SANYO VPC-J1EX, VPC-J1 BOARD LOCATION

Page 1
2-3. BOARD LOCATION
CA1 board
TB1 board
CP1 board
TB2 board
ST2 board
ST3 board
ST1 board
– 11 –
Page 2

3. ELECTRICAL ADJUSTMENT

3-1. Table for Servicing Tools
1
1
1
1Chroma meter
1
1
Part code
VJ8-0190
VJ8-0202
VJ8-0192
VJ8-0191
VJ8-0188
Ref. No.
J-1
J-2
J-3
Name
Pattern box (color viewer)
Siemens star chart
Calibration software
Number
J-4
J-5
Spare lump
J-6
Discharge jig
Note: J-1 Pattern box (color viewer) is 100 - 110 VAC only.
3-3. Adjustment Items and Order
1. IC501 Oscillation Frequency Adjustment
2. Lens Adjustment
3. AWB Adjustment
4. CCD White Point Defect Detect Adjustment
5. CCD Black Point And White Point Defect Detect Adjust­ment In Lighted
6. LCD Panel Adjustment
6-1. LCD VcomPP Adjustment 6-2. LCD VcomDC Adjustment Note: If the lens, CCD and board in item 2-5, it is necessary
to adjust again.
J-1 J-2
J-3
J-5
J-4
J-6
3-4. Setup
1. System requirements
Windows 98 or Me or 2000 or XP IBM R -compatible PC with pentium processor CD-ROM drive
3.5-inch high-density diskette drive USB port 40 MB RAM Hard disk drive with at least 15 MB available VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation diskette into your diskette drive.
2. Open the explorer.
3. Copy the DscCalDI_130a folder on the floppy disk in the FD drive to a folder on the hard disk.
3. Installing USB driver
Install the USB driver with camera or connection kit for PC.
4. Pattern box (color viewer)
Turn on the switch and wait for 30 minutes for aging to take place before using Color Pure. It is used after adjusting the chroma meter (VJ8-0192) adjust color temperature to 3100 ± 20 K and luminosity to 900 ± 20 cd/m the lump and its circumference are high temperature during use and after power off for a while.
2
. Be careful of handling
3-2. Equipment
2. Digital voltmeter
3. AC adaptor
4. PC (IBM R -compatible PC, Pentium processor, Window 98 or Me or 2000 or XP)
5. Computer screen during adjustment
Calibration
AWB
Focus
UV Matrix
Cal Mode
Cal Data
USB storage
VID
Get
PID
Set
OK
OK
Upload
Firmware
Image
Initialize
EVF
LCD Type
LCD
R Bright
RGB Offset
Tint
VCO
H AFC Test
Serial
Set
– 12 –
Set
Rev.
B Bright
Gain
Phase
Set Set
VCOMDC
VCOMPP
Setting
Language
Video Mode
Page 3
3-5. Connecting the camera to the computer
1. Line up the arrow on the cable connector with the notch on the camera's USB port. Insert the connector.
2. Locate a USB port on your computer.
To USB port
AC adaptor
USB cable
– 13 –
Page 4
3-6. Adjust Specifications
[ST1 board (Side B)]
CL531
VR501
Preparation:
POWER switch: ON
Adjustment condition:
More than A3 size siemens star chart Fluorescent light illumination with no flicker Illumination above the subject should be 400 lux ± 10 %.
Adjustment method:
1. Set the siemens star chart 150 cm ± 3 cm so that it be­comes center of the screen.
2. Double-click on the DscCalDi.exe.
3. Click the Focus, and click the Yes.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
Note:
1. Frequency adjustment is necessary to repair in the ST1 board and replace the parts. It is carried out with play mode.
Preparation:
1. Remove CN931 in the CP1 board, and lift the cabinet front. ST1 board can be seen. (Connect all connectors except CN931.)
2. Insert the SD card.
3. Set the selector dial to playback mode. Comfirm that the playback image can be seen on the LCD.
1. IC501 Oscillation Frequency Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR501 to 497.3 ± 1 kHz.
CL531
Frequency counter
VR501
497.3 ± 1 kHz
2. Lens Adjustment
3. AWB Adjustment
Camera
Pattern box
(color viewer)
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer except the white section. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Camera
Approx.
150 cm 3 cm
Siemens
star chart
4. CCD White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “CCD Defect” on the LCD “Test, and click the “Ye s ”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
– 14 –
Page 5
5. CCD Black Point And White Point Defect Detect Adjustment In Lighted
Camera
6-1. LCD VcomPP Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi.exe.
2. Adjust LCD “VCOMPP” so that the amplitude of the CL404 waveform is 5.45 V ± 0.05 Vp-p.
5.45 V ± 0.05 Vp-p
Pattern box
(color viewer)
Preparation:
POWER switch: ON Setting of pattern box:
Color temperature: 3100 ± 20 (K) Luminance: 900 ± 20 (cd/m
2
)
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Select “CCD Black” on the LCD “Test, and click the Yes ”.
4. After the adjustment is completed, the number of defect will appear.
6. LCD Panel Adjustment
[CP1 board (Side A)]
CL404 waveform
6-2. LCD VcomDC Adjustment
Adjusting method:
1. Adjust LCD “VCOMDC” so that the amplitude of the CL404 waveform is 4.02 V ± 0.05 Vp-p.
4.02 V ± 0.05 Vp-p
GND
CL404 waveform
CL404
(VCOM)
– 15 –
Page 6

4. USB STORAGE INFORMATION REGISTRATION

USB storage data is important for when the camera is con­nected to a computer via a USB connection. If there are any errors in the USB storage data, or if it has not been saved, the USB specification conditions will not be sat­isfied, so always check and save the USB storage data.
Preparation:
POWER switch: ON
Adjustment method:
1. Connect the camera to a computer. (Refer to 3-5. Con­necting the camera to the computer on the page 13.)
2. Double-click on the DscCalDi.exe.
3. Click on the Get button in the USB storage window and check the USB storage data. VID: SANYO PID: VPC-J1 or VPC-J1EX Serial: Rev. : 1.00
4. Check the “Serial” in the above USB storage data. If the displayed value is different from the serial number printed on the base of the camera, enter the number on the base of the camera. Then click the Set button.
5. Next, check VID, PID and Rev. entries in the USB storage data. If any of them are different from the values in 3. above, make the changes and then click the corresponding Set button.
Calibration
AWB
Focus
UV Matrix
Cal Mode
Cal Data
USB storage
VID
Get
PID
Set
OK
OK
Upload
Firmware
Image
Initialize
EVF
LCD Type
LCD
R Bright
RGB Offset
Tint
VCO
H AFC Test
Serial
Set
Set
Rev.
B Bright
Gain
Phase
Set Set
VCOMDC
VCOMPP
Setting
Language
Video Mode
– 16 –