Sauter FK 10, FK 25, FK 50, FK 100, FK 250 User guide

...
Instruction Manual
Thank you for buying a SAUTER force gauge. We hope you are pleased with your high quality force gauge with its big functional range. If you have any queries, wishes or helpful suggestions, do not hesitate to call our service number.
„Sensor Inside“ means the measuring cell is inside the housing.
1.
Included in delivery
- SAUTER FK
- Charger
- Standard Attachments as shown below
LCD
Force Sensor
83 mm
195 mm
S
S
i
FK
Terms: Track = continuous measurement Peak = Capture of the maximum value
Data in mm
2.
Working Conditions
10°C to 30°C / 15% up to 80% humidity
3.
Electrical Power Supply
Either by recharchable battery or current power supply
Current power supply:
- Connection by power adapter
- Recharchable batteries are charged simultaneously
Recharchable battery pack for mobile applications:
- Type: AA Size 6 Batteries
- Charging time: approx 1 hour
4.
Technical Data
- Accuracy: ± 0,5 % of Capacity
- Data Sampling Rate: 1.000 Hz
Model Capacity Resolution
FK 10 10 N 0,005 N FK 25 20 N 0,010 N FK 50 50 N 0,020 N FK 100 100 N 0,050 N FK 250 200 N 0,100 N FK 500 500 N 0,20 N FK 1k 1 000 N 0,50 N
Sensor
Inside
w
AS, 03.04.2008 FK GB.doc Page 1 of 3
Instruction Manual
5.
Operation
a. Display
(1) Measuring Result (2) Measuring Units (3) Measuring Direction (4) Indication of PEAK Mode
b. Operating keys
ON / OFF:
MAX:
Changes between Track and Peak mode (capture of maximum values)
UNIT:
- Press short: Select unit:
ZERO:
- Zeros the measuring result (Tara function)
- Cleans the peak value (in Peak mode)
c. Display Return
When the instrument itself is turned so that the head faces down, the display returns automatically.
d. Measurement (Track Modus)
Display (1) shows the continuous force in a defined direction (3)
ON / OFF key (For ON, press 1 sec.)
N, kg, lb, ou
To zero the display, press:
(4) (3)
(1)
(2)
S
FK
e. Peak-Hold Function (Peak Mode)
Please press:
6.
Backside Fixing to a test stand
Fixing by 4 x M3 scres.
7.
CE Declaration of Conformity
S
i
w
AS, 03.04.2008 FK GB.doc Page 2 of 3
Instruction Manual
8. Warning
2.1 Intended use The instrument you have acquired serves to determine the measuring value of the material to be measured. It is intended to be used as a “non-automatic“ instrument, i.e. the material to be measured is manually and carefully attached at the instrument. The measuring value can be read off after a stable measuring value has been obtained.
2.2 Inappropriate use Do not use the instrument for dynamic measuring. In the event that small quantities are removed or added to the material to be measured, incorrect measuring results can be displayed due to the “stability compensation“ in the instrument. (Example: Slow draining off of liquid from a container suspended from the instrument). Do not attach a continuous load. This can damage the measuring unit as well as the parts, relevant to safety.
Prevent jolts, torsion and oscillation (e.g. by appending slopingly) of all kinds. Be sure to prevent overloading the instrument in excess of the stated maximum load (max.), minus any tare weight that may possibly exist. This could damage the instrument (risk of breakage). Important:
• Always make sure that there are no people or materials below the load that could be injured or damaged!
• The instrument is not suitable for measuring people. Do not use as baby scales!
• The instrument does not comply with the medical product law (MPG). Never operate the instrument in hazardous locations. The series design is not explosion-proof. Structural alterations may not be made to the instrument. This can lead to incorrect measuring results, faults concerning safety regulations as well as to destruction of the instrument. The instrument may only be used in compliance with the described guidelines. Varying areas of application/ planned use must be approved by SAUTER in writing.
2.3 Guarantee The guarantee is not valid following
• non-observation of our guidelines in the operating instructions
• use outside the described applications
• alteration to or opening of the device
• mechanical damage and damage caused by media, liquids
• natural wear and tear
• inappropriate erection or electric installation
• overloading of the measuring equipment
2.4 Monitoring the test substances
S
S
i
FK
The metrology features of the instrument and any possible available adjusting weight must be checked at regular intervals within the scope of quality assurance. For this purpose, the answerable user must define a suitable interval as well as the nature and scope of this check. Information is available on the home page (www.KERN-sohn.com) with regard to the monitoring of instrument test substances and the test weights required for this. Test weights and instruments can be adjusted quickly and at a reasonable price in KERN’s accredited DKD calibration laboratory (return to national normal).
3. Fundamental safety information Do not use the hanging instrument to transport loads. Prevent jolts, torsion and oscillation (e.g. by appending slopingly) of all kinds. Never use the hanging instrument over the maximum permitted weight (!!Danger of breaking!!). Always make sure that there are no living beings or materials below the load that could be injured or damaged. The hanging electronic instruments from the SAUTER instrument are only suitable for hand-held use or use in a test stand. They are not suitable for hanging from a mechanical hook, e.g. a crane hook.
3.1 Observe the information in the operating instructions Please read the operating instructions carefully before erecting and commissioning, even if you already have experience with SAUTER instruments.
3.2 Staff training The device may only be operated and looked after by trained members of staff.