General View of the Equipment Model PMA5000 | PMA5000-000U (PMA.Economy)
1 Display and control unit 2 Display/readout 3 Q key (On/Standby) 4 U key: Zero/Tare 5 L key [ENTER] 6 I key (TOGGLE) 7 DC jack for connection to AC power 8 USB connection (optional) 9 Column with channels for power and
USB cables 10 Weighing pan 11 Foot
The following symbols are used in these instructions:
§ Indicates required steps $ Indicates steps required only under
certain conditions
> Describes what happens after you have
performed a particular step
– Indicates an item in a list
!Indicates a hazard
E
con
omy
PMA
.
1 2 3 4 5
6
7 8
9
11
10
3
Contents
2 General View of the Equipment
3 Intended Use
3 Warnings and Safety Precautions
5 Getting Started
7 Operation
8 Calibration/Adjustment
9 Menu Settings
11 Troubleshooting
12 Care and Maintenance
13 Recycling
14 Interface Port
16 Specifications
16 Accessories
16 C Marking
The PMA5000 | PMA5000-000U (PMA.Economy) has been specially designed for use in the paint-mixing sector. Due to its easy operability and upright display, the PMA.Economy is an ideal dose scale.
Note:
– Read the installation and operating
instructions carefully before connecting and putting the PMA5000 | PMA5000-000U into operation.
Warnings and Safety Precautions
This scale meets the guidelines and stan­dards governing electronic equipment, electromagnetic compatibility and the stipulated safety standards. Improper use or handling can result in property damage and/or personal injury. To prevent dam­age to the equipment, read these operat­ing instructions thoroughly before using your scale. Keep these instructions in a safe place.
– If you use electrical equipment in instal-
lations and under ambient conditions requiring higher safety standards, you must comply with the provisions as speci­fied in the applicable regulations for installation in your country.
– Do not expose the scale to extreme
temperatures, aggressive chemical vapors, moisture, shocks or vibrations.
Intended Use
4
– The displayed values can be affected
by up to ±30 digits when subjected to extreme electromagnetic influence. When the negative influence has subsided, the scale will again be fully operational. On request, Sartorius will provide information on the minimum operating specifications (in accordance with the Standards listed in the CE Directive.
– The equipment must be used indoors only.
– The scale may not be operated in
hazardous areas.
– To ensure safety, disconnect the equip-
ment from power before connecting or disconnecting the cables or electronic peripheral devices. The operator shall be responsible for any modifications to Sartorius equipment and for any connections of cables or equip­ment not supplied by Sartorius and must check and, if necessary, correct these modifications and cable connections.
– If you use cables purchased from another
manufacturer, check the pin assignments in the cable against those specified by Sartorius before connecting the cable to Sartorius equipment, and disconnect any wires that are assigned differently. The braided shield in the cable must be made of metal and must provide at least 80% coverage. Both the plug and socket of all connections on the cable ends or in the equipment housing must have foil shielding that is suitable for high fequen­cies in accordance with CE regulations. The operator shall be solely responsible for any damage or injuries that occur when using cables not supplied by Sartorius.
– When connecting the scale to the power
supply, the laws valid in your country must be observed. If you should have any questions, please contact your supplier or Sartorius Customer Service for informa­tion on the legal regulations applicable in your country. The scale must be installed by a certified technician to avoid forfei­ture of all claims under the manufacturer’s warranty.
– If you see any indication that the scale
cannot be operated safely (for example, due to damage), turn it off and lock it in a secure place or otherwise prevent use of the equipment for the time being. Adhere to the accident prevention regulations and inform the operators accordingly.
– Always make sure the equipment is
disconnected from AC power before performing any installation, cleaning, maintenance or repair work on the scale. To avoid forfeiture of all claims under the manufacturer’s warranty, all repair and maintenance work must be performed by authorized Sartorius service technicians.
– All other cables connecting the weighing
equipment and peripheral devices, as well as the wiring inside the devices, are cased in PVC materials. Chemicals that corrode these materials must be kept away from these cables.
5
Getting Started
§ Remove the scale from its packaging.
§ After unpacking the scale, check it immediately
for any visible damage as a result of rough handling during shipment.
Equipment Supplied
– Scale – Weighing pan – AC adapter or power supply – USB cable (only supplied with the PMA5000-000U)
Setting Up the Scale
Choose a suitable place to set up the scale. Avoid exposure to drafts, heat, moisture and vibration. Make sure to read the instructions carefully before connecting the scale to AC power.
!Observe the safety instructions and warnings in this
manual.
§ Place the weighing pan on the scale.
PM
A
.
Economy
E
con
om
y
PM
A
.
°C
6
Connection to AC Power
The equipment is powered through the AC adapter supplied
§ Insert the right-angle plug into the DC jack (7) on
the scale
§ Insert the cable of the right-angle plug into the
cable channel located on the back of column (9)
!Plug the AC adapter into an electrical AC power outlet
!Observe the safety instructions and warnings in this
manual. Check that the voltage rating of the AC adapter matches that of your local line voltage (mains supply). If it does not match your local voltage rating or if the plug design differs from your local standard, contact your Sartorius office or dealer. Use only original Sartorius AC adapters. The use of AC adapters from other manufacturers, even if these units have a registered approval rating from a national testing laboratory, requires the approval of a certified technician.