Sartorius YTM15MA Operating Instructions Manual

1000026973
Operating Instructions
YTM15MA
Heating Adjustment Set
Operating Instructions YTM15MA 3
Contents
1 About These Instructions ........ 4
1.1 Scope ......................4
1.2 Other Applicable Documents ...4
1.3 Symbols Used ...............4
1.3.1 Warnings ............ 4
1.3.2 Other Symbols........ 5
2 Safety Instructions .............. 5
2.1 Intended Use ................5
2.2
Personal Protective Equipment
. . 5
2.3 Hot Surfaces ................6
3 Installation..................... 7
3.1 Equipment Supplied ..........7
3.2 Inserting the Battery .........8
4 Operation ...................... 8
4.1 Notes on Calibrating the
Moisture Analyzer ............8
4.2 Transporting and Removing
the Adjustment Disk ..........9
4.3 Need for Calibration/Adjusting
the Heating Module .........11
4.4 Calibrate Heating Module
(MA37 | MA160) ............13
4.5 Calibrate/Adjust Heating
Module (MA37 | MA160) .....17
4.6 Single-Point Temperature
Adjustment (MA35) .........22
5 Cleaning and Maintenance...... 27
5.1 Changing the Battery ........27
5.2 Maintenance ...............27
6 Waste Disposal Policy .......... 27
6.1 General Instructions .........27
6.2 Waste Disposal Policy ........28
7 Sartorius Service...............28
8 Factory Calibration Certificate
(Sample) ...................... 29
4 Operating Instructions YTM15MA
About These Instructions
1 About These Instructions
1.1 Scope
These instructions apply to the following product:
Product Model
Heating Adjustment Set YTM15MA
1.2 Other Applicable Documents
t In addition to these instructions, please observe the
following documents:
Operating Instructions for the Moisture Analyzer (MA35 | MA37 | MA160)
Instructions for the temperature measuring instrument
1.3 Symbols Used
1.3.1 Warnings
CAUTION
Denotes a hazard that may result in moderate or minor injury if it is not avoided.
NOTICE
Denotes a danger that can result in property damage if the risk is not avoided.
Operating Instructions YTM15MA 5
Safety Instructions
1.3.2 Other Symbols
t
Required action: Describes actions which must be carried out.
y
Result: Describes the result of the activities carried out.
[ ] Text inside brackets refers to control and
display items.
Figures on the Operating Display
Depending on the device configuration, the figures on the operating display of the device may differ from those described in these instructions.
2 Safety Instructions
2.1 Intended Use
The product is used for the calibration and adjustment of the heating module of a moisture analyzer (MA35 | MA37 | MA160). Do not use the product in potentially explosive environments.
Any further use beyond this is considered improper and is prohibited. These instructions are part of the product. The product is intended exclusively for use in accordance with these instructions.
2.2 Personal Protective Equipment
Personal protective equipment protects against risks arising from handling the product.
t Wear appropriate personal protective equipment. t Also follow the instructions posted in the work area
pertaining to personal protective equipment.
6 Operating Instructions YTM15MA
Safety Instructions
2.3 Hot Surfaces
During operation, parts of the device can heat up, thereby making their surfaces hot. There is a danger of burns to the body parts that touch these surfaces.
t Avoid contact with hot surfaces. t Before working with the device: Allow the heating
element and device equipment to cool.
t Do not insert the adjustment disk immediately
after drying.
t Always use the removal tool to transport the
adjustment disk or remove it from the moisture analyzer after a measurement.
t Allow the adjustment disk to cool on a clean,
temperature-resistant pad before or after completion of a measurement.
t After cooling, place the adjustment disk back into
the carrying case and store it in a dust-free and protected location.
t Wear personal protective equipment.
Operating Instructions YTM15MA 7
Installation
3 Installation
3.1 Equipment Supplied
1 2 3 4 5 6
Fig. 3-1: Equipment Supplied
Pos. Product Quantity
1 Carrying case 1 2 Temperature measuring instrument 1 3 Adjustment disk 1 4 Battery 1 5 Disk holder (removal tool) 1
8 Operating Instructions YTM15MA
Operation
Pos. Product Quantity
6 Measurement cable (permanently attached to the
adjustment disk)
1
Not illustrated Instructions for the Heating Adjustment Set Not illustrated Instructions for the Temperature Measuring Instrument Not illustrated Factory calibration certificate with serial number
(ref. ID no.)
3.2 Inserting the Battery
t Insert the battery into the temperature measuring instrument (to do this, refer to
the Instructions for the Temperature Measuring Instrument).
4 Operation
4.1 Notes on Calibrating the Moisture Analyzer
When calibrating the moisture analyzer using the heating adjustment set, there is an examination of whether the moisture analyzer is adjusted to the ambient conditions at the place of use. A basic heating adjustment has already been carried out at the factory. This adjustment is valid for many installation sites under laboratory conditions. However, if you have particular ambient conditions, e.g. strong direct sunlight or operation in an exhaust, then an inspection will be necessary.
The adjustment disk has a special coating, which absorbs almost all heat radiation. This ensures that your measurements are reliably adjustable to all operating sites.
If calibration is carried out, then this must be calibrated in the ambient conditions present. E.g.: If the moisture analyzer is operated in a room with exhaust, then the moisture analyzer must also be calibrated at this place of use.
Operating Instructions YTM15MA 9
Operation
The following conditions should be taken into account when calibrating the moisture analyzer:
Carry out calibration in a temperate area. The room temperature should be 20°C.
Carry out calibration in a clean measurement location.
Use a stable and level surface (table).
Drafts, e.g. from open doors/windows, should be avoided. If required: Shield the device.
The frequent movement of persons in front of the device should be avoided (unstable conditions).
Avoid direct sunlight.
Avoid gases or dusts.
Establish a safety distance in the direct vicinity of the device. At least 20 cm on all sides and at least 1 m above the device.
4.2 Transporting and Removing the Adjustment Disk
CAUTION
Danger of burns due to hot adjustment disk!
t Always use the disk holder (removal tool) to
transport the adjustment disk or remove it from the moisture analyzer after calibration.
t Allow the adjustment disk to cool on a clean,
temperature-resistant pad before or after completion of a measurement.
t Only place the adjustment disk back into the
carrying case after cooling.
t Wear personal protective equipment.