Scala KP-6166 Instructions For Use Manual

Digital Wrist Blood
Pressure Monitor
KP-6166
- Instructions for use -
Introduction
thank you for deciding for the blood pressure monitor KP-6166 from SCALA. To be able to utilise all advantages of the blood pressure monitor to the fullest, you should carefully read these instructions before using the monitor. Keep the instruction leaflet in a safe place.
Safety instructions
The blood pressure monitor KP-6166 enables you to monitor your blood pressure regularly. However, you should never change the treatment which your doctor has prescribed
Self-measurement means monitoring, it does not imply diagnosis or treatment.
Discuss unusual values with your doctor.
Do not change the medication prescribed by your doctor.
The heart rate is not a useful indicator of the frequency of a cardiac pace maker. Patients with cardiac arrhythmia should use the blood pressure monitor only after consulting a doctor.
Features of the KP-6166
- The blood pressure monitor has fuzzy logic to identify the pumping pressure.
If the pumping pressure set in the factory is not sufficient, the device
identifies this and continues pumping.
- The device has 2 selectable memories
each with 50 memory locations.
- The date and time are displayed and
stored together with every blood pressure value.
- 2 -
- If the battery icon is displayed, the batteries are discharged and the device cannot be used until new batteries are inserted.
- The handcuff is suitable for wrists from 135 to 195mm circumference.
Preparing the monitor for measurement / changing batteries
Insert the two supplied batteries in the battery compartment at the side of the blood pressure monitor as shown. Use only alkali batteries (LR03). If the batteries are depleted, the battery
icon
is displayed in the lower part of the LC display. The battery needs urgent replacement because you cannot use the monitor with depleted batteries.
The LC display
Setting the clock
After you have inserted the two batteries, you should set the clock. It starts with year „1/ 1“ (for the 1st month / 1st day) and “12:00“ o’clock after every battery change.
- 3 -
To set the clock, hold the MEMORY button pressed for about 5 seconds. The year blinks in the top left corner of the display.
Set the year with the ON/OFF button.
When the correct year is set, press the MEMORY button again. Now the 1 blinks in the top left corner of the LCD. It stands for the month. Set the month with the ON/OFF button. Another press of the MEMORY button sets another 1 blinking. It stands for the first day in the month.
Set the day with the ON/OFF button.
Another press of the MEMORY button takes you to the clock setting – the hours blink. As earlier, set the clock with the ON/OFF button. Pressing the MEMORY button advances to the minutes setting. Set the minutes with the ON/OFF button. A final press of the MEMORY button completes the setting of the date and time.
How to obtain correct measuring results
To obtain correct readings, measure the blood pressure always under the same conditions, at rest, not under the effect of alcohol, not during meals, not after heavy physical or mental stress. If possible, sit down at a table for the measurement.
Please note: The blood pressure monitor must be at heart level during the measurement, otherwise wrong readings are obtained.
- 4 -
The measuring method
Put the cuff around your left wrist making sure that the device rests on the artery and the top edge of the device is about 1 cm away from the wrist joint.
The cuff should be applied with moderate tightness.
Now select “your” memory area with the select button, which you want to use and in which you want to store your blood pressure values by pressing the MEMORY button. (The BP monitor has 2 different memory areas each with 50 memory locations. The other memory area can be used by family members or other persons.) After you press the button for selecting the memory area, the word USER 1 is displayed. Another press of the select button displays the word USER . So select ”your” USER memory. Then wait for 5 seconds until the displays disappears.
- 5 -
The monitor has adopted your data and is now ready for taking measurements. Pressing the ON/OFF button starts the automatic measurement. The cuff inflates to approx. 190 mmHg pressure.
The automatic deflation starts the measurement. After about 3 seconds, a heart icon starts blinking in the LC display. If a Korotkoff’s sound is detected already at that time, it means a systolic pressure of more than 150 mmHg. Then the monitor re-inflates (to about 220 mmHg). At the end of the measurement, the result is displayed in the LCD and the cuff deflates.
Aborting a measurement
You can stop the measurement at any time by pressing the ON/OFF button. The BP monitor deflates the cuff instantly.
The memory function
The KP-6166 saves up to 50 measurements in every memory area. Together with each measurement (systolic, diastolic and heart rate), the date and time are also saved. The measurement with the longest residence time in the memory is assigned number
1. All other measurements increment by one until number 50. Then the memory is full. The next measurement occupies memory location 50. The measurement formerly at location 50 changes to
location 49 (etc., 48Æ47 .... 2Æ1). The
oldest measurement formerly at location 1 is lost.
You can delete the measurements in the memory by removing the batteries for at least 2 minutes from the BP monitor.
- 6 -
WHO-Interpretation of blood pressure readings
29.12.2007
Meaning Systolic /
mmHg
Diastolic /
mmHg optimal < 120 < 80 normal < 130 < 85 high-normal 130 - 139 85 - 89 mildy hypertonic
140 - 159 90 - 99
hypertonic, medium severity
160 - 179 100 - 109
severly hypertonic
> 180 > 110
The World Health Organization (WHO) recommends medical treatment, when the blood pressure value exceeds 140/90 mmHg. The doctor should also be consulted when the blood pressure is too low, i.e. when the systolic value drops below 105 mmHg and/or the diastolic value below 60 mmHg.
Cleaning and maintenance
Do not expose the BP monitor to extreme temperature, moisture, dust or direct sunlight. The cuff contains a sensitive airtight bulb. Treat it with care and avoid any stress by torsion or kinking. Clean the BP monitor with a soft, dry cloth. Do not use fuel, thinner or other solvent. Remove specks on the cuff carefully with a wet cloth and soap water.
Do not wash the cuff.
Do not drop the BP monitor or treat it with force. Do not try to open the BP monitor. This will make the factory calibration invalid.
- 7 -
Troubleshooting and remedies
If a fault is detected during a measurement, the BM monitor displays „Err“ and a symbol (code for service personnel). From many years of experience we know that most faults are the consequence of wrong use. The most frequent causes of faults are excessive movement during the measurement, wrong application of the cuff, use of wrong batteries or use of a rechargeable battery. Wait at least 5 minutes before repeating the measurement.
Message
Error description Correction
The pressure measured was lower than 20mmHg.
Please measure again.
The pressure measured was higher than 300mmHg.
Please measure again.
Pumping error.
Please check cuff and try again.
The pressure can not be measured due to signal noise.
Please measure again.
The pumping pressure is higher than 300mmHg.
Please measure again.
or no
display
Low batteries.
Please check and replace the batteries if necessary.
Referenced norms
For registration, a defined number of blood pressure monitors was subjected to stringent clinical testing. These monitors used the same program for blood pressure measurement as your monitor uses. Thus, this program is also regarded as clinically tested.
- 8 -
The manufacture of the blood pressure monitor complies with the European norms for blood pressure monitors: EN 60601-1, EN 1060-1 to EN 1060-3.
Electromagnetic compatibility: The blood pressure monitor complies with the requirements of European norm EN 60601-1-2. The requirements of EU directive 93/42/EEC concerning medical devices, class IIa are complied with.
Warranty
We grant a warranty of two years the for blood pressure monitor KP-6166. Within this period, defects of the BP monitor will be repaired free of charge. You can also have your BP monitor repaired by our customer service after the warranty period. We will provide you with a free cost estimate for the repair. The warranty does not cover damage due to improper handling, accident, natural wear and tear (cuff), non-compliance with the instructions for use or unauthorized modifications of the monitor. Excluded from the warranty are: the packaging, batteries and the instructions for use.
Periodic re-calibration
We recommend periodic checks of the pressure indication every 2 years.
Disposal note
The disposal of batteries is regulated. Spent batteries are collected at collection points provided by battery dealers and the communities.
- 9 -
Dispose of the blood pressure monitor as prescribed. i.e., at a collection point for electrical scrap.
Specifications
Measuring method: Oscillometric Measuring range: Pressure: 20 to 280 mmHg Heart rate: 40 to 195 / min Measuring accuracy: stat. pressure: +/- 3 mmHg Heart rate: +/- 5 % Measuring value memory: 2 memory areas, each with 50 locations for systolic / diastolic / heart rate, date and time Display: LC display Pressure pick-up: Semi-conductor pressure sensor Automatic switch-off: after approx. 3 minutes of inactivity Voltage supply: 2 x LR03 (alkali batteries), Working temperature range: +10°C - +40°C Storage temperature range:
- 10°C - +50°C Weight (without batteries): approx. 140 g Cuff length: for wrist circumference from 135 mm to 195 mm
Specifications may change as technical
improvements take place
Manufacturer:
K-Jump Health Co., Ltd No. 56 Wu Kung 5
th
Road Wu Ku Industrial Park Taipei, Taiwan, 248 Factory: Dong Guang, Guangdong
Importer and customer service:
SCALA Electronic GmbH Ruhlsdorfer Straße 95 D-14532 Stahnsdorf
Loading...