Fluorescent
Ballasts


Ballasts
Electronic Ballasts
T2 Subminiature, Programmed Start, < 15% THD, Universal Voltage Ballasts
Primary
Lamp
Type
FM13
No of
Lamps
Input
Voltage
1 / 2 120/277 S5246
T5 Programmed Start, < 10% THD, Universal Voltage Ballasts
Primary
Lamp
Type
FP28T5
No of
Lamps
Input
Voltage
1 120/277 S5221
2 120/277 S5222
Satco
Product
Number Ballast Code
QT-FM 50 Wiretap Connectors
S
Listed for 1 or 2 FM6, FM8, FM11, FM13 Lamp(s)
Satco
Product
Number Ballast Code
QTP1X28T5/UNIV/PSN/NL 20 Wiretap Connectors
S
QTP2X28T5/UNIV/PSN/NL 20 Wiretap Connectors
S
Listed for FP14, FP21, FP28, FP35
Pkg
Qty
Pkg
Qty
Wiring
Method
Wiring
Method
ballasts
T5HO Programmed Start, < 10% THD, Universal Voltage Ballasts
Primary
Lamp
TypePrp
FP24T5
FP54T5
FP80T5
No of
Lamps
1 120/277
2 120/277
1 120/277
2 120/277
1 120/277
Input
Voltage
Satco
Product
Number Ballast Code
S5214
S5215
Listed for FPC22T5, FP24T5HO, FT24DL, CF24DF, FT36DL, CF36DL, FP39T5HO, FPC40T5
S5218
S5219
Listed for FP54T5/HO, FT55DL, FPC55
S5220
Listed for FP80T5/HO, FT80DL
QTP1X39/24T5HO/UNV/PSN/NL 20 Wiretap Connectors
S
QTP2X39/24T5HO/UNV/PSN/NL 20 Wiretap Connectors
S
QTP1X54T5HO/UNV/PSN/NL 20 Wiretap Connectors
S
QTP2X54T5HO/UNV/PSN/NL 20 Wiretap Connectors
S
QTP1X80T5HO/UNV/PSN/NL 20 Wiretap Connectors
S
Pkg
Qty
Wiring
Method
Have a special requirement? Visit our website at www.satco.com
135

Ballasts
Electronic Ballasts
T8 Instant Start, Standard <20% THD, Dedicated Voltage Ballasts
Primary
Lamp
Type
F32T8
ballasts
No of
Lamps
Input
Voltage
1 120v S6623
277v S6633
2 120v S6624
277v S6634
3 120v S6625
277v S6635
4 120v S6626
277v S6636
Satco
Product
Number Ballast Code
QT1X32T8/120/ISN/SC 10 Leads
S
QT1X32T8/277/ISN/SC 10 Leads
S
QT2X32T8/120/ISN/SC 10 Leads
S
QT2X32T8/277/ISN/SC 10 Leads
S
QT3X32T8/120/ISN/SC 10 Leads
S
QT3X32T8/277/ISN/SC 10 Leads
S
QT4X32T8/120/ISN/SC 10 Leads
S
QT4X32T8/277/ISN/SC 10 Leads
S
Listed for FBO16, FO17, FBO24, FO25, FBO31, FO32, FBO32, FO40 & SS Equivalents
Can operate 1 lamp on 2 lamp ballast, 2 lamps on 3 lamp ballast, 3 lamps on 4 lamp ballast
For F40T8 operation use 1 lamp on a 2 lamp ballast, 2 lamps on a 3 lamp ballast,
or 3 lamps on a 4 lamp ballast
Pkg
Qty
Wiring
Method
T8 Instant Start, Professional <10% THD, Universal Voltage Ballasts
Primary
Lamp
Type
F32T8
No of
Lamps
Input
Voltage
1 120/277 S5207
2 120/277 S5208
3 120/277 S5209
4 120/277 S5210
Satco
Product
Number Ballast Code
QTP1X32T8/UNIV/ISN/SC 10 Leads
S
QTP2X32T8/UNIV/ISN/SC 10 Leads
S
QTP3X32T8/UNIV/ISN/SC 10 Leads
S
QTP4X32T8/UNIV/ISN/SC 10 Leads
S
Listed for FBO16, FO17, FBO24, FO25, FBO31, FO32, FBO32, FO40 & SS Equivalents
Can operate 1 lamp on 2 lamp ballast, 2 lamps on 3 lamp ballast, 3 lamps on 4 lamp ballast
For F40T8 operation use 1 lamp on a 2 lamp ballast, 2 lamps on a 3 lamp ballast, or 3 lamps
on a 4 lamp ballast
Pkg
Qty
Wiring
Method
T8 Programmed (Rapid) Start, Professional <10% THD, Universal Voltage Ballasts
Primary
Lamp
Type
F32T8
No of
Lamps
Input
Voltage
1 120/277 S5286
2 120/277 S5287
3 120/277 S5288
4 120/277 S5289
Satco
Product
Number Ballast Code
QTP1X32T8/UNIV/PSN/TC 10 Leads
S
QTP2X32T8/UNIV/PSN/TC 10 Leads
S
QTP3X32T8/UNIV/PSN/SC 10 Leads
S
QTP4X32T8/UNIV/PSN/SC 10 Leads
S
Listed for FBO16, FO17, FBO24, FO25, FBO31, FO32, FBO32 & SS Equivalents
Can operate 1 lamp on 2 lamp ballast, 2 lamps on 3 lamp ballast, 3 lamps on 4 lamp ballast
Pkg
Qty
Wiring
Method
136
Customer Service 1-800-43-SATCO

Ballasts
Electronic Ballasts
T8 Instant Start, Standard <20% THD, Dedicated Voltage Ballasts
Primary
Lamp
Type
F96T8
No of
Lamps
Input
Voltage
2 120v S5211
2 277v S5212
Satco
Product
Number Ballast Code
QT2X59/120/IS 10 Leads
S
QT2X59/277/IS 10 Leads
S
Listed for FO96T8 and SS equivalents
Can operate 1 lamp on 2 lamp ballast
Pkg
Qty
Wiring
Method
T8 Instant Start, Professional <10% THD, Universal Voltage Ballasts
Primary
Lamp
Type
F96T8
No of
Lamps
Input
Voltage
2 120/277 S5213
Satco
Product
Number Ballast Code
QT2X59T8/UNIV/ISN/SC 10 Leads
S
Listed for FO96T8 and SS equivalents
Can operate 1 lamp on 2 lamp ballast
Pkg
Qty
Wiring
Method
T12 Rapid Start, < 10% THD, Dedicated Voltage Ballasts
Primary
Lamp
Type
F40T12
No of
Lamps
Input
Voltage
1 120 S5258
2 120 S5260
3 120 S5262
Satco
Product
Number Ballast Code
QTP1X40T12/120/RSN B 20 Leads
S
277 S5259
277 S5261
277 S5263
Listed for F34T12, FB34T12, F40T12, FB40T12, F40T10
QTP1X40T12/277/RSN B 20 Leads
S
QTP2X40T12/120/RSN B 20 Leads
S
QTP2X40T12/277/RSN B 20 Leads
S
QTP3X40T12/120/RSN B 20 Leads
S
QTP3X40T12/277/RSN B 20 Leads
S
Pkg
Qty
Wiring
Method
ballasts
FT40DL Instant Start, <20%THD, Dedicated Voltage Ballasts
Primary
Lamp
Type
FT40DL
No of
Lamps
Input
Voltage
1 120 S5240
2 277 S5241
1 120 S5242
2 277 S5243
1 120 S5244
2 277 S5245
Have a special requirement? Visit our website at www.satco.com
Satco
Product
Number Ballast Code
QT1X40/120/DL 10 Leads
S
QT1X40/277/DL 10 Leads
S
QT2X40/120/DL 10 Leads
S
QT2X40/277/DL 10 Leads
S
QT3X40/120/DL 10 Leads
S
QT3X40/277/DL 10 Leads
S
Pkg
Qty
Wiring
Method
137

Ballasts
Electronic Ballasts
Compact Fluorescent Programmed Start, <10%THD, Universal Voltage Ballasts
Primary
Lamp
Type
CF13
No of
Lamps
Input
Voltage
1 / 2 120/277 S5223
Satco
Product
Number Ballast Code
QTP1/2X13CF/UNV/BS 20 Wiretap Connectors
S
S5225
Listed for 1 or 2 CF13DD/E or CF13DT/E lamp(s)
QTP1/2X13CF/UNV/TS 20 Wiretap Connectors
S
Pkg
Qty
Wiring
Method
CF18
CF26
ballasts
CF26
CF26
CF57
1 / 2 120/277 S5226
S5228
Listed for 1 or 2 CF18DD/E or CF18DT/E Lamp(s)
1 / 2 120/277 S5229
S5231
Listed for 1 or 2 CF26DD/E, CF26DT/E, FPC22T5, FT24DL, CF24DF Lamp(s)
Also Listed for 1 ea CF32DT/E, CF42DT/E, F28/2D, F38/2D, FPC40T5, FT40DL Lamp
Also Listed for 2 ea CF13DS/E, FT18DL/RS, CF18DF, F21/2D Lamps
1 / 2 120/277 S5232
S5233
S5234
Listed for 1 or 2 CF26DD/E or CF26DT/E Lamp(s)
Also Listed for 1 ea CF32DT/E or CF42DT/E
2 120/277 S5235
S5236
S5237
Listed for 2 ea CF26DT/E, CF32DT/E, CF42DT/E, FT36DL, FT40DL, FPC40T5 Lamps
Also Listed for 1 ea FPC22T5 plus FPC40T5 Lamps (must use both lamps together)
1 120/277 S5238
S5239
Listed for 1 ea CF57DT/E or CF70DT/E Lamp
QTP1/2X18CF/UNV/BS 20 Wiretap Connectors
S
QTP1/2X18CF/UNV/TS 20 Wiretap Connectors
S
QTP1/2X26CF/UNV/BS 20 Wiretap Connectors
S
QTP1/2X26CF/UNV/TS 20 Wiretap Connectors
S
QTP1/2CF/UNV/BM 20 Wiretap Connectors
S
QTP1/2CF/UNV/PM 18 Wiretap Connectors
S
QTP1/2CF/UNV/TM 18 Wiretap Connectors
S
QTP2X26/32/42CF/UNV/BM 20 Wiretap Connectors
S
QTP2X26/32/42CF/UNV/PM 18 Wiretap Connectors
S
QTP2X26/32/42CF/UNV/TM 18 Wiretap Connectors
S
QTP1X57CF/UNV/BM 20 Wiretap Connectors
S
QTP1X57CF/UNV/PM 18 Wiretap Connectors
S
138
Plastic Enclosure Styles (S)
BS = Bottom Mount for
recessed downlight
fixtures
TS = Top Mount for
ceiling and wall
sconce installation
Customer Service 1-800-43-SATCO
Metal Enclosure Styles (S)
BM = Bottom Mount for
recessed downlight
fixtures
PM = Bottom Mount with
PEM studs for recessed
downlight fixtures
TM = Top Mount with PEM
studs for ceiling and
wall sconce installation

Ballasts
Electronic Ballasts
T4 4-Pin CF-L Socket and Electronic Ballast Combination
Featuring New TwistLock Protection
Lamp
Wattage(s)
13
Satco
Product
Number MOL MOD
80/1384
80/1325
Short 13 Watt Socket
Standard 13 Watt Socket
2.12” 2.00” x 2.37” Ivory 200/25 1/8” IPS Hickey UL1015 24”
3.00” 1.75” Ivor y 200/25 1/8” IPS Hickey UL1015 24”
Finish
Master /
Inner Pack
Mounting
Method
Wire
Spec
Lead
Length
18
26
26-32-42
80/1405
80/1335
C-UL Listed for Indoor/Outdoor applications Minimum Starting Temp -20 C / -4 F
80/1385
80/1324
80/1406
80/1336
C-UL Listed for Indoor/Outdoor applications Minimum Starting Temp -20 C / -4 F
80/1386
80/1383
80/1382
C-UL Listed for Indoor/Outdoor applications Minimum Starting Temp -20 C / -4 F
80/1323
C-UL Listed for Indoor/Outdoor applications Minimum Starting Temp -20 C / -4 F
Standard 13 Watt Socket
13 Watt Socket With Uno Ring
Short 18 Watt Socket
Standard 18 Watt Socket
Standard 18 Watt Socket
18 Watt Socket With Uno Ring
Short 26 Watt Socket
Standard 26 Watt Socket
26 Watt Socket With Uno Ring
26/32/42 Watt Socket
2.37” 1.75” Ivor y 200/25
1.88” 1.75” Ivor y 200/25 1/8” IPS Hickey UL1015 24”
2.12” 2.00” x 2.37” Ivory 200/25 1/8” IPS Hickey UL1015 24”
3.00” 1.75” Ivor y 200/25 1/8” IPS Hickey UL1015 24”
2.37” 1.75” Ivor y 200/25
1.88” 1.75” Ivor y 200/25 1/8” IPS Hickey UL1015 24”
2.12” 2.00” x 2.37” Ivory 200/25 1/8” IPS Hickey UL1015 24”
3.00” 1.75” Ivor y 200/25 1/8” IPS Hickey UL1015 24”
1.88” 1.75” Ivor y 200/25 1/8” IPS Hickey UL1015 24”
3.12” 2.50” Ivor y 200/25 1/8” IPS Hickey UL1015 24”
Rt Angle Snap In
Rt Angle Snap In
UL1015 24”
ballasts
UL1015 24”
26 - 32
80/1331
C-UL Listed for indoor applicatons
Dimmer sockets are for Table and Floor Lamp Applications Only
Dimmer Control, and Harp Saddle are integral to the socket
26W/32W Dimmer Socket
3.25” 3.75” Ivor y 50/25 1/8” IPS Hickey UL1015 36”
120v 60Hz operation
Have a special requirement? Visit our website at www.satco.com
3 Year Warranty
(Replacement only)
139

Ballasts
Magnetic Ballasts
T8 and T12 Preheat / Trigger Start Ballasts
Primary
Lamp Type
F15T12
F20T12
No of
Lamps
Input
Voltage
1 120 S5268
1 120 S5269
2 120 S5271
Satco
Product
Number Ballast Code
S
MB1X15/120PH/TP 16 Trigger Start Yes
S
MB1X20/120PH/TP 40 Preheat Yes
S5270
S
MB1X20/120PH/TP 40 Preheat No
S
MB2X20/120PH/TP 16 Trigger Start Yes
Pkg
Qty
Starting
Method Potted
ballasts
T9 Circline Rapid Start Ballasts
Primary
Lamp Type
FC8T9
FC12T9
T12 Rapid Start Ballasts
Primary
Lamp Type
F30T12
No of
Lamps
No of
Lamps
Input
Voltage
1 120 S5273
1 120 S5272
Input
Voltage
2 120 need #
277 need #
Listed for F14T8, F14T12, F15T8, F15T12, F20T12 Lamps
Preheat ballasts require the use of a starter
Trigger start ballasts eliminate the need for a starter
Satco
Product
Number Ballast Code
MB1X22/120CIRC 16 Class A NPF
S
MB1X32/120CIRC 16 Class A NPF
S
Listed for FC12T9 and FC16T9 Lamps
Satco
Product
Number Ballast Code
MB2X30/120RS/SRNK 10 Class A HPF
S
MB2X30/277RS/SRNK 10 Class A HPF
S
Listed for F25T12/SS and F30T12 Lamps
Pkg
Qty
Pkg
Qty
Sound
Rating
Sound
Rating
Power
Factor
Power
Factor
140
Customer Service 1-800-43-SATCO

Ballasts
Magnetic Ballasts
T12 Rapid Start Ballasts (cont.)
Primary
Lamp Type
F34T12
F34T12
No of
Lamps
Input
Voltage
1 120 S5274
277 S5275
2 120 S6620
277 S6622
Satco
Product
Number Ballast Code
S
S
Listed for F25T12/SS, F30T12, F34T12, FB34T12, F40T10, F40T12, FB40T12 Lamps
S
S
Listed for F34T12, FB34T12, F40T10, F40T12, FB40T12 Lamps
Pkg
Qty
MB1X40/120RS/SRNK 10 Class A HPF
MB1X40/277RS/SRNK 10 Class A HPF
MB2X40/120RS/SRNK 10 Class A HPF
MB2X40/277RS/SRNK 10 Class A HPF
Sound
Rating
Power
Factor
ballasts
F40T12
1 120 S5276
Listed for F40T12 FULL WATTAGE ONLY - Residential Application
MB1X40/120RES/SRNK 16 Class A NPF
S
T12 Instant Start Slimline Ballasts
Primary
Lamp Type
F48T12
F96T12
No of
Lamps
Input
Voltage
2 120 S5277
277 S5278
1 120 S5279
277 S5280
2 120 S6621
277 S5281
Satco
Product
Number Ballast Code
MB2X48/120IS-SRNK 6 Class B HPF
S
MB2X48/277IS-SRNK 6 Class B HPF
S
Listed for F48T12/SS and F48T12 Lamps
MB1X96/120IS-SRNK 6 Class B HPF
S
MB1X96/277IR-SRNK 6 Class B HPF
S
MB2X96/120IS-SRNK 6 Class B HPF
S
MB2X96/277IS-SRNK 6 Class B HPF
S
Listed for F60T12, F64T12, F72T12, F84T12, F96T12/SS, and F96T12 Lamps
Pkg
Qty
Sound
Rating
Power
Factor
Have a special requirement? Visit our website at www.satco.com
141

Ballasts
Magnetic Ballasts
T12 HO (800mA) Rapid Start Ballasts
Primary
Lamp Type
F96T12/HO
No of
Lamps
Listed for all T12 HO Lamps 18” through 96”
Input
Voltage
1 120 S5282
277 S5283
2 120 S5284
277 S5285
Satco
Product
Number Ballast Code
MB1X96HO/120RS-SRNK 4 Class C HPF
S
MB1X96HO/277RS-SRNK 4 Class C HPF
S
MB2X96HO/120RS-SRNK 4 Class C HPF
S
MB2X96HO/277RS-SRNK 4 Class C HPF
S
Pkg
Qty
Sound
Rating
Power
Factor
T12 HO (800mA) Rapid Start Sign Ballasts
ballasts
Primary
Lamp Type
T12/RS/HO
T12 VHO (1500mA) Rapid Start Ballasts
Primary
Lamp Type
F96T12/VHO
F18T12, F24T12, F30T12, F42T12, F48T12/SS, F48T12, F60T12, F64T12, F72T12, F84T12,
No of
Lamps
No of
Lamps
Input
Voltage
1-2 120 S5290
2-4 120 S5291
4-6 120 S5294
Input
Voltage
1 120V S5264
277V S5265
120V S5266
277V S5267
F96T12/SS, F96T12/CT, F96T12
Satco
Product
Number Ballast Code
MSB-12-0412-TP 1 4ft to 12ft
S
MSB-24-0620-TP 1 6ft to 20ft
S
S5292
S5293
S5295
Listed for all T12 HO Lamps 18” through 120”, as long as they fall within the quantity of lamps
and lamp length requirements listed
Satco
Product
Number Ballast Code
Listed for F48T12/VHO, F60T12/VHO, F72T12/VHO, F96T12/VHO/SS, F96T12/VHO
MSB-24-1224-TP 1 12ft to 24ft
S
MSB-24-2040-TP 1 20ft to 40ft
S
MSB-46-1240-TP 1 12ft to 40ft
S
MSB-46-2448-TP 1 24ft to 48ft
S
MB1X96VHO/120RS-SRNK 4 Class D HPF
S
MB1X96VHO/277RS-SRNK 4 Class D HPF
S
MB2X96VHO/120RS-SRNK 4 Class D HPF
S
MB2X96VHO/277RS-SRNK 4 Class D HPF
S
Pkg
Qty
Pkg
Qty
Total Lamp Length
Sound
Rating
Power
Factor
142