INSTALLATION
3
Installation
The house owner is responsible for ensuring that all necessary national and local safety measures are observed during installation and
fitting and also responsible for observing the fitting and operating
instructions detailed in this manual.
When you install any kind of fireplace or stove, you must inform the
local authorities. You are also responsible for calling in a chimney
sweep to inspect and authorize the installation.
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Our Scan Dealer will
be able to recommend a qualified fitter in your area. For information
on Scan Dealers, please go to www.scan.dk.
Approval
If you intend to connect your stove to an existing chimney, it makes
sense to contact an authorised Scan dealer, or a local chimney sweep
for advice. These experts will also let you know if your flue needs
renovating.
On connecting to a multiple element chimney: follow the vendor‘s
instructions as applicable to the chimney type (e.g. Leca, Plewa, Icopal, Isokern, Zanda etc.)
No matter whether an authorised Scan dealer installs your stove, or
you do the job yourself, remember that the chimney sweep has to
approve the installation before you start to use it.
Technical data and dimensions
CO Emission at 13% O2: 0.09%
Støv @ 13% O2: 42 mg/Nm
3
Nox @ 13% O2: 114 mg/Nm
3
Efficiency: 79%
Rated heat load: 6 kW
Chimney temperature: 290°C
Flue outlet flow: 7.5 g/Sek
Recommended vacuum in flue collar: 16 Pa
Combustion air requirement: 21 Nm3/h
Recommended fuel: Wood
Fuel consumption: 2.25 kg/h
Amount of fuel: 1.7 kg
Min./max. heating performance (vendor specification): 4-8 kW
Weight: Scan 53: 160 kg Scan 53 wall-hung model: 147 kg
Flue collar internal diameter: 135 mm
Flue collar external diameter: 148 mm
Approval type: Intermittent fuelling
Intermittent fuelling means normal use of a woodstove. In other
words, you should let the fire die down until only the embers are
left, before refuelling.
Scan 53 and Scan 53 wall-hung model was build in compliance with
the homologized product type specified in the Assembly- and Instructions Manual provided with the product.