SANYO VPC-MZ2EX, VPC-MZ2, VAR-GA4U, VAR-GA4EX, VAR-GA4E ELECTRICAL ADJUSTMENT

3. ELECTRICAL ADJUSTMENT

3-1. Table for Servicing Tools
Ref. No. Name
J-1
J-2
J-3
J-4
J-5
Note: J-1 color viewer is 100 - 110 VAC only.
J-1 J-2
J-3 J-4
J-5
Color viewer
Siemens star chart
Calibration software
Spare lamp
Discharge jig
Part code
VJ8-0007
VJ8-0189
VJ8-0028
VJ8-0188
16-3. LCD Gain Adjustment
16-4. LCD Red Brightness Adjustment 16-5. LCD Blue Brightness Adjustment
Note: If the lens, CCD and board in item 12-15, it is neces-
sary to adjust again. Item 12-15 adjustments other than these should be carried out in sequence. For 14 and 15, carry out adjustment after sufficient charging has taken place. In case of carrying out adjustment item 12 and 13 after adjusting item 14 and 15, adjust item 12 and 13 after turing off the power.
3-4. Setup
1. System requirements
Windows 98 or Me or 2000 IBM R -compatible PC with pentium processor CD-ROM drive
3.5-inch high-density diskette drive USB port 40 MB RAM Hard disk drive with at least 15 MB available VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation diskette into your diskette drive.
2. Open the explorer.
3. Copy the DscCalDI_128c folder on the floppy disk in the FD drive to a folder on the hard disk.
3. Installing USB drive
Install the USB drive with camera or connection kit for PC.
3-2. Equipment
1. Oscilloscope
2. Digital voltmeter
3. AC adaptor
3-3. Adjustment Items and Order
1. IC501 Oscillation Frequency Adjustment
2. 5.0 V (D) Voltage Adjustment
3. 3.3 V (D) A Voltage Adjustment
4. 3.4 V (D) B Voltage Adjustment
5. 5 V (A) Voltage Adjustment
6. IC511 Oscillation Frequency Adjustment
7. 3.4 V (D) C Voltage Adjustment 1
8. 3.4 V (D) C Voltage Adjustment 2
9. 12.4 V (L) Voltage Adjustment 1
10. 12.4 V (L) Voltage Adjustment 2
11. CCD VSUB Adjustment
12. AWB Adjustment
13. Lens Adjustment
14. CCD Defect Detect Adjustment
15. CCD Black Point Defect Detect Adjustment
16. LCD Panel Adjustment
16-1. LCD H AFC Adjustment 16-2. LCD RGB Offset Adjustment
4. Color Viewer
1. Turn on the switch and wait for 30 minutes for aging to take place before using Color Pure.
2. The luminance adjustment control on the color viewer should be set to around the middle position (memory 5) during use.
3. The fluorescent lamps which are used in the color viewer are consumable parts. After the cumulative usage time reaches 2000 hours, the color temperature will start to in­crease as the usage time increases, and correct adjust­ment will not be possible. When the cumulative usage time reaches 2000 hours, all of the fluorescent lamps should be simultaneously replaced with new lamps.
5. Computer screen during adjustment
Calibration
AWB
Focus
UV Matrix
Cal Mode
Cal Data
USB storage
VID
Get
PID
Set
OK
OK
Upload
Firmware
Image
Initialize
EVF
LCD Type
LCD
R Bright
RGB Offset
Tint
VCO
H AFC Test
Serial
Set
Set
Rev.
B Bright
Gain
Phase
Set Set
– 15 –
VCOMDC
VCOMPP
Setting
Language
Video Mode
3-5. Connecting the camera to the computer
1. Line up the arrow on the cable connector with the notch on the camera's USB port. Insert the connector.
2. Locate a USB port on your computer.
USB cable
To USB port
AC adaptor
– 16 –
3-6. Adjust Specifications
[PW1 board (Side B)]
3. 3.3 V (D) A Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
CL528
Digital voltmeter
VR502
3.33 ± 0.02 V
VR502
CL532
VR505 VR504 VR503
VR501
CL522
CL520
L5004
(out)
CL528
Note:
1. Voltage adjustment is necessary to repair in the PW1 board and replace the parts.
2. Power voltage set about +3.0 V.
Preparation:
1. Carry out the voltage adjustments disconnecting cabinet back and cabinet front. Disconnect CN981 (CA3), CN302 (SY1) and CN310 (SY1). Connect all other connectors.
2. Shorten pin 1 and pin 3 of CN302 (SY1).
3. Insert the compact flash.
4. Set the main switch to the camera mode.
5. Set the selector dial to the still image shooting mode.
6. Push the power switch, and comfirm that the through screen from the CCD can be seen on the LCD.
1. IC501 Oscillation Frequency Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR501 to 200 ± 1 kHz.
CL532
Frequency counter
VR501
200 ± 1 kHz
2. 5.0 V (D) Voltage Adjustment
Adjustment method:
1.Adjust with VR502 to 3.33 ± 0.02 V
4. 3.4 V (D) B Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR503 to 3.38 ± 0.03 V.
L5004 OUT side
Digital voltmeter
VR503
3.38 ± 0.03 V
5. 5 V (A) Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR505 to 5.13 ± 0.05 V.
[CA3 board (Side A)]
CL572
VR514
CL579
C5133(+)
VR515
CL522
Digital voltmeter
VR505
5.13 ± 0.05 V
CL568
VR921
VR513
VR511
CL589
L1702 (input)
CL407
(CSYNC)
VR512
CL403(R)
TP921
CL402(G)
CL404
(XENB)
CL401(B)
TP922
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
CL520
Digital voltmeter
VR504
5.10 ± 0.05 V
Adjustment method:
1. Adjust with VR504 to 5.10 ± 0.05 V.
Note:
1. Voltage adjustment is necessary to repair in the CA3 board and replace the parts.
2. Power voltage set about +3.0 V.
6. IC511 Oscillation Frequency Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
– 17 –
CL572
Frequency counter
VR511
200 ± 1 kHz