Power LED Green: System has power and is operating normally.
Red: System is in standby mode and most of the controller circuitry is powered down. O: System is not receiving power.
Status LED Green Blinking: Embedded system is ready, but no
communication has been established with the host. Green: Host has established communications with the embedded system. Red Blinking: Embedded firmware is running, but has not received a DHCP IP Address. Red: Host has determined the firmware needs to be updated, but a problem occurred during the process that will initiate a reset. Amber Blinking: Embedded system has a valid link-local IP Address and is connecting to the host.
Amber: Host is updating the embedded firmware. O: Embedded processor is resetting, or is powered
up, and is booting the embedded firmware.
Hardware Failure: If a hardware failure occurs, the status LED indication will be interrupted every three seconds with a solid red indication. For example, if the LED is blinking green when a hardware failure occurs, the LED will alternate between blinking green and solid red at three-second intervals.
RS232 LED Green: RS-232 serial port activity.
O: No RS-232 serial port activity.
IR LED Green: IR port signal activity.
O: No IR port activity.
On/O Button On: Fully enables all internal power rails and processor.
O: Disables most internal power rails and processor, but not internal AC/DC power supply. Hold On/O button for about 5 seconds to place into standby mode. The Power LED turns red. Hold On/O button for about 1 second to take system out of standby mode. The I/O power switch on the back of unit must be On (I) to enable this function. To turn the power o for the entire system, press the I/O power switch on the rear panel to O [O].
Reset Button Resets the network.
Hold Reset Button for 5 seconds while powered On to clear network settings. Status LED will rapidly blink red when reset is complete.
Zone Protection Red: Protection mode has been enabled to protect
a zone/channel; typically indicates thermal protection, clipping or over current.
O: Protection mode has not been enabled.
ENCLOSURE INSTALLATION
The Savant Pro Audio 4 device can be mounted to a Structured Media Enclosure. The Enclosure Brackets need to be attached prior to mounting. For proper ventilation, louvered enclosure doors are recommended. See Pro Audio 4 Deployment Guide for more information.
A
B
E
C
D
F
G
FRONT PANEL
SAVANT PRO AUDIO 4
QUICK REFERENCE GUIDE
BOX CONTENTS – SKU: SMA-5000
(1) Savant Pro Audio 4 (model: SPA-5000-xx) (2) Enclosure Bracket (071-1103-xx) (1) 2U Rack Bracket (071-1102-xx) (1) Power Cord (064-0079-xx) (4) #10x½ Screw (039-0405-xx) (4) Push Rivet (039-0406-xx) (6) M4 Screw (039-0403-xx) (4) 4-pin Speaker Connector (028-0702-xx) (2) 4-pin IR Connector (028-0703-xx) (4) Rubber Feet (074-0655-xx) (4) M3 Feet Screw (039-0407-xx) (1) Quick Reference Guide (this document)
SPECIFICATIONS
ENVIRONMENTS
Temperature 32° to 104° F (0° to 40° C)
Humidity 10% to 80% (non-condensing)
Maximum BTU 750 BTU / HR
DIMENSIONS Height Width Depth Weight
Unit 3.03 in
(7.7 cm)
12 in (30.5 cm)
14.17 in (36.0 cm)
10.6 lb (4.81 kg)
Packaging with contents
8.27 in (21.0 cm)
15.55 in (39.5 cm)
19.41 in (49.3 cm)
15.1 lb (6.85 kg)
Rack Space 2U
POWER
Input Power 100/240V AC (50/60 Hz) 2.7A
Maximum Power 225W
OPERATING PARAMETERS
Rated Power (Speaker Output)
50 WPC at 8 ohms (THD+N < 0.1%) 70 WPC at 8 ohms (THD+N < 1.0%)
Frequency Response
20 Hz – 20 kHz +/
-
0.5 dB, speaker output
Signal-to-Noise Ratio (SNR)
>95 dB, speaker output
Supported Digital Input Formats
44.1 kHz / 48 kHz / 96 kHz at 16-bit / 20-bit / 24-bit resolution
NETWORKING
Supported Standard
IEEE 802.1 AVB/TSN switches IEEE 802.3 Ethernet
REGULATORY
Safety & Emissions FCC Part 15B CE Mark C-Tick UL
RoHS Compliant
MINIMUM SUPPORTED REQUIREMENTS
Release Savant OS: da Vinci 8.2
Hardware Requires pairing with a Savant Smart Host or Pro Host.
MUSIC STREAMING
The Pro Audio 4 has a built-in single stream of Savant Music, which includes popular music streaming services powered by Autonomic MirageOS. (Streaming service fees may apply.)
RACK INSTALLATION
The Savant Pro Audio 4 device can be mounted in a 2U rack style enclosure and is compatible with all standard 19-inch National Electrical Manufacturers Association (NEMA) rack mounts. The 2U Rack Bracket needs to be attached prior to mounting. See Pro Audio 4 Deployment Guide for more information.
C
D
E
F G
A
B
432
1
-
1 +- 2 +
WIRING AND CONNECTIONS
SPEAKER CONNECTIONS
Speaker wiring connections are made using 4-pin Speaker Connectors supplied with the device. The wire slips into the hole and locks with a screw located at the top of the connector. Speaker connectors accept up to 12AWG speaker cable.
NOTE: Wire order shown does not represent any wiring standard. It may be dierent than other models. NOTE: While not shown in the diagram above, Zones 2 to 4 follow the same wiring as Zone 1.
RS-232 CONNECTIONS
Pins 7 and 8 are only required for CTS/RTS handshaking.
IMPORTANT: When wiring to this port, do not connect any wires within the cable that are not required for communication.
NOTE: CTS/RTS handshaking is supported for flow control based on the profile used in the configuration. NOTE: Wire coloring is included to identify the pins used for this connection. Colors shown do not represent any wiring standard.
NOTE: The Pro Audio 4 does not support RS-422/485.
RJ-45 TO DB9 ADAPTERS: Savant oers RJ-45 to DB9 adapters in a variety
of configurations that can be used for RS-232 control.
Refer to the RS-232 Conversion to DB9 and Pinout Application Note located on the Savant Community for more information on RJ-45 to DB9 adapters.
IR WIRING
IR connections are made using 4-pin IR Connectors supplied with the device. The wire slips into the hole and locks with a screw located at the top of the connector.
IMPORTANT: IR Wiring Precautions Ensure that all IR emitters are within 15 feet (4.6 meters) from the controller’s location.
Use of 3rd party blinking IR emitters with Talk Back is not recommended. These types of emitters can draw voltage away from the IR signal that can degrade IR performance.
NOTE: While not shown in the diagram above, IR connections 3 and 4 follow the same wiring as 1 and 2.
REAR PANEL
FCC INTERFERENCE STATEMENT: PRO AUDIO 4
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interferences that may cause
undesired operation.
The changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for CLASS B digital
device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However there is no guarantee that interference will not occur in a particular installation, If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try correct the interference by one or more of the following measures:
Reorient or relocate the receiving circuit dierent from that to which receiver
is connected.
Increase the separation between the equipment and the receiver.
Consult the dealer or experienced radio/TV technician for help.
INDUSTRY CANADA STATEMENT: PRO AUDIO 4
This device complies with Industry Canada license-exempt RSS standard(s). Operation
is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
For product information:
Part # HDH6C001010 3B
© 2016 Savant Systems, LLC. 45 Perseverance Way, Hyannis, MA 02601 Telephone: 508 683 2500
Printed in China. SMA-5000-00, 009-1411-01_00, 161003
savant.com
PIN 1 Right
-
PIN 2 Right +
PIN 3 Left
-
PIN 4 Left +
Use white stripe for positive (+)
PIN 1 IR 1
-
PIN 2 IR 1 +
PIN 3 IR 2
-
PIN 4 IR 2 +
Use white stripe for positive (+)
PIN 1 –
PIN 2 –
PIN 3 –
PIN 4 GND (RS-232)
PIN 5 RXD (RS-232)
PIN 6 TXD (RS-232)
PIN 7 CTS (RS-232)
PIN 8 RTS (RS-232)
RJ-45 CONNECTOR
(Gold pins facing up)
PIN 1 PIN 8
REGULATORY STATEMENTS
Speaker
Connections
(4) Speaker output zones Uses 4-pin Speaker Connectors NOTE: Compatible with 8 ohm or 4 ohm speakers.
Analog Preamp
Output
(1) Analog stereo line output (Left & Right)
Analog Inputs (2) Analog stereo inputs, RCA line-level inputs;
22 kΩ input impedance
Digital Audio
Out
(1) Digital optical preamp output (TOSLINK), line-level 96kHz/24-bit output, fixed volume
Digital Audio In (2) Digital optical audio inputs (TOSLINK).
Supports up to 96kHz/24-bit digital audio in; PCM stereo format only.
IR (4) IR Ports
Uses 4-pin IR Connectors to send IR signals to control devices with an IR input or IR receiver via an IR flasher (5V tolerant only). See IR Wiring section for important precautions regarding IR functionality before making any connections.
RS-232 8-pin RJ-45 port used to transmit and receive serial
binary data to and from serial controllable devices. CTS/RTS handshaking availability based on component profile. See RS-232 Connections section for pin-outs.
Ethernet 8-pin RJ-45 port
10/100/1000 Base-T auto-negotiating port with Link/ Activity LEDs Supports Audio Video Bridging (AVB)
Ethernet
Activity LED
Green Blinking: Activity (Rx/Tx) O: No Activity
Ethernet Link
LED
Green Solid: Ethernet Link is established (any speed) O: Ethernet link is not established
USB USB 2.0 Type A (reserved for future use)
Fuse 250V 3A slow blow fuse; field replaceable
See Pro Audio 4 Deployment Guide for additional information on replacing the fuse.
Power Input 100/240V AC (50/60 Hz) 2.7A
I/O (power
switch)
I (On): Powers On the controller O (O): Powers O the controller
EXPANSION
Up to three Pro Audio 4 units can be connected using AVB compliant switching, providing up to 18 zones of distributed audio (12 amplified zones and 6 preamp zones). See Pro Audio 4 Deployment Guide for additional information.
NETWORK REQUIREMENTS
Connect all Savant devices to the same local area network (LAN) or subnet as the host. Savant recommends not implementing any type of trac or packet shaping in your network topology for the Savant devices as this may interfere with performance.
NETWORK CONFIGURATION
To ensure that the IP Address will not change due to a power outage, a static IP Address or DHCP reservation should be configured. Savant recommends using DHCP reservation within the router. By using this method, static IP Addresses for all devices can be managed from a single UI, avoiding the need to access devices individually.
Setting DHCP reservation varies from router to router. Refer to the documentation for the router to configure DHCP reservation.
Refer to the Pro Audio 4 Deployment Guide (009-1413-xx) located on the Savant Community for more information.
C
D
H
K
L
M
N
I
J
F
G
A
B
E
B D
H
K
MF
C
L
NI JG
A
E
-
R +- L +
Zone 1
432
1
Loading...