sauter LXT240R,LXT250R Quick Reference

1/20505990003 B
Remote control for 4/5 modes (24 V) en
Quick reference
LXT240R/LXT250R
Installation Instructions for the electrician
List of contents
1. Description of the remote control
3. Fixing the remote control
4. Inserting the batteries
5. Addressing the transmitter code on the receiver
6. Selecting the mode
7. What to do if . . .
8. Technical data
B11718
T
Y10166
60 °C
0
140 °F 32
Description of the remote control1
Manual remote control with radio transmitter to control underfl oor heating with 24 V AC receiver
This remote control unit is particularly easy to install. Thanks to its ergonomic and innovative design, it will enable you to save energy as well as providing comfortable operation. This device is used to control the mode for one zone within your installation - or also for the whole installation - from a central point. Two or more units can be installed in the same building so that the heating plant can be divided into specifi ed zones.
Where should you position the remote control?2
You do best to position the remote control unit close to the entrance door, allowing you to select the mode for the entire installation with one simple manual action (Auto, Comfort, Eco, Frost Protection or Climate). You can also install several units and divide your home into various zones (night or day zones, etc.)
Fixing the remote control3
Remove the adjuster knob1. Loosen the screw that is located underneath the adjuster knob2. Remove front piece3. Affi x the mounting plate using two screws,4. horizontally or vertically at a distance of 60 mm Refi t front piece5. Tighten screws6. Refi t adjuster knob7.
1
2
6
3
5
7
4
60
60
B11688
Fig. 1 Fixing the remote control
Inserting the batteries4
B11705
Slide the cover of the battery compartment downwards; insert batteries, observing polarity.
Inserting the batteriesFig. 2
Addressing the transmitter code 5 on the receiver
Establishing a radio link between the remote control (transmitter) and the receiver:
WARNING
The receiver should be opened only by either a qualifi ed electrician or the manufacturer›s service technician.
All safety precautions listed in the receiver‘s operating instructions must be observed. The receiver should not be left unattended when open (unqualifi ed persons, especially children, should be prevented from gaining access to the equipment).
On the receiver, briefl y press the “Memo” button for the relevant 1. channel (1)
the LED then fl ashes. Â
Remove the rotary adjuster knob on the remote control and press 2. the button thereunder (2, 3).
The red lamp then fl ashes and a confi guration signal is  sent. On the receiver, the LED for the relevant channel then  lights up constantly and indicates the switching condition of the output (lit = ON, not lit = OFF). The connection between the thermostat and the receiver isesta blished.
Wait a minute until the addressing of the system has fi nished.3. Carry out a test: on the remote controle, choose fi rst the maximum, 4. then the minimum setting and check if the channel is being activated accordingly.
15
10
2
3
1
B11719
Fig. 3 Addressing the transmitter code on the receiver
Selecting the mode6
B11690
Use the rotary switch on the remote control unit to select the mode. (Auto, Comfort, Eco, Frost Protection, Climate). The attached channels adapt your mode according to your choice.
Selecting the modeFig. 4
. . .
© Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61 - 695 55 55 Fax +41 61 - 695 55 10 www.sauter-controls.com info@sauter-controls.com
Printed in Switzerland
2/2 0505990003 B
Automatic mode
Installation with programmable radio • remote control (LXT340): the installation operates according to the selected programme.
Installation without remote control • (LXT340): the installation operates continuously in Reduced mode.
Comfort mode
Continuous comfort mode, control according to the settings of the remote control units in the individual rooms, e.g. 20 °C.
Reduced mode (eco)
Continuous reduced mode, control according to the settings of the thermostats in the individual rooms minus 3.5 °C. (Example: if Comfort = 20.5 °C, then Eco is 20.5 °C - 3.5 °C = 17 °C). This mode lets you reduce the temperature without having to change the setpoint for Comfort mode.
Frost protection
Control according to a fi xed setpoint (8 °C). This mode offers protection against frost damage during lengthy absences in winter.
Climate
Climate control (e.g. underfl oor heating or cooling) according to the settings of the remote control units in the individual rooms, e.g. 23 °C.
ModesTa b. :
What to do if...7
the LED does not light up during transmissions between the  transmitter and the receiver?
the batteries are fl at, or the wrong batteries were inserted:  replace both batteries, only use type LR03 1.5 V alkaline batteries.
the LED fl ashes continuously? Â
the batteries will soon be fl at: replace both batteries, only use  type LR03 1.5 V alkaline batteries.
the installation does not start up, or does not run  continuously?
the power supply to the receivers has been interrupted: check the  mains fuse or protective switch.
the power supply to the receiver is interrupted? Â
check the mains fuse or protective switch.
the receiver is outside of the transmitter‘s range? Â
move the receiver close enough.
the receiver does not recognise the transmitter code? Â
carry out addressing on the receiver.
the receiver is subject to interference? (e.g. from amateur  radio users, TV screens or mobile phones)
try to move the source of interference or the receiver.
the transmitter is subject to interference? Â
move the transmitter outside of the range of the interference.
Technische Daten8
Power supply 2 alkaline batteries LR03 1.5 V Power consumption
8 µA ruhend, 15 mA beim Senden
Time interval for transmission
1 minute after a change in the setpoint, repeated every 4...10 minutes. Transmitter (frequency 868.3 MHz
Standards
Radio: RTTE immunity: RTTE radiation:
EN 300220 EN 301489-3 EN 300220-3
Ambient conditions:
operation: between 0°C and 60°C• humidity: 25°C 80% (without condensate)• IP 20 (EN 60529)
NOTICE
Important: this remote control unit is a component of the complete radio system, and is intended for use with „intelligent” 24 V AC receivers