General Instructions
• Instrument shouldn’t block the material filling inlet.
• Secure the cover of housing tightly. Tighten the cable glands. For side mounting, the cable glands should point downwards.
• For side mounting, provide a baffle to prevent the material from falling on the probe.
• When handling forks, do not lift them using their tines. While using them with solids, ensure that material size is less than 10mm.
• Deforming the shape of the tines may interfere with the fork’s operating frequency.
• Make all electrical connections as instructed in the manual. Don’t power on the device before verifying the connections.
R
Sapcon Instruments Pvt.Ltd.
4
1Introduction
193
143
68
50
44
32
For Hygienic Application:
Surface Finish in Ra = 0.8µm
Elixir-T-Uni is a Vibrating Fork Level Limit Switch for
liquids. It is suitable for level detection in storage tanks,
mixing container and pipelines, for all kinds of liquid which
do not react with SS 316, viscosity does not exceed
10,000 cP and temperature lies within 0◦C to 80◦C. It is
suitable for most of the applications where float switches
were previously employed, as well as in places where
float switches were not appropriate (due to deposition,
turbulence, stresses and air bubbles). Elixir-T-Uni ignores
foam deposition on its fork tines.
User Manual & Datasheet V 2.1
4Features
• Power Supply: 18-30 V DC
• Output: Open collector PNP, LED Indication
• Operational temperature: 0
• Hygienic finish with 0.8 Ra available
• No calibration required at site, easy to install
• Compact in size
• Service friendly plug-in connection
• Rugged stainless steel housing
• Operational safety ensured
• Immune to foam build-up
• External circuit testing by test magnet
◦
C to 150◦C (Fork)
Figure 1: Elixir-T-Uni
2Operating Principle
Elixir-T-Uni works on the principle of continuous vibration
of the fork at its natural frequency. A specially shaped
Tuning Fork is kept vibrating by piezo electric element.
The resonance frequency changes when the tines are
immersed in any fluid.The change in frequency is detected
and used is for switching.
5Applications
Elixir-T-Uni is suitable for the following applications and
industries:
• Chemicals
• Pesticides
• Edible Oil
• Food Industry
• Dairy Industry
• Packaging Industry
• Pharmaceutical
• Breweries
Industry
6Dimensional Layout
Dimensional drawing for a fork length of 44 mm is shown
in Figure 3
Figure 2: Part Diagram
3System Description
Elixir-T-Uni vibrating fork level switch detects the resonant frequency change and changes the output signal
according to fail-safe mode selection. Typically, the output
is fed to a PLC which then uses it to control the process.
Sapcon Instruments Pvt.Ltd.
R
Figure 3: Dimensional Diagram
(All dimensions in mm)
5
User Manual & Datasheet V 2.1
7Electrical Specifications
Please refer to Table 1 for Electrical Specifications.
PARAMETERVALUE
Input Power Supply18-30 V DC
OutputOpen Collector - PNP Output (Load capacity upto 90 mA at
24 V DC)
Switching IndicationRed /Green LED ON/OFF
Switching Behavior
• ON
• OFF
Fail-safe FeatureField selectable
• Fail-safe High ( For Overflow Protection)
• Fail-safe Low (For Dry Run Protection)
Power ConsumptionWithout Load
• 480 mW @ 24 V DC
• 168 mW @ 12 V DC
With Load
3W @ 24 V DC
Table 1: Electrical Specifications
8Application Specifications
Please refer to Table 2 for Application Specifications.
PARAMETERVALUE
Response Time
• Covered
• Uncovered
Repeatability± 0.5mm
Switching Hysteresis*3mm ± 0.5mm
Fork Resonance Frequency*1500Hz approx.
Minimum Liquid Density0.7gm/cc
Maximum Viscosity of Liquid10,000 cp
Solid Content Diameter< 5mm
Temperature
• Ambient
• Process
Value
• 0.5 second
• 1 second
Value
◦
• 0
C to 60◦C
◦
• 0
C to 150◦C
Table 2: Application Specifications
* The reported values have been found with water as application medium, at room temperature.
R
Sapcon Instruments Pvt.Ltd.
6
User Manual & Datasheet V 2.1
9Mechanical Specifications
Please refer to Table 3 for Mechanical Specifications.
PARAMETERVALUE
Housing PipeSS 316 housing, Weatherproof with integral probe mount-
ing (IP65)
Mounting
• Thread Mounting: 1/2”, 3/4”, 1” BSP / NPT
• Flange Mounting: As per user specification
• Tri-Clamp: As per user specification
• Hygienic Flash Mounted Socket, SS 316 with 1” BSP
Electrical ConnectorValve Connector
Gland TypePG 11, PG 9 cable gland
DimensionRefer to Figure 3
Active Fork Length44 mm and 100 mm
Probe Length
• 68 mm, 105 mm, 125 to 1000 mm {For 44 mm Fork
Length}
• 126 mm {For 100 mm Fork Length}
Process TemperatureUp to 150◦C
Sensing Fork MaterialSS 316
Fork Finish
• Hygienic Fork
• Standard Fork
PressureUp to 10 Bar
Table 3: Mechanical Specifications
Sapcon Instruments Pvt.Ltd.
R
7
User Manual & Datasheet V 2.1
10Installation Guidelines
Note: Elixir-T-Uni does not have any keys to operate.The Fail-safe feature has been implemented in
accordance with connection.
10.1
order mentioned below -
Procedure for Installation
For quick and easy installations, follow the steps in the
• Remove the female socket from the top of Elixir-T-Uni
(Use Screw Driver) and you can see that there are four
pins of male socket on Elixir-T-Uni.
• Remove the cap from the female socket by using screw
driver.
10.2
10.2.1
instructions given below for Electrical Connections -
Electrical Connections
For Fail-safe High
If a device is mounted at top of the tank then follow the
• First of all connect the positive terminal to pin no. 3 of
the device.
• Now connect the negative terminal to pin no. 1 of the
device.
• Connect fuse between positive terminal and pin no. 3
of the device.
• Between pin no. 1 and 2 the output can be taken.
• Connect all the wires from cable entry to male socket
pin through cap.
• Plug-in Elixir-T-Uni to female socket.
Figure 4: Fail-safe High
10.2.2
If a device is mounted at bottom of the tank then follow
the instructions given below for Electrical Connections -
For Fail-safe Low
• First of all connect the positive terminal to pin no. 2 of
the device.
• Now connect the negative terminal to pin no. 1 of the
device.
• Connect fuse between positive terminal and pin no. 2
of the device.
• Between pin no. 1 and 3 the output can be taken.
• Mount the device with the help of Mounting Socket.
R
Sapcon Instruments Pvt.Ltd.
Figure 5: Fail-safe Low
8
Note: Elixir-T-Uni is compatible only with 24V DC
power supply.
User Manual & Datasheet V 2.1
10.3
change and when the magnet is released from the target area the status of the switching LED and PNP output is switched to
there previous (original) state.
10.4
Output Check Test
Hold the magnet at the target place of the instrument, the current status of the switching LED and the PNP output will
Output Indications
Green LED Glows When:
• Fork is Uncovered and Fail-safe is High
• Fork is Covered and Fail-safe is Low
Red LED Glows When:
• Fork is Covered and Fail-safe is High
• Fork is Uncovered and Fail-safe is Low
10.5
1. Temperature
LED ERROR INDICATIONDESCRIPTIONTROUBLESHOOTING
Red and Green LEDs Glows
Permanently
Error Indications
• Blue LED glows when temperature of electronic insert goes above 120
No Calibration
◦
C.
All LEDs OFFLow Voltage (Below 10V)Increase Voltage
Green LED Blinks (1 Second)It is because of Serial Communication Stop Serial Communication
Red LED Blinks (20 Seconds)Oscillator Failed/Fork is not connected
Blue LED Blinks Slowly (1 Second)Temperature goes above 100◦C
Blue LED Blinks Fast (300 MiliSeconds)
Blue LED Glows PermanentlyTemperature goes above 120◦C
2. Fork Stops Vibrating
Temperature goes above 110◦C
Table 4: Error Indications
• When Red LED blinks continuously and Fail-safe is High
• When Green LED blinks continuously and Fail-safe is Low
Troubleshooting: The following reasons may be responsible for the absence of vibrations in the fork:
• The instrument is damaged.
• The instrument is working but there may be solid particles in the application medium clogging the fork.
• Heavy build-up of application medium can dampen the fork oscillations. In this case, the fork requires to be cleaned.
• If material is very viscous, the fork vibrations will resume when the fork is uncovered. In this case, the error
indication should be ignored.
3. No LED Glows
• This would happen in absence of power supply to the instrument.
R
Sapcon Instruments Pvt.Ltd.
9
User Manual & Datasheet V 2.1
11Customer Support
Thank you for going through the instructions given in this manual. To further ease the process of installation and use, we
have developed special demo videos which are hosted on YouTube.
Sapcon’s YouTube channel, SAPCON INSTRUMENTS, lists all these videos: https://goo.gl/dnxfcz
Should you require further information regarding installation, use or working of the instrument, please don’t hesitate to contact
us. Kindly provide the following information at the time of contacting:
• Instrument Model and Serial Number
• Purchase Order Number and Date of Purchase
• Description of the query
• Your contact details
In an attempt to serve you better, we are open seven days a week (9:30am to 7:30pm). We are available at:
• www.sapconinstruments.com
• sales@sapcon.in
• +91-731-4757575
Sapcon Instruments Pvt.Ltd.
R
10
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.