Wiring
• Unclip the cover from the quick fit connection case. Having correctly identified the wiring from your existing light
fitting, pull the mains wire through the hole and connect to the connection block inside the quick fit connection
case in the following way. No tools are necessary.
PUSH DOWN
INSERT CABLE
LOOP
EARTH (GREEN/YELLOW) FOR TERMINATION
Check that...
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection block.
• The cover on the connection box has been replaced.
Instruction leaflet
Speculo fire rated recessed
downlight
79978, 79979, 79980
Fitting/Replacing the bulb: Max. 50W GU10
When changing a bulb, always switch off at the mains and allow the
bulb to cool before handling. Dispose of used bulbs carefully.
Use a soft cloth to handle bulbs, avoid directly touching the
bulbs as this will shorten their life. Do not exceed the
wattage stated or use a different shape bulb from that
indicated on the fitting.
Max. 50W GU10
Care and Safety
• We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could
damage the finish.
• For your safety, always switch off the supply before cleaning.
Iss .3 27/12/2018
WWW.saxbylighting.com Saxby lighting. BH23 3PE

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and
qualified electrician.
Install in accordance with IEE Wiring regulations
and current Building Regulations.
Check the pack and make sure you have all of the
parts listed.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting.
Ensure other persons cannot restore the electrical
supply without your knowledge.
This light fitting should be connected to a circuit
with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note
of the connections.
Cables must be protected using suitable conduit
or plastic trunking.
This product is suitable for indoor use only.
Do not attach to surfaces which are damp, freshly
painted or otherwise electrically conductive
(e.g. metallic surfaces).
This product meets the electrical installation
requirements for fire-rated ceiling lamps
(BS476 Part 21) and can withstand fire up to 30,
60 and 90 minutes. The fire protection is provided
by a glass lens. This has been tested and has
passed the relevant standards.
Technical data
Supply
Voltage:
Bulb Type:
240V~, 50 Hz
Max. 50W GU10
Layout
• Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances
each light fitting.
• Avoid locating any cables in positions that would
cause a hazard. Position cables and junction
boxes (not supplied) away from areas where
they may be at risk from being cut,
trapped or damaged.
If this unit is being fitted in a room containing
•
a bath or shower, a 30mA RCD must be
used - in accordance with IEE regulations.
This product is suitable for use in living areas,
•
Bathroom Zone 2 and outsides of zones.
Bathroom Zones Diagram
ZONE 1
ZONE 0
ZONE 2
60cm
radius
from tap
ZONE 2
60cm240cm
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the
existing fitting, carefully note the position of each set of wires.
Note that the switch is turned off before installation.
•
• The ceiling surface must be flat and smooth to ensure a good fit.
• Ensure free movement of air by removing void insulation from at least 100mm from around the hole.
Under no circumstances must these fittings be covered with insulating matting or similar material.
The unit must be located a minimum distance of 100mm from a joist.
•
• Cut the 67mm mounting hole in the ceiling taking care not to foul any pipes, mains cables or joists
beneath the surface. It is always recommended to cut the hole slightly smaller than the size
specified, and then file the hole until the recessed unit fits snugly.
• Fit the appropriate bulb into the lamp holder. NOTE: Never fit bulbs of a higher wattage than those
specified on the label (as these may cause overheating and damage the fitting).
• Push the spring clips upwards and fit the two longer arms into the ceiling hole.
• Push the unit up until firmly in position, ensuring that the cable is not trapped.
• Switch on. Your light is now ready for use.
225cm
0,5
IP65
Conformity with all relevant EC Directive requirements.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist.Check with your Local Authority or
local store for recycling advice.
This product is NOT suitable for direct mounting on normally flammable surfaces
(suitable only for mounting on non-combustible surfaces).
Minimum distance from lighted objects (0.5 metres)
The power supply is Double Insulated and does not require connection to an Earth circuit.
This product is suitable for dimming.
Jet-proof
See “Wiring”
2
diagram
3
1