Operation
• This unit works in maintained mode. The fitting can
be switched separately on or off. The unit will charge
automatically (LED is green). A single LED remains on
when the supply is interrupted.
• Locate the flying lead on the inver ter and plug into
the connector.
• Replace fuse or circuit breaker and switch on.
Ensure that the source is mains (240V ~ 50Hz).
• Verify that the Green LED is illuminated; this confirms
that the batteries are charging.
Battery Replacement
• If after routine operation check, the lamp does not
remain lit for the set period, a new battery may be
required.
• Switch off the electricity at the mains, allow batteries
to fully discharge then reconnect to supply and allow
to charge for 24 hours.
• Test again for two hours, if light does not remain lit
change the inverter / battery unit as follows:
• Charge the battery for at least 24 hours before first
use.
• If the LED is not illuminated then there may be no a.c.
supply, the battery has not been connected properly
or the internal circuit may have failed.
• The battery should be re-charged and checked every
three months.
• The battery should be discharged and the duration
of the lamp in emergency mode checked every six
months.
• Obtain a replacement battery / inverter unit. make a
note of the wiring, and remove from plate and refit the
new one.
• Perform full operation check and update test record.
• Refit the shade. Ensure that the seal is correctly
located.
• Restore power and allow to charge for 24 hours.
Instruction leaflet
Vigor EM LED Bulkhead
46429
Fitting/replacing bulbs
• This system contains non-replaceable parts and
cannot be serviced. If damage occurs the part should
We recommend cleaning with a soft dry cloth.
Do not use solvents or abrasive cleaners as these could
damage the finish.
be scrapped.
Recycling advice
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or retailer for recycling advice.
Safety information
For your safety, always switch off the supply before cleaning.
www.saxbylighting.com
Iss.1 11122012
Saxby Lighting Ltd. BH23 3PE

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge. If you are in any doubt,
please consult a qualified electrician.
This light fitting should be connected to a circuit with a
30mA RCD fitted.
If replacing an existing fitting, make a careful note of
the connections.
This system contains non-replaceable parts and
cannot be serviced. If damage occurs the part should
be scrapped.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This product is rated at IP44.
This product is not suitable for dimming.
These products should not be fitted to PIR circuits or
short duration timed switches.
Installation
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting, carefully note the position of each set
of wires.
• Unscrew the shade and set aside.
• Hold the product in place and mark the position of
the holes.
• Ensure the wall is capable of holding the weight
of the product, or if fitting to a ceiling, ensure
there is a joist at the point of fixing to support the
Wiring
Having correctly identified the wiring from your existing
light fitting, connect to the connection block inside the
SUPPLY
NEUTRAL
weight of the product. Take care to avoid damaging
any concealed wiring and pipes. The correct
fixings should be used for brick, cavity walls or
plasterboard.
• Pierce a hole in the grommet, and pull the cable
through.
• Fix into position.
• Wire as detailed below
product in the following way:
LIGHT FITTING
BLUE (N)
Specification
Voltage : 240V ~ 50Hz
Lamp : 16W SMD 5630 LED's
IP rating : 44
Lumens : 120lm in EM mode
Duration : 3 hours (180 minutes)
Operating Temperature : 10˚C to 50˚C
Layout
• Plan the desired layout of this fitting carefully,
ensuring the cables will reach the distance between
the junction box and the light fitting.
• Avoid locating any cables in positions that would
cause a hazard. Position cables and junction boxes
(not supplied) away from areas where they may be
at risk from being cut, trapped or damaged.
Maximum Operating Humidity : 90%
Change over Time : Approximately 1s
Battery Specification : 3.7V 1.3Ah Lithium
Battery Charge Time : 24 hours
• The mains supply cable must have a minimum cross
sectional area of 1.0mm².
• Cables must be protected using suitable conduit or
plastic trunking.
• The products can be wall or ceiling mounted. If wall
mounting ensure that the power supply is at the
bottom.
EARTH (GREEN/YELLOW)
SWITCHED LIVE
PERMANENT LIVE
Check that...
• You have correctly identified the wires
• The connections are tight
Commissioning
• Ensure that the screws and cable entry points are
sealed to maintain the IP rating of the product.
• Refit the shade, ensuring that the seals are correctly
GREEN/YELLOW
BROWN (L)
BROWN (L)
• No loose strands have been left out of the connection
block.
located.
• Replace fuse or circuit breaker and switch on. Your
light is now ready for use.