Check that...
Commissioning
Fitting/replacing bulbs
Forca EM LED Bulkhead
77895
Recycling advice
Safety information
For your safety, always switch off the power supply before cleaning.
WWW.saxbylighting.com Saxby lighting. BH17 7BY
V2 14/02/2020

Installation
Warning
This product is Class 2 (Double insulated)
and must not be earthed.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge. If you are in any doubt,
please consult a qualified electrician.
Specification
Layout
This light fitting should be connected to a circuit with a
30mA RCD fitted.
If replacing an existing fitting, make a careful note of
the connections.
This product contains non-replaceable parts and
cannot be serviced. If damage occurs the part should
be scrapped.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This product is rated at IP65.
C
Battery warranty: 2 years
carefully note the position of each set of wires.
Wiring
PUSH DOWN
INSERT CABLE
Non-Maintained Wiring: The product is normally off and comes on during a power failure
PERMANENT
‘
Individual casings
Maintained (Unswitched) Wiring: The product is on permanently and comes on during a power failure
LINK CABLE
PERMANENT
Maintained (Switched) Wiring: The product is used as a normal light - switch on/off, light turns on/off.
Comes on during a power failure.
PERMANENT
SWITCHED LIVE
‘
‘
SWITCHED LIVE