– Top Performance
– Intuitive Operation
– Ergonomic Draft Shield
– Automatic Internal Adjustment
– Real-Time Level Support
Product Information
Secura® gives you the security and peace of mind of knowing that you have done everything right. Besides providing
highly accurate weighing results and operating convenience, Secura
complete reliability and regulatory compliance – the safe and secure way.
Real-time guidance prompts for leveling, automatic internal adjustment and 100% traceable, clear documentation
with sample and batch identifiers make your lab work more efficient.
First, the new operating concept of Secura
its APC function – Advanced Pharma Compliance – will relieve you from tedious and time-consuming documentation
and monitoring tasks.
®
will noticeably ease your daily workload during weighing and, second,
®
also features built-in protection systems for
Laboratory Balances
Technical Specifications
AC Adapter
Sartorius AC adaptor module 6971790 with interchangeable
country-specific plug-in AC
adaptors
Primary100 – 240 V~, –10% | +10%,
50 – 60 Hz, 0.2 A
Secondary15 V DC, ± 5%, 530 mA (max.) |
8 Watt (max.): 0 to +40 °C and
15 V DC, ± 5%, 330 mA (max.) |
5 Watt (max.): 0 to +50 °C
Other dataprotection class II, in accordance
with EN | IEC 60950-1 up to
3000 m above sea level;
IP40 as per EN | IEC 60529
Balance
Power supplyonly via Sartorius AC adaptor
module 6971790
Input voltage12.0 ... 18.0 V DC
Power consumption2.0 W (typically)
4.5 W (typically), only for 225D-1x,
125-1x and 324-1x
Ambient Conditions
The specifications apply when the following ambient conditions
are in place:
Environmentfor indoor use only
Ambient temperature*+10 °C to +30 °C
Operational capacityguaranteed between +5 °C and
+45 °C
Storage and shipping–10 °C to +60 °C
Elevationup to 3000 m above sea level
Relative humidity**15% to 80% for temperatures
up to 31 °C; non-condensing,
decreasing linearly to 50% relative
humidity at 40 °C and 20% at 50 °C
Safety of electrical
equipment
in accordance with EN 61010-1/
IEC 61010-1. Safety requirements
for electrical equipment for mea
surement, control, and laboratory
use – Part 1: General requirements
Electromagnetic
compatibility
in accordance with EN 61326-1/
IEC 61326-1. Electrical equipment
for measurement, control, and
laboratory use – EMC requirements
- Part 1: General requirements
Defined immunity to
Suitable for use in industrial areas
interference
Interference emissionClass B (suitable for use in
residential areas and areas that
are connected to a low voltage
network that also supplies
residential buildings).
The device can therefore be
used in both areas.
Balances verified for use in legal metrology comply with the
requirements of Council Directive 2009/23/EC, EN 45501:1992,
and OIML R76:2006.
* For balances verified for use in legal metrology in accordance with
EU requirements, refer to the information on the balance.
** For balances verified for use in legal metrology in accordance with
EU requirements, the legal regulations apply.
Standard Equipment
APC Features– Monitoring of compliance with
the USP minimum sample weight
limits – SQmin
– Password protection of set-up
settings
– Fully automatic temperature-
and time-controlled internal
calibration and adjustment –
isoCAL
– Temporary blockage of data
transfer to a printer or a computer when uncertain weighing
results are detected, such as a
result is below the USP minimum
sample weight limit, the balance
is not level or isoCAL calibration |
adjustment needs to be performed
– Storage of all data of calibration
procedures – Cal Audit Trail
Safety LevelThree configurable levels of security
LevellingIntelligent, optoelectronic leveling
sensor with alarm function
and interactive user guidance for
reliable leveling
CalibrationInternal calibration isoCAL,
External calibration
1)
Selectable weight units
Gram, kilogram, carat, pound,
ounce, troy ounce, Hong Kong tael,
Singapore tael, Taiwan tael, grain,
pennyweights, milligram, parts
per pound, China tael, mommes,
Austrian carat, tola, baht, mesghal
and Newton
Interfacemini USB
– Automatic recognition of
Sartorius printer models YDP30
or YDP40
– Direct data transfer to
Microsoft
®
Windows programs
– Programmable interval for
data output
– Data transfer protocols SBI, xBPI,
table format, text format
DisplayTouch screen with Sartorius
(standard deviation), typical
Linearity deviationmg0.010.1 | 0.1 | 0.20.1 | 0.10.3
Typical starting point of the
operating range
Optimal starting point of the
operating range
2)
2)
Sensitivity drift between
mg425**25**160
mg1.64*8.2**8.2**82
± ppm/K1111
+10 °C and +30 °C
Typical stabilization times86 | 6 | 26 | 62
isoCAL:
– Temperature change
– Time interval
Display result
K
h
1.5
4
1.5
4
1.5
4
1.5
4
s0.2 | 0.40.2 | 0.40.2 | 0.40.2 | 0.2
(depending on the set filter level)
Weighing pan size mm
d 50d 80
(optional d 90)
d 80
(optional d 90)
d 90
Weighing chamber height*** mm218218218218
Net weight, approx. kg8.07.87.87.9
IP protection classIP43IP43IP43IP43
1)
Design 3Design 1Design 2Design 4Design 5
* In combination with glass draft shield YHK01SQP
** In combination with weighing pan, 80 mm, slotted YSP01SQP
*** Upper edge of the weighing pan to the lower edge of the upper draft shield panel
1)
Possible terms for country-specific models:
x = S: Standard balances without country-specific additions
x = SAR: Standard balances with country-specific additions for Argentina
x = SJP: Standard balances with country-specific additions for Japan
x = SKR: Standard balances with country-specific additions for South Korea
2)
According to USP (United States Pharmacopeia) Chapter 41, the optimal operating range is defined from 820d to maximum weighing capacity.