Saunier duval THELIA 30 E User Manual

THELIA 30 E
IN WARRANTY
TECHNICAL HELPLINE
01773 828400
01773 828100
THIS IS A CAT II 2H3 APPLIANCE
1
INSTALLATION AND OPERATING INSTRUCTIONS
THELIA 30 E
Note!
The boiler serial number is marked on the label attached to the top of the inner bulkhead. Refer to
the 'Introduction' section page 3 for a description of the basic functions of the boiler. The 'Users'
section describes how to safely operate the boiler.
USERS SECTION
Commissioning ......................................................... 3
Controls & lighting ....................................................4
Draining ..................................................................... 4
Servicing/maintenance .......................................... 4
INSTALLATION SECTION
Introduction.................................................. Page 3
Dimensions ............................................................. 5
Boiler schematic .................................................... 5
Technical data ...................................................... 6
Boiler connections................................................. 7
Piping system installation...................................... 7
Boiler location ........................................................ 8
Heating system design ......................................... 9
Domestic hot water system design..................... 9
Boiler installation .................................................... 9
Flue installation ............................................. 10 - 11
Electrical installation ........................................... 12
Commissioning ............................................. 13 - 14
Operating safety devices .................................. 14
Settings.................................................................. 15
Changing gas type ............................................. 15
Mandatory warning for CEE countries Warning: This appliance was designed, approved and inspected to meet the requirements of the English
market. The identification plate located on the inside of the appliance certifies the origin where the product was manufactured and the country for which it is intended. If you see any exception to this rule, please contact your nearest Saunier Duval dealer. Thank you in advance for your assistance.
2
INTRODUCTION
The THELIA 30 E boiler is a wall mounted combina- tion boiler providing central heating and instanta­neous hot water.
The boiler is of the II 2H3 category for use with Natu­ral Gas (G20) as distributed in the United Kingdom, or Butane (G30), Propane (G31) or Towns gas (G130).
Boilers burning LPG or similar gases MUST NOT be fitted in basements or below ground level.
The boiler has a fan assisted balanced flue which both discharges the products of combustion to and draws the combustion air from the outside of the room. The boiler is suitable for top outlet flue connection only but, can be fitted with horizontal flue, vertical flue or twin-pipe flue. Refer to flue catalogue for further details.
Both the central heating and domestic hot water temperature are user adjustable from the boiler control panel.
Domestic hot water demand always has priority over heating demand. The boiler is designed for use as part of a sealed water central heating system with fully pumped cir­culation. The pump, expansion vessel and associ­ated safety devices are all fitted within the boiler.
The boiler can be installed against either an exter­nal wall or on an adjacent inside wall, that is, the flue system will pass directly to the rear or to either side to the terminal fitted on the outside wall face.
The installation must be carried out by a compe­tent person in accordance with the relevant re­quirements of The Building Regulations, The Water Byelaws, The Building Standards (Scotland) Regu­lations and any applicable local regulations.
These instructions should be carefully followed for the safe and economical use of your boiler.
Ancillary equipment
A range of flue accessories are available includ­ing vertical flues, twin-pipe flues, bends etc. For further information contact your supplier.
COMMISSIONING
Gas safety (Installation and Use) Regulations In your interests and that of gas safety, it is the law that ALL gas appliances are installed and serviced by a competent person in accordance with the above regulations.
Gas leak or fault
If a gas leak or fault exists or is suspected, turn the boiler off and consult the local gas supply com­pany or your installation/service company.
Diagram 1
A
A-Pressure gauge B-Temperature gauge
C-Reset button
D-N/A on this model
E-Mains 'ON' warning light F-Loss of water warning light
B
C
DE
F
Boiler controls
The control panel, located at the lower front of the boiler casing, see diagram 1, allows the boiler to be started, shut down, controlled and monitored during use.
Flue
Do not obstruct the outside terminal of the boiler.
G -N/A on this model H-Safety shutdown warning light
I-Domestic hot water temperature control J-Heating temperature control
K-'Summer/winter' selector
L-N/A on this model
G
H
I
J
K
L
bar
0
Hab 031a
3
CONTROLS AND LIGHTING
Starting the boiler
Before starting the boiler check that:
• The gas meter tap is open.
• The boiler gas service cock is open.
• The boiler is connected to the electrical supply and turned on.
Setting to SUMMER mode (Hot water only)
• Turn the OFF/Summer/Winter' switch (K) to the 'Summer' position, see diagram 1.
• Turn the domestic hot water temperature con­trol (I) to the desired setting, see diagram 1.
To obtain domestic hot water, open a hot water tap. Hot water always has priority over central heating.
DRAINING
Protection against freezing
If the boiler is to be out of use for any long periods during severe weather conditions, it is recom­mended that the whole system, including the boiler, be drained to avoid the risk of freezing. If in doubt, consult your servicing company.
The THELIA 30 E boiler has a built in frost protection device that protects the boiler from freezing. If the boiler is to be left and there is a risk of frost, ensure that the gas and electrical supplies are left con­nected and that the OFF/Summer/Winter switch is left in the'Summer' or 'Winter' position.The frost pro­tection device will light the boiler when the tem­perature of the boiler water falls below 6°C. When the temperature reaches 16°C, the boiler stops. Note: This device works irrespective of any room thermostat setting and only protects the boiler. Al­ways ensure that adequate frost protection is given to the entire system where necessary.
Draining and filling
Setting to WINTER mode (Heating and hot water)
• Turn the OFF/Summer/Winter selector switch to (K) to the 'Winter' position, see diagram 1.
• Turn the central heating temperature control (J) to the desired setting, see diagram 1.
• Turn the domestic hot water temperature con­trol (I) to the desired setting, see diagram 1.
• Make sure that any external controls are calling for heat. The heating system will begin to heat up.
To obtain domestic hot water, open a hot water tap. Hot water always has priority over central heating.
Caution: The boiler is installed as part of a sealed system which must only be drained and filled by a competent person.
Heating safety valve CAUTION: A safety valve with a discharge pipe is
fitted to this boiler. The valve MUST NOT BE TOUCHED except by a com­petent person. If the valve discharges at any time, switch the boiler off and isolate it from the electri­cal supply. Contact your installation/service com­pany.
SERVICING/MAINTENANCE
To ensure the continued efficient and safe opera­tion of the boiler, it is recommended that it is checked and serviced at regular intervals. The fre­quency of servicing will depend upon the installa­tion conditions and usage but, in general, once a year should be enough.
Cleaning
The boiler casing can be cleaned with a damp cloth followed by a dry cloth to polish. Do not use abrasive or solvent cleaners.
4
Boiler casing CAUTION. Do not remove or adjust the casing in
any way, as incorrect fitting may result in faulty op­eration. If in
DIMENSIONS
Diagram 2
The boiler is delivered in three separate packages:
- The boiler itself
- The fixing jig
- The flue system
For flue systems greater than 1 m long, remove the cup restrictor from the boiler flue outlet.
between 0,5 and 1,5 m
fit diaphragm (a)
seal
a - diaphragm
217
260
Ø 100
80
889
BOILER SCHEMATIC
Diagram 3
1-Bypass 2-Loss of water pressure switch 3-Pump 4-Automatic air vent 5-Expansion vessel 6-Injector manifold 7-Ignition electrode 8-Expansion vessel filling valve
9-Overheat thermostat 10 - Heat exchanger 11 - Fan 12 - Air pressure switch 13 - Automatic air vent 14 - Flame sense electrode 15 - Thermostatic valve 16 - 3-way valve 17 - Gas valve 18 - Water valve 19 - Safety valve (3 bar) 20 - Domestic hot water expansion
vessel
A - Heating return
B - Cold water inlet
C - Heating flow D - Domestic hot water flow
E - Gas supply
14
13
12
11
10
393
520
Net weight : 55 kg Gross weight : 57 kg