sauter FP Series Instruction Manual

Sauter GmbH
Ziegelei 1 D-72336 Balingen E-Mail: info@sauter.eu
Instruction Manual Diagram Force Gauge
SAUTER FP
Version 1.0
01/2016 GB
PROFESSIONAL MEASURING
FP-BA-e-1610
GB
SAUTER FP
Version 1.0 00/2016
Instruction Manual Diagram Force Gauge
Thank you for buying a SAUTER digital Diagram Force Gauge. This force gauge is compact and convenient, suitable for tension and compression measurement appli­cations. It is small sized, low in weight, multifunctional, high in accuracy and the force curve is displayed on the screen. Combined with test stands and clamps you will get a complete measurement system for a wide range of applications. We hope you will pleased with your high quality instrument and with its large func­tional range. Before first use, please read this manual carefully regarding all function applications and for getting reliable measurement results. If you have any queries, wishes or helpful suggestions, do not hesitate to call our service number.
Summary:
1 Parameters ................................................................................................. 3
2 Features ..................................................................................................... 5
3 Names of items, buttons and functions..................................................... 6
3.1 Fast operating guide ................................................................................................ .............. 7
4 Function and introduction into details ...................................................... 8
4.1 Configuration needed for software installation ................................................................. 14
4.2 Software installation and use .............................................................................................. 14
5 Rechargeable Battery .............................................................................. 22
6 Maintenance ............................................................................................. 23
7 Packing list .............................................................................................. 23
8 Declaration of Conformity ....................................................................... 24
2 FP-BA-e-1610
1 Parameters
Capacity and sensor types: FP 2N up to FP 500N with integrated force sensor FP 1KN up to 50 KN with external force sensor
Display: 240x320 Pixel TFT 65535 Color screen
Units: N, kgf, lbf, ozf
Accuracy: within +/- 0.5%
Power: Adaptor: DC 12V/400mA, battery inside: Ni-MH 7.2V, 1200mAH Battery life: ≥ 300 times of charging
Operation time: continuous use for about 6 hours
Standby time: about 3 months
Dimensions in mm: 238*69*36
FP-BA-e-1610 3
Internal measurement frequency: 2.000 Hz
Overload protection: 150% of max
Application in use with following SAUTER test stands: TVP, TVP-L, TVL, TPE, THM, TVO, TVM-N, TVS
4 FP-BA-e-1610
2 Features
Peak/real time value/force curve is displayed on the screen simultaneously, Monitor and track testing procedure.
Upper and lower limit setting and judgment, buzzer alarm inside
Turnover display
3 groups curve storage
70 peaks and real-time values storage
Four units option: N/kgf/lbf/ozf
Peak hold, automatic peak zero
Material strength measurement by inputting area
Shutdown design without any operation
Adaptation to several SAUTER test stands, automatic stop after reaching the pre-set force
USB output, multiple test mode options after connecting to a computer, infinite data storage/ transmitting, curve details view, user defined test report
Environmental working conditions:
Working temperature: 20°C+/- 10°C
Relative humidity: 35RH up to 65% RH
No shocks and corrosives around
FP-BA-e-1610 5
3 Names of items, buttons and functions
6 FP-BA-e-1610
3.1 Fast operating guide
FP-BA-e-1610 7
4 Function and introduction into details
1) Turn on power by pressing button. The instrument will start a self checking program. After “SAUTER and model name” is displayed on the screen, it gets into working state (see picture 7). If the screen shows , this means a lack of electricity. You have to charge the gauge as follows: insert the adaptor to 220V/50Hz at one end and on the other connect it with the charging hole in the gauge. ”flickering means “charging”, if it stops flickering, charging is finished. The gauge can be charged under ON/OFF state and it can also be used while charging. If a grip is installed with the sensor and the grip weight does not exceed 5% of the load capacity, the gauge cleans zero automatically. If the grip weight exceeds 5% over the load capacity, this may lead to a wrong measuring result displayed and you should change to choose a light grip. Turn off: While power is turned on, you have to press ON/OFF to turn power off, or wait for an Auto-turn-off according to the pre-set power-off time before testing.
2) Equipe connector: choose the correct connector accessories or clamps and fix them by screwing. Attention: don’t use too much force to screw - this could damage the sensor. See the connector size down below, Pic. 5
3) Parameter setting interface Press to enter into parameter setting in the initial interface, see below, Pic. 6:
Explication of Picture 6:
8 FP-BA-e-1610
Loading...