Saxby Lighting 79197, 79198 Installation Instructions

Wiring
Having correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the connection block inside the product in the following way:
Check that...
Instruction leaflet
Carraway Wall
79197, 79198
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection block.
• When completed, ensure that there are no bare or loose strands of wire exposed, and cover all exposed areas of the connection block with 2 layers of insulation tape.
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could
damage the finish.
For your safety, always switch off the supply before cleaning.
WWW.saxbylighting.com Saxby lighting. BH23 3PE
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all of the parts listed.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the connections.
Cables must be protected using suitable conduit or plastic trunking.
Choose a suitable location for installing the product, away from trees, hot ventilator ducts, street lighting and traffic, which may interfere with its operation.
Take care not to drill into any pipes or mains cables beneath the surface during mounting holes preparation.
Never put anything on the product or hang anything on any part of this product
The product must be securely fixed to the mounting surface using the screws and wall plugs supplied. The screws and wall plugs supplied are suitable for “masonry” only. Other fixings not supplied and must be purchased.
Care must be taken when fitting or handling to prevent personal injury or damage to the product.
If mounting, note the position of the "This Way Up" label on the back of the product and ensure it is correctly oriented.
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.
Note that the power needs to be isolated/switched off at the fuse board.
We recommend connecting this PIR product to an external / wall switch in order to deactivate the motion detection function if necessary
Follow the diagram below to install the product.
This product is rated IP44 ((definition e.g. splash proof / rain proof etc). It is suitable for use outdoors but should not be immersed in water / sited in areas likely to be heavily splashed, either from above or below, or subjected to standing water.
At initial power-on activation, the lantern will switch on and may remain on for up to 2 minutes. Keep out of the way of the activation zone and once the light goes off make the setting adjustments.
See wiring diagram
PIR sensor (79198)
Adjustable up to 10 metres
Technical data
Supply
Voltage: 240V~, 50 Hz
Bulb Type:
IP44
LED (10.8W) SMD3528,4000K
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
Conformity with all relevant EC Directive requirements.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.Check with your Local Authority or local store for recycling advice.
Class I product, must be connected to earth.
This product is not suitable for dimming.
Splash-proof (This product is IP44 rated and is suitable for outdoor use)
1.8-2.5 m
4M 6M 10M8M
Detection range can be adjusted by turning ‘SENS’ screw
10m
90°
Take great care when adjusting the sensor screws not to overtighten as they can be easily broken.
The unit must be installed in a vertical position, and fitted 1.8m-2.5m above the ground.
The PIR sensor can be adjusted, allowing the detection distance to be altered to suit the location. The detection angle is set at 90 degrees. The duration that the lamp stays on can also be altered from (10±5) seconds - (4±1) minutes.
To Test the Lantern. Turn on the power. To test the PIR unit in daylight, turn both the timer dial (TIME)
and the Sensitivity dial (SENS) gently fully anti-clockwise with the blade of a small screw driver. Activate the PIR by covering the PIR lens with your hand. The unit will light and should stay on for approximately 5-15 seconds then go off. It will remain off until the light level drops.
To adjust Time On. By adjusting the TIME dial the unit will stay on (once activated) from 5 -15 seconds
(fully anti-clockwise) to 3 -5 minutes (Fully clockwise).
To adjust sensitivity – detection distance. By adjusting the SENS dial the detection distance can be changed
– minimum detection is fully anticlockwise - or maximum detection distance is dial turned fully clockwise.