Page 2
http://www.sapido.com.tw USER MANUAL V1.0
2
TABLE OF CONTENTS
1 GETTING TO KNOW THE SWITCH 5
1.1 Introduction 5
1.2 Key Features 5
1.3 The Front Panel 5
1.3.1 Network Ports 5
1.3.2 Cabling 5
1.3.3 LEDs status 6
1.4 The Rear Panel 6
1.4.1 Power Connector 6
2 USEFUL TIPS 7
2.1 Prior to Installation 7
2.2 Half- and Full-Duplex 7
2.3 Auto-Negotiation 7
3 PRODUCT SPECIFICATIONS 9
Page 3
http://www.sapido.com.tw USER MANUAL V1.0
3
FCC Statement
Federal Communication Commission Interference S tatement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does caus e harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
1. The device complies with Part 15 of the FCC rules. Operation is subject to the following conditions:
2. This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation.
3. FCC RF Radiation Exposure Statement: The equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
4. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
5. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment.
IMPORTANT NOTE
FCC Radiation Exposure S tatement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled e nvironment. This equipment should be installed and operated with minimum distance20cm between the radiator & your body.
Page 4
http://www.sapido.com.tw USER MANUAL V1.0
4
CE Mark Warning
This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
National Restrictions
Frequency range - 2400.0 - 2483.5 MHz
Country Country Reason/remark Bulgaria none
General authorization required for outdoor use and public service.
France
Outdoor use limited to 10 mW e.i.r.p. within the band 2454-2483.5 MHz
Military Radiolocation use. Refarming of the 2.4 GHz band has been ongoing in recent years to allow current relaxed regulation. Full implementation planned 2012.
Italy none
If used outside of own premises, general authorization is required.
Luxembourg none
General authorization required for network and service supply (not for spectrum).
Norway Implemented
This subsection does not apply for the geographical area within a radius of 20 km from
the centre of Ny-Ålesund. Russian Federation
none Only for indoor applications.
Note: Please don’t use the product outdoors in France
CE Statement of Conform i ty
Our product has been tested in typical configuration by Ecom Sertech Corp and was found to comply with the essential requirement of "Council Directive on the Approximation of the Laws of the Member Sates relating to Electromagnetic Compatibility" (89/336/EEC; 92/31/EEC; 93/68/EEC). The Declaration of Conformity can be found at the Sapido regional website. www.sapidotech.de
CE Information of Disposal
The electric and electronic equipment or unit which is labeled with crossed-out wheeled bin may not be disposed of with household waste. This mark is based on European Directive 2002/96/EC (for Waste Electric and Electronic Equipment=WEEE). Please take it to the designated collection facilities. We will ensure the proper recycling, reuse and other forms of recovery of WEEE. WEEE has the potential effects on the environment and human health as a result of the presence of hazardous substances. You can contribute to eliminate these effects by your cooperation.
Page 5
http://www.sapido.com.tw USER MANUAL V1.0
5
1 Getting to know the Switch
1.1 Introduction
The Gigabit Ethernet Switch is equipped with 16 Gigabit copper ports and each port provides a max speed of 2000Mbps and a Full-Duplex, Collision Free Bandwidth. It’s a multi-speed, versatile network device that combines Gigabit, Fast Ethernet, and Ethernet ports in a single device. This device meets RoHS compliance. It is power-saving with Green Ethernet technology.
1.2 Key Features
Supports Auto-Negotiation on each TP port Supports 9216byte maximum packet length Supports Green Ethernet
Link-On and Cable Length Power Saving Link-Down Power Saving
IEEE 802.3az Energy Efficient Ethernet (EEE) supported Provides Store-and-Forward switching scheme Supports Auto-MDI/MDI-X function Supports IEEE 802.3x Flow-Control for Full-Duplex operation Back-Pressure function supports for Half-Duplex operation Non-Blocking Performance Improves Access to Network Resources 8K-entry lookup MAC address table
1.3 The Front Panel
1.3.1 Network Ports
The Switch is equipped with eight RJ-45 ports that support network speeds of 10/100/1000Mbps.
1.3.2 Cabling
1000Mbps - To transmit at 1000Mbps requires Cat.5 TP cabling that has all Four (4)
twisted-pair wires connected in RJ45 connector.
100Mbps - To transmit at 100Mbps requires Cat. 5 cabling. 10Mbps - When transmitting at 10Mbps, Cat. 3, 4 or 5 TP cabling with RJ-45 sockets
can be used.
Page 6
http://www.sapido.com.tw USER MANUAL V1.0
6
Port Type Cable Type Connector 1000BASE-T Cat.5 TP RJ-45 100BASE-TX Cat.5 TP RJ-45
10BASE-T Cat. 3, 4 or 5 TP RJ-45
Note: Cat. 5 TP cable recommended whenever installing new cabling.
1.3.3 LEDs status
Information about the Switch’s activity is displayed through its LEDs, shown as below.
LED Function Color Status Description
Green On Power is being applied to this product
Power x1
Power indication
and loop status
Red
Blinking
120ms
Loop is detected
On Connected at 1000Mbps
Orange
Blinking
30ms
1000Mbps Tx/Rx activity or loop detected
On Connected at 10/100Mbps
Port x 16
Ethernet port
activity and loop
status
Green
Blinking
30ms
10/100Mbps Tx/Rx activity
1.4 The Rear Panel
1.4.1 Power Connector
The power connector is designed to be used with the power adapter included in the product package.
Page 7
http://www.sapido.com.tw USER MANUAL V1.0
7
2 Useful Tips
2.1 Prior to Installation
Before installing the switch and connecting network devices, it is important to plan the network's layout. Things you should consider include: Dedicated Bandwidth: File servers and other high-traffic hardware will have better
and improved performance if they have their own dedicated 10Mbps, 100Mbps, or 1000Mbps bandwidth.
Full-Duplex: Determine which devices support Full-Duplex connections.
Fast Ethernet & Gigabit Ethernet: Make sure rules for cable lengths and categories
are followed. 100BASE-TX and 1000BASE-T have the same rules for cable and distance.
Auto-Negotiation: Devices with different speeds may be easily swapped when the
other end of the cable is fixed to a port with Auto-Negotiation.
2.2 Half- and Full-Duplex
The switch supports both Half- and Full-Duplex modes for 10BASE-T and 100BASE-TX. But the 1000BASE-T only supports Full-Duplex mode. In Half-Duplex mode: Data cannot be transmitted and received at the same time.
Attached devices must finish transmitting data before they can receive data.
In Full-Duplex mode: Data can be transmitted and received at the same time. However:
Full-Duplex transmission is only possible between two devices with a dedicated link
(e.g., Switch-Switch, Switch-PC)
Both devices must have Full-Duplex capability Both devices must be set to Full-Duplex (e.g. Auto-Negotiation – Auto-Negotiation,
Non-Auto-Negotiation to Non-Auto-Negotiation) The 10/100/1000Mbps ports on the switch detect and set the line's operating mode by using their Auto-Negotiation function.
2.3 Auto-Negotiation
Every 10/100/1000Mbps port on the switch has a built-in "Auto-Negotiation" function. This technology allows each port to automatically sense and set the best possible speed as soon as a connection with another network device is established (usually at Power “On” or Reset).
Evaluating Auto-Negotiation Capability:
if attached device is: The switch will automatically set its TP ports to operate at: 1000Mbps
with Auto-Negotiation
2000Mbps (1000BASE-T, Full-Duplex) Note: Almost all 1000Mbps devices only operate in Full-Duplex mode.
Page 8
http://www.sapido.com.tw USER MANUAL V1.0
8
100Mbps no Auto-Negotiation
100Mbps (100BASE-TX, Half-Duplex)
100Mbps with Auto-Negotiation
200Mbps (100BASE-TX, Full-Duplex)
10Mbps no Auto-Negotiation
10Mbps (10BASE-T, Half-Duple x)
10Mbps with Auto-Negotiation
20Mbps (10BASE-T, Full-Duplex)
Note: If the attached device is set to a fixed mode (ex: Forced Full-Duplex) it will not operate as an Auto-Negotiation device.
Page 9
http://www.sapido.com.tw USER MANUAL V1.0
9
3 PRODUCT SPECIFICATIONS
Item Specification
Key Components
Chipset
Realtek RTL8376 16-port Gigabit switch controller Realtek RTL8218 8-port Gigabit PHY
Ethernet Interfaces
Standards
IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Fast Ethernet IEEE 802.3ab 1000Base-T Gigabit Ethernet IEEE 802.3x Flow Control
Ethernet Port
16 x 10Base-T/100Base-TX/1000Base-T Gigabit Ethernet ports Supports Auto-MDI/MIDX and Auto-Negotiation Supports 10Base-T: Category 34 or 5 TP Supports 100Base-TX/1000Base-T : Category 55e TP or higher
Transfer Mode
Store-and-Forward
Packet Buffer Size
2Mbits
MAC Address T able
8K-entry lookup table
Bandwidth
10BASE-T: 1 0 / 20Mbps (half/full duplex) 100BASE-TX: 100/200Mbps (hal f/full duplex) 1000BASE-T: 2000Mbps (full duplex)
Forwarding/Filtering Rate
14881 packets/second per port @ 10Mbps maximum 148810 packets/second per port @ 100Mbps m a ximum 1488095 packets/second per port@1000Mbp s m a ximum
Switch Fabric
32Gbps
Jumbo Frame
Supports maximum 9216bytes packet length
Green Ethernet
Link-On and Cable Length Power Saving Link-Down Power Saving IEEE 802.3az Energy Efficient Ethernet (EEE)
Miscellaneous
LED Indicators
Power/Loop x 1 Port Link/Act/Loop x 16
Operation Requirement
Operating Temp. 攝氏 0 to 40 度(華氏 32 to 104 度) Storage Temp. 攝氏-20 to 70 度(華氏-4 to 158) Operating Humidity 10% to 85% Non-Condensing Storage Humidity 5% to 90% Non-Co ndensing
Page 10
http://www.sapido.com.tw USER MANUAL V1.0
10
Power Supply
AC100~240V / 50~60Hz universal input
Dimensions
250(L) x 148.8(W) x 43(H) mm