Manufacturer :
SBM 3 cottages de la Norge21490 CLENAY - FRANCE
1
1312
Page 2
1. TECHNICAL SPECIFICATIONS :
Refer to the heater rating plate attached to the filter support
see example opposite :
MODEL
certificate number 1312 AR 1201
2
ZRFA
3
ZRFA
6
ZRFA
8
ZRFA
ZRFA
12
16
ZRFA
212
FA
216
FA
Weight (kg)
Nominal heat flow
Qn (kW) Hi (148mbar)
Max. heat flow Qm (kW) Hi (180mbar)
G20 (NG 148mbar)
Consumption (m3/h)
G20 (NG 180mbar)
Consumption (m3/h)
Ø prim inject (1/100mm)
Ø injector (1/100mm)
G31(Propane 148mbar)
Consumption (kg/h)
G31(Propane 180mbar)
Consumption (kg/h)
1.55 1.70 2.10 2.50 3.00 3.50 6.50 7.80
0.80 1.25 2.80 3.30 5.00 6.50 9.50 12.50
0.88 1.38 3.09 3.60 5.50 7.16 10.48 13.78
0.086 0.133 0.296 0.350 0.530 0.688 1.005 1.323
0.095 0.145 0.326 0.386 0.585 0.759 1.108 1.459
48
57
0.062 0.098 0.220 0.260 0.390 0.510 0.740 0.980
0.068 0.108 0.242 0.286 0.430 0.562 0.816 1.080
none
54
80
95
95
100
110
135
125
150
2x110
2x120
2x132
2x132
Ø injector (1/100mm) 35 40 58 65 78 95 2x76 2x90
The correct operation of the heaters requires the renewal of 1 m3/h new air per kW
of heating installed. This air renewal is additional to that required by the animals.
2
Page 3
6/8 ZRFA
2/3 ZRFA
12/16 ZRFA
2. SAFETY INSTRUCTIONS :
THE HEATERS SHOULD BE INSTALLED AND MAINTAINED IN
SUFFICIENTLY VENTILATED PREMISES BY A QUALIFIED INSTALLER
For pratical hanging heights, please contact your SBM representative.
4
Page 5
ZRFA
valve
230V AC
3.1 CONNECTING THE GAS HEATER
RP3 + 1 x 0.25A fuse
Valve B10F
or valve NPT
Chain 2.5m
Clik CL10
or CLT
brooder
3.2 IGNITION OF HEATERS (Automatic regulation)
IMPORTANT: Preheat the building 24 hours before the animals arrive.
Sensor cable
Optional plugs
(not supplied)
Sensor A1
(supplied with VisioLon)
3. IGNITING THE HEATERS :
RCD 16A - 30mA
(Residual Current Device)
Ground terminal
VisioLon Elv-T
Enclosure
KIT MODULE ENCLOSURE 2 ZONES
G6A or G10A
Main gas
G31 (Propane) 1.5 bar
G20 (Natural gas) 1.5 bar
Gas
filter
Open the main valve.
Set the G6A-G10A MAXI gas regulators to 10, MINI to :
- for all types of heater except 216FA.
- for 216FA.
Switch on the installation power supply.
Adjust the VisioLon Elv-T set-point to the temperature required for the
animals.
Ignition of the heaters is automatically controlled by the VisioLon Elv-T.
5
Page 6
4. SHUT-OFF OF HEATERS :
Close the main gas valve.
Switch off the installation power supply.
5. MAINTENANCE :
ONCE A WEEK (or more frequently if the flame becomes blue):
- remove the filter box.
- remove the dust from the filter media.
6
Page 7
ENTRELESCERAMIQUE
S
CLEAN THE HEATER ONCE A YEAR (or more often if the flame becomes blue):
- remove the injector block.
- clear the injector using a soft wire.
- blow compressed air inside the burner body.
JOINTS
AIRCOMPRIME
COMPRESSED AIR
3à5barMAXI
3 to 5 bar max.
NE PAS SOUFFLER LES JOINTS
DO NOT AIM AT THE JOINTS
BETWEEN THE CERAMIC PLAQUES
- check the condition of the ceramic plaques (visual check).
- check the heater attachments.
- check the tightness of all accessories
6. GAS CONVERSION :
The heaters are designed to operate with the following gas :
CATEGORY : GAS : PRESSURE : I
I
GB/IE/TR G31 (PROPANE) 148 mbar
3P
GB/IE/TR G20 (NATURAL GAS) 148 mbar
2H
The equipment is adjusted for the type of gas and the pressure as displayed on
the rating plate. For any change of the gas used, please contact your SBM
representative.
7
Page 8
7. SPARE PARTS :
FOR ANY SPARE PARTS ORDER, PLEASE SPECIFY :
- heater type and serial number.
- type of gas.
- operating pressure.
This information is displayed on the rating plate, attached to
the heater.
A
B
C
D
E
F
G
H
J
1
1
ent
Rep
A THERMOCOUPLE 9802001 1
B MAGNETIC HEAD 9803001 1
C 10 MEDIAS 115 (1/2/3/6/8 ZRFA) 3800000 10
C 10 MEDIAS 160 (12/16 ZRFA) 3800012 10
C 10 MEDIAS 300 (212/216 FA) 3800015 10
D INJ. BLOCK A (delivered without injector)
E ORIFICE
F IGNITER 9801002 1
PIECERef. SBMCond
G BA BLOCK 9801004 1
H BA BRACKETS (2) 9801000 1
J BA NUT 9801001 1
8
Page 9
Page 10
TO BE DISPLAYED
NEXT TO THE CONTROL UNIT
Page 11
GAS CERAMIC HEATING
3 to 5 bar max
FA HEATER INSTRUCTIONS FOR USE
N° 05000077/6
(TO BE DISPLAYED NEXT TO THE CONTROL UNIT)
A U T O M A T I C R E G U L A T I O N
VisioLon Elv-T module and G6A or G10A gas regulation
IGNITION: Open the main valve.
Set MAXI gas regulator to 10, MINI to:
- for all types of heater except 216FA.
- for 216FA.
Switch on the power supply.
Adjust the VisioLon Elv-T set-point to the temperature required for the animals.
Ignition of the heaters is automatically controlled by the VisioLon Elv-T.
SHUTTING DOWN:Close the main valve.
Switch off the power supply.
CURRENT FAILURE: CASE No.1: Heaters operating at MINI.:Adjust the operating pressure using the MINI gas regulator, to obtain
the temperature required for the animals.
CASE No.2: The heaters are off :
Set the MINI gas regulator to 10.
Open the main valve.
Press the push-button while applying a flame to the surface of
the ceramic plaques. Continue to press the push-button for 30
seconds.
Regulate heater power by adjusting the MINI gas regulator.
When switching on the power again, adjust the MINI gas
regulator to 1.
MAINTENANCE:
CLEAN THE FILTER ONCE A WEEK (or more frequently if the flame becomes blue)
- remove the filter box.
- remove the dust from the filter media.
CLEAN THE HEATER ONCE A YEAR
(or more frequently if the flame becomes blue)
- remove the injector block.
- clear the injector using soft copper wire.
- blow compressed air inside the burner body.
Manufacturer : SBM
3, Cottages de la Norge
21490 CLENAY - FRANCE
Installer's stamp :
do not aim at the joints between the ceramic plaques
- check condition of ceramic plaques (visual check).
- check the heater attachment.
- check accessory seals.
compressed air
1312
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.