SCAN 1001,1002 Assembly And Instruction Manual

Scan 1001
ASSEMBLY- AND INSTRUCTIONS MANUAL
SCAN A/S - DK-5492 VISSENBJERG
Congratulations on your new Scan built-in stove
You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of plea-
sure with your purchase.
To make the best possible use of your built- in stove, it is important that you follow our advice and instructions.
CONTENTS
2
Table of contents
Technical data ............................................................................................................. 3
Scan 1001 versions Installation Safety Technical data and dimensions Dimension sketch1 Product registration number Type plate
Assembly ...................................................................................................................... 6
Operating the door Loose parts Service box Additional accessories Remove packaging Load bearing foundation Floor plate
Installation in flammable material protected by insulation Internal installation in non-flammable material
Distance to furniture Trim and door Gasket Existing chimney and pre-fabricated element chimney Connection between stove and steel chimney Requirements for chimney Installation in flammable material protected by insulation
Defra’s air supply requirements
Connecting piece Fitting the cassette Mount the insert in the cassette Combustion chamber Indicator for control of air supply Mounting of the trim Fresh air intake Closed combustion system
Accessories ................................................................................................................. 22
Fitting the convection adaptors
Instruction for use .................................................................................................. 23
CB technique Baffle plates Primary air Secondary air
Instructions for heating ........................................................................................ 24
Lighting Handling fuel
Maintenance ............................................................................................................ 26
Troubleshooting ...................................................................................................... 28
Installation
The house owner is responsible for ensuring that all necessary natio­nal and local safety measures are observed during installation and fitting and also responsible for observing the fitting and operating instructions detailed in this manual.
When you install any kind of fireplace or stove, you must inform the local authorities. You are also responsible for calling in a chimney sweep to inspect and authorize the installation.
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Our Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk..
Technical data and dimensions
Materials: ................................. Steel plate, galvanised sheet, Vermicolite,
Chamotte, Robax glass
Surface treatment: ........................................................................... Senotherm
Max. wood length: ..................................................................................... 50 cm
Weight Scan 1001: ................................................................................ ca. 107 kg
Connecting piece internal diameter: ............................................... 144 mm
Connecting piece external diameter: .............................................. 148 mm
Approval type: ................................................................ Intermittent fuelling
Intermittent fuelling means normal use of a woodstove. In other words, you should let the fire die down until only the embers are left, before refuelling.
The Scan 1001 was build in compliance with the homologized product type specified in the Assembly- and Instructions Manual provided with the product.
The EC declaration of conformity is available from www.scan.dk
Test in compliance with EN 13229
Scan 1001 is available in the following versions:
Scan 1001 BB
(black glass decor, black trim, and black glass handle)
Scan 1001 WB
(white glass decor, black trim, and black glass handle)
Scan 1001 BC
(black glass decor, matt chrome trim, and clear glass handle)
Scan 1001 WC
(white glass decor, matt chrome trim, and clear glass handle)
TECHNICAL DATA
3
Safety
Any changes made to the product by the dealer, installer or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
Scan 1001 Technical data Unit
CO Emission at 13% O
2
0,07 %
CO Emission at 13% O
2
879 mg/Nm
3
Dust @ 13% O
2
12 mg/Nm
3
Nox @ 13% O
2
42 mg/Nm
3
Efficiency 82 %
Nominel output 7 kW
Chimney temperature EN 13229 220 °C
Amount of smoke 7,4 g/sek
Sub-pressure EN 13229 12 Pa
Recommended sub-pressure in connecting piece 16 - 18 Pa
Required combustion air supply 19,8 Nm3/h
Fuel Wood
Fuel consumption 2,2 kg/h
Amount of fuel 1,7 kg
688
623
105**
325
566
438
107
489
563
92*
570
650
125
130
Dimension sketch
Connecting piece - top outlet
Connecting piece - rear outlet
* Centre external air supply, rear side
** Centre of external air supply, bottom
TECHNICAL DATA
4
product registration number
A
Type plates
All Scan wood-burning stoves are fitted with a type plate, that speci­fies the approval standards and the distance to flammable materials.
Scan 1001
Insert fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13229 EC no. 91001600
Wood
Intermittent
EUR
Norway
Classification
Intermittent
Klasse 2
Certificate/Standard
EN 13229
300-ELAB-1588-NS
Approved by Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³ Flue gas temperature: 220°C Nominal heat output: 7 kW Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to heat insulation: Side: 25 mm - Back: 100 mm - Top: 800 mm - Bottom: 400 mm
Minimum insulation:
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 11-2012
0,07% 879 mg/Nm³
Schweiz
Germany
LRV 11
BStV 1
VKF
300-ELAB-1588-EN
Teknologisk Institut Teknologisk Institut
Enter the product registration number for the built-in stove here:
A
1001XXXXX
Type plates
Product registration number
All wood-burning stoves are provided with a product registration number.
Please make a note of this number below as you will always have to state it if you contact your dealer or Scan A/S.
TEKNISKE DATA
5
Additional accessories
Convection adaptors Ø149 mm (accessory), see page 21
Service box
The service box contains the following:
Fitting for connecting piece (not used for this Scan model)
• Seal
Safety fitting (not used for this Scan model)
Plastic plugs for transport safety hole at the bottom of the stove (not used for this Scan model)
• Various tools
• Glove
Fire starters for first lighting
Loose parts
The trim is delivered on the wood pallet together with the insert.
In the insert’s combustion chamber you will find the following loose parts:
Baffle plates
Burn chamber plates (side and rear)
Bricks for the bottom of the burn chamber
• Log guard
Service box
Bag containing loose parts:
4 x self-tapping screws 4.2 x 6.5 mm
(for fastening the sleeve Ø100 mm)
8 x 3 mm black self-adhesive gasket (2 m)
(Ø100 mm sleeve, connecting piece and cassette)
4 x rawlplugs10 x 50 mm (for fastening the cassette)
4 x torx screws M6 x 50 (for fastening the cassette)
4 x discs Ø6.5 / Ø16 x 1.1 (for fastening the cassette)
2 pins for the lower smoke deflector plate
Indicator for the regulation of the air supply
Ø100 mm sleeve with flange
Torx key 5 mm
Screw M5x6 (United Kingdom)
ASSEMBLY
6
Operating the door
Push down the handle and the door will open.
The door should be banged shut, as on a car. Grip the handle (hold in a horizontal position) and bang the door shut.
Dismount the connecting piece.
Loosen (not dismount) the flange nuts holding the connecting piece inside the stove. Push the connecting piece in the direction of the arrow and remove it.
Remove the two screws securing the cassette to the pallet.
Screws to be removed
C
Pull the insert out of the cassette.
ASSEMBLY
7
C
Remove packaging
Check that the stove is not damaged before installing it.
Scan 1001 is delivered secured to the pallet. It is recommended that you remove the door and take all loose parts out of the combustion chamber before unscrewing the stove from the pallet; this will facili­tate the mounting of the insert.
Dismount the combustion air box. This box is only needed, if the insert is to be connected with external air supply, see page 18.
B
To remove the door:
Loosen the pointed screw, remove the screw and the spring and lift off the door
Combustion air box
B
Pointed screw
Screw and spring
ASSEMBLY8
Before installing the stove
Load bearing underlay
You must ensure that the underlay on which the stove is to be instal­led is a supporting underlay that is strong enough to support the weight of the stove and, if necessary, the chimney and a surround. If you are unsure about the strength of the base, contact a specialist before the installation.
Floor plate
If you are setting up the stove on a flammable floor, observe national and local regulations on the size of the non-flammable underlay that covers the floor around the stove. Your local Scan dealer can advise you on regulations concerning flam­mable materials in the vicinity of your stove.
The idea behind the floor plate is that it protects the floor and flam­mable material against sparks. The floor plate can be made of steel or glass, and the stove can be set up on brick, natural stone or similar materials.
Installation in flammable material protected by insulation
All installations where there is no existing fireplace opening must be ventilated.
Structure/surround to ceiling:
Holes must be made in the structure/surround for convection air. Convection means that air circulation occurs, so that the heat is distributed more evenly around the room.
You must ensure that the requirements for convection areas are met. Area for convection air in: 350 cm2 Area for convection air out: 500 cm2
If insufficient convection is created, the structure/surround may be damaged.
Open the cassette in the top plate (see page 11).
Place an air baffle made from non-flammable material (such as Jøtul Firewall) in direct connection with the upper convection opening. It is recommended that you tilt the plate at an angle of 20–30° (see page 10).
Open structure/surround:
When building or fitting into a structure/surround that is open at the top, the convection holes can be omitted. However, you should note that no top plate must be placed on the structure (see page 11).
Open the cassette in the top plate (see page 11).
Internal installation in non-flammable material
When building or fitting into structures that do not contain flam­mable materials, a minimum distance of 10 mm must be maintained between the brickwork and the convection hood. This is to prevent cracks in the brickwork caused by the expansion of the metal while the stove is heating.
Distance to furniture: 1300 mm
But please check to avoid furniture or other furnishings being dried out due to being too close to the stove.
Trims and doors
Trims and doors are fitted when the surfaces of the surround have been treated. Trim, see page 19.
Gasket
Gasket
Gasket 0,75 m is mounted on the inside of the cassette as shown.
Existing chimney and pre-fabricated element chimney
If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chimney sweep for advice. These experts will also let you know if your flue needs renovating.
When connecting a pre-fabricated element chimney, follow the manufacturer’s connection instructions for the relevant chimney type.
Connection between stove and steel chimney
Your Scan dealer, or local chimney sweep, can advise you on choosing a make and type of steel chimney. This ensures that the chimney will match your wood-burning stove. As a general rule, the length of the flue should not be less than 4,5 m measured from the top of the wood-burning stove.
Some weather or installation conditions might require another length.
Choosing the wrong length or diameter of steel chimney could impair functionality.
Always observe the chimney vendor‘s instructions precisely.
Requirements for chimney
The chimney must be labelled T400 and G for soot testing.
If the chimney is installed as an extension of the stove and has a length of at least 4.5 metres, a 6" chimney can be used.
If the insert is connected with an elbow pipe or other bends on the chimney, we recommend a 7” chimney.
If you connect the stove with an elbow pipe, you should use a curved elbow, as this gives a better draught.
If you are connecting your stove using a sharp elbow bend, the clea­nout door should be in the vertical section, such that the horizontal part can be cleaned through it.
National and local regulations for chimney ducts in flammable materials must be respected to.
ASSEMBLY 9
Flammable materials
If the floor contains flammable materials the height above the floor must be at least 400 mm.
A front plate of non­flammable material.
Scan 1001
Minimum
measurements
1A Building height over flammable floor 400 mm
1B Free height over horizontal flue pipe to insulation material 600 mm
1C Free height over insert to insulation material 800 mm
1D Distance to flammable side wall in front of insert 450 mm
1E Distance to non-flammable (side wall) in front of insert 250 mm
1F Distance to insulation material, side 25 mm
1G Distance to insulation material, rear 100 mm
Distance to furniture 1300 mm
Distance from convection opening above stove to insulation material
400 mm
Convection air *
1H Lower convection opening 350 cm
2
1I Upper convection opening 500 cm
2
Insulation material
Porous concrete 100 mm
Rockwool Brandbatts with smooth heat-resistant surface 50 mm
Jøtul Fire Wall JGFW-5 50 mm
Data to use when building in the insert, see fig. 1
Bræ
ndbart materiale
Bræ
ndbart
materiale
Brændbart materiale
Isolationsmateriale
Insulation material
Scan 1001
1F
1F
1G
Flammable mate-
rials
Flammable materials
Flammable materials
Loading...