SBM 2 ZRFA, 6 ZRFA, 3 ZRFA, 8 ZRFA, 12 ZRFA Technical Instructions

...
Page 1
FA HEATERS
TECHNICAL INSTRUCTIONS
N° 05000077/6
GAS HEATING FOR POULTRY AND LIVESTOCK
1. TECHNICAL SPECIFICATIONS
2. SAFETY INSTRUCTIONS
3. IGNITING OF HEATERS
4. SHUTT-OFF OF HEATERS
5. MAINTENANCE
6. GAS CONVERSION
7. SPARE PARTS
Manufacturer : SBM 3 cottages de la Norge 21490 CLENAY - FRANCE
1
1312
Page 2
1. TECHNICAL SPECIFICATIONS :
Refer to the heater rating plate attached to the filter support
see example opposite :
MODEL
certificate number 1312 AR 1201
2
ZRFA
3
ZRFA
6
ZRFA
8
ZRFA
ZRFA
12
16
ZRFA
212
FA
216
FA
Weight (kg)
Nominal heat flow Qn (kW) Hi (148mbar)
Max. heat flow Qm (kW) Hi (180mbar)
G20 (NG 148mbar) Consumption (m3/h)
G20 (NG 180mbar) Consumption (m3/h)
Ø prim inject (1/100mm) Ø injector (1/100mm)
G31 (Propane 148mbar) Consumption (kg/h)
G31 (Propane 180mbar) Consumption (kg/h)
1.55 1.70 2.10 2.50 3.00 3.50 6.50 7.80
0.80 1.25 2.80 3.30 5.00 6.50 9.50 12.50
0.88 1.38 3.09 3.60 5.50 7.16 10.48 13.78
0.086 0.133 0.296 0.350 0.530 0.688 1.005 1.323
0.095 0.145 0.326 0.386 0.585 0.759 1.108 1.459
48 57
0.062 0.098 0.220 0.260 0.390 0.510 0.740 0.980
0.068 0.108 0.242 0.286 0.430 0.562 0.816 1.080
none
54
80 95
95
100
110 135
125 150
2x110 2x120
2x132 2x132
Ø injector (1/100mm) 35 40 58 65 78 95 2x76 2x90
The correct operation of the heaters requires the renewal of 1 m3/h new air per kW of heating installed. This air renewal is additional to that required by the animals.
2
Page 3
6/8 ZRFA
2/3 ZRFA
12/16 ZRFA
2. SAFETY INSTRUCTIONS :
THE HEATERS SHOULD BE INSTALLED AND MAINTAINED IN
SUFFICIENTLY VENTILATED PREMISES BY A QUALIFIED INSTALLER
ACCORDING TO CURRENT SAFETY REGULATIONS.
NOT AUTHORISED FOR USE IN DOMESTIC PREMISES.
TO BE INSTALLED IN COMPLIANCE WITH
CURRENT REGULATIONS
AND IN
SUFFICIENTLY VENTILATED PREMISES
2.1 HEATER INCLINATION
TAKE CARE TO MOUNT THE BRACKET CORRECTLY
2.2 INCLINATION OF HEATERS 212 FA AND 216 FA
212 FA 216 FA
0,37m 0,50m
30° 30°
3
Page 4
2.3 MINIMUM SAFETY DISTANCES (INFLAMMABLE MATERIAL)
1m
mini
0,6m mini
min. height
2.4 HEATER ATTACHMENT
Table of minimum safety heights with respect to the ground :
MODEL MINI. HEIGHT (m)
2 ZRFA 0,30 3 ZRFA 0,30 6 ZRFA 0,50 8 ZRFA 0,50 12 ZRFA 0,50 16 ZRFA 1,00
min. height
212 FA 1,00 216 FA 1,00
For pratical hanging heights, please contact your SBM representative.
4
Page 5
ZRFA
valve
230V AC
3.1 CONNECTING THE GAS HEATER
RP3 + 1 x 0.25A fuse
Valve B10F or valve NPT
Chain 2.5m
Clik CL10
or CLT
brooder
3.2 IGNITION OF HEATERS (Automatic regulation)
IMPORTANT: Preheat the building 24 hours before the animals arrive.
Sensor cable
Optional plugs (not supplied)
Sensor A1 (supplied with VisioLon)
3. IGNITING THE HEATERS :
RCD 16A - 30mA (Residual Current Device)
Ground terminal
VisioLon Elv-T
Enclosure
KIT MODULE ENCLOSURE 2 ZONES
G6A or G10A
Main gas
G31 (Propane) 1.5 bar G20 (Natural gas) 1.5 bar
Gas filter
Open the main valve. Set the G6A-G10A MAXI gas regulators to 10, MINI to :
-  for all types of heater except 216FA.
-  for 216FA.
Switch on the installation power supply. Adjust the VisioLon Elv-T set-point to the temperature required for the
animals. Ignition of the heaters is automatically controlled by the VisioLon Elv-T.
5
Page 6
4. SHUT-OFF OF HEATERS :
Close the main gas valve. Switch off the installation power supply.
5. MAINTENANCE :
ONCE A WEEK (or more frequently if the flame becomes blue):
- remove the filter box.
- remove the dust from the filter media.
6
Page 7
ENTRELESCERAMIQUE
S
CLEAN THE HEATER ONCE A YEAR (or more often if the flame becomes blue):
- remove the injector block.
- clear the injector using a soft wire.
- blow compressed air inside the burner body.
JOINTS
AIR COMPRIME
COMPRESSED AIR
3 à 5 bar MAXI
3 to 5 bar max.
NE PAS SOUFFLER LES JOINTS
DO NOT AIM AT THE JOINTS BETWEEN THE CERAMIC PLAQUES
- check the condition of the ceramic plaques (visual check).
- check the heater attachments.
- check the tightness of all accessories
6. GAS CONVERSION :
The heaters are designed to operate with the following gas :
CATEGORY : GAS : PRESSURE : I I
GB/IE/TR G31 (PROPANE) 148 mbar
3P
GB/IE/TR G20 (NATURAL GAS) 148 mbar
2H
The equipment is adjusted for the type of gas and the pressure as displayed on the rating plate. For any change of the gas used, please contact your SBM representative.
7
Page 8
7. SPARE PARTS :
FOR ANY SPARE PARTS ORDER, PLEASE SPECIFY :
- heater type and serial number.
- type of gas.
- operating pressure. This information is displayed on the rating plate, attached to the heater.
A
B C
D E F
G
H J
1
1
ent
Rep
A THERMOCOUPLE 9802001 1 B MAGNETIC HEAD 9803001 1
C 10 MEDIAS 115 (1/2/3/6/8 ZRFA) 3800000 10
C 10 MEDIAS 160 (12/16 ZRFA) 3800012 10
C 10 MEDIAS 300 (212/216 FA) 3800015 10
D INJ. BLOCK A (delivered without injector)
E ORIFICE
F IGNITER 9801002 1
PIECE Ref. SBM Cond
 
G BA BLOCK 9801004 1
H BA BRACKETS (2) 9801000 1
J BA NUT 9801001 1
8
Page 9
Page 10
TO BE DISPLAYED
NEXT TO THE CONTROL UNIT
Page 11
3 to 5 bar max
FA HEATER INSTRUCTIONS FOR USE
N° 05000077/6
(TO BE DISPLAYED NEXT TO THE CONTROL UNIT)
A U T O M A T I C R E G U L A T I O N
VisioLon Elv-T module and G6A or G10A gas regulation
IGNITION: Open the main valve. Set MAXI gas regulator to 10, MINI to:
- for all types of heater except 216FA.
- for 216FA. Switch on the power supply. Adjust the VisioLon Elv-T set-point to the temperature required for the animals. Ignition of the heaters is automatically controlled by the VisioLon Elv-T.
SHUTTING DOWN: Close the main valve. Switch off the power supply.
CURRENT FAILURE: CASE No.1: Heaters operating at MINI.: Adjust the operating pressure using the MINI gas regulator, to obtain
the temperature required for the animals.
CASE No.2: The heaters are off :
Set the MINI gas regulator to 10. Open the main valve.
Press the push-button while applying a flame to the surface of
the ceramic plaques. Continue to press the push-button for 30 seconds.
Regulate heater power by adjusting the MINI gas regulator. When switching on the power again, adjust the MINI gas
regulator to 1.
MAINTENANCE:
CLEAN THE FILTER ONCE A WEEK (or more frequently if the flame becomes blue)
- remove the filter box.
- remove the dust from the filter media.
CLEAN THE HEATER ONCE A YEAR
(or more frequently if the flame becomes blue)
- remove the injector block.
- clear the injector using soft copper wire.
- blow compressed air inside the burner body.
Manufacturer : SBM 3, Cottages de la Norge 21490 CLENAY - FRANCE
Installer's stamp :
do not aim at the joints between the ceramic plaques
- check condition of ceramic plaques (visual check).
- check the heater attachment.
- check accessory seals.
compressed air
1312
Loading...