Notice
PRODUCTION CHANGECORRECTION
FILE No.
ADD INFORMATIONSERVICE FLASH
Please add this notice to the Service manual listed below.
Category : Digital Movie
Model Name Reference No. Destination
VPC-C4EX SM5310592 Europe
VPC-C4EXBL SM5310592 Europe
VPC-C4GXOR SM5310592 General
VPC-C4EXS SM5310592 Europe
VPC-C4E SM5310592 U.K.
VPC-C4 SM5310592 U.S.A., Canada, Taiwan
VPC-C4S SM5310592 U.S.A.
VPC-C4GX SM5310592 General
The reason of change.
A : Misprint B : Quality Reliability C : Standardization D : Design
E : Deletion F : Addition G : Multiple Use
[ADD]
Page 19 3-9. Firmware uploading procedure
1. Uploading the firmware should be carried out if the version number (COMPL PWB XX-X) on the replacement circuit board is lower
than the version of the distributed firmware. For XX-X, enter the name of the circuit board containing the firmware.
2. The firmware is distributed by e-mail in self-extracting archive format. Change the extension of the distributed file to .EXE and
save it in your preferred folder.
3. When you double-click the saved file, the firmware (binary file) will be saved in the same folder.
4. The firmware must not be distributed without permission.
Date : Nov.18 2004
1. Overwriting firmware from the SD card
Preparation:
SD card: SD card with firmware rewritten into the root directory
Data: S718Nxxx.BIN (xxx: version)
Overwriting method:
1. Insert the above SD card.
2. Turn on the camera.
3. Set the main switch to PLAY.
4. Press the MENU button. The playback setting screen appears.
5. Choose the OPTION icon.
6. Choose the FORMAT.
7. Press the left key for 2 seconds. FIRMWARE UPDATE will
display.
8. Choose YES.
9. Press the SET button. Update is starting.
Note:
Do not turn off the camera’s power or remove the SD card
while the firmware is being updated.
The power will turn on automatically after the update is complete.
SX718/EX, EX2, EX3, EX4, E, U, U2, GX
126 681 01, 05, 11, 12, 08, 02, 07, 03
SANYO Electric Co., Ltd.
Osaka,Japan
2. Overwriting firmware from the calibration software
Preparation:
PC with overwriting firmware copied to the preferred folder in
the HD.
Data: S718Nxxx.BIN (xxx: version)
Overwriting method:
1. Attach the adaptor to the docking station terminal on the
bottom of the camera. AC adaptor and USB cable can be
connected to the adaptor terminals.
Use the adaptor to connect the camera to a computer.
Choose the CARD READER, and press the SET button.
2. Double-click on the DscCalDi.exe.
3. Click the Firmware.
4. Choose the fimware file to use for overwriting, and click the
Ye s .
5. Update is starting. The message will appear, and choose
OK.
6. After the update is complete, disconnect the USB cable and
turn the camera’s power off.
Note:
Do not turn off the camera’s power while the firmware is being
updated.
Reference No. SM5310592-01