Technical Specifications
AC Adapter
Sartorius AC adaptor
module
Primary100 – 240 V~, –10% | +10%, 50 – 60 Hz, 0.2 A
Secondary15 V DC, ± 5%, 530 mA (max.) |
Other dataprotection class II, in accordance with
6971790 with interchangeable countryspecific plug-in AC adaptors
8 Watt (max.): 0 to +40 °C and 15 V DC,
± 5%, 330 mA (max.) | 5 Watt (max.):
0 to +50 °C
EN | IEC 60950-1 up to 3000
level; IP40 as per EN | IEC 60529
m above sea
Balance
Power supplyonly via Sartorius AC adaptor module
6971790
Input voltage12.0 ... 18.0 V DC
Power consumption2 W (typically)
Laboratory Balances
Ambient Conditions
The specifications apply when the following ambient conditions
are in place:
Environmentfor indoor use only
Ambient
+10 °C to +30 °C
temperature*
Operational capacity guaranteed between +5 °C and +45 °C
Storage and shipping –10 °C to +60 °C
Elevationup to 3,000 m above sea level
Relative humidity**15% to 80% for temperatures up to 31 °C;
non-condensing, decreasing linearly to 50%
relative humidity at 40 °C and 20% at 50 °C
Safety of electrical
equipment
in accordance with EN 61010-1 |
IEC 61010-1. Safety requirements for
electrical equipment for measurement,
control, and laboratory use – Part 1:
General requirements
Electromagnetic
compatibility
in accordance with EN 61326-1 |
IEC 61326-1. Electrical equipment for
measurement, control, and laboratory
use – EMC requirements – Part 1:
General requirements
Defined immunity
Suitable for use in industrial areas
to interference
Interference emission Class B (suitable for use in residential
areas and areas that are connected to a
low voltage network that also supplies
residential buildings). The device can
therefore be used in both areas.
Verified balances in accordance with EU requirements comply
with the requirements of Council Directive 2009/23/EC with
EN 45501:1992 and OIML R76:2006.
* For verified balances in accordance with EU requirements,
refer to the information on the balance.
** For verified balances in accordance with EU requirements,
the legal regulations apply.
Standard Equipment
LevellingGlass level indicator with air bubble for
(standard deviation)
Linearity deviationmg30 303030303003003001,0001,000
Sensitivity drift between
± ppm/K4444488888
+10 °C and +30 °C
Typical stabilization times1.51.51.51.51.51.51.51.511
Weighing pan sizemm
d 180d 180d 180d 180d 180d 180d 180d 180d 180d 180
Net weight, approx.kg3.13.13.13.13.13.13.13.13.13.1
Dimensions, D × W × Hmm
Inch
360 × 216 × 95
14.1 × 8.5 × 3.75
* Upper edge of the weighing pan to the lower edge of the upper draft shield panel
1)
Possible terms for country-specific models:
x = S: Standard balances without country-specific additions
x = SAR: Standard balances with country-specific additions for Argentina
x = SJP: Standard balances with country-specific additions for Japan
x = SKR: Standard balances with country-specific additions for South Korea
Laboratory Balances3
Verified Models with Country-specific Type Approval Certificate
Model
224-1x
2)
124-1x
2)
64-1x
2)
513-1x
2)
313-1x
2)
213-1x
2)
Design111222
Accuracy class
3)
Type
SQP-ASQP-ASQP-ASQP-BSQP-BSQP-B
Max g22012060510310210
Scale interval d mg0.10.10.1111
Verification scale interval e mg111101010
Min mg101010202020
Min
mg100100100200200200
(only for Models ...-1OIN)
Tare equalization range
< 100% from max. weighing capacity
(subtractive)
Typical stabilization time s222111
Weighing pan size mm
d 90d 90d 90d 120d 120d 120
Weighing chamber height*mm209209209209209209
Net weight, approx. kg4.54.54.54.94.94.9
Dimensions, D × W × Hmm
SQP-CSQP-CSQP-CSQP-CSQP-ESQP-ESQP-ESQP-E
Maxg3,1002,1001,1006106,1005,1006,1005,100
Scale interval d mg101010101001001,0001,000
Verification scale interval e mg1001001001001,0001,0001,0001,000
Min g0.50.50.50.5555050
Min
g555550505050
(only for Models ...-1OIN)
Tare equalization range
< 100% from max. weighing capacity
(subtractive)
Typical stabilization times1.51.51.51.51.51.511
Weighing pan size mm
d 180d 180d 180d 180d 180d 180d 180d 180
Net weight, approx. kg3.13.13.13.13.13.13.13.1
Dimensions, D × W × Hmm
Inch
360 × 216 × 95
14.1 × 8.5 × 3.75
2)
* Upper edge of the weighing pan to the lower edge of the upper draft shield panel
2)
Possible terms for country-specific models:
x = CN: CMC Type Approval Certificate for China
x = OJP: Balance with Type Approval Certificate for Japan
x = OBR: Balance with Type Approval Certificate for Brazil
x = ORU: Balance with Type Approval Certificate for Russia
x = OIN: Balance with Type Approval Certificate for India
x = OAU: Balance with Type Approval Certificate for Australia
3)
All models with “...CN”: type “SQP”
Optional Accessories
Printers and Communications
Standard Laboratory Printer
– Printer paper for standard laboratory printer
Data Cable Mini USB | USB AYCC04-D09
Date Cable Mini USB | RS232 9-pinYCC03-D09
Date Cable Mini USB | RS232 25-pinYCC03-D25
General
Battery Pack for Standard Lab BalancesYRB11Z
Draft shield for balances with a readability of 0.01 g | 0.1 g | 1 gYDS01SQP
Draft shield for balances with a readability of 1 mgYDS02SQP
In-use cover for balances with a readability of 0.1 mg and 1 mg6960SE01
In-use cover for balances with a readability of 0.01 g | 0.1 g | 1g6960SE02
Dust cover for balances with a readability of 0.1 mg | 1 mg6960SE03
Density Determination
Density kit for balances with a readability of 0.1 mg | 1 mg YDK03
Density kit for balances with a readability of 0.01 g | 0.1 g | 1gYDK04
YDP40
69Y03287
Calibration Weights
Calibration Weight for lab balance model 224; 313; 213
– Proof Line knob weight 200 g, OIML class E2, with DAkkS certificate
Calibration Weight for lab balance model 124
– Proof Line knob weight 100 g, OIML class E2, with DAkkS certificate
Calibration Weight for lab balance model 64
– Proof Line knob weight 50 g, OIML class E2, with DAkkS certificate
Calibration Weight for lab balance model 513
– Proof Line knob weight 500 g, OIML class E2, with DAkkS certificate
Calibration Weight for lab balance model 3102; 2102
– Proof Line knob weight 2 kg, OIML class F1, with DAkkS certificate
Calibration Weight for lab balance model 1102
– Proof Line knob weight 1 kg, OIML class F1, with DAkkS certificate
Calibration Weight for lab balance model 612
– Proof Line knob weight 500 g, OIML class F1, with DAkkS certificate
Calibration Weight for lab balance model 412
– Proof Line knob weight 200 g, OIML class F1, with DAkkS certificate
Calibration Weight for lab balance model 6101; 5101; 6100; 5100
– Proof Line knob weight 5 kg, OIML class F2, with DAkkS certificate
Calibration Weight for lab balance model 2101
– Proof Line knob weight 2 kg, OIML class F2, with DAkkS certificate
YCW522-AC-02
YCW512-AC-02
YCW452-AC-02
YCW552-AC-02
YCW623-AC-02
YCW613-AC-02
YCW553-AC-02
YCW523-AC-02
YCW654-AC-02
YCW624-AC-02
Laboratory Balances5
Technical Drawings
Models with a readability of 0.1 mg,
in mm
Models with a readability of 1 mg,
in mm
Models with a readability of > 10 mg (exclude 3102),
in mm
180
88
73
119205
359
85
Models with a readability of 10 mg and a capacity of > 3,100 g,
in mm
Specifications subject to change without notice. Copyright Sartorius Lab Instruments GmbH & Co. KG. Printed in the EU on paper bleached without chlorine.