Savant DigiFlow 8000T User Manual

| Install batteries
Slide off the cover case of the battery room, and put into 2 AAA batteries. Then slide the cover case back.
| Setting capacity
and timing
DISPLAY
RESET
Keep pressing | button, then press |
button and release both of the buttons. The DigiFlow 8000T will go into setting procedure. The digit will flash to notice you that the setting procedure is on.
> Setting capacity Press IW M ilia fl button to choose the
capacity. The sequence is 0 - 100 - 200 - 300...9800 - 9900 - OFF - 0 -
100. Then press is ia a a a button to save the filter capacity value. Then go into timing setting.
*The capacity mode will be disabled when you choose OFF. » Setting timing
Press lilb ld fe V l button to choose the timing.The sequence is 0 - 30 - 60 - 90...690 - 720 - OFF - 0 - 30. Then press to save the Timing. The setting procedure is completed.
*The capacity mode will be disabled when you choose OFF. *The setting procedure will be terminated, and go back to
DigiFlow 8000T
Users Manual
the original status if there is no input for 10 seconds.
| Connecting fitting
The specification of the DigiFlow 8000T connectors is 3/8NPT female. You could use any 3/8 NPT male connectors.
| Operating
The DigiFlow 8000T will be automatically on when there is any water flowing through the sensor. It will automati cally off when there is no water flowing for 10 seconds .
DISPLAY Press DISPLAY
button:
| button is to display the status of the three modes of the DigiFlow 8000T. showing the capaci ty left. Timing mode:showing the tiniing left.Flow rate mode:showing the current flow rate. The sequence is Flow-Rate-Timing-Capacity...
RESET
button:
Press setting-
RESET
button is to reset the setting to be the last
g/m
Alarm
» Noticing Alarm
When capacity is lower than 30 gallons or timing is
lower than 7 days, the buzzer will beep once and the digit will flash to notice you to prepare changing filter cartridge when there is any water flowing through
DigiFlow 8000T or press the
DISPLAY button.
> Warning Alarm When capacity reaches 0 gallon or timing reaches 0 day, the buzzer will beep twice and the digit will flash to notice you to change the filter changing when there is any water flowing through DigiFlow 8000T or press the
DISPLAY
» Low battery power alert When the battery power lower than normal working level, the buzzer will beep twice to notice you to change thed the battery. The data will be kept in memory when the battery power is run out or battery is removed.