Sartorius BL150S,BL610,BL6100,BL1500S,BL150,GM1502,GM612,GM312,GM6101 Operating Instructions Manual

98648-007-46
Sartorius Basic
lite
Series
Sartorius Gold Series
Electronic Precision Balances and Gold Scales
2
Practical Use
The Basic
lite
Series and Gold Series from Sartorius offer precision balances/ scales with capacities ranging from 1 mg to 12 kg.
These balances/scales meet the highest requirements on the accuracy and reliability of weighing results through the following features:
Efficient filtering-out of unfavorable
ambient conditions such as vibrations,
drafts, etc. – Stable and reproducible results – Rugged, durable weighing system
Basic
lite
balances and Gold scales save work and speed up simple routine applications through:
Ultrafast response times – Easy operation
You can also choose from the following extra functions for simple applications:
Toggling between weight units – Net-total formulation (tare memory) – Counting – Weighing in percent – Averaging
Contents
Practical Use ................................... 2
Contents ......................................... 2
Warning and Safety Information ........ 2
Getting Started ................................ 3
Operating the Balance/Scale
Basic Weighing Function ................... 6
Calibration/Adjustment ..................... 7
Application Programs
Counting ......................................... 8
Weighing in Percent .........................10
Averaging .......................................12
Net-Total Formulation/Second
Tare Memory ...................................14
Toggle between Weight Units .............15
Configuring the Balance/Scale
Setting the Parameters (Menu Codes) ...16 Balance/Scale Operating Menu
(Overview) ......................................17
Error Codes .....................................18
Care and Maintenance ..................... 19
Instructions for Recycling ....................19
Overview
Specifications ..................................21
Accessories (Options) ........................22
C Marking .....................................23
Warning and Safety Information
Read these operating instructions thoroughly before using your balance/ scale to prevent damage to the equipment. Keep these instructions in a safe place.
Follow the instructions below to ensure safe and trouble-free operation of your balance/scale:
! Make sure that the voltage rating
printed on the AC adapter is identical to your local line voltage
! Use only a commercially available
9-volt block battery or rechargeable battery
! Do not use this balance/scale
in a hazardous area/location
The only way to turn the power
off completely is to disconnect the AC adapter
Connect only Sartorius accessories
and options, as these are optimally designed for use with your balance/ scale.
Protect the AC adapter from contact
with liquid.
Do not open the balance/scale housing. If the seal is broken, this will result in forfeiture of all claims under the manufacturer’s warranty.
3
Getting Started
Warranty
Do not miss out on the benefits of our full warranty. Complete the warranty registration card, indicating the date of installation, and return the card to your Sartorius office or dealer.
Storage and Shipping Conditions
Do not expose the balance/scale to shocks, vibrations, moisture or extreme temperatures.
Unpacking the Balance/Scale
§ After unpacking the balance/ scale, check it immediately for any visible damage as a result of rough handling during shipment.
$ If you see any sign of damage,
proceed as directed in the chapter entitled “Care and Maintenance,” under the section on “Safety Inspection.”
Save the box and all parts of the packaging until you have successfully installed your balance/scale. Only the original packaging provides the best protection for shipment. Before packing your balance/scale, unplug all connected cables to prevent damage.
Equipment Supplied
The equipment supplied includes the components listed below:
Balance/scale – Weighing pan/load plate – Pan support (only with models that
have a round weighing pan)
Glass draft shield
(only with model BL150S)
AC adapter – Operating instructions
Installation Instructions
Your balance/scale is designed to provide reliable weighing results under normal ambient conditions. When choosing a location to set up your balance/scale, observe the following so that you will be able to work with added speed and accuracy:
Set up the balance/scale on
a stable, even surface
Avoid placing the balance/scale
in close proximity to a heater or otherwise exposing the balance/ scale to heat or direct sunlight
Protect the balance/scale
from drafts that come from open windows or doors
Avoid exposing the balance/scale
to extreme vibrations during weighing
Protect the balance/scale from
aggressive chemical vapors
Do not expose the balance/
scale to extreme moisture over long periods
Conditioning the Balance/Scale: Moisture in the air can condense on the surfaces of a cold balance/scale whenever it is brought into a substan­tially warmer place. If you transfer the balance/scale to a warmer area, make sure to condition it for about 2 hours at room temperature, leaving it unplugged from AC power.
4
Setting up the Balance/Scale
Basic
lite
Balances with a Glass Draft Shield:
§ Place the components listed below on the balance in the order given:
Shield ring – place it on the balance so that
the edge for fitting the glass draft shield faces upwards and turn it until it is firmly in place.
Pan support – Weighing pan – Glass draft shield – Draft shield cover
Basic
lite
Balances/Gold Scales with
a Round Weighing Pan
§ Place the components listed below on the balance in the order given:
Pan support – Weighing pan/load plate
Basic
lite
Balances/Gold Scales with
a Rectangular Weighing Pan
§ Place the weighing pan/load plate on the balance/scale
Connecting the Balance/Scale to AC Power/ Safety Precautions
Use only – Original Sartorius AC adapters
§ Insert the right-angle plug into the jack
§ The AC adapter rated to Class 2 can be
plugged into any wall outlet without requiring any additional safety precautions
The ground is connected to the balance/scale housing, which can be additionally grounded for operation.
5
Using a (Rechargeable) Battery
$ Battery is not included with the equipment
supplied
! Use only a commercially available
(rechargeable) 9-volt block battery
! When using a rechargeable battery, always use
an external recharging device to recharge the battery
§ Lay the balance/scale on its side
§ Open the battery compartment: Lift the
compartment cover
§ Insert the 9-volt (rechargeable) block battery in the compartment
$ Make sure to connect the positive and negative
poles correctly
! All used batteries are classified as waste
that requires special handling (not “household” waste). Dispose of rechargeable batteries in accordance with the applicable special waste disposal regulations.
§ Close the battery compartment: Press down on the cover until it clicks into place
Leveling the Balance/Scale
(only for models BL150S, BL1500S, GM1502) Level the balance/scale any time you set
it up in a new location. Use only the 2 front feet of the balance/scale for leveling.
§ Turn the 2 rear feet until they are in position (only on models BL1500S and GM1502)
§ Turn the 2 front feet as shown here in the illustration until the air bubble is centered in the level indicator
> In most cases this will require several
adjustment steps
6
Operating the Balance/Scale
Basic Weighing Function
Available Features
Taring the balance/scale
You can tare the balance within the entire weighing range.
Preparation
§ Turn on the balance/scale: Press e
§ To change configurations: See the chapter entitled
“Configuring the Balance/Scale”
§ To load factory-set configurations: See “Configuring the Balance/Scale,” parameter 9 – 1
$ To tare the balance/scale: Press t Additional Functions
§ To turn off the balance/scale: Press e
Example
Basic weighing Menu code settings: Factory-set codes Step Key (or instruction) Display
1. Turn on the balance/scale e Self-test is performed
2. Place container on balance/ + 52.0 g scale (here: 52 g)
3. Tare the balance/scale t + 0.0 g
4. Place sample in container on + 150.2 g balance/scale (here: 150.2 g)
7
Calibration/Adjustment
*
Always calibrate/adjust the balance/scale after setting it up in a new location.
Available Features
Calibration/adjustment can only be performed when – there is no load on the balance/scale, – the balance/scale is tared, – the internal signal is stable.
If these conditions are not met, an error message is displayed. The weight required for calibration/adjustment is displayed (see “Accessories” for calibration weights).
On Basic
lite
balances, calibration/adjustment can be performed with any of three weight units: g, kg, or lb (menu code 1. 4. x) Factory setting: Grams (menu code 1. 4. 1)
Example
Calibrate the balance/scale Menu code settings: Factory-set codes
Step Key (or instruction) Display
1. Turn on the balance/scale e
2. Tare the balance/scale t 0.0 g
3. Begin calibration t +1000.0
>2 sec. Calibration weight is displayed without weight unit (here: 1000 g)
4. Place the indicated calibration 1000.0 weight on the balance/scale
After calibration, the calibration +1000.0 g weight is displayed with wt. unit
5. Remove the calibration weight 0.0 g
*
“Calibration” technically means to determine the difference between the balance readout and the actual weight on the pan to determine the accuracy. Adjustment means to bring a balance into the state of accuracy required for its use. Therefore, “calibration,” as used in this manual, actually means “adjustment.”
8
Application Programs
Counting
Purpose
With the Counting program you can determine the number of parts that each have approximately equal weight.
Available Features
Store the current weight value to have it loaded
as the preset reference sample quantity next time you initialize the Counting application
The reference sample quantity can be changed
in the operating menu: See “Configuring the Balance/Scale”
The average piece weight is automatically
output via the optional data interface port after initialization, if the menu code for “Printout with data ID codes” is set
Press v to toggle the display between piece
count and weight
Factory Settings
Reference sample quantity: 10 (menu code 3. 3. 2)
Preparation
§ Configure the Counting application in the operating menu: See “Configuring the Balance/Scale” Menu code 2. 1. 4 Counting
§ Reference sample quantity:: Menu code 3. 3. 1 5 pcs Menu code 3. 3. 2 10 pcs Menu code 3. 3. 3 20 pcs Menu code 3. 3. 4 50 pcs Menu code 3. 3. 5 100 pcs
See also “Configuring the Balance/Scale”