SCAN 58 - series,58-9,58-10,58-7,58-8,58-1,58-4,58-3,58-6,58-2,58-5 Assembly And Instruction Manual

SCAN A/S - DK-5492 VISSENBJERG
Scan 58 - series
ASSEMBLY- AND INSTRUCTIONS MANUAL
Congratulations on your new Scan wood-burning stove
You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of plea-
sure with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Please read this Assembly- and instructions manual before you start to assemble your stove.
2
CONTENTS
Table of contents
Technical data .............................................................................................. 3
Installation Safety Technical data and dimensions Dimension sketch for Scan 58 - series Type plate
Assembly ...................................................................................................... 10
Transport brackets Service box Additional accessories
Positioning your wood-burning stove Positioning near to non-flammable materials Distance to furniture Diatance to fl ammable walls Product registration number Adjusting screws Load bearing foundation Floor plate Existing chimney and pre-fabricated element chimney Connection between stove and steel chimney Requirements for chimney Connection with 90° elbow pipe Fitting the stove onto the plinth Fresh air intake Closed combustion system Connecting piece top outlet Preparing the stove for rear outlet Wall-hung model Fitting the Scan 58 wall-hung model Scan 58-9 and Scan 58-10 Scan 58-9 and Scan 58-10 with high top
Accessories .................................................................................................. 20
Mounting of high top for Scan 58-7 and Scan 58-8
Wall mounting kit for Scan 58 with high top Heat accumulating stones for high top
Fitting the soapstone top Fitting a storage door
Instruction for use ................................................................................... 26
CB technique Primary air Secondary air Baffl e plates Ash drawer Handle for riddling grate
Instructions for heating ......................................................................... 27
Lighting Handling fuel
Maintenance .............................................................................................. 29
Troubleshooting ........................................................................................ 31
TECHNICAL DATA
3
Installation
The house owner is responsible for ensuring that all necessary natio­nal and local safety measures are observed during installation and fitting and also responsible for observing the fitting and operating instructions detailed in this manual.
When you install any kind of fireplace or stove, you must inform the local authorities. You are also responsible for calling in a chimney sweep to inspect and authorize the installation.
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Our Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
Safety
Any changes made to the product by the dealer, installer or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
Technical data and dimensions
Materials: steel plate, cast iron, galvanised sheet, skamol
Surface treatment: Senotherm
Max. wood length: 33 cm
Weight Scan 58: ca. 100 kg
Weight Scan 58-9 and Scan 58-10: ca. 160 kg
Weight Scan 58-7 and Scan 58-8 with high top: ca. 120 kg
Weight Scan 58-9 and Scan 58-10 with high top: ca. 200 kg
Weight heat-accumulating stones: ca. 86,5 kg
Connecting piece internal diameter: 135 mm
Connecting piece external diameter: 148 mm
Approval type: Intermittent fuelling
Test in compliance with EN 13240
Basic data for the Scan 58 - series
CO Emission at 13% O2: 0,11% 1338 mg/Nm
3
Dust @ 13% O2: 44 mg/Nm
3
Nox @ 13% O2: 119 mg/Nm3
Nominel output: 5,5 kW
Amount of smoke: 6 g/sek
Sub-pressure EN 13240: 12 Pa
Recommended sub-pressure in connecting piece: 18-20 Pa
Required combustion air supply: 16,5 Nm3/h
Fuel: Wood
Fuel consumption: 1,8 kg/h
Amount of fuel: 1,4 kg
Scan 58 excl. high top
Efficiency: 76%
Chimney temperature EN 13240: 271 °C
Temperature in connecting piece: 350 °C
Scan 58 incl. high top
Efficiency: 80%
Chimney temperature EN 13240: 228 °C
Temperature in connecting piece: 300 °C
Intermittent fuelling means normal use of a woodstove. In other words, you should let the fire die down until only the embers are left, before refuelling.
The Scan 58-series was build in compliance with the homologized product type specified in the Assembly- and Instructions Manual provided with the product.
The EC declaration of conformity is available from www.scan.dk
TECHNICAL DATA
1
1
3
8
1
7
5
9
9
8
*
175***
1
1
1
2
*
*
350500
108Ø
Dimension sketch Scan 58 with "see through" plinth
* Centre rear outlet
** Height to the beginning of the connecting piece at top outlet
*** Centre of fresh air in­ take bottom
**** Centre of fresh air intake rear
* Height to the begin­ ning of the connecting piece at top outlet
** Centre of fresh air in­ take bottom
*** Centre of fresh air in­ take rear
Dimension sketch Scan 58 with pedestal plinth
1
1
3
8
500
1
7
5
350
1
1
1
2
*
*
2
9
4
*
*
*
*
131***
160Ø
9
9
8
*
4
TECHNICAL DATA
5
500 350
403
7
6
4
6
2
4
*
5
7
2
*
7
3
6
*
*
6
8
4
*
*
4
3
0
*
*
*
*
2
2
8
184***
Dimension sketch Scan 58 Wall-hung model
* Centre rear outlet
** Height to the beginning of the flue pipe at top outlet
*** Centre of fresh air in­ take bottom
**** Minimum clearance above flammable mate rial
500 350
1
5
7
2
2
9
6
*
*
*
131***
114Ø
1
1
1
4
*
*
1
7
5
1
0
0
0
*
TECHNICAL DATA
6
500 350
1
1
4
0
1
1
1
4
*
*
2
9
6
*
*
*
*
1
0
0
0
*
1
7
5
114Ø
131***
Dimension sketch Scan 58-7 and Scan 58-8
* Centre rear outlet
** Height to the beginning of the connecting piece at top outlet
*** Centre of fresh air in­ take bottom
**** Centre of fresh air intake rear
* Height to the begin­ ning of the connecting piece at top outlet
** Centre of fresh air in­ take bottom
*** Centre of fresh air in­ take rear
Dimension sketch Scan 58-7 and Scan 58-8 with high top
TECHNICAL DATA
7
350
1
7
5
1
1
1
4
*
2
9
6
*
*
*
114Ø
131**
1
5
7
2
1
0
0
0
586
* Height to the begin­ ning of the connecting piece at top outlet
** Centre of fresh air in­ take bottom
*** Centre of fresh air in­ take rear
Dimension sketch Scan 58-9 and Scan 58-10 with high top
1
1
4
0
586 350
2
9
6
*
*
*
*
1
0
0
0
*
114Ø
131***
1
7
5
1
1
1
4
*
*
Dimension sketch Scan 58-9 and Scan 58-10
* Centre rear outlet
** Height to the beginning of the connecting piece at top outlet
*** Centre of fresh air in­ take bottom
**** Centre of fresh air intake rear
TECHNICAL DATA
8
Scan 58-3 & Scan 58-6 (with full lateral glass panes)
Scan 58-3 + Scan 58-
6
Freestanding room heater fired by solid fue
l
Standar
d:
Fuel type: Operation type: The appliance can be operated in a shared flue.
C
ountry
E
N 13240 EC no. 90
358602
Wood
Intermittent
EU
R
Norway
y
Classification
Intermittent
Klasse
2
C
ertificate/Standard
EN 13
240
SINTEF 110-029
8
Approved
by
pp y
RWE Power A
G
S
INTEF - NBL
Dust CO emission at 13% O2: 44 mg/Nm³ Flue gas temperature: 350°C Nominal heat output: 5,5
kW
Efficiency: 76%
Scan A/S DK 5492 Vissenbjerg
M
inimum distance to combustible materials
:
Sid
e: 600 mm - Back: 250 mm - Front: 1000 mm
C
O emission at 13% O2:
Follow assem
bly
- and instructions manua
l.
Use only recommended fuels
.
Montage- und Bedienungsanleitung beachten
.
Verwenden Sie nur empfohlene Brennstoffe
.
1000 05-2009
S
can
A/S DK
5492 Vissenbjer
g
0,11% 1338 mg/Nm
³
Schwei
z
Germany
y
LRV 1
1
BStV 1
VKF N 18900
F
SPS-Wa 1769-E
N
RWE Power A
G
RWE Power A
G
Type plates
All Scan wood-burning stoves are fitted with a type plate, that specifies the approval standards and the distance to flammable materials.
The type plate on the Scan 58-7, Scan 58-8, Scan 58-9 and Scan 58-10 is located in the magazine under the combustion chamber.
Scan 58-1 & Scan 58-4 (without lateral glass panes)
Scan 58-1 + Scan 58-4
Freestanding room heater fired by solid fuel
Standar
d:
Fuel type: Operation type
:
The appliance can be operated in a shared flue
.
Countr
y
E
N 13240 EC no. 90
358600
Woo
d
Intermitten
t
E
UR
Norway
y
Classificatio
n
Intermitten
t
Klasse 2
Certificate/Standar
d
EN
1324
0
SINTEF 110-02
98
App
roved
by
pp y
RWE Power A
G
S
INTEF - NBL
Dust CO emission at 13% O2: 44 mg/Nm
³
Flue gas temperature: 350°C Nominal heat output: 5,5
kW
Efficiency: 76%
Scan A/S DK 5492 Vissenbjerg
M
inimum distance to combustible materials
:
Sid
e: 350 mm - Back: 250 mm - Front: 1000 m
m
CO emission at 13% O2
:
Follow assem
bly
- and instructions manua
l.
Use only recommended fuels
.
Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 05-2009
S
can
A/S DK
5492 Vissenbjer
g
0
,11% 1338 mg/Nm³
Schwei
z
Germany
y
LRV 11
BStV 1
VKF N 18900
FSPS-Wa 1769-E
N
RWE Power A
G
RWE Power A
G
Scan 58-2 & Scan 58-5 (with half lateral glass panes)
Scan 58-2 + Scan 58-
5
Freestanding room heater fired by solid fuel
Standar
d:
Fuel type: Operation type
:
The appliance can be operated in a shared flue
.
Countr
y
E
N 13240 EC no. 90
358601
W
ood
Intermitten
t
E
UR
Norway
y
Classificatio
n
Intermitten
t
Klasse 2
Certificate/Standar
d
EN 1324
0
SINTEF 110-029
8
App
roved
by
pp y
RWE Power A
G
S
INTEF - NBL
Dust CO emission at 13% O2: 44 mg/Nm
³
Flue gas temperature: 350°C Nominal heat output: 5,5
kW
Efficiency: 76%
Scan A/S DK 5492 Vissenbjerg
M
inimum distance to com
bustible materials:
Sid
e: 600 mm - Back: 250 mm - Front: 1000 m
m
CO emission at 13% O2
:
Follow assem
bly
- and instructions manua
l.
Use only recommended fuels
.
Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 05-2009
S
can
A/S DK
5492 Vissenbjer
g
0
,11% 1338 mg/Nm³
Schwei
z
Germany
y
LRV 11
BStV 1
VKF N 18900
FSPS-Wa 1769-E
N
RWE Power A
G
RWE Power A
G
Scan 58-1 Wall & Scan 58-4 Wall (without lateral glass panes)
Scan 58-1 Wall + Scan 58-4 Wa
ll
Wall mounted room heater fired by solid fue
l
Standar
d:
Fuel type: Operation type: The appliance can be operated in a shared flue.
C
ountr
y
E
N 13240 EC no. 90
358611
Wood
Intermittent
E
UR
Norway
y
Classification
Intermittent
Klasse
2
C
ertificate/Standard
EN 13240
SINTEF 110-029
8
Approved
by
pp y
RWE Power A
G
S
INTEF - NBL
Dust CO emission at 13% O2: 44 mg/Nm³ Flue gas temperature: 350°C Nominal heat output: 5,5
kW
Efficiency: 76%
Scan A/S DK 5492 Vissenbjerg
M
inimum distance to com
bustible materials:
Sid
e: 350 mm - Front: 1000 m
m
C
O emission at 13% O2:
Follow assem
bly
- and instructions manua
l.
Use only recommended fuels
.
Montage- und Bedienungsanleitung beachten
.
Verwenden Sie nur empfohlene Brennstoffe
.
1000 05-2009
S
can
A/S DK
5492 Vissenbjer
g
0,11% 1338 mg/Nm
³
Schwei
z
Germany
y
LRV 1
1
BStV 1
VKF N 18900
F
SPS-Wa 1769-E
N
RWE Power A
G
RWE Power A
G
TECHNICAL DATA
9
Scan 58-2 Wall & Scan 58-5 Wall (with half lateral glass panes)
Scan 58-2 Wall + Scan 58-5 Wa
ll
Wall mounted room heater fired by solid fuel
Standar
d:
Fuel type
:
Operation type
:
The appliance can be operated in a shared flue
.
Countr
y
E
N 13240 EC no. 90
358612
Woo
d
Intermitten
t
E
UR
Norway
y
C
lassificatio
n
Intermitten
t
Klasse 2
C
ertificate/Standar
d
EN
1324
0
SINTEF 110-02
98
App
roved
by
pp y
RWE Power A
G
S
INTEF - NBL
Dust CO emission at 13% O2: 44 mg/Nm
³
Flue gas temperature: 350°
C
Nominal heat output: 5,5
kW
Efficiency: 76%
Scan A/S DK 5492 Vissenbjerg
M
inimum distance to combustible materials
:
Side:
600
mm - Front: 1
000 mm
C
O emission at 13% O2
:
Follow assem
bly
- and instructions manua
l.
Use only recommended fuels
.
Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 05-2009
S
can
A/S DK
5492 Vissenbjer
g
0,11% 1338 mg/Nm
³
Sch
wei
z
Germany
y
LRV 11
BStV 1
VKF N 18900
FSPS-Wa 1769-E
N
RWE Power A
G
RWE Power A
G
Scan 58-3 Wall & Scan 58-6 Wall (with full lateral glass panes)
Scan 58-3 Wall + Scan 58-6 Wa
ll
Wall mounted room heater fired by solid fuel
Standard:
Fuel type
:
Operation type
:
The appliance can be operated in a shared flue
.
Countr
y
E
N 13240 EC no. 90
358613
Woo
d
Intermitten
t
E
UR
Norway
y
C
lassificatio
n
Intermitten
t
Klasse 2
C
ertificate/Standar
d
EN 1324
0
SINTEF 110-029
8
App
roved
by
pp y
RWE Power A
G
S
INTEF - NBL
Dust CO emission at 13% O2: 44 mg/Nm
³
Flue gas temperature: 350°
C
Nominal heat output: 5,5
kW
Efficiency: 76%
Scan A/S DK 5492 Vissenbjerg
M
inimum distance to combustible materials
:
Side:
600
mm - Front: 1
000 mm
C
O emission at 13% O2
:
Follow assem
bly
- and instructions manua
l.
Use only recommended fuels
.
Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 10-2009
S
can
A/S DK
5492 Vissenbjer
g
0,11% 1338 mg/Nm
³
Sch
wei
z
Germany
y
LRV 11
BStV 1
VKF N 18900
FSPS-Wa 1769-E
N
RWE Power A
G
RWE Power A
G
Scan 58-7 & Scan 58-8
Scan 58-7 + Scan 58-8
Freestanding room heater fired by solid fue
l
Standar
d:
Fuel type: Operation type: The appliance can be operated in a shared flue.
C
ountr
y
E
N 13240 EC no. 9035860
9
Wood
Intermittent
EU
R
Norway
y
Classification
Intermittent
Klasse
2
C
ertificate/Standard
EN 13
240
SINTEF 110-02
98
Approved
by
pp y
RWE Power A
G
S
INTEF - NBL
Dust CO emission at 13% O2: 44 mg/Nm³ Flue gas temperature: 350°C Nominal heat output: 5,5
kW
Efficiency:76
%
Scan A/S DK 5492 Vissenbjerg
M
inimum distance to combustible materials
:
Sid
e: 350 mm - Back: 250 mm - Front: 1000 mm
C
O emission at 13% O2:
Follow assem
bly
- and instructions manua
l.
Use only recommended fuels
.
Montage- und Bedienungsanleitung beachten
.
Verwenden Sie nur empfohlene Brennstoffe
.
1000 05-2009
S
can
A/S DK
5492 Vissenbjer
g
0,11% 1338 mg/Nm
³
Schwei
z
Germany
y
LRV 1
1
BStV 1
VKF N 18900
FSPS-Wa 1769-E
N
RWE Power A
G
RWE Power A
G
Scan 58-7 & Scan 58-8 with high top
S
can 58-7 + Scan 58-8 with high to
p
Freestanding room heater fired by solid fue
l
Standard:
Fuel type
:
Operation type:
The appliance can be operated in a shared flue.
y
C
ountr
y
EN 13240 EC no. 90
358
619
Woo
d
Intermitten
t
E
UR
Norway
y
Austri
aClass
ificati
on
Intermitten
t
K
lasse 2
Certificate/Standar
d
EN
13240
SINTEF 110-0298
15
a B-VG
Approved
by
pp y
RWE Power A
G
S
INTEF - NB
L
RWE Power A
G
Dust at 13% O2: 44 mg/Nm
³
Flue gas temperature: 300
°C
Nominal heat output: 5,5
kW
Efficiency: 80%
Angaben für Österreic
h
W
ärmeleistungsbereich: 3,0 - 6,7 kW
Brennstoffwärmeleistung: 8,4 k
W
Zulässige Brennstoffe: Scheitholz Prüfbericht
:
FSPS-Wa 1769-A
Scan A/S DK 5492 Vissenbjerg
Minimum distance to com
bustible materials:
Side: 350 mm - Back: 250 mm - Front: 1000 m
m
C
O emission at 13% O2
:
Follow assembly- and instructions manua
l.
Use only recommended fuels. Montage- und Bedienungsanleitung beachten
.
V
erwenden Sie nur empfohlene Brennstoffe
.
1000 06-2010
Scan A/S DK
549
2 Vissenbjer
g
0
,11% 1338 mg/Nm
³
Schweiz
G
erman
y
y
LRV 11
BStV 1
VKF N 18900
FSPS-Wa 1769-E
N
RWE Power A
G
RWE Power A
G
ASSEMBLY
10
Additional accessories
Large shaped floor plate in glass or steel.
Small shaped floor plate in steel
Soap stone top for rear outlet
Soap stone top for top outlet
Soap stone top for stove with soap stone sides
Soap stone top with hole for stove with soap stone sides
Glass top plate for rear outlet
Glass top plate for top outlet
• Storage door
• High top (Scan 58-7 and Scan 58-8)
Wall mounting kit for Scan 58 with high top
Transport brackets
For Scan 58 with pedestal and see-through base / Scan 58 wall model, remove the transport brackets as shown below.
Service box
The service box contains the following:
Fitting for connecting piece
• Seal
• Safety fitting
Plastic plugs for transport safety hole at the bottom of the stove (not used for this Scan model)
• Various tools
• Glove
Fire starters for first lighting
Scan 58-9 & Scan 58-10
Scan 58-9 + Scan 58-1
0
Freestanding room heater fired by solid fue
l
Standar
d:
Fuel type
:
Operation type
:
The appliance can be operated in a shared flue.
y
C
ountr
y
E
N 13240 EC no. 90
358617
Wood
Intermitten
t
EUR
Norway
y
Class
ificati
on
Intermittent
K
lasse 2
C
ertificate/Standar
d
EN 13
240
SINTEF 110-029
8
Approved
by
pp y
RWE Power A
G
S
INTEF - NBL
Dust at 13% O2: 44 mg/Nm
³
Flue gas temperature: 350
°C
Nominal heat output: 5,5
kW
Efficiency: 76%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to com
bustible materials:
Side: 350 mm - Back: 250 mm - Front: 1000 m
m
CO emission at 13% O2
:
Follow assembly- and instructions manua
l.
Use only recommended fuels
.
Montage- und Bedienungsanleitung beachten.
V
erwenden Sie nur empfohlene Brennstoffe
.
1000 06-2010
Scan A/S DK
549
2 Vissenbjer
g
0,11% 1338 mg/Nm
³
Schweiz
G
erman
y
y
LRV 1
1
BStV 1
VKF N 18900
FSPS-Wa 1769-EN
RWE Power A
G
RWE Power A
G
Scan 58-9 & Scan 58-10 with high top
Scan 58-9 + Scan 58-10 with high to
p
Freestanding room heater fired by solid fue
l
Standard:
Fuel type
:
Operation type
:
The appliance can be operated in a shared flue.
y
C
ountr
y
E
N 13240 EC no. 90
358620
Wood
Intermitten
t
EUR
Norway
y
Austri
a
Class
ificati
on
Intermittent
K
lasse 2
C
ertificate/Standar
d
EN
13240
SINTEF 110-02
98
15 a B-V
G
Approved
by
pp y
RWE Power A
G
S
INTEF - NBL
RWE Power A
G
Dust at 13% O2: 44 mg/Nm³ Flue gas temperature: 300°C Nominal heat output: 5,5
kW
Efficiency: 80
%
Ang
aben für Österreic
h
Wärmeleistungsbereich: 3,0 - 6,7
kW
Brennstoffwärmeleistung: 8,4 k
W
Zulässige Brennstoffe: Scheithol
z
Prüfbericht:
F
SPS-Wa 1769-A
Scan A/S DK 5492 Vissenbjerg
Minimum distance to com
bustible materials:
Side: 350 mm - Back: 250 mm - Front: 1000 m
m
CO emission at 13% O2
:
Follow assem
bly
- and instructions manua
l.
Use only recommended fuels
.
Montage- und Bedienungsanleitung beachten.
V
erwenden Sie nur empfohlene Brennstoffe
.
1000 06-2010
Scan A/S DK
549
2 Vissenbjer
g
0,11% 1338 mg/Nm
³
Schweiz
G
erman
y
y
LRV 1
1
BStV 1
VKF N 18900
FSPS-Wa 1769-EN
RWE Power A
G
RWE Power A
G
ASSEMBLY
11
Distance to flammable walls
2
5
0
600
45° Corner installation
Parallel rear wall installation
Positioning your wood-burning stove
The wood-burning stove must be set up so that the stove itself, the flue pipe, and the chimney can all be cleaned.
Position near to non-flammable walls
When positioning near a non-flammable wall, we recommend you keep a minimum distance of 50 mm between the rear of the product and the wall for cleaning purposes.
Distance to furniture: 1000 mm
But please check to avoid furniture or other furnishings being dried out due to being too close to the stove.
2
5
0
600
2
5
0
350
Scan 58-3 & Scan 58-6 (with full lateral glass panes)
Parallel rear wall installation
Scan 58-2 & Scan 58-5 (with half lateral glass panes)
45° Corner installation
Scan 58-1 & Scan 58-4 (without lateral glass panes)
Scan 58-7, Scan 58-8, Scan 58-9, Scan 58-10 og Scan 58 with high top
Parallel rear wall installation
45° Corner installation
4
0
0
400
70
1
2
5
0
250
48
6
2
0
0
200
4
1
5
Loading...
+ 25 hidden pages