SCAN 40 Instructions For Installation And Use Manual

SCAN 40
INSTRUCTIONS FOR
INSTALLATION AND USE
This manual is accompanied by a pamphlet with General Instructions for Installation.
Edition 10.06 - GB
SCAN 3
BRU
GSAN
V
ISNI
NG
Ti
l
d
e
n
n
e
B
r
u
g
s
a
n
v
i
s
n
i
n
g
h
ø
r
e
r
o
g
s
å
e
n
g
e
n
e
r
e
l
M
o
n
t
e
r
i
n
g
s
v
e
j
l
e
d
n
i
n
g
.
U
d
g
a
v
e
0
3
.
0
3
-
D
K
M
O
N
T
E
R
I
NG
S
V
E
J
L
E
D
N
I
N
G
m
e
d
b
r
u
g
s
-
o
g
f
y
r
i
n
g
s
a
n
v
i
s
n
i
n
g
I
n
d
h
ol
d:
G
e
n
e
r
e
l
l
e
r
å
d
o
g
a
n
v
i
s
n
i
n
g
e
r
.
.
.
.
.
.
.
.
.
.
2
-
3
R
e
k
l
a
m
a
t
i
o
n
s
r
e
t
T
y
p
e
-
o
g
m
i
l
j
ø
g
o
d
k
e
n
d
e
l
s
e
U
d
p
a
k
n
i
n
g
T
i
l
b
e
h
ø
r
t
i
l
d
i
n
p
e
j
s
M
o
n
t
e
r
i
n
g
a
f
k
a
k
l
e
r
o
g
fe
d
t
s
t
e
n
K
v
a
l
i
t
e
t
s
k
o
n
t
r
o
l
A
n
m
e
l
d
e
l
s
e
s
p
l
i
g
t
S
k
o
r
s
t
e
n
s
t
j
e
k
S
k
o
rs
t
e
n
s
l
ø
s
n
i
n
g
e
r
B
æ
r
e
n
d
e
u
n
d
e
r
l
a
g
B
n
d
b
a
r
e
l
l
e
r
i
k
k
e
b
r
æ
n
d
b
a
r
v
æ
g
G
u
l
v
p
l
a
d
e
V
a
r
m
e
f
or
d
e
l
i
n
g
S
e
l
v
l
u
k
k
e
n
d
e
l
å
g
e
J
u
s
t
e
r
s
k
r
u
e
T
y
p
e
s
k
i
l
t
P
r
o
d
u
k
t
i
o
n
s
n
r.
S
e
r
v
i
c
e
p
a
k
k
e
M
o
n
t
e
r
i
n
g
s
v
e
j
l
e
d
n
i
n
g
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
-
7
T
i
l
s
l
u
t
n
i
n
g
t
i
l
e
k
s
i
s
t
e
r
e
n
d
e
/
m
u
r
e
t
s
k
o
r
s
t
e
n
T
i
l
s
l
u
t
n
i
n
g
t
o
p
a
f
g
a
n
g
t
i
l
s
t
å
l
s
k
o
r
s
t
e
n
F
o
r
b
n
d
i
n
g
s
l
u
f
t
u
d
e
f
r
a
B
r
u
g
s
-
o
g
f
y
r
i
n
g
s
a
n
v
is
n
i
n
g
.
.
.
.
.
.
.
.
.
.
.
8
-
10
V
e
d
l
i
g
e
h
o
l
d
e
l
s
e
a
f
p
e
j
s
e
o
v
n
e
n
H
å
n
d
t
e
r
i
n
g
a
f
b
r
æ
n
d
s
e
l
O
p
t
æ
n
d
i
n
g
o
g
f
y
ri
n
g
F
e
j
l
s
ø
g
n
i
n
g.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
1
T
i
l
d
e
n
n
e
m
o
nt
e
r
i
n
g
s
v
e
j
l
e
d
n
i
n
g
h
ø
r
e
r
o
g
s
å
e
n
s
e
p
a
r
a
t
b
r
u
g
s
an
v
i
s
n
i
n
g
f
o
r
d
e
n
e
n
k
e
l
t
epe
j
s
.
U
d
g
a
v
e
0
2
/
0
3-
D
K
Approved according to EN 13240 2003
Declaration of Conformity
Manufacturer:
Krog Iversen & Co. A/S
DK - 5492 Vissenbjerg
Product:
SCAN 40
Description of product:
Room heater for closed operation
This product complies with the requirements
of the directive
CPD 89/106/EEC
Applied to harmonized standard EN 13240
Signature: _____________________________ Managing director Henning Krog Iversen
Clean combustion
The SCAN 40 uses the "CB technique" (Clean­Burn) to ensure an optimally clean combustion. The extra combustion air is preheated and led into the combustion chamber close to the ceramic smoke deflector.
Ceramic smoke deflectors
Lift up the lower ceramic smoke deflector, pull out the pins in the lateral combustion chamber plates and remove the deflector. The upper deflector is removed in the same way.
You have chosen a product from one of Europe's leading manufacturers of wood-burning stoves. We are convinced that your stove will be to your full satisfaction and give you many hours of pleasure if you follow the advice and instructions of this manual.
Please read this manual as well as the General Instructions for Installation before beginning the installation.
Congratulations on your new SCAN stove!
3
5
4
1
2
1 Ashtray. When you open the door, you have access
to the ashtray, which is placed below the combu­stion chamber. Attention! Be careful when you empty
ashes from the stove. There may be embers left for up to 24 hours after the stove was last used.
2 Lid for ashtray. Under the ashtray you will find a lid
to put on top of the ashtray when you carry it out for emptying.
3 Handle for shaking grate. The stove is equipped
with a shaking grate. When you activate the grate handle, the ashes from the combustion chamber are emptied into the ashtray.
4 Regulation for primary air. Turn the air valve in
order to open. The primary air is used when lighting and refuelling the stove. It should always be closed during continuous firing.
5 Regulation for combustion air. Push the button
sideways. Left position is closed and right position is open. The air is used for combustion and regulates the output of the stove.
The ashtray, shaking grate, and primary air should always be closed during continuous firing.
SCAN 40
Wood / briquettes
Fuel kg/h (beechwood
max. 20% humidity)
SCAN 40
1,8 kg
Combustion air %
100
Primary air %
25
Adjustment of the air
Accessories
For this model you can have the following accessories:
Handle
The handle is elegantly integrated on the moulding below the door. Pull out the handle to open.
Adjustment screws
The stove has two adjustment screws on the bottom that can be used for levelling the stove.
Self-closing door (BA 1)
The door is prepared with a self-closing function at the factory. If you tighten the spring with the hexagon spanner, the door will close automatically when you let go of it.
• Lateral covering in soapstone
• Soapstone-top plate
• Soapstone for the bottom
• Door in front of the wood compart­ment
• Baking-compartment door
• Shaped floor plate (steel or glass)
• Glazed baking tile
• Connection piece for fresh-air intake
Adjustment of the handle
Adjust the handle to the moulding by means of the adjustment screw.
SCAN 40
Data for calculation of the chimney
Stove
model
SCAN
Connecting
adaptor
mm
1
Density of
flue gas
flow
g/s
2 Flue gas tempera-
ture
o
C
3
Minimum
draft
Pa
4
Density of
flue gas
flow
g/s
5
Flue gas
temperature
o
C
6
Minimum
draft
Pa
7
0,8
Minimum
draft
Pa
40
150 - - - 6 270 14 11
With closed doorsWith open doors
Column 2 and 5 show the flue gas temperature in the connecting adaptor Column 3 and 6 show the lowest/minimum draft in Pa by rated value Column 7 shows the lowest/minimum draft in Pa by 0.8 x rated value
The stove can be prepared for an external air supply where fresh air is let directly into the combustion chamber (can also be done subsequently by the authorized dealer).
Krog Iversen & Co. A/S - DK-5492 Vissenbjerg
1110
576
160
496
925
195
1033
Warranty conditions
All SCAN wood-burning stoves and inserts are made of first-class material and are subject to a strict quality control before they leave the factory. However, if an error should occur, we back all SCAN wood-burning stoves and inserts with an extensive, five-year limited warranty.
See also the General Instructions for Installation delivered with your stove for more details.
Technical info
Rated output: 6 kW Min./max.: 2 - 8 kW Weight: 130 - 240 kg Connection piece, diameter: ext. 148 mm / int. 135 mm
*
**
* To the middle of the rear outlet ** Height to the beginning of the flue pipe at top outlet *** Connection piece to fresh-air intake
Distances to flammable materials (mm)
Production number
Write the production number of your stove here so that you have it at hand in case you need to contact us.
You can choose between several floor plates in different shapes and dimensions for your stove. Furthermore, you can have a specially made, shaped floor plate for the SCAN 40, which is to be placed in front of the stove. Please contact your local authorities concerning the security distances needed.
SCAN 40
200
200
300
300
300
800
500
500
800
Radiation area
Base plate
200
You should read this manual as well as the General Instructions for Installation before beginning the installation.
***
Loading...