PIR Adjustment
To access the adjustment screws flip down the black cover over the PIR sensor. Take great care when adjusting the
sensor screws not to over tighten as they can be easily broken.
• The unit must be installed in a vertical position, and fitted 1.8-2.5m above the ground.
• The PIR sensor can be adjusted, allowing the detection
distance to be altered to suit the location. The detection
angle is set at 110º. The duration that lamp stays on can
also be altered from 5 seconds - 5 minutes. The LUX
rang is 10-2000 lux. Use a small screwdriver to adjust
the "TIME" and "SENS" screws. When adjusting the
sensitivity (detection distance) in daylight it will be
necessary to cover the sensor to simulate night time.
Adjustable up to 8 metres PIR Adjustment
appro. 110º
1.8- 2.5Metres
4M 6M
8M
The PIR sensor has a manual override function which can be operated by taking the following steps:
• When first switched on, the PIR sensor “warms up” for approx 1 minute and then goes into AUTO mode.
• In AUTO mode, switch the power OFF and ON twice within 3 seconds, the PIR sensor will switch to MANUAL mode.
In MANUAL mode, the light will remain ON permanently, without the PIR function.
• To return to AUTO mode, switch the power OFF and ON twice within
3 seconds.
• In either mode, if the power is switched OFF more than 6 seconds,
the PIR sensor will go through 'warm up' process again when you turn
it on next time.
POWER ON
MANUAL MODE
1
AUTO MODE
2
Care and Safety
For your safety, always switch off the power supply before changing lightbulbs, adjusting spotlight heads or cleaning.
Do not use solvents or abrasive cleaners as these could damage the finish.
In normal circumstances, stainless steel is very resistant to corrosion. It does however require maintenance to preserve the
high quality appearance. Wash the product with warm soapy water, removing all surface deposits. Rinse with clear water and
with a soft cloth, wipe dry.
In some cases, surface corrosion may arise after installation. This is normally caused by tiny iron particles left behind after
the brushing process when finishing.
Wash and dry as detailed above. Then with a soft cloth soaked with a protective oil, wipe all over. However if the
product is subject to extreme environmental conditions such as marine locations, industrial pollution and acid rain these
maintenance procedures should be carried out around four times a year. For severe corrosion, non-abrasive cream
cleaners or proprietary stainless steel cleaners should be used to remove the corrosion. Wash and dry as detailed above.
Then with a soft cloth soaked with a protective oil, wipe all over.
Do not clean the units with a pressure washer.
This LED's are protected by the glass shade. The shade part must be replaced immediately should it
Replace Cracked Shade
become cracked or damaged. This fitting must not be used without the glass shade in place.
Instruction manual
Palin PIR Wall
101351, 101352
3
101351 101352
V2 12/04/2023
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg
www.saxbylighting.com

Thank you for purchasing this light fitting. Please read the instruction carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instruction for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons
cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician.
This light should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
This product is suitable for location in or near a marine environment.
Always use the correct type and wattage bulb. Never exceed the wattage stated.
When changing a bulb, always switch off at the mains and allow the old bulb to cool down before handling.
Dispose of used bulbs carefully and responsibly.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between the junction box and the
each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated junction boxes
(not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
We recommend that you use H05RN-F specification cable (not supplied) which is an outdoor grade, rubber sheathed cable.
The mains supply cable must have a minimum cross section area of 1.0mm
2
.
Cables must be protected using suitable conduit or plastic trunking.
Technical data
Supply
Voltage:
220-240 V~, 50 Hz
Bulb
Type:
Conformity with all relevant UKCA Directive requirements.
101351---1 x Max. 7W LED GU10
101352---2 x Max. 7W LED GU10
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
•
Determine the position of your light fitting taking into account the entry position of the
cable and the ARROW indicating which WAY UP the base is to be fitted.
Make sure there is sufficient cable coming out of the wall to
connect to the terminal block. Ensure that the mounting
surface is solid, preferably a brick or block wall and
ensure that there are no other cables or pipes beneath
the surface.
•
Remove mounting box from the product by removing
dome nuts and washers. Pull terminal block off of
retaining pegs. Carefully pierce a small hole in the
rubber gasket in the centre of the mounting box to
allow the cable to pass through.
•
Use the mounting box as a template and mark the 2
fixings holes, making sure the mounting box is
correctly aligned so that the threaded bolts are
horizontal. Use appropriate fixings to secure the
back plate to the wall.
• Wire as detailed Wiring diagram.
•
Fit the product back on to the mounting box and refit washers
* Product images may vary.
and dome nuts, tighten dome nuts to secure.
•
Fit the bulbs.
•
Replace fuse or circuit breaker and switch on. Your light is now ready for use.
Wiring
Having correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the
terminal block inside the product in the following way:
SUPPLY
NEUTRAL
EARTH (GREEN/YELLOW)
SWITCHED LIVE
LIGHT FITTING
BLUE (N)
GREEN/YELLOW
BROWN (L)
Check that...
• You have correctly identified the wires
• The connections are tight
• No loose strands have been left out
of the connection block
Conformity with all relevant EC Directive requirements.
This is a Class 1 product and must be earthed.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or local store for recycling advice.
This product is rated at IP65.
IP
65
Fitting/replacing bulbs (Max. 7W LED GU10)
When changing a bulb, always switch off at the mains and allow the bulb to cool before handling. Dispose of used bulbs
carefully. Do not exceed the wattage stated or use a different shape bulb from that indicated on the fitting.
Clockwise to engage pins. Finally, refit the lampholder covers. Screw on tightly to
maintain IP protection.
To access the bulb, unscrew the lampholder covers. Turn the bulb one quarter turn anticlockwise
and remove. Push the new bulb gently into the lampholder and twist a quarter turn
Max. 7W LED GU10