Savant CLI-8000,CLI-8000A Quick Reference Manual

The Savant® CLI-8000 and CLI-8000A eight zone Thermostat Processing Units
Environmental
Temperature
32° to 104°F
Humidity
10% to 90% Relative Humidity (non-condensing)
Dimensions and Weight
12.17 inches (309.12 mm) with cover
Height
11.05 inches (280.67 mm) without cover
15.48 inches (393.19 mm) with cover
Width
14.23 inches (361.44 mm) without cover
2.81 inches (71.37 mm) with cover
Depth
2.71 inches (68.83 mm) without cover
Weight
8.75 lb. / 4.0 kg
Power
Power (Input)
24V AC (40VA) from external transformer Power Draw
CLI-8000 = 12W @ 24V AC
Power Draw (Maximum)
CLI-8000A = 24W @ 24V AC
Cable Requirements
Relay Bank to HVAC system
18 American Wire Gauge (AWG) Standard HVAC wiring (RH, RC, W1, W, Y1, Y2, O, G, Aux)
Cable Requirements (Sensors)
Data Sensor Bus (1-Wire)
24 AWG (Cat 5) 600 feet (182 m) maximum (cumulative) Remote Sensor
24 AWG (Cat 5) 500 feet (152 m) maximum
Compliance
Safety and Emissions
FCC Part 15 RoHS
Compliant
Additional Info
RS-232
Baud Rate = 19200
Item
Description
A
Ethernet
Reserved for Future Use
B
HVAC Relays
Each relay bank or zone gets wired to an HVAC system. The CLI-8000/8000A supports wiring up to eight individual HVAC systems.
C
RS-232
Connect cable from the RS-232 port to a Savant Controller. Communication between the controller and the CLI-8000/8000A is achieved over the RS-232 connection. RS-232 supports 19200 baud.
D
Station Bus
Reserved For Future Use
E
Console
Mini USB (Mini-B) female connector (Serial UART); Debug terminal
F
DSB/1-Wire
The DSB/1-Wire Connector connects to the Data Sensor Bus, which is a serial bus based on the 1­Wire protocol. The CLI-THFM1 smart sensor communicates over the Data Sensor Bus through this connection. Up to two smart sensors per zone can be configured with a total of eight per system.
G
Display/Keypad
Monitors and configures the system. Use the keypad to scroll through the available menus and configure each zone.
H
Remote Sensors
Indoor, Outdoor, Slab, and Plenum two-wire temperature sensors are connected here. A maximum of two per zone is supported.
I
Input Power (Access)
Remove the power input access screw and remove the associated panel. This will give user access to the power supply board for wiring the 24V AC input power.
J
Zone LEDs
The Zone LED’s indicate which zone has been selected via the keypad for configuration.
K
Input Power (24V AC)
System is powered by 24V AC power source. Power cable is fed through ½ inch cable restraint (not included) installed at bottom of box. Input power is wired to a two position screw terminal block on the power supply board.
L
Analog Control
Reserved for Future Use
M
USB
The USB port connects to the optional Android™ based tablet. Communication between the tablet and the CLI-8000A version of TPU is achieved through the USB port.
N
Smart Connect
Maintenance functions such as firmware upgrades are achieved through the Smart Connect connection. Requires SCA-CONF-XX or SCA­CONFL-XX Smart Connect cable.
Thermostat Processing Unit (CLI-8000-00 / CLI-8000A-00)
Quick Reference Guide
Scan this QR code for additional
product information.
009-1090-01
CLI-8000-00
CLI-8000A-00
009-1090-01
31314
Savant Confidential and Proprietary
1of2
(TPU) are at the heart of the Savant® Centralized Climate Control system. Through communications with a number of remote sensors and optional user interfaces, the Thermostat Processing Unit can manage up to eight heating, ventilation, and air conditioning (HVAC) systems. The system is easily integrated with most leading HVAC systems and can be designed as one part of a complete Savant® Control
System solution.
The CLI-8000 version is configured using the keypad and display located on the front panel.
The CLI-8000A version is configured using a climate application loaded onto an Android™ based tablet (Android is a trademark of Google Inc). The tablet, which is installed into the front cover of the TPU, incorporates a touch screen interface with an elegant climate control application for setting up, viewing, and controlling each climate zone independently.
Once installed and configured, either system the can be integrated to add monitoring and control through an iOS device such as iPad® or iPod®.
This Quick Reference Guide provides the information necessary to install the CLI-8000/8000A as well as information on wiring to each of the optional and required components of the Savant HVAC solution.
Box Contents
(1) CLI-8000 or CLI-8000A (Includes all mating connectors from front panel) (1) Samsung Galaxy Tab 3 (CLI-8000A only) (1) Quick Reference Guide (this document)
Related Components
Savant® Host Savant® Controller SSC-0008-XX, SSC-0025-XX External 120V AC to 24V AC Transformer, PWR-2440-XX
Optional Remote Sensors
Savant® SST-TEMP1 - Remote Indoor Sensor Savant® SST-OTEMP1 - Remote Outdoor Sensor Savant® CLI-THFM1 - Remote Humidity/Temperature Smart Sensor Savant® CLI-PLEN1C - Commercial Plenum Sensor (Heat duct sensor) Savant® CLI-PLEN1R - Residential Plenum Sensor (Heat duct sensor) Savant® CLI-SLAB1 - SLAB Sensor (Floor Heating Sensor)
Note: Each zone on the CLI-8000/8000A supports communications with up to four temperature sensors and two humidity sensors.
Specifications
CLI-8000/8000A Front Panel View
Mounting
Relay
Description
RH - Red
Wired to hot side of transformer on heating equipment.
RC - Red
Wired to hot side of transformer on cooling equipment.
W1 - White
Wired to stage 1 heat terminal (W1) on HVAC system.
W2 - Black
Wired to stage 2 heat terminal (W2) on HVAC system.
Y1 - Yellow
Wired to stage 1 cooling terminal (Y1) on HVAC system.
Y2 - Blue
Wired to stage 2 cooling terminal (Y2) on HVAC system.
O - Orange
Wired to (O) terminal on Heat Pump System. Reversing Valve connection.
G - Green
Wired to fan terminal (G) on HVAC system.
C NO NC
C = Common Terminal NO = Normally Open, Connects with C when the Relay is ON. NC = Normally Closed, Connects with C when the Relay is OFF.
Thermostat Processing Unit
(CLI-8000-00/8000A-00) Quick Reference Guide
009-1090-01
CLI-8000-00
CLI-8000A-00
Savant® Centralized Climate Solution CLI-8000/8000A Quick Reference Guide
009-1090-01
313142of
2
Can be either surface mounted using a pair of mounting brackets (SMB-8000-XX) or flush mounted between two 16 inch on center studs. For more information on mounting, refer to the deployment guides for the CLI-8000 (009-1073-XX) or CLI-8000A (009-1154-XX).
Option 1: Mount between studs (Flush Mount)
1. Locate two adjacent studs that are 16 inch on center. If there is drywall, cut to the dimensions below.
2. Slide between studs. On left and right side there are three mounting holes. Screw to inside of studs through these holes.
HVAC Relay Wiring
The figure below is the top view of the eleven position screw terminal connector that is plugged into each relay bank. Ensure all power from both the HVAC and CLI-8000/8000A systems have been removed before making connections.
1. Remove connector from its mate on front panel.
2. Insert correct wire into front of plug using information in the table below.
3. Tighten screw so that wires are clamped inside the connector.
4. Reinsert into the proper relay bank.
5. Wire other side to HVAC system.
Option 2: Optional Brackets (Surface Mount)
1. Screw the mounting brackets to the right and left side of the CLI-8000 using (4) 10-32 x inch FH machine screws.
2. The mounting brackets are 16 inch on center so the TPU can be screwed to two adjacent studs. Locate two adjacent studs that are 16 inch on center.
3. Screw the TPU to the wall through the drywall and into the studs using appropriate self tapping drywall screws or equivalent.
Connect Input Power
1. Remove the access panel by removing the screw holding down the access panel.
2. Locate the ½ inch electrical knockout just below access panel. Remove knockout and install electrical clamp.
3. Connect the 24V AC from transformer to the two position screw terminal block under the power input panel.
NOTE: Since there is no standard for wire colors in HVAC, the colors shown in table are typical. Refer to manufacturers documentation to HVAC system before wiring.
NOTE: If required, RH and RC can be jumped together.
Remote Sensor Connections
Wiring diagram connecting the CLI-THFM1 sensor to the CLI-8000/8000A. Up to two CLI-THFM1 sensors per zone.
Note: Use a minimum of 18 AWG wire when connecting the input power.
Copyright © 2014 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC. All brand names, product names and trademarks are the property of their respective owners. Savant Systems, LLC reserves the right to change product specifications without notice.
In addition to the CLI-THFM1 Smart Sensor described above, other sensors are available. For information on the these sensors, refer to the Quick Reference Guides (QRG’s) for each sensor.
Additional Documentation
Once the CLI-8000/8000A TPU has been installed, the next few steps will need to be followed to get the system up and running:
Wire CLI-8000/8000A to additional HVAC system(s).
• Wire additional remote sensors to the CLI-8000/8000A
• Power on the CLI-8000/8000A
• Update the firmware to latest version (If Required)
• Configure the system to your specific application.
Documentation covering all the above procedures is available in the Savant Portal located at dealers.savantsystems.com
Products > Savant Hardware > Climate Control
Savant® Centralized Climate Control Deployment guide (009-1073-XX, CLI-8000) Savant® Centralized Climate Control Deployment guide (009-1154-XX, CLI-8000A)