SANYO VPC-S4 Service Manual 01-11

Notice
PRODUCTION CHANGECORRECTION
FILE No.
Please add this notice to the Service manual listed below.
Category : Digital Camera
Model Name Reference No. Destination VPC-S4 SM5310586 Europe, PAL General
VPC-S4U SM5310586 U.S.A., Canada, Korea, Taiwan
The reason of change.
A : Misprint B : Quality Reliability C : Standardization D : Design
E : Deletion F : Addition G : Multiple Use
Page 15 3. ELECTRICAL ADJUSTMENT 3-6. Adjust Specifications
3. AWB Adjustment Adjustment value determination
[OLD]
150<a1<350,
600<a4<850, 800<a5<1024
[ADD]
330<a2<540, 450<a3<680,
[NEW]
150<a1<350,
600<a4<850, 800<a5<1024
310<a2<540, 450<a3<680,
Page 16 3-9. Firmware uploading procedure
1. Uploading the firmware should be carried out if the version number (COMPL PWB XX-X) on the replacement circuit board is lower than the version of the distributed firmware. For XX-X, enter the name of the circuit board containing the firmware.
2. The firmware is distributed by e-mail in self-extracting archive format. Change the extension of the distributed file to .EXE and save it in your preferred folder.
3. When you double-click the saved file, the firmware (binary file) will be saved in the same folder.
4. The firmware must not be distributed without permission.
Date : Nov.18 2004
1. Overwriting firmware from the SD card
Preparation:
SD card: SD card with firmware rewritten into the root direc­tory Data: S716Nxxx.BIN (xxx: version)
Overwriting method:
1. Insert the above SD card.
2. Set the main switch to PLAY.
3. Turn on the camera.
4. Press the MENU button. The playback option screen appears.
5. Choose the OPTION icon.
6. Choose the FORMAT.
7. Press the left key for 2 seconds. FIRMWARE UPDATE will display.
8. Choose YES.
9. Press the SET button. Update is starting.
Note:
Do not turn off the camera’s power or remove the SD card while the firmware is being updated. The power will turn on automatically after the update is com­plete.
SX716/EX, U 126 678 00, 01
SANYO Electric Co., Ltd. Osaka,Japan
2. Overwriting firmware from the calibration software Preparation:
PC with overwriting firmware copied to the preferred folder in the HD. Data: S716Nxxx.BIN (xxx: version)
Overwriting method:
1. Connect the camera to the computer with USB cable. Set the main switch to PC, and turn on the camera. Select OK and press the SET button.
2. Double-click on the DscCalDi.exe.
3. Click the Firmware.
4. Choose the fimware file to use for overwriting, and click the Ye s .
5. Update is starting. The message will appear, and choose OK.
6. After the update is complete, disconnect the USB cable and turn the camera’s power off.
Note:
Do not turn off the camera’s power while the firmware is being updated.
Reference No. SM5310586-01