Commissioning
• Adjust the cable so it does not get snagged.
• Secure the product to the mounting bracket by
locating the screws through the “L” shaped slots (C)
in the ceiling cover and tightening the screws.
Fitting/replacing bulbs
Instruction leaflet
• Replace fuse or circuit breaker and switch on. Your
light is now ready for use.
Arezzo Triple Plate Spotlight
73685, 73688, 101334
• When changing a bulb, always switch off at the
mains and allow the bulb to cool before handling.
Dispose of used bulbs carefully. Do not exceed the
wattage stated or use a different shape bulb from that
indicated on the fitting.
• Use a soft cloth to handle bulbs, avoid directly
touching the bulbs as this will shor ten their life.
• Remove bulb by turning a quarter turn anticlockwise
and pulling out.
We recommend cleaning with a soft dry cloth.
Do not use solvents or abrasive cleaners as these could
damage the finish.
• Push the bulb gently into the lampholder and twist a
quarter turn clockwise to engage pins.
7W GU10 LED
Recycling advice
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or retailer for recycling advice.
Safety information
For your safety, always switch off the
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg
www.saxbylighting.com
supply before changing lightbulbs, or cleaning.
power
V4 24/12/2021
Saxby Lighting

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of
the connections.
Always use the correct type and wattage bulb.
Exceeding the bulb wattage will damage the product.
When changing a bulb, always switch off at the mains
and allow the old bulb to cool down before handling.
Dispose of used bulbs carefully and responsibly.
This product is suitable for dimming when used in
conjunction with a dimmable lamp. Please ensure
verification of dimming abilities with the lamp
manufacturer prior to use.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
Installation
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting, carefully note the position of each set
of wires.
A
• Undo the screws (C) holding the fixing bracket in
place and set aside.
• Hold the bracket (A) in place and mark the position
of the holes. Ensure that the product is level.
• Ensure the ceiling is capable of holding the weight
roduct. Take care to avoid damaging any
of the p
concealed wiring and pipes. Ensure there is a joist
at the point of fixing to support the weight of the
product.
• Fix bracket into position.
C
B
Wiring
Having correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the
connection block inside the product in the following way:
Specification
Voltage: 220-240V~ 50Hz
Lamp:
IP rating: 20
3 x Max. 7W LED GU10
Layout
• Plan the desired layout of this fitting carefully,
ensuring the cables will reach the distance between
the junction box and the light fitting.
• Avoid locating any cables in positions that would
cause a hazard. Position cables and junction boxes
(not supplied) away from areas where they may be
at risk from being cut, trapped or damaged.
Spotlights give a concentrated beam of light and must not be positioned any closer than 0.5M
(50cm) to the illuminated surface.
• The mains supply cable must have a minimum cross
sectional area of 1.0mm².
• This product must be mounted out of arms reach.
SUPPLY
NEUTRAL
EARTH (GREEN/YELLOW)
SWITCHED LIVE
4th BLOCK PROVIDED FOR LOOP
TERMINATION IF NECESSARY
Check that...
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection
block.
LIGHT FITTING
BLUE (N)
GREEN/YELLOW
BROWN (L)
• When completed, ensure that there are no bare or
loose strands of wire exposed, and cover all exposed
areas of the connection block with 2 layers of