To display target set point, select a parameter or confirm an operation in programming
mode.
To start a manual defrost
To view the last alarm occurrence; in programming mode, it browses the parameter
codes or increases the display value
To view the last alarm occurrence; in programming mode, it browses the parameter
codes or decreases the display value
KEY COMBINATION
To lock & unlock the keyboard
To enter in programming mode
To return to the room temperature display
1.1 Function of LEDS
2. MAIN FUNCTIONS
2.1 HOW TO VIEW THE SET POINT
1. Push and immediately release the SET key: the display will show the set point value.
2. Push and immediately release the SET key or wait for 5 seconds to display the
sensor value again.
2.2 HOW TO CHANGE THE SET POINT
1. Push the SET key for more than 2 seconds to change the set point value.
2. The value of the set point will be displayed and the LED starts blinking.
3. To change the set value, push the or key within 10s.
4. To set new point value, push the SET key again or wait 10s.
2.3 HOW TO START A MANUAL DEFROST
Push the key for more than 2 seconds and a manual defrost will start
2.4 HOW TO LOCK THE KEYBOARD
1. Hold the and keys for more than 3s.
2. The “POF” message will be displayed and the keyboard will be locked. At this point, it will be
3. ALARM SIGNALS
HOW TO VIEW THE ALARM AND
RESET THE RECORDED ALARM
1. Hold the or key to
display the alarm signals.
2. When the signal is displayed,
hold the SET key until the “rst”
message is displayed. Push the
SET key again. The “rst” message
will start blinking and the normal
temperature will be displayed again.
6. REPLACEMENT OF MAIN COMPONENTS
6-1. BOTTOM PANEL PARTS
6-1-1. UNSCREW BOTH SIDES OF THE BOTTOM PANEL
6-1-2. PULL THE BOTTOM PANEL OUT
6-1-3. UNSCREW THE JUNCTION BOX
6-2. DOOR CHANGING
6-2-1. UNSCREW THE BOTTOM HINGE
6-2-2. PULL DOWN DOOR
6-2-3. CHANGE THE DOOR HINGE.
A. PUT THE DOOR ON A FLAT LEVEL
B. UNSCREW THE HINGE
C. PULL OUT THE SPRING HINGE
6-3. REFRIGERATION COMPARTMENT PARTS
6-3-1. BEFORE OPENING THE REFRIGERATION COMPARTMENT, PLEASE TAKE ALL THE PANS
OUT AND TAKE THE PAN SUPPORT OFF
6-3-2. TAKE THE SHELVES, K SHAPE CLIPS AND SENSOR OFF
6-3-3. UNSCREW THE EVAPORATOR COVER
6-3-4. TAKE OFF THE EVAPORATOR COVER
6-3-5. CHANGE EVAPORATOR AND WATER PAN
A. UNSCREW THE EVAPORATOR
B. BEFORE CHANGING THE EVAPORATOR, CUT OFF THE EVAPORATOR PIPE AND
DISCONNECT THE WIRE TO THE SENSOR
C. UNSCREW THE SCREWS FOUND AT THE TOP OF THE EVAPORATOR, AND DISCONNECT
IT. REPLACE THE EVAPORATOR AND REATTACH THE PIPE AND CONNECT THE SENSOR
WIRES
6-4. CONDENSING UNIT
6-4-1. TAKE OFF THE BACK COVER
6-4-2. UNSCREW THE UNIT BOARD. YOU CAN PULL THE UNIT BOARD OUT FOR ANY
REPAIRS OR CLEANING
CAUTION: BE CAREFUL OF ELECTRIC SHOCK.
CAUTION: MAKE SURE THE POWER SUPPLY IS CUT OFF