SANYO VPC-S60EX, VPC-S60 DISASSEMBLY

Page 1

2. DISASSEMBLY

2-1. REMOVAL OF CABI BACK, LCD AND CABI FRONT
1. Two screws 1.7 x 3.5
2. Three screws 1.7 x 4
3. Two screws 1.7 x 3
4. Cabi back
5. Holder battery
7. LCD
8. FPC
9. Remove the solder.
10. Two screws 1.4 x 3.5
11. Cabi front
6
4
7
10
1
11
2
NOTE: Discharge a strobe capacitor
with the discharge jig (VJ8-0188) for
electric shock prevention.
9
2
8
5
3
– 12 –
Page 2
2-2. REMOVAL OF HOLDER MONITOR
1. Spacer TB1
2. Spacer power switch
3. Screw 1.4 x 2.5
4. Earth shaft
5. Two screws 1.4 x 3
6. Two screws 1.4 x 3
7. Holder monitor
8. Earth dec lens
9. Screw 1.4 x 3
10. Earth switch back
1
11. Spacer CP1
12. Speaker, 8
13. Remove the solder.
14. Screw 1.4 x 3
15. Screw 1.4 x 3
16. Stand
17. Remove the solder.
18. Microphone
19. Spacer lens top
5
10
2
19
6
9
18
3
15
11
4
7
14
17
8
16
13
12
– 13 –
Page 3
2-3. REMOVAL OF TB1 BOARD, LENS ASSEMBLY AND CP1 BOARD
1. Remove the solder.
2. Remove the solder.
3. Two screws 1.4 x 3
4. TB1 board
5. Remove the solder.
6. Remove the solder.
7. Three screws 1.4 x 3
8. Remove the solder.
9. Assy lump
4
11
13
10. Condensor
11. Two screws 1.7 x 2.5
12. Terminal battery B
13. Terminal battery A
14. Holder battery
15. Three screws 1.4 x 3.5
16. FPC
17. Lens assembly
18. CP1 board
3
1
12
2
18
7
9
5
15
a
b
c
6
8
14
16
17
When assembling,
tighten the screws order.
a b c
10
– 14 –
Page 4
2-4. BOARD LOCATION
TB1 board
CP1 board
– 15 –
Page 5

3. ELECTRICAL ADJUSTMENT

3-1. Table for Servicing Tools
Ref. No.
J-1
J-2
J-3
J-4
J-5
J-6
Pattern box (color viewer)
Calibration software
Chroma meter
Spare lump
Discharge jig
Collimator
Name
J-1 J-2
J-3
Number
1
1
1
1
1
1
J-4
Part code
VJ8-0190
VJ8-0273
VJ8-0192
VJ8-0191
VJ8-0188
VJ8-0260
3-4. Setup
1. System requirements
Windows 98 or Me or 2000 or XP IBM R -compatible PC with pentium processor CD-ROM drive USB port 40 MB RAM Hard disk drive with at least 15 MB available VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation CD-ROM into your CD-ROM drive.
2. Open the explorer.
3. Copy the DscCalDI_152 folder on the CD-ROM in the CD­ROM drive to a folder on the hard disk.
3. Installing USB driver
Install the USB driver with camera or connection kit for PC.
4. Pattern box (color viewer)
Turn on the switch and wait for 30 minutes for aging to take place before using Color Pure. It is used after adjusting the chroma meter (VJ8-0192) adjust color temperature to 3100 ± 20 K and luminosity to 900 ± 20 cd/m the lump and its circumference are high temperature during use and after power off for a while.
2
. Be careful of handling
J-5
3-2. Equipment
1. AC adaptor
2. PC (IBM R -compatible PC, Pentium processor, Window 98 or Me or 2000 or XP)
3-3. Adjustment Items and Order
1. Lens Adjustment
2. AWB Adjustment
3. CCD White Point Defect Detect Adjustment
4. CCD Black Point And White Point Defect Detect Adjust-
ment In Lighted
Note: Item 1-4 adjustments should be carried out in sequence.
5. Computer screen during adjustment
Calibration
AWB
Focus
UV Matrix
Cal Mode
Cal Data
USB storage
VID
Get
PID
Set
Backrush pulse :
OK
OK
Upload
Firmware
Data
PAF Cal.
EVF
LCD Type
Get
LCD
R Bright
RGB Offset
Tint
VCO
H AFC Test
Serial
Set
Set
B Bright
Gain
Phase
Rev.
Set Set
Set
VCOMDC
VCOMPP
Hall Cal.
Setting
Language
Video Mode
Factory Code
– 16 –
Page 6
3-5. Connecting the camera to the computer
1. Line up the arrow on the cable connector with the notch on the camera's USB port. Insert the connector.
2. Locate a USB port on your computer.
3. Insert the AC adaptor’s cable to DC adaptor cable. Insert the DC adaptor to the camera.
4. If “USB CONNECTION” is displayed, choose the “CARD READER”, and press the SET button.
NOTE: Discharge a strobe capacitor
with the discharge jig (VJ8-0188) for
electric shock prevention.
AC adaptor
To USB port
USB cable
– 17 –
Page 7
3-6. The adjustment item which in necessary in part exchange
CCD Black Point
Lens
Adjustment
AWB
Adjustment
CCD White Point
Defect Detect
Adjustment
And White Point
Defect Detect
Adjustment In
Lighted
Factory
Cord
Setting
Language
Setting
COMPL PWB CP-1
COMPL PWB TB-1
LENS ASSY
: Be sure to carry out the necessary adjustments after replacing the unit. : Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
3-7. Adjust Specifications
1. Lens Adjustment
DscCalDi x
Focus Result
!
ZOOM_BACKRUSH: 7 AF_WIDE: -10 AF_MID1: -11 AF_MID2: -1 AF_MID3: 10 AF_MID4: 23 AF_TELE: 41 ZOOM_WIDE: 2006 ZOOM_MID1: 2160
Camera
Collimator
ZOOM_MID2: 2315 ZOOM_MID3: 2469 ZOOM_MID4: 2624 ZOOM_TELE: 2766
USB storage
information registration
Reset
Setting
Preparation:
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set the camera 0 cm from the collimator. (Do not enter any
light.)
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Click the Focus, and click the Yes.
5. Lens adjustment value will appear on the screen.
6. Click the OK.
OK
Adjustment value determination is effectuated using the
"ZOOM_BACKRUSH", “AF_WIDE”, “AF_MID1”, “AF_MID2”,
AF_MID3, AF_MID4 and "AF_TELE" values.
Adjustment value determination
ZOOM_BACKRUSH: zoom backrush adjustment value
(0 ~ +40) AF_WIDE: focus adjustment vallue W (-100 ~ +112) AF_MID1: focus adjustment vallue M1 (-45 ~ +112) AF_MID2: focus adjustment vallue M2 (-45 ~ +112) AF_MID3: focus adjustment vallue M3 (-45 ~ +112) AF_MID4: focus adjustment vallue M4 (-45 ~ +112) AF_TELE: focus adjustment vallue T (-26 ~ +112)
– 18 –
Page 8
2. AWB Adjustment
Camera
Pattern box
(color viewer)
Adjusting method:
1. When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer except the white section. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Adjustment value determination
100<a1<300, 250<a2<500, 450<a3<650, 550<a4<850, 750<a5<1023 wc0=128 ± 2, wc1=128 ± 2, wc2=130 ± 40 wfc0=128 ± 2, wfc1=128 ± 2, wfc2=130 ± 40 1200<=ms1<=3500, 1200<=ms2<=3600
Adjustment values other than the above are irrelevant.
3. CCD White Point Defect Detect Adjustment
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “CCD Defect” on the LCD “Test, and click the Ye s ”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
4. CCD Black Point And White Point Defect Detect Adjustment In Lighted
Dsc Calibration
x
OK
AWB Result:
Copy
1: AGC=194,363,535,706,872 4F_AGC=0,0,0 WB=459,521,516 CHECK=127,127,149 WB_FS=459, 522, 520 CHECK_FS=127,128,148 MS=1952,1971 0 IRIS=0 Fno_FOR_ISO=71 SS_FOR_ISO=10025 YLEVEL_FOR_ISO=9656
Adjustment value determination is effectuated using the "AGC", CHECK", CHECK_FS and "MS" values. If AGC=a1, a2, a3, a4, a5, CHECK=wc0, wc1, wc2, CHECK_FS=wfc0, wfc1, wfc2 and MS=ms1, ms2, the adjust­ment values fulfill the conditions below, they are determined as within specifications.
Camera
Pattern box
(color viewer)
Preparation:
Setting of pattern box:
Color temperature: 3100 ± 20 (K) Luminance: 900 ± 20 (cd/m
2
)
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter
any light.)
2. Double-click on the DscCalDi.exe.
3. Select “CCD Black” on the LCD “Test, and click the Ye s ”.
4. After the adjustment is completed, the number of defect
will appear.
5. Click the OK.
– 19 –
Page 9
3-8. Factory Code Setting
1. Check the "Factory Code" display within the Setting group.
2. For U.S.A., Canada and NTSC general area If "FC_SANYO_U" does not appear, click on the " " mark located on the right of the "Factory Code" display BOX and select "FC_SANYO_U".
3. For Europe and PAL general area If "FC_SANYO_EX" does not appear, click on the " " mark located on the right of the "Factory Code" display BOX and select "FC_SANYO_EX".
3-9. Language Setting
1. Click on the " " mark located on the right of the "Language" display BOX.
2. Select language. (Default is English.)
3. End "DscCal" and remove the camera before turning the camera power OFF.
Calibration
AWB
Focus
UV Matrix
Cal Mode
Cal Data
USB storage
VID
Get
PID
Set
Backrush pulse :
OK
OK
Upload
Firmware
Data
PAF Cal.
EVF
LCD Type
Get
LCD
R Bright
RGB Offset
Tint
VCO
H AFC Test
Serial
Set
Set
Rev.
B Bright
Gain
Phase
Set Set
Set
VCOMDC
VCOMPP
Hall Cal.
Setting
Language
Video Mode
Factory Code
3-10. Program data writing to NAND-Memory Carry out program data writing to NAND-memory after replacing CP1 board.
Preparation:
SD card: SD card with data written into the root directory Data: S81RNxxx.bin (xxx: version)
Overwriting method:
1. Insert the above SD card.
2. Turn on the camera.
3. Press the PLAYBACK button.
4. Press the MENU button. The playback menu appears.
5. Press the down arrow button. The option menu appears.
6. Press the left arrow button for 2 seconds. FIRMWARE UPDATE will display.
7. Choose YES.
8. Press the SET button. Update is starting.
Note:
Do not turn off the cameras power or remove the SD card while the firmware is being updated.
3-11. Reset Setting Carry out reset settings after replacing CP1 board.
1. Turn on the camera.
2. Press the MENU button.
3. Choose the OPTION.
4. Choose the RESET SETTINGS, and press the SET button.
5. Select Yes, and press the SET button.
– 20 –
Page 10
3-12. Firmware uploading procedure
1. Uploading the firmware should be carried out if the version number (COMPL PWB XX-X) on the replacement circuit board is lower than the version of the distributed firmware. For XX-X, enter the name of the circuit board containing the firmware.
2. The firmware is distributed by e-mail in self-extracting archive format. Change the extension of the distributed file to .EXE and save it in your preferred folder.
3. When you double-click the saved file, the firmware (binary file) will be saved in the same folder.
4. The firmware must not be distributed without permission.
1. Overwriting firmware from the SD card
Preparation:
SD card: SD card with firmware rewritten into the root direc­tory Data: S81RNxxx.BIN (xxx: version)
Overwriting method:
1. Insert the above SD card.
2. Turn on the camera.
3. Press the PLAYBACK button.
4. Press the MENU button. The playback menu appears.
5. Press the down arrow button. The option menu appears.
6. Press the left arrow button for 2 seconds. FIRMWARE UPDATE will display.
7. Choose YES.
8. Press the SET button. Update is starting.
Note:
Do not turn off the cameras power or remove the SD card while the firmware is being updated. The power will turn on automatically after the update is com­plete.
3-13. The Compulsive boot starting method
1. Keep MENU button, LEFT button, and Playback button de­pressed while switching on the power.
2. Connect the camera and the computer with USB cable.
2. Overwriting firmware from the calibration software Preparation:
PC with overwriting firmware copied to the preferred folder in the HD. Data: S81RNxxx.BIN (xxx: version)
Overwriting method:
1. Connect the camera’s USB/AV terminal to the computer USB connector.
2. The USB Connection screen appears on the cameras LCD monitor. Choose the CARD READER, and press the SET button.
3. Double-click on the DscCalDi.exe.
4. Click the Firmware.
5. Choose the fimware file to use for overwriting, and click the Yes.
5. Update is starting. The message will appear, and choose OK.
6. After the update is complete, disconnect the USB cable and turn the camera’s power off.
Note:
Do not turn off the cameras power while the firmware is be­ing updated.
21