Sargent and Greenleaf AX01100 User Manual

Operating Instructions
Model AX26-2xx with 6120-27x Quick Mount Keypad
e audit features, peripheral devices and accessories, soware features, one-time code functionality, USB func­tionality, wireless functionality, remote functionality, Bluetooth functionality, and other additional features are
Model AX26-3xx with 6120-23x One Battery Keypad
www.sargentandgreenleaf.com
* “x” denotes sales variations, such as color.
NOTE:
beyond the scope of the UL 2058 standard and not part of the UL Listing.
Opening the Lock using the Factory Default Code (Keypad)
e factory default Master Code or “Your Code” is 1 2 3 4 5 6. To open the lock, enter 1 2 3 4 5 6 # then turn safe handle.
Set Keypad Beeper Volume
7 8 * MASTER CODE # (QQQQQ) volume value # (QQQ) volume value # (QQQ)
Note: volume value is 0 for “OFF” OR 1 for “LOW” OR 2 for “HIGH”
e following procedure should be evaluated and performed before changing the factory default master code(1 2 3 4 5 6). Once the master code has been changed for the rst time, these procedures are disabled.
Note: Some locks are shipped with an Management Reset Code (MRC) envelope. e MRC is an 8
digit number that is used to recover a lost Master Code (Main Administration code). If the envelope is not enclosed, the lock does not have an MRC or may be retained by the safe manufacture.
Set or Change the MRC
6 7 * 1 2 3 4 5 6 # (QQQQQ) NEW 8-DIGIT MRC # (QQQ) NEW 8-DIGIT MRC # (QQQ)
Delete the Lock’s MRC
6 7 * 1 2 3 4 5 6 # (QQQQQ) # (QQQ) # (QQQ)
Disable the Time Delay Override Function
8 3 * 1 2 3 4 5 6 # (QQQQQ) 1 # (QQQ) 1 # (QQQ)
Changing Your Code or the Factory Default Code
2 2 * (or 3 3 *) YOUR OLD CODE # (QQQQQ) NEW CODE # (QQQ) NEW CODE # (QQQ)
Identifying Active or Created PIN Positions
7 7 * ANY PIN NUMBER (0 – 9) Note: e PIN Postion is the location in the lock which the combinaiton is stored. If the entered PIN Position is in use the lock will emit one short beep. If the PIN Position in not in use or disabled, the lock will emit one long beep.
Sargent & Greenleaf S.A.
Sargent & Greenleaf, Inc.
One Security Dr. Nicholasville, KY 40340-0930 USA Phone: (800)-826-7652 Fax: (800)-634-4843
9, Chemin du Croset
Phone: +41-21 694 34 00
Fax: +41-21 694 34 09
Document 630-9323
Revised 08/01/2018
Creating New Codes/Additional Code (Supervisor or User Code)
7 4 * MASTER OR SUPERVISOR CODE # (QQQQQ) PIN # (QQQ) NEW CODE # (QQQ) NEW CODE # (QQQ ) PIN Positions: 1 Supervisor Code (Supervisor Code can only be created by the Master Code), 2 – 9 User Codes (User Code 9 only performs as a regular User Code when the time delay override feature is turned o).
Deleting a Code (Supervisor or User Code)
7 4 * MASTER CODE OR SUPERVISOR CODE # (QQQQQ) PIN # (QQQ) # (QQQ) # (QQQ) PIN Positions: 1 Supervisor Code, 2 – 9 User Codes Note: e Master Code cannot be deleted. e Supervisor Code cannot delete itself. If the lock is using time delay, the time delay override code can only be deleted during an opening window.
Changing the Length of the Opening Window
7 4 * MASTER CODE # (QQQQQ 0 1 # (QQQ ) LENGTH OF OPENING WINDOW # (QQQ ) LENGTH OF OPENING WINDOW # (QQQ) Note: e opening window period can be set anywhere from 1 to 15 minutes. If the lock is using time delay, the opening window period can only be changed during an opening window period.
Setting, Changing, or Deleting a Time Delay
7 4 * MASTER CODE # (QQQQQ) 0 0 # (QQQ) LENGTH OF TIME DELAY # (QQQ) LENGTH OF TIME DELAY # ( ) Note: e time delay period can be set anywhere from 1 to 99 minutes. An existing time delay can only be changed during an opening window period. To delete a time delay, enter the length of desired time delay as zero.
Creating a Time Delay Override Code
7 4 * MASTER CODE OR SUPERVISOR CODE # (QQQQQ) 9 # (QQQ) NEW TIME DELAY OVERRIDE CODE # (QQQ) NEW TIME DELAY OVERRIDE CODE # (QQQ) Note: e Time Delay Override Code only works if Time Delay Override is turned on and the lock has a time delay period programmed. If the lock is already using time delay, the time delay override code can only be cre­ated during an opening window period.
Turning On Time Delay Override Function
4 6 * MASTER CODE # (QQQQQ) 1 for Dual Control TDO or 2 for Single Control TDO # (QQQ ) 1 for Dual Control TDO or 2 for Single Control TDO # (QQQ ) Note: Type 1 override requires entry of any valid lock code to start the time delay followed by entry of the Time Delay Override Code within one minute to open the lock. Type 2 override simply requires entry of the Time Delay Override Code to open the lock immediately.
Turning O Time Delay Override Function
4 6 * MASTER CODE # (QQQQQ) 0 # (QQQ) 0 # (QQQ) Note: e Time Delay Override Code (PIN 9) will be automatically deleted.