subject to wear and tear and must be replaced when necessary.
Seals are not covered by the warranty.
Sweeping the chimney and cleaning stove
Follow national and local regulations for sweeping the chimney. We recommend having the stove cleaned regularly by a chimney sweep. Before cleaning the stove and sweeping the flue pipe and chimney, we recommend removing the baffle plates.
Checking the stove
Scan A/S recommends that you check your stove thoroughly after sweeping/cleaning. Check all visible surfaces for cracks. Check that all joints are tight and that the gaskets are correctly seated. Worn or deformed gaskets should be replaced.
Servicing
We recommend that the stove is thoroughly serviced at least once every two years by a qualified fitter. The service should include the following:
Lubricate hinges using copper grease.
Check the gaskets. Replace any that are broken or have gone soft.
Check the combustion chamber bottom and riddling grate.
Check heat-insulating materials.
Page 25
A
24
65-2, 65-4, 65-6, 65-8 & 65-10 65-1, 65-3, 65-5, 65-7 & 65-9
25
MAINTENANCE
Upper baffle plate
Lower baffle plate
(without side windows)(with side windows)
Upper baffle plate
Holder for upper baffle plate
Service
Baffle plates and combustion chamber lining
Be very careful when removing the baffle plates from the stove.
Lift up the lower baffle plate, remove the pins and take out the baffle plate.
Lift the upper baffle plate to the back of the combustion chamber.
Remove pins. Pull the plate free from the baffle plate holder and remove it.
Lift the combustion chamber lining’s sides, remove them from the rear cover and take them out.
Note that the combustion chamber lining’s sides support the rear cover so this could fall when the sides are removed.
Remove the rear cover
Page 26
25
26
TROUBLESHOOTING
Warranty
All wood-fired Scan products are made of high-quality materials and subject to strict quality controls before leaving the factory. We give a warranty of 5 years on manufacturing errors or defects.
You must quote your stove‘s product registration number when you contact us or your authorized Scan dealer with a warranty claim.
The warranty covers all parts which in the opinion of Scan A/S require repair or replacement due to manufacturing or construction error
The warranty applies to the original purchaser of the product only, and is not transferable (except on prior sale).
The warranty covers only damage caused by manufacturing or con­struction errors.
The following parts are not covered by the warranty
Wear and tear parts, such as the combustion chamber liners, baffle plates, riddling grate, glass, and seals (except for defects which were present on delivery).
Defects caused by external chemical and physical influences during transportation, storage and assembly, or at a later time.
Soot build-up caused by poor chimney draught, damp wood, or improper use.
Costs of additional heating in connection with a repair.
Transport costs.
Costs for setting up, removing the wood stove.
This warranty is void
In case of incorrect installation (the installer is responsible for observing and complying with legal requirements and local bylaws, along with this Instructions manual for the wood­ burning stove and accessories).
In case of improper use, and/or use of prohibited fuels, non-original spares (see this instructions manual).
If the product registration number of the stove has been removed or damaged.
In case of repairs that do not comply with our instructions or instructions by an authorized Scan dealer.
In case of any manipulation of the original state of this Scan product or its accessories.
This warranty is only valid in the country to which this Scan product was originally supplied.
Always use original replacement parts, or parts recommended by the manufacturer.
Smoke escaping
• Damp wood
• Chimney not drawing properly
• Chimney is not properly dimensioned for the stove
• Check if the smoke gas pipe/chimney are blocked
• Is the chimney the right height for its surroundings?
• At rear outlet, check that the flue pipe does not obstruct the chimney draught
• Vacuum in room
• The door is opened before the embers have burned down sufficiently
Wood burning too quickly
• The air valves are set incorrectly
• The baffle plates is incorrectly mounted or missing
• Inferior firewood (waste wood, pallets etc.)
• Chimney too large
Soot build-up on glass
• Incorrect secondary airflow setting
• Excessive primary air
• Damp wood
• Wood pieces too large on lighting
• Inferior firewood (waste wood, pallets etc.)
• Chimney not drawing sufficiently
• Vacuum in room
Excessive soot build-up in chimney
• Poor burning (more air required)
• Damp wood
The surface of the stove is turning grey
• Overheating (see instructions for heating)
Poor heating performance of stove
• Damp wood
• Not enough wood
• Inferior wood quality with low fuel value
• Baffle plates are not fitted correctly
Odour coming from stove
• The lacquer on the stove hardens when you use the stove for the first time; this can cause an odour. Open a window or a door for ventilation, and make sure the stove is heated up sufficiently to avoid odours later.
• When heating up and cooling down, the stove may make some clicking noises. These are due to the huge temperature differences to which the material is exposed and do not indicate any product defects.
Page 27
26
27
Own comments
Page 28
28
01.01.2018
28
Version:
UK 90065500
Scan A/S-DK-5492 Vissenbjerg