CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE
You have purchased a product by one of Europe’s leading manufacturers of wood-bur­ning stoves, and we are sure that you will have years of pleasure from your purchase.
To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.
SCAN 1005 BB SCAN 1005 WC SCAN 1005 BS
SCAN 1006 WC SCAN 1006 BSSCAN 1006 BB
2
Page 3
CONTENTS
¬¬
TECHNICAL DATA 4
Installation 4 Safety 4 Technical data and dimensions 5 Dimension sketch Scan 1005 6
¬¬
ASSEMBLY 10
Tools needed for mounting of the insert 10 Loose parts 10 Additional accessories 10 Disposal of packaging 10 Load-bearing foundation 10 Floor plate 11 Convection air 11 Existing chimney and pre-fabricated element chimney 11 Connection between built-in stove and steel chimney 11 Requirements for chimney 11 Internal installation in non-flammable material 11 Trims and doors 12 Gasket 12 Distance to furniture 12 Safety distance 12
Dimension sketch Scan 1006 7 Type plate 8 Product registrationumber 9
Building into flammable material with fire wall 13 Operating the door 16 Remove packaging 16 Fitting the flue connection piece 18 Fresh air intake 18 Closed combustion system 18 Mounting of external air supply 19 Fitting without the convection connection pieces 21 Fitting the convection connection pieces 21 Fitting the cassette 22 Mount the insert in the cassette 25 Mounting of the trim 26 Mounting of convection grate 27 Mounting of combustion chamber 28 Adjustment of the door 30
¬¬
INSTRUCTIONS FOR USE 31
CB-technology (Clean Burn) 31 Baffle plate 31
¬¬
INSTRUCTIONS FOR HEATING 32
Environmentally friendly operation 32 Lighting 32 Continuous operation 33 Warning about over-firing 33 Using the stove in various weather conditions 33
¬¬
HANDLING OF THE FUEL 35
Selecting wood/fuel 35 Preparation 35 Storing 35
¬¬
MAINTENANCE 36
Sweeping the chimney and cleaning the stove 36 Checking the stove 36 Servicing 36 Combustion chamber lining 36 Gaskets 36
Primary air 31 Secondary air 31
Firing in the spring or autumn 33 General notes 33 The function of the chimney 34 Chimney fire 34
Moisture 35 Use of the following as fuel is illegal 35 Calorific value of the wood 35
Painted surfaces 36 Cleaning the glass 37 Baffle plates and combustion chamber lining 37 Disposal of stove parts 37
¬¬
TROUBLESHOOTING 38
¬¬
WARRANTY 39
3
Page 4
TECHNICAL DATA
INSTALLATION
¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local
building regulations as well as the information provided in this Assembly and Instructions Manual.
¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition
you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning.
¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your Scan
dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
SAFETY
Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
PLEASE NOTE!
YOU GET THE BEST USE OF
THE STOVE BY USING
A TOP-DOWN
LIGHTING METHOD
SEE
"INSTRUCTIONS FOR HEATING"
4
Page 5
TECHNICAL DATA AND DIMENSIONS
Steel plate
Galvanised sheet
Materials
Ceramic stone/vermiculite
Chamotte
Robax glass
Surface treatment Senotherm
Max. wood length Scan 1005 50 cm
Max. wood length Scan 1006 65 cm
Weight Scan 1005 (Ceramic stone) ca. 113kg
Weight Scan 1005 (Vermiculite) ca. 99 kg
Weight Scan 1006 (Ceramic stone) ca. 132 kg
Weight Scan 1006 (Vermiculite) ca. 116 kg
Connecting piece internal diameter 144 mm
Connecting piece external diameter 148 mm
Approval type
Intermittent
fuelling*
Scan 1005 – Test in compliance with EN 13229
Combustion chamber
CO Emission at 13% O
CO Emission at 13% O
Dust @ 13% O
Nox @ 13% O
2
2
Ceramic stone
2
2
0,07 0,07 %
887 861 mg/Nm
19 25 mg/Nm
95 103 mg/Nm
Vermi­culite
Efficiency 82 84 %
Energy efficiency index 109,9 112,8
Energy efficiency class A+ A+
Nominel output 6 6 kW
Chimney temperature EN 13229
Temperature in flue conn. piece
227 202 °C
272 242 °C
Amount of smoke 5,6 5,3 g/sec
Sub-pressure EN 13229 12 12 Pa
Recommended sub-pressure in connecting piece
Required combustion air supply 18 15 m
18-20 18-20 Pa
3
/h
Fuel Wood Wood
Fuel consumption 1,9 1,8 kg/h
Amount of fuel required to light 1,5 1,5 kg
Amount of fuel, max. 2,5 2,5 kg
* Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refuelling.
Scan 1005-1006 is produced in accordance with type approv­al for the product, which also covers the product’s Assembly and Instruction Manual.
The Declaration of Performance (DoP) is available from www. scan.dk
Scan 1006 – Test in compliance with EN 13229
Combustion chamber
CO Emission at 13% O
3
CO Emission at 13% O
3
Dust @ 13% O
3
Nox @ 13% O
Ceramic stone
2
2
2
2
0,07 0,07 %
887 905 mg/Nm
19 18 mg/Nm
95 95 mg/Nm
Vermi­culite
Efficiency 82 82 %
Energy efficiency index 109,9 109,9
Energy efficiency class A+ A+
Nominel output 6 7 kW
Chimney temperature EN 13229
Temperature in flue conn. piece
227 224 °C
272 269 °C
Amount of smoke 5,6 6,6 g/sec
Sub-pressure EN 13229 12 12 Pa
Recommended sub-pressure in connecting piece
18-20 18-20 Pa
Required combustion air supply 18 18 m
Fuel Wood Wood
Fuel consumption 1,9 2,2 kg/h
Amount of fuel required to light 1,5 1,8 kg
Amount of fuel, max. 2,5 3 kg
3
3
3
3
/h
EN 13229 was carried out on the installation shown on page 13.
5
Page 6
5
2
3
688
325
1
0
5
4
6
6
106
438
650
4
7
0
3
8
9
4
7
0
4
6
3
9
2
125
1
3
0
333
M
i
n
4
9
0
Min
6
7
0
M
i
n
4
5
0
DIMENSION SKETCH SCAN 1005
Top outlet
A
Rear outlet
B
Centre external air supply, rear side
C
Centre of external air supply, bottom
D
All measures are in mm
D
C
A
6
B
Page 7
4
6
3
4
7
0
3
8
9
1
0
5
400
5
2
3
838
800
200
1
3
0
438
106
4
7
0
4
6
6
9
2
333
Min
8
2
0
M
i
n
4
9
0
M
i
n
4
5
0
DIMENSION SKETCH SCAN 1006
Top outlet
A
Rear outlet
B
Centre external air supply, rear side
C
Centre of external air supply, bottom
D
All measures are in mm
D
A
C
B
7
Page 8
Scan 1006 CS
Insert fired by solid fuel
Standard:
Fuel type: Operation type:
Reaction to fire: A1
Country
EN 13229 EC no. 91006601
Wood
Intermittent
EUR
Classification
Intermittent
Certificate/Standard
EN 13229
Approved by
DTI NB.no. 1235
Dust at 13% O2: 19 mg/Nm³ Flue gas temperature: 227°C Nominal heat output: 6 kW Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials: See assembly- and instructions manual
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
The appliance can be operated in a shared flue.
Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 18
0,07% 887 mg/Nm³
Germany Stufe 2 1. BlmSchV DTI NB.no. 1235
Scan 1006 VE
Insert fired by solid fuel
Standard:
Fuel type: Operation type:
Reaction to fire: A1
Country
EN 13229 EC no. 91006600
Wood
Intermittent
EUR
Norway
Classification
Intermittent
Klasse 2
Certificate/Standard
EN 13229
NS 3058
Approved by DTI NB.no. 1235 DTI NB.no. 1235
Dust at 13% O2: 18 mg/Nm³ Flue gas temperature: 224°C Nominal heat output: 7 kW Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials: See assembly- and instructions manual
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
The appliance can be operated in a shared flue.
Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 18
0,07% 905 mg/Nm³
Germany Stufe 2 1. BlmSchV DTI NB.no. 1235
TYPE PLATE
Scan 1005 CS
Insert fired by solid fuel
Standard:
Fuel type: Operation type:
Reaction to fire: A1
Country
EN 13229 EC no. 91005601
Wood
Intermittent
EUR
Classification
Intermittent
Certificate/Standard
EN 13229
Approved by DTI NB.no. 1235
Dust at 13% O2: 19 mg/Nm³ Flue gas temperature: 227°C Nominal heat output: 6 kW Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials: See assembly- and instructions manual
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
The appliance can be operated in a shared flue.
Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 18
0,07% 887 mg/Nm³
Germany Stufe 2 1. BlmSchV DTI NB.no. 1235
Scan 1005 VE
Insert fired by solid fuel
Standard:
Fuel type: Operation type:
Reaction to fire: A1
Country
EN 13229 EC no. 91005600
Wood
Intermittent
EUR
Norway
Classification
Intermittent
Klasse 2
Certificate/Standard
EN 13229
NS 3058
Approved by DTI NB.no. 1235 DTI NB.no. 1235
Dust at 13% O2: 25 mg/Nm³ Flue gas temperature: 202°C Nominal heat output: 6 kW Efficiency: 84%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials: See assembly- and instructions manual
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
The appliance can be operated in a shared flue.
Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 18
0,07% 861 mg/Nm³
Germany Stufe 2 1. BlmSchV DTI NB.no. 1235
All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials.
The type plate (Vermiculite) is located on top of the stove.
The type plate (Ceramic stone) is in the box with the ceramic stones and must be stuck on top of the existing type plate.
Type plate Scan 1005 (Ceramic stone) Type plate Scan 1005 (Vermiculite)
Type plate Scan 1006 (Ceramic stone) Type plate Scan 1006 (Vermiculite)
8
Page 9
B
B
PRODUCT REGISTRATIONUMBER
All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S.
Product registration number Scan 1005 Product registration number Scan 1006
100500000 100600000
Type plates
A
Product registration number
9
Page 10
ASSEMBLY
TOOLS NEEDED FOR MOUNTING OF THE INSERT
¬ Spirit level ¬ Cutting nippers
¬ Cross tip screwdriver ¬ Flat head screwdriver
¬ Ø10 wall drill ¬ Open-end spanner
LOOSE PARTS
The trim is delivered on the wood pallet together with the insert.
In the insert’s combustion chamber you will find the following loose parts
¬ Bricks for the bottom of the burn chamber ¬ Log guard
¬ Glove
¬ Bag containing loose parts:
4 x self-tapping screws 4.2 x 6.5 mm 8 x 3 mm black self-adhesive gasket (2 m) (for fastening the sleeve Ø100 mm) (Ø100 mm sleeve, connecting piece and cassette)
4 x rawlplugs10 x 50 mm (for fastening the cassette) 4 x torx screws M6 x 50 (for fastening the cassette)
4 x discs Ø6.5 / Ø16 x 1.1 (for fastening the cassette) Torx key T30
Ø100 mm sleeve with flange
Combustion chamber package contains:
¬ Baffle plates ¬ Burn chamber plates (side and rear)
¬ 3 pins Ø6 x 40 mm
ADDITIONAL ACCESSORIES
¬ Convection adaptors Ø149 mm (see page 21)
¬ Convection grates (See page 27)
DISPOSAL OF PACKAGING
Your Scan built-in stove may come supplied with the following packaging:
Wood packaging
Polystyrene top Send for recycling or waste disposal.
Foam Send for recycling or waste disposal.
Plastic bags Send for recycling or waste disposal.
Stretch/plastic film Send for recycling or waste disposal.
The wood packaging can be reused and after final use can be incinerated as a CO2 neutral product or sent for recycling.
LOAD-BEARING FOUNDATION
All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any reinforcement of the beam structure. They can be positioned on ordinary beams/floor.
You should of course make sure that the foundation on which the stove is positioned can indeed support the weight of the stove and, where applicable, a steel chimney, if you have opted for this solution. In case of doubt about the carrying capacity of the floor, please consult a building expert.
10
Page 11
FLOOR PLATE
If you are placing the stove on a flammable floor, you must comply with the national and local regulations on the size of any non-flammable subsurface required to cover the floor around the stove.
Your local Scan dealer can advise you on regulations concerning protection of flammable materials in the vicinity of your stove.
The floor plate’s function is to protect the floor and flammable material against any sparks that may occur.
CONVECTION AIR
The covering must contain holes for convection air. Convection means that there is an air circulation ensuring that the heat is equally distributed in the room. It is important that the demands concerning convection areas are observed.
¬ Min. area for ingoing convection air: 350 cm
If there is not enough convection air, the covering may be damaged. Do not obstruct the convection holes.
Convection air grids are available as an accessory.
(BY BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL)
2
¬ Min. area for outgoing convection air: 500 cm
2
EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY
If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim­ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
¬ When connecting a pre-fabricated element chimney, follow the manufacturer’s connection instructions for the
relevant chimney type.
CONNECTION BETWEEN BUILT-IN STOVE AND STEEL CHIMNEY
Your Scan dealer, or local chimney sweep, can advise you on choosing a make and type of steel chimney. This ensures that the chimney will match your wood-burning stove.
REQUIREMENTS FOR CHIMNEY
The chimney must have a diameter of min. 148 mm and be labelled T400 and G for soot testing. The length must be min. 4 me­tres.
If you opt to connect the bulit-in stove with an elbow pipe, you should use a curved elbow, as this gives a better draught.
If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the horizontal part can be cleaned through here.
The requirements to the chimney and the flue pipe in terms of safety distances must be met.
¬ Choosing the wrong length or diameter of chimney could impair functionality
¬ Always comply exactly with the instructions provided by the chimney supplier
INTERNAL INSTALLATION IN NON-FLAMMABLE MATERIAL
When building or fitting into structures that do not contain flammable materials, a minimum distance of 10 mm must be main­tained between the brickwork and the convection hood. This is to prevent cracks in the brickwork caused by the expansion of the metal while the stove is heating. This construction does not require convection grates except for the convection air produced by the convection box of the insert. However, please note that without convection grates, the effect of the insert will be lower.
/ EXISTING BRICKWORK
11
Page 12
TRIMS AND DOORS
Trims and doors are fitted when the surfaces of the surround have been treated.
GASKET
Gasket 0,75 m is mounted on the inside of the cassette as shown.
Gasket
DISTANCE TO FURNITURE
Distance to furniture from glass: 1500 mm.
You should however assess whether furniture or other items might become excessively dry due to being too close to the stove.
The stove is NOT to be built into flammable materials without the use of a fire wall!
SAFETY DISTANCE
European, national and local regulations concerning safety distances for wood-burning stoves and flue pipes must be complied with.
12
Page 13
1
7
5
1
0
0
75 15
450
200
1
5
0
0
8
0
0
450
BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL
Installation with an un-insulated elbow pipe
Flammable material
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities
Chimney
All distances are in mm.
All distances are minimum distances
* Applies for all installations
Floor plate
These cover plates must be removed when installing into flammable material protected by insulation
Flammable materials
(Ceramic stone)
(Vermiculite)
(Ceramic stone) (Vermiculite)
* *
*
*
Cavities are not to be
filled out with
insulation material!
0 0 5
Ceiling
0 0 3
Min. 500 cm
Upper
convection
opening
0 1 7
Min. 350 cm
Lower
convection
opening
2
2
Distance to furniture from glass
Floor
13
0 2 4
Page 14
2
5
m
m
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL
Installation with an insulated, vertical flue pipe
- structure/surround to ceiling
(Ceramic stone)
(Vermiculite)
5
0
7
4
Tighten the space, for example with a
glass-gasket
Cavities are not to be filled out with insulation material!
Ceiling
0 0 3
75 15
(Ceramic stone)
(Vermiculite)
75 15
Upper
2
2
0 2 4
Min. 500 cm
convection
opening
0 0 4
Min. 350 cm
Lower
convection
opening
Flammable material
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities
All distances are in mm
All distances are minimum distances
14
Floor
The distance to fire wall (brick) depends on the use of an insulated flue pipe all the way down to the insert
Page 15
2
5
m
m
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL
Installation with an insulated, vertical flue pipe
- open structure/surround
Ceiling
When building or fitting into a structure/sur­round that is open at the top, the convection holes can be omitted. However, you should note that no top plate must be placed on the structure
0 0 9
opening
Convection
Min. 350 cm
Lower
convection
opening
0 0 5
0 0 4
2
0 2 4
Flammable material
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities
All distances are in mm
All distances are minimum distances
75 15
(Ceramic stone)
(Vermiculite)
Floor
(Ceramic stone)
(Vermiculite)
5
0
7
4
75 15
15
Page 16
OPERATING THE DOOR
1
Push down the handle and the door will open
2
The door should be banged shut, as on a car. Grip the handle (hold in a horizontal position) and bang the door shut
REMOVE PACKAGING
Check that the built-in stove is not damaged before installing it.
Scan 1005/1006 is delivered secured to the pallet. It is recommended that you remove the door and take all loose parts out of the combustion chamber before unscrewing the stove from the pallet; this will facilitate the mounting of the insert.
Dismount the combustion air box. This box is only needed, if the insert is to be connected with external air supply, see page 19.
1
To remove the door:
Loosen the pointed screw, remove the screw and the spring and lift off the door
Combustion air box
Screw and spring
16
Pointed screw
Page 17
REMOVE PACKAGING
2
Dismount the connecting piece:
Remove the baffle plate from the stove before the connecting piece is removed. Loosen (not dismount) the flange nuts holding the connecting piece inside the stove. Push the connecting piece in the direction of the arrow and remove it
Baffle plate
3
Lift the insert free from the grip holes in the front and pull it out of the cassette
4
Remove the two screws securing the cassette to the pallet
17
Page 18
FITTING THE FLUE CONNECTION PIECE
The insert is prepared for a top flue outlet from the factory, but the connection piece can be turned around for a rear outlet.
Mount the connecting piece on the insert, after it has been placed in the cassette.
If the radiation plate was removed before the mounting, remember to put it back in place before putting the burn chamber back into the cassette.
Radiation plate
Mount the gasket 3 x 8 mm at the edge of the flange of the connecting piece. Fasten the connecting piece with the flanged nuts
Gasket
4 x flange nuts M6
FRESH AIR INTAKE
In a well-insulated house, the air used up by the burning process has to be replaced. This particularly applies to houses with mechanical ventilation. There are different ways of making sure that an air exchange takes place. The most important thing is to ensure that there is a supply of air to the room where the wood stove is located. The external wall vent must be located as close to the wood stove as possible, and you must be able to close it when you are not using the wood stove.
National and local building regulations must be followed with regard to the connection of fresh-air intake.
CLOSED COMBUSTION SYSTEM
You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home. External combustion air is connected through a ventilation pipe via the wall or floor.
We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, which can be closed when the oven is not in use. It can also be an advantage to insulate the ventilation pipe.
Minimum Ø 100 mm ventilation pipe, maximum length: 6 metres with a maximum of 3 bends. We recommend smooth steel pipes.
NOTE: If the stove has a fresh air connexion or closed combustion, the ventilation pipe must be open, when the stove is in use!
18
Page 19
MOUNTING OF EXTERNAL AIR SUPPLY
To dismount the cover plates for the Ø100 mm sleeve, use an ordinary screwdriver as shown below. Tilt the screwdriver and loosen the cover plates.
External air supply on the rear of the cassette
External combustion air on the bottom of the cassette
MOUNTING OF EXTERNAL AIR SUPPLY
ON THE REAR OF THE CASSETTE
4 x self-tapping screws 4.2 x 6.5 mm
1
Mount the Ø100 sleeve
2
Hitch the combustion air box on the rear plate of the cassette.
This box must always be mounted when connecting the insert with external air supply.
IMPORTANT: Only use for connection with external air supply!
Mount the insert in the cassette (see page 22)
19
Page 20
MOUNTING OF EXTERNAL AIR SUPPLY THROUGH THE BOTTOM OF THE CASSETTE
4 x self-tapping screws 4.2 x 6.5 mm
1
Mount the Ø100 sleeve
2
Hitch the combustion air box on the rear plate of the cassette.
This box must always be mounted when connecting the insert with external air supply.
IMPORTANT: Only use for connection with external air supply!
3
Mount 0.5 m gasket round the flange of the sleeve Ø 100 mm
4
Turn the insert over and remove the cover plate at the bottom.
Mount the insert in the cassette (see page 22)
20
Cover plate
Page 21
B
B
FITTING WITHOUT THE CONVECTION CONNECTION PIECES
The cover plates in the top plate can be removed in order to reduce the temperature on the wall above the insert. If the insert is built into an existing fireplace the cover plates are not to be removed.
To dismount the cover plates for the convection air, use a slotted screwdriver as illustrated below. Tilt the screwdriver down­wards and loosen the cover plate. Fit and tighten the cassette, see "Fitting the cassette".
Cassette without cover plates
in the top plate
FITTING THE CONVECTION CONNECTION PIECES
1
(ACCESSORY)
Convection connection pieces Ø149 mm
To dismount the cover plates for the convection adaptors, use an slotted screwdriver as shown below. Tilt the screwdriver and loosen the cover plates.
Fastening points Cassette without cover plates
2
Fit and tighten the cassette, see "Fitting the cassette".
When the cassette has been tightened, fit the convection connection pieces. Fit these and tighten them through the hole for the flue connection piece.
6 x Allen screws M4x10
6 x Flange nuts M4
21
Page 22
FITTING THE CASSETTE
1
Place the cassette in the hole/surround
The adjustment points in the four corners of the cassette must be flush with the front of the surround.
22
2
To ensure that the cassette is level, you can adjust the adjustment screws with an open-end spanner
Page 23
FITTING THE CASSETTE
33
To secure the cassette, pre-drill the 4 holes with a 10 mm drill bit
Mount the rawl plugs, screws and discs. Make sure that the cassette is level before fastening it.
In order to fasten the insert, you can use the delivered torx key that you will find in the bag in the combustion chamber
4 x Rawl plugs 10 x 50
4 x Torx screws 6 x 50
4 x Washers Ø6,5 / Ø16 x 1,1
23
Page 24
FITTING THE CASSETTE
5
Loosen the two screws in the cassette
6
Remove the top plate of the cassette
The top plate of the cassette can be dismounted, after the cassette has been fastened. This can help facilitating the mounting of the insert
Top plate of the cassette
24
Page 25
MOUNT THE INSERT IN THE CASSETTE
1
The stove’s pivot pins must fit snugly in the grip holes in the cassette so that the stove is secured tightly
Insert seen from the side
Pivot pins on the insert
Bottom of the cassette
Grip holes for pivot pins
25
Page 26
C
MOUNT THE INSERT IN THE CASSETTE
2
In order for the insert to be mounted correctly, it must ”fall down” into the grip holes of the cassette, so that the insert stands on the bottom of the cassette
The bottom of the cassette
supports the insert
3
Remount the top plate of the cassette and the door
MOUNTING OF THE TRIM
We recommend that you do not mount the trim, until the insert has been approved by the chimney sweep, as he may demand to see the type plate which is situated on the top plate of the cassette (to dismount the top plate, see page 24).
Mount the guide pins of the trim into the locking devices of the cassette.
26
Guide pins
Locking devices
Page 27
MOUNTING OF CONVECTION GRATE (ACCESSORY)
1
Cut a hole in the wall according to the indicated measures
2
Mount the metal frame
3
Scan 1005: 626 x 123 mm / Scan 1006: 776 x 94 mm
Place the four magnets on each side of the metal frame and then mount the convections grates on the magnets
27
Page 28
MOUNTING OF COMBUSTION CHAMBER
Place the upper baffle plate in the top of the stove. It is important that the plate is placed correctly
Upper baffle plate
Note that the baffle plates are made of porous, ceramic material, and can break.
Exercise care when working
When installing the bottom stones follow instructions 2 and 3 - otherwise proceed to instruction 4
1
Place the log guard against the front of the insert Place the bottom stones with the inclined edge turning
2 3
to the rear and downwards
Mount the left rear plate
4
Mount the left burn chamber plate
5
28
Page 29
MOUNTING OF COMBUSTION CHAMBER
Mount the right burn chamber plateMount the right rear plate. The rear burn chamber plates must be mounted so that the holes of the plates are placed precisely over the tertiary holes of the insert
Mount the lower baffle plate. The baffle plate must be supported by the rear plates. Mount the pins and put the plate in place
76
8
29
Page 30
ADJUSTMENT OF THE DOOR
The door may "hang" a little over time. This can be solved by adjusting the adjustment screw of the door upwards using an 8 mm open-end spanner. The adjustment screw is placed at the top of the hinge as shown below.
30
Page 31
B
INSTRUCTIONS FOR USE
CB-TECHNOLOGY (CLEAN BURN)
The stove is equipped with CB technology. In order to ensure optimal combustion of gases released during the combustion process, air passes through a specially developed system of channels. The heated air is conducted into the combustion chamber through the holes in the rear lining of the combustion chamber and at the baffle plates. This airflow is controlled by the rate of combustion and cannot therefore be regulated.
NOTE: The wood must never be placed higher than the tertiary holes at the rear of the burn chamber (This does not apply at a cold start).
BAFFLE PLATE
The baffle plate is located in the upper part of the combustion chamber. The plate holds back smoke, making sure it stays inside the combustion chamber for a longer time before escaping through the chimney. This reduces the flue gas temperature as the gases have more time to dissipate heat to the stove.
The baffle plate must be removed for sweeping; see “Maintenance”. Note that the baffle plate is made of porous, ceramic materi­al, and is liable to break easily. You should therefore handle it with care.
The baffle plate is subject to wear and tear and not covered by the warranty.
PRIMARY AIR
The primary air is used when lighting the stove and must be closed after 10-20 minutes, when the fire has caught well. The prima­ry air can be used continuously when using very hard wood.
Settings for normal load: 0 - 30%
SECONDARY AIR
Secondary air is pre-heated and fed indirectly to the fire. At the same time, the secondary airflow cleans the glass pane to avoid soot build-up. If you over-restrict the secondary airflow, soot can build up on the glass pane. The secondary airflow determines the heat output from your wood stove.
Settings for normal load: 50 - 90%
Adjustment of air supply,
primary and secondary damper
Primary airCB-technique
0%-100%0%-100%
Primary air Secondary air
31
Page 32
INSTRUCTIONS FOR HEATING
ENVIRONMENTALLY FRIENDLY OPERATION
Avoid turning down your wood-burning stove to the point where no flames are visible from the wood, as this leads to poor combustion and low efficiency. The gases released from the wood will not be burnt off due to the low temperature in the combustion chamber. Some of the gases will condense in the stove and flue system as soot, and this could lead to your chimney catching fire at a later point. The residual smoke which exits the chimney will pollute the surrounding area and cause an unpleasant smell.
No matter how good your chimney is,
it will not perform well, if you do
not use it correctly. Equally, a poor
chimney may well give you acceptable
results, if you use it correctly
LIGHTING
We recommend the use of fire lighters, or similar products, which are available from your Scan dealer. Using fire lighters helps light the wood more quickly and keeps the combustion process clean.
See our video about correct firing on www.scan.dk or scan the QR-code. Please note that this video is only intended as a guide. You should also follow the instructions in the specific manual for your stove model!
NOTE: Never use liquid lighting fuels!
”TOP DOWN” LIGHTING
NOTE!
Scan the QR-code
and see our video
about correct firing.
"Top down" lighting is a more environmentally friendly way of lighting the fire and helps to keep the glass area as clean as possible.
Do as follows for a correct ”top down” lighting:
¬ 4 pieces of wood approx. 25-40 cm long with a weight of approx. 0.6-0.8 kg per piece
¬ 15 thin pieces of firewood, with a total weight of approx. 0.8-1.0 kg
¬ 3-4 fire lighters
1
Place the pieces of wood, firewood and fire lighters in the combustion chamber as shown below
2
Set the primary and secondary air controls to maximum in the lighting phase. If the fire is too strong, you may throttle down
the primary air damper (at the left)
NOTE: The wood must never be placed higher than the tertiary holes at the rear of the burn chamber (This does not apply at a cold start).
Tertiary holes
32
Place the fire lighters
between the upper sticks
Page 33
CONTINUOUS OPERATION
It is important to obtain as high a temperature as possible in the combustion chamber. This results in best possible use of the stove and fuel, as well as achieving clean combustion. In this way you will avoid build-up of soot on the combustion chamber lining and glass pane. During operation, you should not see any smoke; just a movement in the air that indicates combustion is in progress.
¬ After completing the lighting phase, you should have a good layer of embers in the stove; you can then start operation of it
properly.
¬ Add two pieces of wood at a time: they should be about 1 kg in weight and about 25-40 cm long
NOTE: The wood must catch fire quickly. This is why we recommend setting the primary air flow fully open. Operating the stove at too low a temperature and with too little primary air can lead to gases igniting, which can damage the stove.
¬ When adding wood, always open the glass door carefully to prevent smoke escaping. Keep the door closed during the whole
combustion phase
¬ Never add wood, while the fire is burning nicely
At the EN 13229-test the stove was fired as shown on the picture:
With three pieces of birch each 210 mm – with a total weight of 1.45 kg.
Primary air damper 0% open – secondary air damper 90% open.
WARNING ABOUT OVER-FIRING
If the stove is continiously fired with larger amounts of wood than recommended and/or receives too much air, this can cause a heavy heat development liable to damage both stove and the surrounding walls. We therefore recommend that you always observe the max. recommended amount of fuel (See under ”Technical Data”).
USING THE STOVE IN VARIOUS WEATHER CONDITIONS
The way the wind affects the chimney can have a big impact on how your stove reacts under various wind loads; you may need to adjust the airflow to achieve good combustion. Fitting a damper in the flue pipe may also help, as it will allow you to regulate the draught under changing wind loads.
Fog and mist can also have a big impact on chimney draught; you may need to use other settings for the combustion air to achieve good combustion.
FIRING IN THE SPRING OR AUTUMN
In the spring/autumn transition period, where there is less need for heating, we recommend you light the stove “top down” once, perhaps adding just two pieces of wood to ensure that the combustion chamber lining burns clean again.
GENERAL NOTES
PLEASE NOTE! Parts of the wood-burning stove, especially the outer surfaces, become hot during use. Due care should be exercised.
¬ Never empty ashes into a flammable container. Ashes can contain glowing embers long after you finish operating the stove
¬ When the stove is not in use you can close the dampers to avoid a draught through the stove
¬ If the stove has not been used for some time, you should check the flue passageways for potential blockages before relighting
¬ We advise you strongly not to use the insert over night. The insert is not suited for this purpose
NOTE: Never place flammable material in the radiation zone of the stove!
33
Page 34
THE FUNCTION OF THE CHIMNEY
The chimney is the wood-burning stove’s motor; its performance determines how well your stove will work. The draught in the chimney creates negative pressure in the wood-burning stove. The negative pressure draws the smoke out of the stove and takes in air through the combustion air damper to fuel the combustion process. Combustion air is also used for the airwash system that keeps the glass clear of soot.
The draught in the chimney is created by the difference in temperature inside and outside the chimney. The higher the difference in temperature, the better the draught. This is why it is important that the chimney reaches operating temperature before you reduce the damper settings to restrict combustion in the stove (a brickwork chimney will take longer to reach operating temperature than a steel chimney). It is very important that the operating temperature is reached as quickly as possible on days when the draught in the chimney is poor due to unfavourable wind and weather conditions. You need to get a few flames going as quickly as possible. Chop the wood extra thin; use an extra fire lighter etc.
¬ After longer periods without use, you must check the chimney flue for blockages
¬ You can connect several units to the same chimney. You should however first check the relevant regulations in this respect
CHIMNEY FIRE
In the event of a chimney fire, keep the stove door, ash drawer, and all dampers on the stove closed. In an emergency, call the fire service.
¬ We recommend that you get a chimney sweep to check the chimney before using the stove again
34
Page 35
HANDLING OF THE FUEL
SELECTING WOOD/FUEL
You can use any type of wood as fuel. However harder woods, such as beech or ash, are generally better for heating, as they burn more evenly and create less ash. Other woods, such as maple, birch and spruce, are excellent alternatives.
PREPARATION
The best fuel is obtained where the tree has been felled and the wood sawn and split before May 1st. Remember to cut the wood to match the size of the combustion chamber. We recommend a diameter of 6-10 cm. The length should be about 6 cm shorter than that of the combustion chamber to leave enough space for air to circulate. If the diameter of the wood is greater than the above, it should be split down its length. Wood that has been split dries faster.
STORING
You need to store the sawn and split wood in a dry place for 1-2 years before it will be dry enough to burn. Wood dries faster if you stack it in an airy place. Before using it, it is a good idea to store the wood for a few days at room temperature. Remember that wood absorbs moisture from the air during autumn and winter.
MOISTURE
To avoid problematic impact on the environment and to ensure optimum operating economy, the wood should be perfectly dry before it can be used as fuel. If you use wood that is too damp, most of the heat it produces will be used up in evaporating the water. The stove will accordingly not increase in temperature, nor emit heat to the room as a result. This is obviously poor econ­omy, and it will cause soot build-up on the glass pane, in the stove and in the chimney. Operation using moist wood also pollutes the environment.
¬ Maximum wood moisture content should not exceed 20%. A moisture content of 15-18% will deliver best efficiency.
¬ An easy way of checking wood moisture content is to knock the ends of the two pieces of wood together. If the wood is moist,
the sound will be slightly muffled.
¬ It is a good idea to take the wood into the house a day before it is to be used.
USE OF THE FOLLOWING AS FUEL IS ILLEGAL
NOTE: It is absolutely prohibited to fire with painted, pressure impregnated or glued wood or sea driftwood. Nor should you ever burn chipboard, plastics, waste or treated paper. These contain substances that are hazardous to human health, to the environment, your stove, and your chimney. In short - make sure you only use proper wood.
CALORIFIC VALUE OF THE WOOD
The various woods have different calorific values. In other words, for certain species of wood, you will need to use a greater quantity to achieve the same heating performance. This Instuction Ma­nual assumes that you will be using beach, which has a very high calorific value and is also the easiest wood to get hold on. If you use oak or beech as fuel, you need to bear in mind that these wood types have a greater calorific value than for example birch. To avoid any risk of damage to the stove, you should therefore make sure to use less fuel in these cases.
Wood types kg Drywood/m3Compared to beech
Hornbeam 640 110% Beech/Oak 580 100% Ash 570 98% Maple 540 93% Birch 510 88% Pine 480 83% Fir 390 67% Poplar 380 65%
35
Page 36
MAINTENANCE
SWEEPING THE CHIMNEY AND CLEANING THE STOVE
Follow national and local regulations for sweeping the chimney. We recommend having the stove cleaned regularly by a chimney sweep.
Before cleaning the stove and sweeping the chimney, the baffle plate must be removed. (See section “Baffle plates and combustion lining")
NOTE: All service and reparation must be done, when the stove is cold.
CHECKING THE STOVE
Scan A/S recommends that you check your stove thoroughly after sweeping/cleaning. Check all visible surfaces for cracks. Check that all joints are tight and that the gaskets are correctly seated. Worn or deformed gaskets should be replaced.
SERVICING
We recommend that the stove is thoroughly serviced at least every two years by a qualified fitter. Remember only to use original spare parts.
The service should include the following:
¬ Lubricate hinges using copper grease
¬ Check the gaskets. Replace any that are broken or have turned hart
¬ Check the combustion chamber lining and the grate
¬ Check heat-insulating materials
¬ Check the locking device
COMBUSTION CHAMBER LINING
Slight cracks can appear in the combustion chamber lining due to moisture or sudden heating/cooling. These cracks have no influence on the output or lifetime of your stove. However, if the lining starts to crumble and fall out, you must replace it.
The combustion chamber lining is not covered by the warranty.
GASKETS
All wood-burning stoves have seals made of ceramic material fitted to the stove, the door and/or the glass. These seals are subject to wear and tear and must be replaced when necessary.
Gaskets are not covered by the warranty.
PAINTED SURFACES
Clean your wood-burning stove by wiping it down with a dry, lint-free cloth.
If the paint finish gets damaged, you can purchase repair paint in spray form from your Scan dealer. As slight differences in colour shade are possible, we recommend you spray a larger area to achieve a natural blend. For best results, apply repair spray when the stove is warm enough for you to just keep your hand on it, but no hotter.
NOTE: Make sure to air the room thoroughly after applying spray paint.
36
Page 37
CLEANING THE GLASS
Our wood-burning stoves are designed to prevent serious soot build-up on the glass. The best way to achieve this is to make sure you have a good supply of combustion air. It is also very important that the wood is dry and the chimney correctly dimensioned.
Even if you operate the stove in accordance with our instructions, a slight film of soot may still accumulate on the glass.
You can
easily remove this film by wiping the glass down with a dry cloth and then with a cloth dampened with glass cleaner.
¬ Please note that the glass cleaner is not to get into contact with the gaskets, as this can discolour the glass permanently.
¬ The glass cleaner must not come into contact with the painted surfaces, as these can be damaged.
BAFFLE PLATES AND COMBUSTION CHAMBER LINING
Be very careful when removing the baffle plate from the stove.
¬ Lift up the lower baffle plate, remove the pins and take out the baffle plate
¬ Lift the upper baffle plate to the back of the combustion chamber and remove it
¬ Lift the burn chamber side plates free from the bottom stones and take them out. Please note that the sides support the rear
plates and that these may fall over, when the sides are taken out.
¬ Take out the rear plates.
Upper baffle plate
3 pins for
lower baffle plate
Lower baffle plate
Baffle plate in steel
Baffle plate in ceramic stone/vermiculite
DISPOSAL OF STOVE PARTS
Steel/cast iron Send for recycling
Glass Dispose of as ceramic waste
Combustion chamber lining Vermiculite, ceramic stone and chamotte are not recyclable. Dispose of as waste
Baffle plate Vermiculite, ceramic stone and chamotte are not recyclable. Dispose of as waste
Gaskets Dispose of as waste
37
Page 38
TROUBLESHOOTING
SMOKE ESCAPING
¬ Damp wood ¬ Chimney not drawing properly
¬ Chimney is not properly dimensioned for the built-in stove ¬ Check if the smoke gas pipe/chimney are blocked
¬ Is the chimney the right height for its surroundings? ¬ Vacuum in the room
¬ At rear outlet, check that the flue pipe does not ¬ The door is opened before the embers have burned down
obstruct the chimney draught sufficiently
WOOD BURNING TOO QUICKLY
¬ The air valves are set incorrectly ¬ The baffle plate is incorrectly mounted or missing
¬ Inferior firewood (wast wood, pallets etc.) ¬ Too much chimney draught
SOOT BUILD-UP ON GLASS
¬ Incorrect secondary airflow setting ¬ Excessive primary air
¬ Damp wood ¬ Wood pieces too large for lighting
¬ Inferior firewood (waste wood, pallets etc.) ¬ Chimney not drawing sufficiently
WHITE SHADOW ON THE INSIDE OF THE GLASS
¬ Over-firing (See "Instructions for heating") ¬ Too much primary air
¬ Vacuum in the room
EXCESSIVE SOOT BUID-UP IN CHIMNEY
¬ Poor burning (more air is required) ¬ Damp wood
THE SURFACE OF THE BUILT-IN STOVE IS TURNING GREY
¬ Over-firing (See "Instructions for heating")
POOR HEATING PERFORMANCE OF BUILT-IN STOVE
¬ Damp wood ¬ Not enough wood
¬ Inferior wood quality with low calorific value ¬ The baffle plates are not fitted correctly
SMELL AND SOUND OF THE BUILT-IN STOVE
¬ The lacquer on the built-in stove hardens, when you use the built-in stove for the first time; this can cause an odour. Open a
window or a door for ventilation and make sure that the built-in stove is heated up sufficiently to avoid odours later.
¬ When heating up and cooling down, the built-in stove may make some clicking noises. These are due to the huge temperature
differences to which the material is exposed and do not indicate any product defects.
38
Page 39
WARRANTY
All wood-fired Scan products are made of high-quality materials and subject to strict quality controls before leaving the factory. We give a warranty of 5 years on manufacturing errors or defects.
You must quote your stove‘s product registration number when you contact us or your authorised Scan dealer with a warranty claim.
The warranty covers all parts which in the opinion of Scan A/S require repair or replacement due to manufacturing or construc­tion error
The warranty applies to the original purchaser of the product only, and is not transferable (except on prior sale).
The warranty covers only damage caused by manufacturing or construction errors.
THE FOLLOWING PARTS ARE NOT COVERED BY THE WARRANTY
¬ Wear and tear parts, such as the combustion chamber liners, baffle plates, riddling grate, glass, and seals (except for defects
which were present on delivery).
¬ Defects caused by external chemical and physical influences during transportation, storage and assembly, or at a later time.
¬ Soot build-up caused by poor chimney draught, damp wood, or improper use.
¬ Costs of additional heating in connection with a repair.
¬ Transport costs.
¬ Costs for setting up or removing the wood stove.
THIS WARRANTY IS VOID
¬ In case of incorrect installation (the installer is responsible for observing and complying with legal requirements and local
bylaws, along with this Assembly- and Instructionsmanual for the wood-burning stove and accessories).
¬ In case of improper use, and/or use of prohibited fuels, non-original spares (see this Assembly- and instructions manual).
¬ If the product registration number of the stove has been removed or damaged.
¬ In case of repairs that do not comply with our instructions or instructions by an authorised Scan dealer.
¬ In case of any manipulation of the original state of this Scan product or its accessories.
¬ This warranty is only valid in the country to which this Scan product was originally supplied.
39
Page 40
NOTES
40
Page 41
414243
Page 42
Page 43
Page 44
Product registration number
Quote this number at all enquiries
SCAN A/S | Glasvænget 3-9 | DK-5492 Vissenbjerg | www.scan.dk
Edition: UK 91005500
29.08.2019
Loading...