Sartorius MCA324S-2S00-U, MCA3203SE-S00, MCA324S-2S00-I, MCA4202S-2S00-0, MCA36201S0-S00 Data Sheet

...
Cubis® II
Highlights
• Leading performance. Monolithical weighing system, integrated climate sensors, individual sample holders
• Error-free operation. Individual QApp workflows, motorized auto-leveling*
• Full end-to-end data integrity. 21 CFR Part 11 compliance, integrated audit-trail, state-of-the-art user management
• Oustanding service support. Integrated status center, integrated service functions preventive maintenance on accredited standards
* For all models up to a maximum capacity of 8.2 kg
Product Information
The modular weighing system Cubis® II can be individually configured from different components. The combinability of the display unit, weighing module, draft shield, software packages for various applications and functions and a comprehensive range of accessories allows the individual adaptation of the Cubis® II balance to all weighing tasks. The Cubis® II range of premium laboratory balances with a maximum load between 2.1 g and 70 kg and a readability between 0.1 μg to 1 g provide the ideal model for every application.
Cubis® II Display and Control Units
Type MCA Display Large high end 7” color touch TFT display in 16:9
format with new user interface
Software Factory installed basic set of essential weighing
applications (license free) and Packages with special weighing applications and function extensions (license required)
Operation Activated by touch key, touch-free using IR sensor
(draft shield M) or gesture sensor (optional), learning capability
Type MCE Display State of the art TFT touch screen operation with
brilliant, readable, display but uncomplex, easy to operate user interface
Software Factory installed basic set of essential weighing
applications
Operation Activated by touch key, touch-free using IR sensor
(draft shield M) or gesture sensor (optional), learning capability
Cubis® II
Technical Specifications
Cubis® II Weighing Modules Ultra-Micro Balances 0.0001 mg
2.7S
Scale interval (d) mg 0.0001 Maximum capacity (Max) g 2.1
Repeatability at 5 % load
Standard deviation of the load values, tolerance mg 0.0002 Standard deviation of the load values, typical value mg 0.00015
Repeatability near Max
Standard deviation of the load values, tolerance mg 0.00025 Standard deviation of the load values, typical value mg 0.00018
Linearity Deviation
Tolerance mg 0.0009 Typical value mg 0.0007
Deviation at eccentric loading, positions according to OIML R76
Test weight g 1 Tolerance mg 0.0007 Typical value mg 0.0005 Sensitivity drift between +10 °C and +30 °C ppm/K 1
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EU I Verification scale interval (e) according to Directive 2014/31/EU mg 1 Minimum load (Min) according to Directive 2014/31/EU mg 0.01
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
Optimum minimum weight mg 0.082 Typical minimum weight mg 0.3 Typical stabilization time s 7 Typical measurement time s 10
Recommended calibration weight
External test load g 2 Accuracy class, acc. to OIML R111-1 E2
Dimensions
MCE/MCA Weighing module (L × W × H)* mm 340 x 139 x 129 MCE Electronics module (L × W × H) mm 315 x 240 x 61 MCA Electronics module (L x W x H) mm 355 x 240 x 61 Weighing pan size mm Ø 20 Filter weighing pan mm Ø 50 Weight, approx.* kg 6.4/7.1
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II Weighing Modules Micro Balances 0.001 mg
10.6S 6.6S 3.6P
Scale interval (d) mg 0.001 0.001 0.001 | 0.002 | 0.005 Maximum capacity (Max) g 10.1 6.1 1.1 | 2.1 | 3.1
Repeatability at 5 % load
Standard deviation of the load values, tolerance mg 0.001 0.001 0.003 Standard deviation of the load values, typical value mg 0.0005 0.0005 0.0005
Repeatability near Max
Standard deviation of the load values, tolerance mg 0.001 0.001 0.005 Standard deviation of the load values, typical value mg 0.0006 0.0006 0.0006
Linearity Deviation
Tolerance mg 0.004 0.004 0.004 Typical value mg 0.003 0.003 0.003
Deviation at eccentric loading, positions according to OIML R76
Test weight g 5 2 1 Tolerance mg 0.004 0.004 0.005 Typical value mg 0.003 0.003 0.003 Sensitivity drift between +10 °C and +30 °C ppm/K 1 1 1
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EU I I I Verification scale interval (e) according to Directive 2014/31/EU mg 1 1 1 Minimum load (Min) according to Directive 2014/31/EU mg 0.1 0.1 0.1
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
Optimum minimum weight mg 0.82 0.82 0.82 Typical minimum weight mg 0.82 0.82 0.82 Typical stabilization time s 5 5 5 Typical measurement time s 8 8 8
Recommended calibration weight
External test load g 10 5 3 Accuracy class, acc. to OIML R111-1 E2 E2 E2
Dimensions
MCE/MCA Weighing module (L × W × H)* mm 340 x 139 x 129 340 x 139 x 129 340 x 139 x 129 MCE Electronics module (L × W × H) mm 315 x 240 x 61 315 x 240 x 61 315 x 240 x 61 MCA Electronics module (L x W x H) mm 355 x 260 x 61 355 x 260 x 61 355 x 260 x 61 Weighing pan size mm Ø 30 Ø 30 Ø 30 Filter weighing pan mm Ø 50 Ø 50 Ø 50 Weight, approx.* kg 6.4/7.1 6.4/7.1 6.4/7.1
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II 3
Cubis® II Weighing Modules Semi-Micro Balances 0.01 mg
225S 225P 125S 125P
Scale interval (d) mg 0.01 0.01 | 0.02 | 0.05 0.01 0.01 | 0.1 Maximum capacity (Max) g 220 60 | 120 | 220 120 60 | 120
Repeatability at 5 % load
Standard deviation of the load values, tolerance mg 0.015 0.015 0.015 0.015 Standard deviation of the load values, typical value mg 0.01 0.01 0.01 0.01
Repeatability near Max
Standard deviation of the load values, tolerance mg 0.025 0.04 0.025 0.06 Standard deviation of the load values, typical value mg 0.02 0.02 0.02 0.02
Linearity Deviation
Tolerance mg 0.1 0.15 0.1 0.15 Typical value mg 0.065 0.1 0.065 0.1
Deviation when load is off-center, positions according to OIML R76
Test weight g 100 100 50 50 Tolerance mg 0.15 0.2 0.15 0.2 Typical value mg 0.1 0.1 0.1 0.1 Sensitivity drift between +10 °C and +30 °C ppm/K 1 1 1 1
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EU I I I I Verification scale interval (e) according to Directive 2014/31/EU mg 1 1 1 1 Minimum load (Min) according to Directive 2014/31/EU mg 1 1 1 1
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
Optimum minimum weight mg 8.2 8.2 8.2 8.2 Typical minimum weight mg 13 13 13 13 Typical stabilization time s 2 2 2 2 Typical measurement time s 6 6 6 6
Recommended calibration weight
External test load g 200 200 100 100 Accuracy class, acc. to OIML R111-1 E2 E2 E2 E2
Dimensions
MCE/MCA Weighing module (L × W × H)* mm 404 x 240 x 373 MCE Electronics module (L × W × H) mm 315 x 240 x 61 MCA Electronics module (L x W x H) mm 355 x 240 x 61 Weighing pan size mm 85 x 85 Weight, approx.* kg 10.2/11.7
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II Weighing Modules Analytical Balances 0.1 mg
524S 524P 324S 324P 224S 124S
Scale interval (d) mg 0.1 0.1 | 0.2 | 0.5 0.1 0.1 | 0.2 | 0.5 0.1 0.1 Maximum capacity (Max) g 520 120 | 240 | 520 320 80 | 160 | 320 220 120
Repeatability at 5 % load
Standard deviation of the load values, tolerance mg 0.08 0.08 0.08 0.08 0.07 0.1 Standard deviation of the load values, typical
value
mg 0.04 0.04 0.04 0.04 0.05 0.05
Repeatability near Max
Standard deviation of the load values, tolerance mg 0.1 0.15 0.1 0.1 0.07 0.1 Standard deviation of the load values, typical
value
mg 0.05 0.05 0.05 0.05 0.05 0.05
Linearity Deviation
Tolerance mg 0.4 0.5 0.3 0.5 0.2 0.2 Typical value mg 0.2 0.2 0.2 0.2 0.13 0.13
Deviation when load is off-center, positions according to OIML R76
Test weight g 200 200 200 200 100 50 Tolerance mg 0.3 0.4 0.3 0.4 0.2 0.2 Typical value mg 0.2 0.2 0.2 0.2 0.12 0.12 Sensitivity drift between +10 °C and +30 °C ppm/K 1 1 1 1 1 1
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EU
Verification scale interval (e) according to Directive 2014/31/EU
Minimum load (Min) according to Directive 2014/31/EU
mg 1 1 1 1 1 1
mg 10 10 10 10 10 10
I I I I I I
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
Optimum minimum weight mg 82 82 82 82 82 82 Typical minimum weight mg 82 82 82 82 100 100 Typical stabilization time s 1 1 1 1 1 1 Typical measurement time s 3 3 3 3 3 3
Recommended calibration weight
External test load g 500 500 300 300 200 100 Accuracy class, acc. to OIML R111-1 E2 E2 E2 E2 E2 E2
Dimensions
Weighing module (L × W × H)* mm 425 x 240 x 373 Weighing pan size mm 85 x 85 Weight, approx.* kg 8.2/10.0
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II 5
Cubis® II Weighing Modules Precision Balances
5203S 5203P 3203S 2203S 2203P 1203S
Scale interval (d) mg 1 1 | 2 | 5 1 1 1 | 10 1 Maximum capacity (Max) g 5200
1200 | 2400 | 5200
3200 2200 1010 | 2200 1200
Repeatability at 5 % load
Standard deviation of the load values, tolerance
Standard deviation of the load values, typical value
mg 1 1 1 0.7 0.7 0.7
mg 0.6 0.6 0.6 0.5 0.5 0.5
Repeatability near Max
Standard deviation of the load values, tolerance
Standard deviation of the load values, typical value
mg 1 1 1 1 1 0.7
mg 0.6 0.6 0.6 0.6 0.6 0.6
Linearity Deviation
Tolerance mg 5 5 5 3 5 2 Typical value mg 2 3 2 2 3 1
Deviation when load is off-center, positions according to OIML R76
Test weight g 2000 2000 1000 1000 1000 500 Tolerance mg 2 2 2 2 3 2 Typical value mg 1 1 1 1 2 1 Sensitivity drift between +10 °C and +30 °C ppm/K 1 1 1 1 1 1.5
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EU
Verification scale interval (e) according to Directive 2014/31/EU
Minimum load (Min) according to Directive 2014/31/EU
mg 10 10 10 10 10 10
mg 100 100 100 100 100 100
I I I I I I
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
Optimum minimum weight mg 820 820 820 820 820 820 Typical minimum weight mg 1200 1200 1200 1000 1000 1000 Typical stabilization time s 1 1 1 1 1 1 Typical measurement time s 2 2 2 1.5 1.5 1.5
Recommended calibration weight
External test load g 5000 5000 3000 2000 1000 1000 Accuracy class, acc. to OIML R111-1 E2 E2 E2 E2 E2 E2
Dimensions
Weighing module (L × W × H)* mm 425 x 240 x 122/284/373 Weighing pan size mm 140 x 140 Weight, approx.* kg 5.9/7.5/9.4/10.2
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II Weighing Modules Precision Balances
623S 623P 323S 14202S 14202P
Scale interval (d) mg 1 1 / 2 / 5 1 10 10 | 20 | 50 Maximum capacity (Max) g 620 150 | 300 | 620 320 14200 3500 | 7000 | 14200
Repeatability at 5 % load
Standard deviation of the load values, tolerance
Standard deviation of the load values, typical value
mg 0.7 1 0.7 10 10
mg 0.4 0.4 0.4 5 5
Repeatability near Max
Standard deviation of the load values, tolerance
Standard deviation of the load values, typical value
mg 0.7 1 0.7 10 10
mg 0.5 0.5 0.5 5 5
Linearity Deviation
Tolerance mg 2 5 2 30 50 Typical value mg 0.6 1.5 0.6 10 20
Deviation when load is off-center, positions according to OIML R76
Test weight g 200 200 200 5000 5000 Tolerance mg 2 4 2 20 40 Typical value mg 1 3 1 10 10 Sensitivity drift between +10 °C and +30 °C ppm/K 2 2 2 1.5 1.5
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EU
Verification scale interval (e) according to Directive 2014/31/EU
Minimum load (Min) according to Directive 2014/31/EU
mg 10 10 10 100 100
mg 20 20 20 1000 1000
II II II II II
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
Optimum minimum weight mg 820 820 820 8200 8200 Typical minimum weight mg 820 820 820 8200 8200 Typical stabilization time s 0.8 0.8 0.8 0.8 0.8 Typical measurement time s 1 1 1 1.5 1.5
Recommended calibration weight
External test load g 500 500 200 14000 14000 Accuracy class, acc. to OIML R111-1 E2 E2 E2 E2 E2
Dimensions
Weighing module (L × W × H)* mm 425 x 240 x 122/284/373 425 x 240 x 95 Weighing pan size mm 140 x 140 206 x 206 Weight, approx.* kg 5.9/7.5/9.4/10.2 5.4
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II 7
Cubis® II Weighing Modules Precision Balances
10202S 8202S 6202S 6202P 5202S 4202S 2202S
Scale interval (d) mg 10 10 10 10 | 20 | 50 10 10 10
Maximum capacity (Max) g 10200 8200 6200
1500 | 3000 |6200
5200 4200 2200
Repeatability at 5 % load
Standard deviation of the load values, tolerance
Standard deviation of the load values, typical value
mg 7 7 7 7 6 7 7
mg 5 4 4 4 2 4 4
Repeatability near Max
Standard deviation of the load values, tolerance
Standard deviation of the load values, typical value
mg 7 7 7 40 6 7 7
mg 5 4 4 15 2 4 4
Linearity Deviation
Tolerance mg 20 20 20 50 10 20 20 Typical value mg 6 6 6 20 5 6 6
Deviation when load is off-center, positions according to OIML R76
Test weight g 5000 5000 2000 2000 2000 2000 1000 Tolerance mg 20 20 20 50 10 30 20 Typical value mg 10 10 10 30 5 10 10 Sensitivity drift between +10 °C and +30 °C ppm/K 1.5 2 2 2 2 2 2
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EU
Verification scale interval (e) according to Directive 2014/31/EU
Minimum load (Min) according to Directive 2014/31/EU
mg 100 100 100 100 100 100 100
mg 1000 500 500 500 1000 500 500
II II II II I II II
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
Optimum minimum weight mg 8200 8200 8200 8200 8200 8200 8200 Typical minimum weight mg 8200 8200 8200 8200 8200 8200 8200 Typical stabilization time s 0.8 1 1 1 0.8 1 0.8 Typical measurement time s 1.5 1.5 1.5 1.5 1 1 1.5
Recommended calibration weight
External test load g 10000 7000 5000 5000 5000 3000 1500 Accuracy class, acc. to OIML R111-1 E2 E2 E2 E2 E2 E2 E2
Dimensions
Weighing module (L × W × H)* mm 425 x 240 x 95
425 x 240 x 122/284/373
425 x 240 x 95
Weighing pan size mm 206 x 206 140 x 140 206 x 206
Weight, approx.* kg 5.4 5.9/ 7.5/9.4/10.2 5.4
* depending upon weighing pan size, filter weighing pan and draft shield