• Full end-to-end data integrity. 21 CFR Part 11 compliance,
integrated audit-trail, state-of-the-art user management
• Oustanding service support. Integrated status center, integrated
service functions preventive maintenance on accredited
standards
* For all models up to a maximum capacity of 8.2 kg
Product Information
The modular weighing system Cubis® II can be individually configured from different components. The combinability
of the display unit, weighing module, draft shield, software packages for various applications and functions and a
comprehensive range of accessories allows the individual adaptation of the Cubis® II balance to all weighing tasks.
The Cubis® II range of premium laboratory balances with a maximum load between 2.1 g and 70 kg and a readability
between 0.1 μg to 1 g provide the ideal model for every application.
Cubis® II Display and Control Units
TypeMCA
DisplayLarge high end 7” color touch TFT display in 16:9
format with new user interface
SoftwareFactory installed basic set of essential weighing
applications (license free) and Packages with
special weighing applications and function
extensions (license required)
Operation Activated by touch key, touch-free using IR sensor
(draft shield M) or gesture sensor (optional),
learning capability
TypeMCE
DisplayState of the art TFT touch screen operation with
brilliant, readable, display but uncomplex, easy to
operate user interface
SoftwareFactory installed basic set of essential weighing
applications
Operation Activated by touch key, touch-free using IR sensor
(draft shield M) or gesture sensor (optional),
learning capability
Cubis® II
Technical Specifications
Cubis® II Weighing Modules
Ultra-Micro Balances 0.0001 mg
2.7S
Scale interval (d)mg0.0001
Maximum capacity (Max)g2.1
Repeatability at 5 % load
Standard deviation of the load values, tolerancemg0.0002
Standard deviation of the load values, typical valuemg0.00015
Repeatability near Max
Standard deviation of the load values, tolerancemg0.00025
Standard deviation of the load values, typical valuemg0.00018
Linearity Deviation
Tolerancemg0.0009
Typical valuemg0.0007
Deviation at eccentric loading, positions according to OIML R76
Test weightg1
Tolerancemg0.0007
Typical valuemg0.0005
Sensitivity drift between +10 °C and +30 °Cppm/K1
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EUI
Verification scale interval (e) according to Directive 2014/31/EUmg1
Minimum load (Min) according to Directive 2014/31/EUmg0.01
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
External test loadg2
Accuracy class, acc. to OIML R111-1E2
Dimensions
MCE/MCA Weighing module (L × W × H)*mm340 x 139 x 129
MCE Electronics module (L × W × H)mm315 x 240 x 61
MCA Electronics module (L x W x H)mm355 x 240 x 61
Weighing pan sizemmØ 20
Filter weighing panmmØ 50
Weight, approx.*kg6.4/7.1
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II Weighing Modules
Micro Balances 0.001 mg
Deviation at eccentric loading, positions according to OIML R76
Test weightg521
Tolerancemg0.0040.0040.005
Typical valuemg0.0030.0030.003
Sensitivity drift between +10 °C and +30 °Cppm/K 111
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EUIII
Verification scale interval (e) according to Directive 2014/31/EU mg111
Minimum load (Min) according to Directive 2014/31/EUmg0.10.10.1
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
External test loadg1053
Accuracy class, acc. to OIML R111-1E2E2E2
Dimensions
MCE/MCA Weighing module (L × W × H)*mm340 x 139 x 129340 x 139 x 129340 x 139 x 129
MCE Electronics module (L × W × H)mm315 x 240 x 61315 x 240 x 61315 x 240 x 61
MCA Electronics module (L x W x H)mm355 x 260 x 61355 x 260 x 61355 x 260 x 61
Weighing pan sizemmØ 30Ø 30Ø 30
Filter weighing panmmØ 50Ø 50Ø 50
Weight, approx.*kg6.4/7.16.4/7.16.4/7.1
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II3
Cubis® II Weighing Modules
Semi-Micro Balances 0.01 mg
Deviation when load is off-center, positions according to OIML R76
Test weightg1001005050
Tolerancemg0.150.20.150.2
Typical valuemg0.10.10.10.1
Sensitivity drift between +10 °C and +30 °Cppm/K 1111
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EUIIII
Verification scale interval (e) according to Directive 2014/31/EU mg1111
Minimum load (Min) according to Directive 2014/31/EUmg1111
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
External test loadg200200100100
Accuracy class, acc. to OIML R111-1E2E2E2E2
Dimensions
MCE/MCA Weighing module (L × W × H)*mm404 x 240 x 373
MCE Electronics module (L × W × H)mm315 x 240 x 61
MCA Electronics module (L x W x H)mm355 x 240 x 61
Weighing pan sizemm85 x 85
Weight, approx.*kg10.2/11.7
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II Weighing Modules
Analytical Balances 0.1 mg
Deviation when load is off-center, positions according to OIML R76
Test weightg20020020020010050
Tolerancemg0.30.40.30.40.20.2
Typical valuemg0.20.20.20.20.120.12
Sensitivity drift between +10 °C and +30 °Cppm/K 111111
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive
2014/31/EU
Verification scale interval (e) according to
Directive 2014/31/EU
Minimum load (Min) according to Directive
2014/31/EU
mg111111
mg101010101010
IIIIII
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
External test loadg5005002001400014000
Accuracy class, acc. to OIML R111-1E2E2E2E2E2
Dimensions
Weighing module (L × W × H)*mm425 x 240 x 122/284/373425 x 240 x 95
Weighing pan sizemm140 x 140 206 x 206
Weight, approx.*kg5.9/7.5/9.4/10.25.4
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II7
Cubis® II Weighing Modules
Precision Balances
10202S 8202S6202S6202P5202S4202S2202S
Scale interval (d)mg10101010 | 20 | 50101010
Maximum capacity (Max)g1020082006200
1500 | 3000
|6200
520042002200
Repeatability at 5 % load
Standard deviation of the load values,
tolerance
Standard deviation of the load values,
typical value
mg7777677
mg5444244
Repeatability near Max
Standard deviation of the load values,
tolerance
Standard deviation of the load values,
typical value
mg77740677
mg54415244
Linearity Deviation
Tolerancemg20202050102020
Typical valuemg66620566
Deviation when load is off-center, positions according to OIML R76
Test weightg5000500020002000200020001000
Tolerancemg20202050103020
Typical valuemg1010103051010
Sensitivity drift between +10 °C and +30 °C ppm/K 1.5222222
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive
2014/31/EU
Verification scale interval (e) according to
Directive 2014/31/EU
Minimum load (Min) according to Directive
2014/31/EU
mg100100100100100100100
mg10005005005001000500500
IIIIIIIIIIIII
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
External test loadg10000700050005000500030001500
Accuracy class, acc. to OIML R111-1E2E2E2E2E2E2E2
Dimensions
Weighing module (L × W × H)*mm425 x 240 x 95
425 x 240 x
122/284/373
425 x 240 x 95
Weighing pan sizemm206 x 206140 x 140206 x 206
Weight, approx.*kg5.45.9/ 7.5/9.4/10.2 5.4
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II Weighing Modules
Precision Balances
1202S12201S8201S5201S
Scale interval (d)mg10100100100
Maximum capacity (Max)g12001220082005200
Repeatability at 5 % load
Standard deviation of the load values, tolerancemg7505050
Standard deviation of the load values, typical valuemg4202020
Repeatability near Max
Standard deviation of the load values, tolerancemg7505050
Standard deviation of the load values, typical valuemg4202020
Linearity Deviation
Tolerancemg20100100100
Typical valuemg6303020
Deviation when load is off-center, positions according to OIML R76
Test weightg500500020002000
Tolerancemg20200200200
Typical valuemg10100100100
Sensitivity drift between +10 °C and +30 °Cppm/K 2444
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EUIIIIIIII
Verification scale interval (e) according to Directive 2014/31/EUmg100100010001000
Minimum load (Min) according to Directive 2014/31/EUmg500500050005000
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
Deviation when load is off-center, positions according to OIML R76
Test weightg500050002000010000
Tolerancemg30030010001000
Typical valuemg200200600500
Sensitivity drift between +10 °C and +30 °Cppm/K 2233
Tare maximum capacity: Less than 100 % of maximum capacity
Accuracy class according to Directive 2014/31/EUIIIIIIII
Verification scale interval (e) according to Directive 2014/31/EUmg10001000100001000
Minimum load (Min) according to Directive 2014/31/EUmg500050005000050000
Minimum weight according to USP (United States Pharmacopeia), Chap. 41
External test loadg20000100007000030000
Accuracy class, acc. to OIML R111-1F1F1F1F1
Dimensions
Weighing module (L × W × H)*mm412 x 400 x 126/159
Weighing pan sizemm400 x 300/Ø 233
Weight, approx.*kg15.8/17.1
* depending upon weighing pan size, filter weighing pan and draft shield
Cubis® II11
Accessories
Cubis® II Power Supply Unit
Only by Sartorius AC Adapter YEPS03-15V0UnitValue
Primary
AC voltageV
FrequencyHz
Current consumption, maximumA1.0
Secondary
DC voltage at 2 A output currentV14.25–15.75
Power, maximumW30
Short circuit protection: Electronic
Protection class according to IEC 62368-1I
Pollution level according to IEC 61010-12
Overvoltage category according to IEC 606641-1II
Installation site according to IEC 62368-1, maximum altitude above sea levelm5000
Temperature
In operation °C0 – +40
During storage and transport°C-20 – +80
Connector for mains connection according to IEC 60320-1 / C14: 3-pin
100–240 (±10%)
50–60 (±5%)
Power supply cable
Power supply cable according to IEC 60320-1 / C14: Country-specific, 3-pin, two-sided plug
Other data: See label on AC adapter
Safety of Electrical Equipment
According to EN 61010-1 / IEC 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use
– Part 1: General Requirements
Electromagnetic Compatibility
Interference resistance
Suitable for use in industrial areas
Transient emissions
Class B
Suitable for use in residential areas and areas that are connected to a low voltage network that also supplies residential buildings.
Materials
Housing: Die-cast aluminum, plastic PBT, Optiwhite float glass and stainless steel 1.4401/1.4404, PA handles, aluminum trim
Control unit: Die-cast aluminum, painted, float glass and plastic PBT, PP
Integrated Clock
Maximum deviation per month (RTC): 30s
Backup Battery
Lithium battery: type CR2032
Service life at room temperature, minimum: 10 Years
Alibi Memory Value
Maximum number of data records: 150,000
Interfaces
Specifications for the COM-RS232 Interface
Type of interface: Serial interface
Interface operation: Full duplex
Level: RS232
Connection: D-sub connector, 9-pin
Pin assignment:Pin 1: Not assigned
Pin 2: Data output (TxD)
Pin 3: Data input (RxD)
1
6
Specifications for the USB-A Interface
Communication: USB host (master)
Connectable devices: Sartorius printers, USB sticks with software update
Specifications for the USB-B Interface
Communication: USB device (slave)
Type of interface: Virtual serial interface (virtual COM-port, VCP) and “PC direct” communication
5
9
Pin 4: Not assigned
Pin 5: Internal ground
Pin 6: Not assigned
Pin 7: Clear to Send (CTS)
Pin 8: Request to Send (RTS)
Pin 9: Not assigned
Cubis® II13
Ambient Conditions
UnitValue
Installation Site
AC voltage
Frequency
V
Hz
100–240 (±10%)
50–60 (±5%)
Current consumption, maximumA1.0
Secondary
Standard laboratory rooms
Installation site according to IEC 60259-1, maximum altitude above sea levelm3000
For indoor use only
Temperature
In operation°C+5 – +40
In operation for conformity-assessed devices: See information on the device’s ID plate
During storage and transport°C-20 – +60
Relative humidity
At temperatures of up to 31 °C%80
Then linear decrease from 80 % at 31 °C to 50 % at 40 °C
No heat from heating systems or direct sunlight
No drafts from open windows, AC systems, or doors
No vibrations
No “heavy traffic” areas (personnel)
No electromagnetic fields
No dry air
Meteorological Data
CodeItem
SØØStandard version non-verified, all units
S01Standard version non-verified, metric units only
CCNBalance with Type Approval Certificate for China
CEUVerified balance with EC Type Approval Certificate (for EU except France)
CFRVerified balance with EC Type Approval Certificate for France only
OBRBalance with Type Approval Certificate for Brazil
OINBalance with Type Approval Certificate for India
OJPBalance with Type Approval Certificate for Japan
ORUBalance with Type Approval Certificate for Russia
Draft Shields
CodeItem
0Flat, stainless steel weight pan with no draft shield for weighing modules.
AAutomatic, glass motorized draft shield with learning capability for user-friendly operation and easy customization to
the changing requirements of different applications.
EManual glass draft shield for precision balances.
FManual stainless steel draft shield for weighing filters with diameters of up to 50 mm (75 mm and 90 mm pans
optional).
IIdentical to the A draft shield, but also includes an integrated ionizer to eliminate interfering electrostatic charges on
samples and sample containers.
MAutomatic, motorized, round 100% glass draft shield with learning capability for ultra-microbalance and microbalances.
RFlat, stainless steel weighing pan draft shield (removable, with no glass components) for all precision balances
UManual glass analytical draft shield chamber, with smooth-action doors that open wide and provide unimpeded access
to the weighing chamber without interfering braces.
Thermal transfer | thermal printer for GLMP printouts on continuous paper and labels1YDP30
Standard paper and ink ribbon, set, 90 m, for YDP30169Y03285
Self-adhesive paper and ink ribbon, 90 m, for YDP30169Y03286
Standard thermal paper, 24 m roll, for YDP30 | YDP40569Y03287
Self-adhesive thermal paper, 13 m roll, for YDP30569Y03288
Self-adhesive labels for YDP30
58 mm × 100 mm35069Y03094
58 mm × 76 mm50069Y03093
58 mm × 30 mm100069Y03092
Display cable, 3 m, for separate installation of display and weighing units, installation by Sartorius
1On request
Service or at the factory
RS232C connection cable, 9-pin, 3 m, for connection to a PC with 9-pin COM interface1On request
Sartorius Wedge, software for data communication between the PC and balance1YSW02
Cubis® II15
Accessories (continued)
Displays and Input/Output ElementsQuantityOrder number
MCE Display and control unit with color TFT display, touch screen, and keys169ME0212
MCA Display and control unit with high-contrast display, touch screen, and keys169MA0218
Motion sensor for triggering a maximum of 4 functions via gesture control, selection via menu1YHS02MS
Display stand for weigh cells with scale interval of 100 mg | 1 g and weighing capacity > 20 kg for
raising the operating unit
Display stand for weigh cells with scale interval of 10 mg | 100 mg for raising the operating unit1YDH03MS
Hardware for Pipette Calibration (Semi-Micro and Analytical balances)QuantityOrder number
Pipette calibration kit (hardware). Consists of moisture trap and all required adapters1YCP04MS
Density Determination KitsQuantityOrder number
Density determination kit for solids and liquids for 0.1 and 0.01 mg weighing modules1YDK03MS
Density determination kit for solids and liquids for 1 mg weighing modules1YDK04MS
Filter Pans, Ionizer and Weighing ScoopsQuantityOrder number
Grid pan for model with a scale interval of 10 mg or 100 mg for weighing in laboratory hoods,
safety barries and workbenches, reduced wind attack surface of the weighing pan, replaces standard
pan
Anti-static weighing pan, 100 mm diameter, for weighing module for semi-mnicrobalance and
analytical balances with 0.1 mg or 0.01 mg scale interval
Filter weighing pan made of Titanium, diameter 52 mm, for ultra-micro and micro-balances only
together with F draft shield
Filter weighing pan made of Titanium, diameter 75 mm, for ultra-micro balance or micro balance
models only together with F draft shield
Filter weighing pan made of Titanium, diameter 90 mm, for ultra-micro balance or micro balance
models only together with F draft shield
Ionization blower for electrostatically charged samples1YIB01-ODR
Ionizer with u-shaped electrode for 230 V1YIB02-230V
Ionizer with u-shaped electrode for 115 V1YIB02-115V
Stat-Pen ionization pen for discharging electrostatically charged samples1YSTP01
Aluminum weighing scoop, 4.5 mg for ultramicrobalance and microbalance models2506565-250
Aluminum weighing scoop, 52 mg for ultramicrobalance and microbalance models506566-50
Weighing scoop made from chrome-nickel steel, L 90 mm x W 32 mm x H 8 mm1641214
1YDH04MS
1YWP07MS
1YWP04MS
1YSH34
1YSH35
1YSH36
Other AccessoriesQuantityOrder number
Below-balance weighing hook for precision balances with scale interval of 100 mg | 1 g and
weighing capacity > 20 kg, not for verified models
Weighing TablesQuantityOrder number
Made from synthetic stone, with vibration dampening1YWT03
Made from wood with synthetic stone1YWT09
Wall console1YWT04
169EA0040
Accessories (continued)
Climate Modules (available July 2019)QuantityOrder number
Climate module, uncalibrated, for draft shield A or I and user interface MCA1YCM20MC
Calibration of a climate module YCM20MC with DAkkS calibration certificate1YCM20DAkkS
Climate module with DAkkS calibration certificate for draft shield A or I and user interface MCA1YCM20MC-DAkkS
Tower for climate module, for mounting YCM20MC; can be ported to all Cubis II weighing modules
with user interface MCA
Flexible Sample Holder (available July 2019)QuantityOrder number
For weighing vessels and filters with diameters of up to 120 mm, replaces the original weighing pan,
for semi-microbalance and analytical balance
Titanium Holders for Ultra-Micro Balances and Micro Balances (available July 2019)QuantityOrder number
For coronary stents (up to 38 mm)1YSH10
For save-lock tubes, 1.5 ml - 2 ml1YSH13
Titanium Holders for Semi-Micro Balances and Analytical Balances (available July 2019)QuantityOrder number
Q-Grid weighing pan for 10 mg or 100 mg balances1YWP07MS
For save-lock tubes, 1.5 ml – 2 ml
Sartorius de México, S.A. de C.V.
Libramiento Norte de Tepotzotlan s/n,
Colonia Barrio Tlacateco,
Municipio de Tepotzotlan,
Estado de México,
C.P. 54605
Phone +52.55.5562.1102
Fax +52.55.5562.2942
leadsmex@sartorius.com
Asia|Pacific
Australia
Sartorius Australia Pty. Ltd.
Unit 5, 7-11 Rodeo Drive
Dandenong South Vic 3175
Phone +61.3.8762.1800
Fax +61.3.8762.1828
China
Sartorius (Shanghai) Trading Co., Ltd.
rd
3
Floor, North Wing, Tower 1
No. 4560 Jinke Road
Zhangjiang Hi-Tech Park
Pudong District
Shanghai 201210, P.R. China
Phone +86.21.6878.2300
Fax +86.21.6878.2882
Hong Kong
Sartorius Hong Kong Ltd.
Unit 1012, Lu Plaza
2 Wing Yip Street
Kwun Tong
Kowloon, Hong Kong
Phone +852.2774.2678
Fax +852.2766.3526
India
Sartorius Weighing India Pvt. Ltd.
#69/2-69/3, NH 48, Jakkasandra,
Nelamangala Tq
562 123 Bangalore, India
Phone +91.80.4350.5250
Fax +91.80.4350.5253
Japan
Sartorius Japan K.K.
th
4
Fl., Daiwa Shinagawa North Bldg.
8-11, Kita-Shinagawa 1-chome
Shinagawa-ku, Tokyo, 140-0001 Japan
Phone +81.3.3740.5408
Fax +81.3.3740.5406
Malaysia
Sartorius Malaysia Sdn. Bhd
Lot L3-E-3B, Enterprise 4
Technology Park Malaysia
Bukit Jalil
57000 Kuala Lumpur, Malaysia
Phone +60.3.8996.0622
Fax +60.3.8996.0755
Singapore
Sartorius Singapore Pte. Ltd
10 Science Park Road,
The Alpha #02-13/14,
Singapore Science Park II
Singapore 117684
Phone +65.6872.3966
Fax +65.6778.2494
South Korea
Sartorius Korea Ltd.
th
8
Floor, Solid Space B/D,
PanGyoYeok-Ro 220, BunDang-Gu
SeongNam-Si, GyeongGi-Do, 463-400