SCAN 56-1,56-2,56-3 User Manual

ASSEMBLY- AND INSTRUCTIONS MANUAL
Scan 56-1
Scan 56-2
Scan 56-3
Version:
GB 90056500-5
Congratulations on your new Scan wood-burning stove
You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of
pleasure with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Please read this Assembly- and instructions manual before you start to assemble your stove.
Make a note of your stove’s product registration number here so that you have it available if you need to contact us.
Test in compliance with
EN 13240
The EC declaration of conformity is available from www.scan.dk
Content
Installation ........................................................................................ 3
Installation Approval Technical data and dimensions
Dimension sketch ........................................................................... 4
Assembly ............................................................................................ 5
Service package Type plate Product registration number Accessories Positioning your wood-burning stove Position near to non-flammable walls Distance to flammable walls Distance to furniture Load bearing underlay Floor plate Adjusting screws
Rotating plinth
Connection between stove and steel chimney Requirements for chimney Connection with 90° elbow pipe Revolving plinth and 90° elbow pipe Flue collar top outlet Preparing the stove for a rear outlet Fresh air intake Closed combustion system
Chimney connection for the Scan 56 -2 .................................... 12
Solution with elbow pipe for brick chimneys
Top mounted steel chimney
Instruction for use ........................................................................ 14
CB Technology Primary air Secondary air Smoke deflector plates Ash pan Handle for riddling grate
Instructions for heating ............................................................... 15
Lighting Handling fuels
Maintenance .................................................................................... 17
Troubleshooting ............................................................................. 18
2 CONTENT
INSTALLATION
3
Installation
The house owner is responsible for ensuring that all necessary nati­onal and local safety measures are observed during installation and fitting and also responsible for observing the fitting and operating instructions detailed in this manual.
When you install any kind of fireplace or stove, you must inform the local authorities. You are also responsible for calling in a chimney sweep to inspect and authorize the installation.
To ensure best-possible functionality and safety for your installa­tion, we advise you to call a professional fitter. Our Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
Approval
If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chimney sweep for advice. These experts will also let you know if your flue needs renovating.
On connecting to a multiple element chimney: follow the vendor‘s instructions as applicable to the chimney type (e.g. Leca, Plewa, Ico­pal, Isokern, Zanda etc.)
No matter whether an authorised Scan dealer installs your stove, or you do the job yourself, remember that the chimney sweep has to approve the installation before you start to use it.
Technical data and dimensions
CO Emission at 13% O2: 0,07% 903 mg/Nm
3
Dust @ 13% O2: 38 mg/Nm
3
NOx @ 13% O2: 111 mg/Nm3
Efficiency: 73%
Rated heat load: 7 kW
Chimney temperature: 310 °C
Flue outlet flow: 8 g/sek
Recommended vacuum in flue collar: 20 Pa
Combustion air requirement: 24,9 Nm3/h
Recommended fuel: Wood
Fuel consumption: 2,4 Kg/h
Amount of fuel: 1,8 kg
Weight: Scan 56-1: 148 kg Scan 56-2: 149 kg Scan 56-3: 142 kg
Flue collar internal diameter: 135 mm
Flue collar external diameter: 148 mm
Approval type: Intermittent fuelling
Intermittent fuelling means normal use of a woodstove. In other words, you should let the fire die down until only the embers are left, before refuelling.
The Scan 56 was build in compliance with the homologized product type specified in the Assembly- and Instructions Manual provided with the product.
4
DIMENSION SKETCH
2
3
8
476
1
2
2
5
434
236
1
2
0
5
*
1
1
0
8
* Centre rear outlet ** Height to the beginning
of the flue pipe at top outlet
*** Centre fresh air intake
* Centre rear outlet ** Height to the beginning of
the flue pipe at top outlet
*** Centre fresh air intake
Dimension sketch for the Scan 56 range
1
2
2
5
1
2
0
5
*
*
1
5
0
*
*
*
80***
476
2
3
8
434
1
1
0
8
*
Scan 56-1 (fixed plinth) og Scan 56-2 (rotating plinth)
Scan 56-3 (profile plinth)
ASSEMBLY
5
Service package
The service package contains the following:
• Fitting for flue collar
• Seal
• Safety fitting
• Plastic plugs for transport safety hole at the bottom of the stove (not used for this Scan model)
• Various tools
• Glove
• Fire starters for first lighting
Product registration number
Open the wood-burning stove door; you can read and make a note of the product registration number (see front of these Assembly- and instructions for use).
Product registration number
Additional accessories
• Small shaped floor plate in glass (Scan 56-1 and Scan 56-3)
• Large shaped floor plate in glass (Scan 56-1 and Scan 56-3)
Type plate
All Scan wood-burning stoves are fitted with a type plate, that specifies the approval standards and the distance to flammable materials.
Scan
56
Freestanding room heater fired by solid fue
l
Standard:
Fuel type:
O
peration type
:
The appliance can be operated in a shared flue.
y
C
ountr
y
EN 13240 EC no. 90056600
Wood
Intermitten
t
E
UR
Norway
y
Classificatio
n
Intermitten
t
K
lasse
2
Certificate/Standar
d
EN 13
240
SINTEF 110-02
66
Approved
by
pp y
RWE Power A
G
S
INTEF - NB
L
Dust at 13% O2: 38 mg/Nm
³
Flue gas temperature: 310
°C
Nominal heat output: 7
kW
Efficiency: 73%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to com
bustible materials:
Scan 56-1 (fixed plinth) and Scan 56-3 (profile plinth): Side: 800 mm - Back: 150 mm - Front: 1000 mm
CO emission at 13% O2:
Scan 56-2 (revolving plinth):
Follow assembly- and instructions manual. Use only recommended fuels.
See assem
bly
- and instructions manua
l
Montage- und Bedienungsanleitung beachten
.
Verwenden Sie nur empfohlene Brennstoffe.
1000 04-2010
S
can
A/S DK 5492 Vi
ssenbjer
g
0,07% 903 mg/Nm
³
Schweiz
G
erman
y
y
LRV 1
1
BStV 1
VKF N 17929
F
SPS-Wa 1654-EN
R
WE Power A
G
R
WE Power A
G
6
ASSEMBLY
Distance to flammable walls
800
1
5
0
5
1
0
510
800
800
9
3
5
Positioning your wood-burning stove
The wood-burning stove must be set up so that the stove itself, the flue pipe, and the chimney can all be cleaned.
Position near to non-flammable walls
When positioning near a non-flammable wall, we recommend you keep a minimum distance of 50 mm between the rear of the product and the wall for cleaning purposes.
Distance to furniture: 1000 mm
But please check to avoid furniture or other furnishings being dried out due to being too close to the stove.
Loading...