SBM B6 SX, B8 SX, B10 SX, B12 SX, B16 SX User Instructions

...
Page 1
Manufacturer : Agent :
SBM 3 cottages de la Norge 21490 CLENAY – France
1
GAS INFRARED HEATERS
N° 05000004/5
1. PRODUCT SPECIFICATION
2. SAFETY RECOMMENDATIONS
3. IGNITION
4. SHUT-OFF
5. MAINTENANCE
6. CHANGING THE GAS USED
Page 2
2
1. PRODUCT SPECIFICATION :
Refer to the heater rating plate on the gas supply cover panel (see example below).
MODEL
B6 SX
B8 SX
B10
SX
B12
SX
B16
SX
B20
SX
B20-2
SX
B24
SX
B24-2
SX
B32
SX
B32-2
SX
B48-2
SX
B64-2
SX
Weight (kg)
2.5 2.9 3.1 3.4 4.1 5.0 5.0 5.5 5.5 6.7 6.7 9.4 12.2
Net calorific value Qn (kW) Hi
2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
G20
consumption
(Natural gas)
(m3/h)
0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
G31
consumption
(Propane)
(kg/h)
0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Combustion air G20
2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
(m3/h)
G31
2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal rate (m3/h)
25 33 38 51 67.5 76 76 102 102 135 135 202.5 270
B16 SX
1400
6,75
3P
G31 37
Page 3
3
2. SAFETY RECOMMENDATIONS :
THESE HEATERS MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED INSTALLER
IN ACCORDANCE WITH THE CURRENTLY APPLICABLE SAFETY REGULATIONS AND
WITH THE SBM SX INSTALLER INSTRUCTIONS No. 05000048.
TO AVOID ABNORMAL MECHANICAL CONSTRAINTS ON THE RADIANT, IT IS
RECOMMENDED THAT IT BE CONNECTED TO THE GAS MAINS BY A FLEXIBLE TUBE.
TO BE INSTALLED IN WELL-VENTILATED PREMISES. NOT FOR DOMESTIC USE.
2.1 HEATER INCLINATION
2.2 MINIMUM SAFETY CLEARANCES (INFLAMMABLE MATERIALS:
max
=70°C)
(*) For minimum 20° inclination
GAS SUPPLY
10 to 35°
10 to 35°
WRONG INCLINATION
CORRECT INCLINATION
1m
min.
2m
min.
HEATED
AREA
HEATED
AREA
1m
min.
0.6m
min.(*)
Page 4
4
3. START-UP :
Manual operation
Open the main gas valve.
Switch the power on. Start the heater ignition cycle. If the flame is not lit after 45 seconds, start a second ignition cycle. If the flame is still not lit or goes out, close the main gas valve, switch the power off and call your SBM installer.
Automatic control
(VisioLon Ind-T control module)
Open the main gas valve. Switch the power on. Check the settings (temperature, time). Change module programming if necessary.
4. SHUT OFF :
Close the main gas valve. Switch the power off.
5. MAINTENANCE :
To be performed once a year by your SBM installer, according to the SBM SX INSTALLER INSTRUCTIONS No. 05000048.
6. CHANGING THE GAS USED :
For any change in the type of gas used, please contact your SBM installer.
Page 5
Page 6
TO BE DISPLAYED
NEXT TO THE CONTROL UNIT
Page 7
Manufacturer
SBM 3 cottages de la Norge 21490 CLENAY - FRANCE
Agent’s stamp :
Installer’s Stamp :
GAS INFRARED HEATERS
SX USER GUIDE
N° 05000004/5
(TO BE DISPLAYED NEXT TO THE CONTROL UNIT)
M A N U A L O P E R A T I O N
IGNITION :
Open the main gas valve.
Switch the power on.
Start the heater ignition cycle.
If the flame is not lit after 45 seconds, start a second ignition cycle.
If the flame is still not lit or goes out, close the main gas valve, switch the power off and call your SBM installer.
SHUT-OFF :
Close the main gas valve.
Switch the power off.
MAINTENANCE:
To be performed once a year by your SBM installer, according to the SBM SX INSTALLER INSTRUCTIONS No. 05000048.
.
Page 8
Manufacturer
SBM 3 cottages de la Norge 21490 CLENAY - FRANCE
Agent’s stamp :
Installer’s Stamp :
GAS INFRARED HEATERS
SX USER GUIDE
No. 05000004/5
(TO BE DISPLAYED NEXT TO THE CONTROL UNIT)
A U T O M A T I C C O N T R O L
VisioLon Ind-T module
IGNITION :
Open the main gas valve.
Switch the power on.
Check the settings (temperature, time).
Change module programming if necessary.
SHUT-OFF :
Close the main gas valve.
Switch the power off.
MAINTENANCE :
To be performed once a year by your SBM installer, according to the SBM SX INSTALLER INSTRUCTIONS No. 05000048.
Loading...