Sartorius PMA.Power PMA35001 Installation Instructions Manual

Page 1
98648-016-91
Installation Instructions
Sartorius PMA.Power Model PMA35001
Electronic Paint-mixing Scales
Page 2
2
1 Display and control unit 2 Display 3 U Zero/tare key 4 I Toggle key
You can configure the PMA35001 menu to enable toggling between grams (g)
and parts per pound (p) 5 Leveling foot 6 K Factor key 7 c Clear key and [REC] key for paint-
mixing applications; depends on the
menu setting 8 L [ENTER] key and [MEM] key for
paint-mixing applications
9 Mounting bracket for display
and control unit 10 Interface (25-contact D-Sub socket) 11 Grounding terminal 12 Power cord with plug 13 Level indicator 14 Cable gland 15 Load plate 16 S ‘Down’ key 17 Power supply and data cable for the
display and control unit 18 R ‘Up’ key
for paint-mixing applications 19 Q On/off (standby) key
1
2
3
4
5 6
7 8
10
19
14
9
13
15
12
16
17
18
11
Page 3
3
Contents
General View of the Equipment . . . . . 2
Intended Use . . . . . . . . . . . . . . . . . . . 3
Warnings and Safety Precautions . . . . 4
Getting Started . . . . . . . . . . . . . . . . . 5
Operation . . . . . . . . . . . . . . . . . . . . . 7
Applications . . . . . . . . . . . . . . . . . . . 8
Calibration/Adjustment . . . . . . . . . . . 11
Operating Menu Configuration . . . . . 12
Troubleshooting Guide . . . . . . . . . . . 17
Care and Maintenance . . . . . . . . . . . . 18
Recycling . . . . . . . . . . . . . . . . . . . . . . 19
Interface Description . . . . . . . . . . . . . 20
Specifications . . . . . . . . . . . . . . . . . . 21
Accessories . . . . . . . . . . . . . . . . . . . . 21
EC Declaration of Conformity . . . . . . 22
Symbols
The following symbols are used in these instructions:
§ indicates required steps $ indicates steps required only under cer-
tain conditions
> describes what happens after you have
performed a particular step
– indicates an item in a list
!indicates a hazard
The PMA35001 scale is specially designed for use in paint-mixing applications. This scale can be operated through the keypad in stand-alone operation or using application software (such as a paint­mixing program from a paint manufac­turer) installed on a connected PC.
If you wish to create your own applica­tion software, Sartorius can supply the required drivers for DOS or Windows operating systems.
Note:
– Make sure to read these operating
instructions carefully before installing and operating your PMA35001 scale.
– As described in the manufacturer’s
declaration, type PMA35001 electronic scales (only with the power cord supplied by Sartorius, type H03 or comparable) may be used in flammable environments if the room is not at risk of inflammation due to excessive dust or fiber deposits. Paint-mixing rooms are generally free of accumulated dust or fibers.
Intended Use
Page 4
4
Warnings and Safety Precautions
The weighing instrument complies with the European Council Directives as well as international regulations and standards for electrical equipment, electromagnetic compatibility, and the stipulated safety requirements. Improper use or handling, however, can result in damage and/or injury. To prevent damage to the equip­ment, read these operating instructions carefully before using your scale. Keep these instructions in a safe place.
– Do not expose the weighing instrument
to aggressive chemical vapors or to extreme temperatures, moisture, shocks, or vibration.
– Exposure to excessive electromagnetic
interference can cause the readout value to change. Once the disturbance has ceased, the instrument can be used again in accor-
dance with its intended purpose. – Do not use electrical equipment out of doors. – The scale may not be operated in hazardous
areas or areas containing potentially explo-
sive agents. If you use electrical equipment
in installations and under ambient condi-
tions subject to stricter safety standards
than those described in the manual, you
must comply with the provisions as speci-
fied in the applicable regulations for
installation in your country. – Make absolutely sure to disconnect the
scale from power (unplug the power cord)
before you connect or disconnect a periph-
eral device (printer or PC) to or from the
interface port. – If you use cables purchased from another
manufacturer, check the pin assignments in
the cable against those specified by Sartorius
before connecting the cable to Sartorius
equipment, and disconnect any wires that
are assigned differently. The operator shall
be solely responsible for any damage or
injuries that occur when using cables not
supplied by Sartorius. Connect only
Sartorius accessories and options, as these
are optimally designed for use with your
PMA scale.
– The power connection must be made in
accordance with the regulations applicable in your country. If you need assistance, contact your Sartorius dealer or the Sartorius Service Center. Any installation work that does not conform to the instructions in this manual will result in forfeiture of all claims under the manufacturer’s warranty.
– If there is any indication that safe operation
of the equipment is no longer warranted; for example, if the AC adapter is defective or shows sign of damage, disconnect the equipment from power and lock it in a safe place to ensure that it cannot be used for the time being.
– Disconnecting the grounding conductor
is prohibited. Make sure the applicable accident prevention regulations are observed by all operating personnel.
– Always make sure the equipment is discon-
nected from AC power before performing any installation, cleaning, maintenance or repair work on the scale or AC adapter. If the equipment housing is opened by anyone other than persons authorized by Sartorius, all claims under the manufac­turer’s warranty are forfeited.
– The casing on all connecting cables, as well
as the casing on wires inside the equipment housing, is made of PVC. Chemicals that corrode this material must be kept away from these cables.
– Do not leave the interface port uncovered.
If the port is not used, or in preparation for shipping, replace the cap to protect the data interface from vapors, moisture and dust or dirt.
– Never use a hammer to close a paint can
while is it still on the load plate, as this will damage the weighing system.
Page 5
5
Getting Started
§ Unpack the scale carefully.
§ After unpacking the equipment, please check
it immediately for any visible damage.
Equipment Supplied
– Scale – Load plate – Adapter cable
Setting up the Scale
Choose a suitable location where your scale will not be exposed to drafts, heat radiation, moisture or vibra­tions. Make sure to read these operating instructions carefully before connecting the scale to power.
!Make sure to observe the safety instructions.
Leveling the Weighing Platform
Purpose:
– To compensate for uneven areas at the place of
installation
– To ensure that the equipment is placed in a perfectly
horizontal position for consistently reproducible weighing results Always level the weighing platform again any time after it has been moved to a different location.
§ Level the weighing platform using the four leveling
feet. Turn the feet until the air bubble is centered in the level indicator.
§ Check to ensure that all leveling feet rest securely
on the work surface. > Each of the leveling feet must support an equal load. > Adjusting the leveling feet:
To raise the weighing platform, extend the leveling
feet (turn counterclockwise). To lower the weighing
platform, retract the leveling feet (turn clockwise).
§ Place the load plate on the scale.
°C
Page 6
6
Connecting the Scale to AC Power
The display and control unit is powered through the scale’s power cord and power PCB.
§ Plug the power cord into a wall outlet (mains).
!Make sure to observe the safety instructions.
Make sure that the voltage rating printed on this unit is identical to your local line voltage. If the voltage specified on the label or the plug design of the power supply do not match the rating or stan­dard you use, please contact your Sartorius office or dealer. Use only original Sartorius power cables. Use of cables from other manufacturers, even if these units have a registered approval rating from a national testing laboratory, requires the consent of a qualified electrician.
$ If there is visible damage to the equipment or power
cord, unplug the equipment and lock it in a secure place to ensure that it cannot be used for the time being.
– Use only extension cords that meet the applicable
standards and have a protective grounding conductor.
– Disconnecting the grounding conductor is
prohibited.
Page 7
7
Operation
Scale Functions
Center an empty paint can on the load plate. Press the U key (zero/tare; 3). The display shows 0.0 g. Pour the first component of your formula into the can and read off the weight when the stability symbol (in this example, “g”) is displayed. Add the other components up to the desired weight (formula). Remove the filled paint can from the load plate.
Never use a hammer to close a paint can while is it still on the load plate, as this will damage the weighing system.
Press the Q key (19) to switch on the scale.
A self-test runs automatically, at the end of which the readout shows 0.0 g.
If a different value is displayed, press U key to tare the scale.
Page 8
8
Applications
Formulation (Calculation by a Factor)
The formulation program makes it easy to adjust your formulas for different final quantities of a paint-mixing recipe (for example, to make 250 ml of a 1-liter recipe). Press the K key (6) to select the desired factor. You can choose from the following:
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 10.0 15.0 20.0 25.0.
Press the R key (18) (up) or
S key (16) (down)
to modify the factor in in 1.0 steps for factors of 5.0 or more,
in 0.1 steps for factors of 1.0 to 5.0,
or in 0.01 steps for factors of up to 1.0.
Note:
A flashing arrow
n on the display indicates that the weight value displayed is not valid
in legal metrology (i.e., not legal for trade).
Example:
During formulation, the weight value is display in g. Let’s suppose you want to weigh 3 kg of a basic formula that is for a total amount of 1 l. With the recalculation mode, you do not need to manually recalculate the individual components. The basic formula for 1 liter is:
250 g first component + 250 g second component + 500 g third component
Total: 1000 g
1. Place the empty paint can on the load plate and tare the scale.
2. Press the K key (6) repeatedly to set the factor to 3 for this example.
Page 9
9
Weighing Using the Recalculation Mode
Let’s suppose that you poured in too much of one color component for a given formula (in this example, a 4-component recipe). This example further assumes that you previously poured in all of the other amounts exactly according to each of the values you entered and saved by pressing the L key [MEM] (9). To correct for the overpour, press the S key (16) to start the recalculation program; C flashes on the display. Use the R key (18; up) or S key (16; down) to correct the value so that it matches the amount called for in the formula. Then press L [MEM] (8) to have the scale calculate the amount to be added for each of the components that were already poured. The display shows the amounts required to correct the formula up to the point at which the overpour occurred. After the correction has been completed, you can continue filling the remaining components.
Note:
You can correct overpours as often as needed. Keep in mind that the total quantity of paint at the conclusion of filling increases each time you correct a component. Press the c key (7) to check how much the total quantity will be. The C stands for “Correction factor.”
A flashing arrow
n on the display indicates that the weight value displayed is not valid in
legal metrology (i.e., not legal for trade).
3. 3.0 next to the weight readout.
4. Slowly pour in the first component until the
display shows 250 g
5. Pour in the second component until 500 g is
displayed.
6. Pour in the last component until 1000 g is
displayed
This concludes the recalculation example. According to the display, exactly 1000 g was poured in, but the paint can actually contains 3 kg by weight in accordance with the factor you selected (3). The procedure is the same for any other conversion factor.
Page 10
10
3. Add first component
+ 50.0 g
2. Press the U key
(zero/tare; 3).
0.0 g
Example (Cumulative Weighing)
1. Center an empty paint can
on the load plate. + 118.0 g
4. Press the L key [MEM] (8)
STO 01
5. Add the second component
+ 110.0 g
6. Press the L key [MEM] (8)
STO 02
7. Add the third component
+ 203.0 g The required amount of this component has been exceeded by 3 g (= overpour).
8. Press the S key (16) to start the recalculation mode. A C (“Correction”) flashes on the display.
9. Press the S key (16) repeat-
edly to correct the value. + 200.0 g
10. Press the L key [MEM]
key (8) COR 01
11. The readout shows the
amount of the first compo­nent to be added, and “C1” is shown in the upper right­hand corner of the display. –1.7 g.
12. Add the first component
until the readout shows
0.0 g
13. Press the L key [MEM] key
COR 02
14. The readout shows the
amount of the second com­ponent to be added, and “C2” is displayed. – 2.0 g
15. Add until 0.0 is displayed.
16. Press the L key [MEM].
The scale returns to the for­mulation program and the “C” is no longer displayed. + 200.0 g.
17. Press the c key (7) [REC]
to view the factor by which the total weight will exceed the original target defined in the recipe. (C = “Correction;” in this example, 1.03). Total weight = original target + correction factor)
18. Add remaining components
+1000.0 g
This concludes the recalculation example.
Page 11
11
Calibration/Adjustment
You can calibrate/adjust the scale by pressing the U key (3).
Calibration weight: 10,000 g; resolution: +
0.016 g.
Always allow approximately 30 minutes for the scale to warm up after connecting it to AC power and before performing calibration/adjustment.
Press the U key (zero/tare) for 2 seconds; “10000” is displayed. Release the key.
Center the calibration weight on the load plate (15). Adjustment is performed automatically. Remove the calibration weight.
Page 12
12
Operating Menu Configuration
Accessing the Operating Menu Example:
Adapting the Scale to Ambient Conditions
§ Hold down the L key [ENTER] for approximately
2 seconds; “SETUP” is displayed.
§ Use the RS keys to select the desired menu item
on this level.
§ Press the L key [Enter] to select the next menu
level.
§ The second menu level is displayed. Use the RS
keys to select the desired menu item on this level.
§ Press the L key [ENTER] to select the next menu
level.
§ The third menu level is displayed. Use the RS keys
to select the desired menu item on this level.
§ Press the L key [ENTER] to select the next menu
level.
§ The fourth menu level is displayed. Use the RS
keys to select the desired menu item on this level.
This concludes the example.
§ Press the L key [ENTER]; o is displayed, indicating
that this item is set.
§ Press c (Clear) repeatedly to exit the menu.
Note:
Contact your local Sartorius office for a detailed list of the menu codes.
Page 13
13
Configuring the Main Menu Settings
§ Hold down the L key [ENTER] for approximately 2 seconds; “SETUP” is displayed.
Level 1
SETUP
Language Setting
Level 1 Level 2
LANGUAGE § Press the R key to select LANGUAGE
§ Press the L key [ENTER]
o GERMAN § Press the RS keys to select a language
ENGLISH § Press the L key [ENTER]; FRENCH o indicates the active setting ITALIAN § Press the c key repeatedly to exit
etc. the menu
Default Unit: Grams or Parts per Pound
The default settings is active when the scale is switched on; defined under “SETUP > SCALE > UNIT”: Level 1 Level 2 Level 3 Level 4
SETUP § Press the L key [ENTER]
SCALE § Press the L key [ENTER]
UNIT § Use the RS keys to select the desired
setting; e.g., “UNIT”
o GRAMS § Press the L key [ENTER]
PT./PD. § Use the RS keys to select the desired
unit; e.g., “GRAMS”
I Activating the Toggle Key
When the toggle key I (4) is active, you can configure it to toggle the weight unit between grams and parts per pound. The unit is toggled when the key is pressed.
Level 1 Level 2 Level 3 Level 4
SETUP § Press the L key [ENTER]
APPLICATION § Use the RS keys to select
“APPLICATION”
§ Press the L key [ENTER]
TOGGLE § Use the RS keys to select “TOGGLE”
OFF § Press the L key [ENTER]
o ON § Use the RS keys to select “ON”
§ Press the L key [ENTER]; o indicates
the active setting
§ Press the c key (Clear) repeatedly
to exit the menu.
Page 14
14
I Configuring the Toggle-key Function
Pressing the toggle key I (4) toggles the scale between the default unit (defined under SETUP > SCALE > UNIT; see page 13) and the unit defined as follows under SETUP > APPLICATION > UNIT.
Level 1 Level 2 Level 3 Level 4
SETUP § Press the L key [ENTER]
APPLICATION § Use the RS keys to select
“APPLICATION”
UNIT § Press the L key [ENTER], press S to
select “UNIT” and press L to confirm.
o PT./PD. § Use the RS keys to select the desired
unit; e.g., “PT./PD.”
GRAMS § Press the L key [ENTER]; o indicates
the active setting.
§ Press the c key (Clear)
Activating the “LOCK” Function
The LOCK function protects the scale from unauthorized use. When this function is active, the scale readout shows weight values only when there is active communication between the scale and a PC. If communication is interrupted, the readout goes blank and the display shows a padlock symbol. Activation of the LOCK function is configured under “EXTRAS.”
Level 1 Level 2 Level 3 Level 4
SETUP § Press the L key [ENTER]
EXTRAS § Use the RS keys to select “EXTRAS”
§ Press the L key [ENTER]
LOCK § Use the RS keys to select “LOCK”
§ Press the L key [ENTER]
OFF § Use the RS keys to select ON and
o ON press L to confirm
§ Press the c key (Clear) repeatedly to exit
the menu.
Page 15
15
Configuring Password Protection
In addition to the LOCK function, you can configure password protection for additional security. With this feature, the LOCK function can be deactivated only by entering the password you configure. The password is numeric and can have up to 6 digits. Use the RS keys to select the digits (0 through 9) for your password. The password is hidden on the readout; only dashes (“------”) are shown. The first dash flashes to prompt input. Press the RS keys as needed to select the desired digit (0 to 9) and then press the L key [ENTER] key. The digit is stored and the second dash flashes on the display. Repeat the input procedure as described for the first digit. To store a space as a character in the password, press the L key [ENTER] while the corresponding dash is flashing. Once all 6 characters have been stored, press the L key [ENTER] to store the password.
Note: Keep a copy of your password in a safe place. The LOCK function can be deactivated only with this password.
Level 1 Level 2 Level 3
INPUT § Use the RS keys to select “INPUT”
PASSWORD § Press the L key [ENTER]
§ Press the L key [ENTER]
PW.NEW § Use the RS keys to select “PW.NEW”
-------- § Enter the desired password and press the
L key [ENTER]
§ Press the c key (Clear) repeatedly to exit
the menu
Changing the Password
To define a new password, the existing password must be entered first in the SETUP menu under “PASSWORD.” “PW.OLD” prompts this input. Once the old password is entered, the “PW.NEW” prompt is shown automatically. Enter the new password or press L at each position to enter spaces. The display shows spaces.
Note: Entering 6 spaces deletes the password, which deactivates the password function.
Level 1 Level 2 Level 3
INPUT § Use the RS keys to select “INPUT”
PASSWORD § Press the L key [ENTER]
PW.OLD § Press the L key [ENTER]
-------- § Enter the existing (old) password PW.NEW > After the old password have been entered
correctly, “PW.NEW” is displayed.
-------- § Enter the desired password and press
the L key [ENTER]
§ Press the c key (Clear) to return
to the menu
Page 16
16
Configuring Text Length (“LONG” or “SHORT”)
You can define the length of the operator guidance texts shown on the display. Level 1 Level 2 Level 3 Level 4
SETUP § Press the L key [ENTER]
EXTRAS § Use the RS keys to select “EXTRAS”
§ Press the L key [ENTER]
TEXTS § Use the RS keys to select “TEXTS”
§ Press the L key [ENTER]
LONG § Use the RS keys to select “SHORT”
o SHORT and press L to confirm
§ Press the c key (Clear) repeatedly
to exit the menu
Resetting the Scale: “RESET”
You can restore the factory settings in the scale. Note: If you have activated the password function, this feature is password-protected.
Level 1 Level 2 Level 3 Level 4
SETUP § Press the L key [ENTER]
RESET § Use the RS keys to select “REST”
§ Press the L key [ENTER]
MENU § Use the RS keys to select “MENU”
§ Press the L key [ENTER]
YES § Use the RS keys to select “YES”
o NO § Press the L key. Factory settings are
restored. “MENU” is displayed
§ Press the c key (Clear) repeatedly
to exit the menu
Code Settings
Select the “CODES” menu item to have menu items identified by numeric codes rather than texts. Level 1 Level 2
LANGUAGE § Press the R key to select LANGUAGE
§ Press the L key [ENTER]
GERMAN § Use the RS keys to select “CODES” etc. § Press the L key [ENTER]; o indicates
o CODES the active setting
§ Press the c key (Clear) repeatedly
to exit the menu
Note:
Contact your local Sartorius office for a detailed list of the menu codes.
Page 17
17
Troubleshooting Guide
Problem Cause Solution
No segments appear – No AC power is available – Check the AC power supply on the display
The weight readout – No load plate on the scale – Position the load plate shows “Low”
The weight readout – Weighing capacity exceeded – Unload the scale shows “High
The weight readout – Unstable environment – Change the place of changes constantly installation
– Too much vibration, or the – Access the menu to select
scale is exposed to a draft the appropriate code for the
ambient conditions
(see “Oper-
ating Menu Configuration”)
The weight readout – The sample is not stable – Tare the scale before weighing is obviously wrong – Scale not tared before
weighing
No weight value is – Communication between scale – Access the menu settings to shown and the and PC has been interrupted, deactivate the LOCK function padlock symbol activating the LOCK function is displayed – Check the connection
Page 18
18
Care and Maintenance
Cleaning
!Never use concentrated acids, alkali solu-
tions or pure alcohol to clean the equip­ment.
!Do not allow liquids to penetrate the
equipment housing.
$ Use a brush or a soft, dry, lint-free cloth
to clean the scale.
Cleaning Stainless Steel Surfaces
Clean all stainless steel parts regularly. Remove the stainless steel load plate and thoroughly clean it separately. Use a damp cloth or sponge to clean stainless steel parts on the scale. You can use any com­mercially available household cleaning agent that is suitable for use on stainless steel. Clean stainless steel surfaces by wiping them down. Then clean the load plate thoroughly, making sure to remove all residues. Afterwards, wipe down stain­less steel parts again using a clean, damp cloth or sponge and allow the equipment to dry. If desired, you can apply oil to the cleaned surfaces as additional protection.
!Solvents are permitted only for cleaning
stainless steel parts.
Corrosive Environment
$ Remove all traces of corrosive substances
from the scale on a regular basis.
Storage and Shipping Conditions
$ The packaging used for shipping your
Sartorius equipment is optimally designed to prevent damage during transport. It is a good idea to save the box and all parts of the packaging for future storage or shipment of the equipment. Only the original packaging provides the best protection for shipment.
$ Allowable storage temperature:
–20 °C to +75 °C (–4 °F to +167 °F)
$ Allowable humidity during storage:
up to 90%
$ Please refer to the information under
“Safety Inspection” below.
Safety Inspection
Safe operation of the scale is no longer ensured in the following cases:
– If there is visible damage to the connect-
ing cable – If the device no longer functions properly – If the equipment has been stored for a
relatively long period under unfavorable
conditions – If the equipment has been subjected to
rough handling during shipment
§ Make sure all warnings and safety
precautions are observed, and notify
your nearest Sartorius Service Center
or the International Technical Support
Unit based in Goettingen, Germany,
if any of the above occurs. Maintenance
and repair work may be performed only
by authorized Sartorius service techni-
cians who have access to the required
maintenance manuals and have received
the necessary training.
!Only authorized service technicians may
open the equipment and perform mainte-
nance work; this ensures that operation
of the equipment is safe and trouble-free
and the warranty remains in effect.
Page 19
19
Recycling
In Germany and many other countries (see www.sartorius.com, Service Down­load area for details), Sartorius or the organization contracted by us takes care of the return and legally compliant disposal of its electrical and electronic equipment on its own. In countries that are not members of the European Eco­nomic Area (EEA) or where no Sartorius subsidiaries or dealerships are located, please contact your local authorities or a commercial disposal operator.
These products may not be placed with household waste or brought to collection centers run by local public disposal oper­ations – not even by small commercial operators.
For disposal in Germany and in the other member nations of the European Economic Area (EEA), please contact our service technicians on location or our Service Center in Goettingen, Germany:
Sartorius Service Center Weender Landstrasse 94–108 37075 Goettingen, Germany
Prior to disposal and/or scrapping of the equipment, any batteries should be removed and disposed of in local collection boxes.
Sartorius will not take back equipment contaminated with hazardous materials (ABC contamination) – either for repair or disposal.
Please refer to the accompanying leaflet/manual or visit our Internet web­site (www.sartorius.com) for comprehen­sive information that includes our service addresses to contact if you plan to send your equipment in for repairs.
If you no longer need the packaging after successful installation of the equipment, you should return it for recycling. The packaging is made from environmen­tally friendly materials and is a valuable source of secondary raw material.
The equipment, including accessories and batteries, does not belong in regular house­hold waste.
Page 20
Interface Description
Pin Assignments
9-contact female connector: Pin 2: (RxD) Receive data Pin 3: (TxD) Transmit data Pin 4: (DTR) Data terminal ready Pin 5: (GND) Ground Pin 6: BPI bridge Pin 8: Clear to send (CTS)
Installing the Adapter Cable
The adapter cable is required for operation of the scale with a PC. If you wish to create your own application software, Sartorius can supply the required drivers for DOS or Windows operating systems.
!Make sure to observe the safety instructions.
§ Remove the protective cover from the interface port.
Keep the protective cover in a safe place.
$ Replace the interface cover when storing or shipping
the scale.
§ Plug in the adapter cable and tighten the retaining
screws
20
Connector on adapter cable
Page 21
21
Specifications
Model PMA35001
Weighing capacity g 35000
Readability g 0.1 Tare range (subtractive) g –35000 Linearity g <±0.2 Stability range
(configured in operating menu) digits 0.25 to 4 Humidity class F Anti-condensation Ambient operating
temperature range °C 0 to +40 (+32 °F to +104 °F) Load plate dimensions mm 350 + 240 Scale housing (W + D + H) mm 350 + 243 + 132.5 Net weight, approximate kg 11.4 Calibration weight kg 10; class E2 or better Power consumption VA Average: 8; maximum: 16 Interface port RS-232
Format 7-bit ASCII, 1 start bit, 1 or 2 stop bitsParity Even, odd, noneTransmission rates: 1,200 to 38,400 bit/sHandshake mode Software or hardware
Accessories
Product Order No.
Dust cover YDC01PMA RS-232 data cable, SBI (2 m) YCC01-0027M2 RS-232 data cable, BPI (2 m) YCC01-0028M2 RS-232 data cable, BPI (20 m) YCC01-0028M20 USB/RS-232 data cable (SBI) (1.8 m) YCO12 USB/RS-232 data cable (BPI) (1.8 m) YCO13
Page 22
22
Page 23
23
Page 24
Printed in Germany on paper that has been bleached without any use of chlorine W_PMA Power 35001 · KT Publication No.: WPM6065-e11113
Sartorius Weighing Technology GmbH Weender Landstrasse 94–108 37075 Goettingen, Germany
Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius.com
Copyright by Sartorius, Goettingen, Germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius. The status of the information, specifications and illustrations in this manual is indicated by the date given below. Sartorius reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.
Status: November 2011, Sartorius Weighing Technology GmbH, Goettingen, Germany
Loading...