This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with IEE Wiring regulations and current Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
When changing a bulb, always switch off at the mains and allow the old bulb to cool down before handling. Dispose of used bulbs carefully and responsibly. Do not exceed the wattage stated or use a different shape bulb from that indicated on the fitting.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.
This product is rated at IP44.
This product is not suitable for location in or near a marine or sea environment.
The shade must be replaced immediately should the shade become cracked or damaged. This tting must not be used without the shade in place.
Care Information
Allow 10 minutes to cool before replacing, adjusting or cleaning. Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product.
Assembly/ User Instructions
Before you start
Please read these instructions carefully before tting and retain for reference. Check the packaging and make sure that you have all the required parts. Follow each assembly step in order to prevent incorrect assembly. Ensure that the product is fully assembled as illustrated before use.
The Light pack contains:
Light tting. Terminal connection block(s). Fixing pack.
These assembly diagrams are intended as a guide – if in doubt consult a qualied electrician.
Layout
Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the
junction box and the light fitting.
This product is designed for domestic and light industrial use. It should not be used to support other
objects or used as a replacement for concrete or metal pillars.
Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated
junction boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
We recommend that you use H05RN-F specification cable (not supplied) which is an outdoor grade,
The following tools may be required:
Selection of cross and at head screwdrivers. Electric drill and assorted drill bits. Wire strippers. Electrical insulation tape.
Endon Lighting, LS9 0SE
25571-Louvre-Post 20151210
Assembly/ User Instructions Continued
rubber sheathed cable. The mains supply cable must have a minimum cross sectional area of 1.0mm²
Cables must be protected using suitable conduit or plastic trunking.
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.
Fitting
Supplied Fixings
Concrete Base
1. The product must be mounted onto a concrete base or paving slab. It should not be directly installed in
the soil.
2. Position the supplied right angle J bolts as shown in the diagram. Use the base of the unit for alignment.
3. Position the conduit or plastic trunking so that the cable comes up that the centre point of the bollard.
Ensure that the cables do not snag.
4. Double check that the fixings line up with the holes in the base of the fitting before concreting into position,
and allow to set.
Conduit
Wiring
Having correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the connection block inside the product in the following way:
5. Pull terminal block from inside of tube.
6. Unscrew the 4 screws which attach the black box to the
spacing strip. Open the black box and pull out the terminal block.
7. Connect Live input wire to brown wire on product (or terminal
on terminal block marked ‘L’).
8. Connect Neutral input wire to blue wire on product (or
terminal on terminal block marked ‘N’).
9. Connect Input Earth wire (Green/yellow) to Earth wire on
fitting,
10. Check that you have correctly identified the supply wires, the
connections are tight and that no loose strands have been
left out of the connection block.
11. Push terminal block back into the black box. Re-attach the
black box to the mounting bracket.
Check That...
You have correctly identified the wires. The connections are tight. No loose strands have been left out of the connection block.
Commissioning
12. Replace the plastic cover and stainless steel plate ensuring that the screws are securely tightened.
13. Replace fuse or circuit breaker and switch on. Your light is now ready for use.