1. SPECIFICATIONS
1-1. Unit Specifications................................................................................................... 1-2
4-Way Air Discharge Semi-Concealed Type ......................................................................................... 1-2
Wall-Mounted Type ............................................................................................................................... 1-13
Ceiling-Mounted Type ........................................................................................................................... 1-16
Concealed-Duct Type ............................................................................................................................ 1-26
1-2. Major Component Specifications ........................................................................... 1-49
(A) Indoor Units ..................................................................................................................................... 1-49
(B) Outdoor Units .................................................................................................................................. 1-67
1-3. Other Component Specifications ........................................................................... 1-69
4-Way Air Discharge Semi-Concealed Type ......................................................................................... 1-69
Wall-Mounted Type ............................................................................................................................... 1-71
Ceiling-Mounted Type ........................................................................................................................... 1-72
Concealed-Duct Type ............................................................................................................................ 1-73
Outdoor Units ........................................................................................................................................ 1-75
1-4. Dimensional Data ..................................................................................................... 1-77
(A) Indoor Units ..................................................................................................................................... 1-77
4-Way Air Discharge Semi-Concealed Type ................................................................................... 1-77
Wall-Mounted Type .......................................................................................................................... 1-80
Ceiling-Mounted Type ...................................................................................................................... 1-81
Concealed-Duct Type ...................................................................................................................... 1-82
(B) Outdoor Units .................................................................................................................................. 1-90
4-Way Air Discharge Semi-Concealed Type SPW-XDR184GH56 (A/B) x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.8 (2.2 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A9.99.59.29.69.39.0
Max–Running amperes**A––––––
Power inputkW6.086.086.085.935.935.93
C.O.PW / W3.293.293.293.783.783.78
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-X185H x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.8 (2.2 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A9.99.59.29.69.39.0
Max–Running amperes**A––––––
Power inputkW6.086.086.085.935.935.93
C.O.PW / W3.293.293.293.783.783.78
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-XDR254GH56 (A/B) x3 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.4 (2.8 x3)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A9.99.49.19.69.39.0
Max–Running amperes**A––––––
Power inputkW6.076.066.065.935.935.93
C.O.PW / W3.293.303.303.783.783.78
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-X255H x3 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.4 (2.8 x3)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A9.99.49.19.69.39.0
Max–Running amperes**A––––––
Power inputkW6.076.066.065.935.935.93
C.O.PW / W3.293.303.303.783.783.78
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-XDR254GH56 (A/B) x4 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h11.2 (2.8 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A12.612.111.712.111.611.2
Max–Running amperes**A––––––
Power inputkW7.787.777.777.437.437.43
C.O.PW / W3.213.223.223.773.773.77
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-X255H x4 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h11.2 (2.8 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A12.612.111.712.111.611.2
Max–Running amperes**A––––––
Power inputkW7.787.777.777.437.437.43
C.O.PW / W3.213.223.223.773.773.77
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-XDR364GH56 (A/B) x2 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h7.8 (3.9 x2)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A9.99.59.29.79.49.0
Max–Running amperes**A––––––
Power inputkW6.086.086.085.965.965.96
C.O.PW / W3.293.293.293.763.763.76
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-X365H x2 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h7.8 (3.9 x2)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A9.99.59.29.79.49.0
Max–Running amperes**A––––––
Power inputkW6.086.086.085.965.965.96
C.O.PW / W3.293.293.293.763.763.76
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-XDR484GH56 (A/B) x2 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h9.2 (4.6 x2)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A12.712.211.812.211.711.3
Max–Running amperes**A––––––
Power inputkW7.817.807.807.507.507.50
C.O.PW / W3.203.213.213.733.733.73
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-X485H x2 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h9.2 (4.6 x2)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A12.712.211.812.211.711.3
Max–Running amperes**A––––––
Power inputkW7.817.807.807.507.507.50
C.O.PW / W3.203.213.213.733.733.73
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4-Way Air Discharge Semi-Concealed Type SPW-XM185H x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h7.6 (1.9 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.810.410.010.310.09.7
Max–Running amperes**A––––––
Power inputkW6.626.636.636.366.366.36
C.O.PW / W3.023.023.023.523.523.52
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 64cm above drain connection (OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 2.5GY 9.0 / 0.5
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Wall-Mounted Type SPW-KR184GH56 (A/B) x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.4 (2.1 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.39.89.510.29.99.5
Max–Running amperes**A––––––
Power inputkW6.366.366.376.336.336.34
C.O.PW / W3.143.143.143.543.543.53
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH1BG
Refrigerant control–
Drain pump (Drain connection)(13A, OD18mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 3.0Y 8.6 / 0.8
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Wall-Mounted Type SPW-KR254GH56 (A/B) x3 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h12.0 (4.0 x3)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.39.99.610.29.99.6
Max–Running amperes**A––––––
Power inputkW6.386.396.406.356.366.37
C.O.PW / W3.133.133.133.533.523.52
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH1BG
Refrigerant control–
Drain pump (Drain connection)(13A, OD18mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 3.0Y 8.6 / 0.8
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Wall-Mounted Type SPW-KR254GH56 (A/B) x4 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h16.0 (4.0 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A13.813.312.812.912.412.0
Max–Running amperes**A––––––
Power inputkW8.568.578.588.018.028.03
C.O.PW / W2.922.922.913.503.493.49
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-SH1BG
Refrigerant control–
Drain pump (Drain connection)(13A, OD18mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
IndoorMunsell 3.0Y 8.6 / 0.8
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Ceiling-Mounted Type SPW-TDR184GH56 (A/B) x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.0 (2.0 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A11.210.710.310.29.99.5
Max–Running amperes**A––––––
Power inputkW6.856.856.856.276.276.27
C.O.PW / W2.922.922.923.573.573.57
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.0 (2.0 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A11.210.710.310.29.99.5
Max–Running amperes**A––––––
Power inputkW6.856.856.856.276.276.27
C.O.PW / W2.922.922.923.573.573.57
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Ceiling-Mounted Type SPW-TDR254GH56 (A/B) x3 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h9.0 (3.0 x3)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A11.210.710.410.29.99.5
Max–Running amperes**A––––––
Power inputkW6.856.856.866.276.276.27
C.O.PW / W2.922.922.923.573.573.57
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h9.0 (3.0 x3)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A11.210.710.410.29.99.5
Max–Running amperes**A––––––
Power inputkW6.856.856.866.276.276.27
C.O.PW / W2.922.922.923.573.573.57
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Ceiling-Mounted Type SPW-TDR254GH56 (A/B) x4 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h12.0 (3.0 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.714.113.712.912.411.9
Max–Running amperes**A––––––
Power inputkW9.059.059.057.937.937.94
C.O.PW / W2.762.762.763.533.533.53
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h12.0 (3.0 x4)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.714.113.712.912.411.9
Max–Running amperes**A––––––
Power inputkW9.059.059.057.937.937.94
C.O.PW / W2.762.762.763.533.533.53
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Ceiling-Mounted Type SPW-TDR364GH56 (A/B) x2 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h7.8 (3.9 x2)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A11.210.710.410.29.99.6
Max–Running amperes**A––––––
Power inputkW6.876.876.876.296.296.29
C.O.PW / W2.912.912.913.563.563.56
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
Compressor Rotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h7.8 (3.9 x2)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A11.210.710.410.29.99.6
Max–Running amperes**A––––––
Power inputkW6.876.876.876.296.296.29
C.O.PW / W2.912.912.913.563.563.56
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
Compressor Rotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Ceiling-Mounted Type SPW-TDR484GH56 (A/B) x2 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h11.2 (5.6 x2)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.714.113.612.912.311.9
Max–Running amperes**A––––––
Power inputkW9.049.059.057.937.937.94
C.O.PW / W2.772.762.763.533.533.53
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h11.2 (5.6 x2)–
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.714.113.612.912.311.9
Max–Running amperes**A––––––
Power inputkW9.049.059.057.937.937.94
C.O.PW / W2.772.762.763.533.533.53
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)Automatic (Remote control)
Air filterWashable, easy access, long life (2,500 hr)
Remote controller (Option)Wired: RCS-TM80BG /
Refrigerant control–
Drain pump (Drain connection)(20A, OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
IndoorMunsell 10Y 9.3 / 0.4
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Concealed-Duct Type SPW-UR184GH56 (A/B) x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h12.0 (3.0 x4)–
External static pressure (High)Pa (mmAg)40 (4.1): at shipment, 62 (6.3): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.510.19.810.310.09.7
Max–Running amperes**A––––––
Power inputkW6.526.546.576.446.476.50
C.O.PW / W3.073.063.043.483.463.45
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A30 / 28 / 25, (33 / 30 / 28: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.250 (8.8)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-26
1
Page 32
Simultaneous(Double Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U185H x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h12.0 (3.0 x4)–
External static pressure (High)Pa (mmAg)40 (4.1): at shipment, 62 (6.3): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.510.19.810.310.09.7
Max–Running amperes**A––––––
Power inputkW6.526.546.576.446.476.50
C.O.PW / W3.073.063.043.483.463.45
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A30 / 28 / 25, (33 / 30 / 28: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.250 (8.8)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-27
1
1
Page 33
1
Simultaneous(Double Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-UR184SH56B x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h12.0 (3.0 x4)–
External static pressure (High)Pa (mmAg)40 (4.1): at shipment, 62 (6.3): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.510.19.810.310.09.7
Max–Running amperes**A––––––
Power inputkW6.526.546.576.446.476.50
C.O.PW / W3.073.063.043.483.463.45
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A30 / 28 / 25, (33 / 30 / 28: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.247 (8.9)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-28
1
Page 34
Simultaneous(Double Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U185SHT x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h12.0 (3.0 x4)–
External static pressure (High)Pa (mmAg)40 (4.1): at shipment, 62 (6.3): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.510.19.810.310.09.7
Max–Running amperes**A––––––
Power inputkW6.526.546.576.446.476.50
C.O.PW / W3.073.063.043.483.463.45
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A30 / 28 / 25, (33 / 30 / 28: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.247 (8.9)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-29
1
1
Page 35
1
Simultaneous(Triple)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-UR254GH56 (A/B) x3 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h10.5 (3.5 x3)–
External static pressure (High)Pa (mmAg)50 (5.1): at shipment, 92 (9.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.710.310.110.610.310.0
Max–Running amperes**A––––––
Power inputkW6.686.726.776.616.666.70
C.O.PW / W2.992.982.953.393.363.34
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A34 / 30 / 27, (38 / 34 / 30: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.334 (11.8)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-30
1
Page 36
Simultaneous(Triple)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U255H x3 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h10.5 (3.5 x3)–
External static pressure (High)Pa (mmAg)50 (5.1): at shipment, 92 (9.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.710.310.110.610.310.0
Max–Running amperes**A––––––
Power inputkW6.686.726.776.616.666.70
C.O.PW / W2.992.982.953.393.363.34
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A34 / 30 / 27, (38 / 34 / 30: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.334 (11.8)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-31
1
1
Page 37
1
Simultaneous(Triple)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-UR254SH56B x3 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h10.5 (3.5 x3)–
External static pressure (High)Pa (mmAg)50 (5.1): at shipment, 92 (9.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.710.310.110.610.310.0
Max–Running amperes**A––––––
Power inputkW6.686.726.776.616.666.70
C.O.PW / W2.992.982.953.393.363.34
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A34 / 30 / 27, (38 / 34 / 30: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.322 (11.6)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-32
1
Page 38
Simultaneous(Triple)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U255SHT x3 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h10.5 (3.5 x3)–
External static pressure (High)Pa (mmAg)50 (5.1): at shipment, 92 (9.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.710.310.110.610.310.0
Max–Running amperes**A––––––
Power inputkW6.686.726.776.616.666.70
C.O.PW / W2.992.982.953.393.363.34
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A34 / 30 / 27, (38 / 34 / 30: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.322 (11.6)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-33
1
1
Page 39
1
Simultaneous(Double Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-UR254GH56 (A/B) x4 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h14.0 (3.5 x4)–
External static pressure (High)Pa (mmAg)50 (5.1): at shipment, 92 (9.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.413.913.513.513.012.6
Max–Running amperes**A––––––
Power inputkW8.979.039.098.418.478.53
C.O.PW / W2.792.772.753.333.313.28
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A34 / 30 / 27, (38 / 34 / 30: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.334 (11.8)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-34
1
Page 40
Simultaneous(Double Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U255H x4 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h14.0 (3.5 x4)–
External static pressure (High)Pa (mmAg)50 (5.1): at shipment, 92 (9.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.413.913.513.513.012.6
Max–Running amperes**A––––––
Power inputkW8.979.039.098.418.478.53
C.O.PW / W2.792.772.753.333.313.28
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A34 / 30 / 27, (38 / 34 / 30: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.334 (11.8)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-35
1
1
Page 41
1
Simultaneous(Double Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-UR254SH56B x4 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h14.0 (3.5 x4)–
External static pressure (High)Pa (mmAg)50 (5.1): at shipment, 92 (9.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.413.913.513.513.012.6
Max–Running amperes**A––––––
Power inputkW8.979.039.098.418.478.53
C.O.PW / W2.792.772.753.333.313.28
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A34 / 30 / 27, (38 / 34 / 30: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.322 (11.6)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-36
1
Page 42
Simultaneous(Double Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U255SHT x4 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h14.0 (3.5 x4)–
External static pressure (High)Pa (mmAg)50 (5.1): at shipment, 92 (9.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.413.913.513.513.012.6
Max–Running amperes**A––––––
Power inputkW8.979.039.098.418.478.53
C.O.PW / W2.792.772.753.333.313.28
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A34 / 30 / 27, (38 / 34 / 30: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.322 (11.6)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-37
1
1
Page 43
1
Simultaneous(Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-UR364GH56 (A/B) x2 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.4 (4.2 x2)–
External static pressure (High)Pa (mmAg)79 (8.1): at shipment, 122 (12.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.910.510.210.810.410.1
Max–Running amperes**A––––––
Power inputkW6.766.796.826.716.746.77
C.O.PW / W2.962.952.933.343.323.31
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A38 / 33 / 31, (42 / 38 / 33: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.468 (16.5)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-38
1
Page 44
Simultaneous(Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U365H x2 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.4 (4.2 x2)–
External static pressure (High)Pa (mmAg)79 (8.1): at shipment, 122 (12.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.910.510.210.810.410.1
Max–Running amperes**A––––––
Power inputkW6.766.796.826.716.746.77
C.O.PW / W2.962.952.933.343.323.31
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A38 / 33 / 31, (42 / 38 / 33: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.468 (16.5)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-39
1
1
Page 45
1
Simultaneous(Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-UR364SH56B x2 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.4 (4.2 x2)–
External static pressure (High)Pa (mmAg)79 (8.1): at shipment, 122 (12.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.910.510.210.810.410.1
Max–Running amperes**A––––––
Power inputkW6.766.796.826.716.746.77
C.O.PW / W2.962.952.933.343.323.31
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A38 / 33 / 31, (42 / 38 / 33: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.451 (16.2)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-40
1
Page 46
Simultaneous(Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U365SHT x2 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h8.4 (4.2 x2)–
External static pressure (High)Pa (mmAg)79 (8.1): at shipment, 122 (12.4): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A10.910.510.210.810.410.1
Max–Running amperes**A––––––
Power inputkW6.766.796.826.716.746.77
C.O.PW / W2.962.952.933.343.323.31
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A38 / 33 / 31, (42 / 38 / 33: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.451 (16.2)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-41
1
1
Page 47
1
Simultaneous(Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-UR484GH56 (A/B) x2 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h13.2 (6.6 x2)–
External static pressure (High)Pa (mmAg)78 (8.0): at shipment, 113 (11.5): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.313.713.313.412.912.4
Max–Running amperes**A––––––
Power inputkW8.878.908.938.338.378.40
C.O.PW / W2.822.812.803.363.353.33
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A40 / 37 / 33, (44 / 40 / 37: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.468 (16.5)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-42
1
Page 48
Simultaneous(Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U485H x2 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h13.2 (6.6 x2)–
External static pressure (High)Pa (mmAg)78 (8.0): at shipment, 113 (11.5): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.313.713.313.412.912.4
Max–Running amperes**A––––––
Power inputkW8.878.908.938.338.378.40
C.O.PW / W2.822.812.803.363.353.33
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A40 / 37 / 33, (44 / 40 / 37: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.468 (16.5)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-43
1
1
Page 49
1
Simultaneous(Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-UR484SH56B x2 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h13.2 (6.6 x2)–
External static pressure (High)Pa (mmAg)78 (8.0): at shipment, 113 (11.5): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.313.713.313.412.912.4
Max–Running amperes**A––––––
Power inputkW8.878.908.938.338.378.40
C.O.PW / W2.822.812.803.363.353.33
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A40 / 37 / 33, (44 / 40 / 37: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.451 (16.2)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-44
1
Page 50
Simultaneous(Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-U485SHT x2 / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h13.2 (6.6 x2)–
External static pressure (High)Pa (mmAg)78 (8.0): at shipment, 113 (11.5): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A14.313.713.313.412.912.4
Max–Running amperes**A––––––
Power inputkW8.878.908.938.338.378.40
C.O.PW / W2.822.812.803.363.353.33
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (25A, OD32mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A40 / 37 / 33, (44 / 40 / 37: using the booster cable)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.451 (16.2)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-45
1
1
Page 51
1
Simultaneous(Double Twin)-Type
1-1. Unit Specifi cations
Concealed-Duct Type SPW-US185H x4 / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h7.2 (1.8 x4)–
External static pressure (High)Pa (mmAg)15 (1.5): at shipment, 40 (4.1): Using short circuit connection
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A11.711.210.911.010.710.3
Max–Running amperes**A––––––
Power inputkW7.157.157.156.766.766.76
C.O.PW / W2.802.802.803.313.313.31
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)Max.head 50cm above drain connection (OD26mm)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 5.3
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
dB-A35 / 33 / 31, (37 / 35 / 33: Using short circuit connection)
Indoor unitOutdoor unit
m (ft.)
3
(cu.ft)0.169 (5.97)0.757 (26.7)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Indoor unitOutdoor unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-46
1
Page 52
Single-Type
1-1. Unit Specifi cations
Concealed-Duct High Static Pressure Type SPW-D705H / SPW-C706VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h11.1–
External static pressure (High)Pa (mmAg)176 (18)
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A11.411.010.710.410.19.8
Max–Running amperes**A––––––
Power inputkW7.097.127.156.476.506.53
C.O.PW / W2.822.812.803.463.453.43
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)25A Male screw (No Drain Pump)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5757
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Concealed-Duct High Static Pressure Type SPW-D905H / SPW-C906VH8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)m
Moisture removal (High)Liters / h13.9–
External static pressure (High)Pa (mmAg)216 (22): at shipment 235 (24): using the booster cable
ELECTRICAL RATINGS
Voltage ratingsV380400415380400415
Available voltage rangeV342~456(outdoor) 198~264(indoor)
Running amperes*A15.314.814.313.112.612.3
Max–Running amperes**A––––––
Power inputkW9.499.559.618.148.208.26
C.O.PW / W2.632.622.603.443.413.39
Max.Starting amperesA––––––
FEATURES
Controls / Thermostat controlMicroprocessor / I.C.thermostat
TimerON / OFF 72-hours
Fan speeds Indoor / Outdoor3 and Automatic control / Variable
Airflow direction (Indoor)–
Air filterField supply
Remote controller (Option)Wired: RCS-TM80BG / Wireless: RCS-BH80BG.WL
Refrigerant control–
Drain pump (Drain connection)25A Male screw (No Drain Pump)
CompressorRotary (SANYO)
Operation sound
Color
(Approximate value)
Indoor - Hi / Me / Lo
Outdoor - HidB-A5758
Indoor–
OutdoorMunsell 1Y 8.5 / 0.5
REFRIGERANT TUBING
Limit of tubing lengthm (ft.)100 (328)
Limit of tubing length at shipmentm (ft.)5~30(16~98)
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipmentkg–R410A - 6.5
Liquid tubemm (in.)12.7 (1 / 2)12.7 (1 / 2)
Gas tubemm (in.)25.4 (1)25.4 (1)*
DIMENSIONS & WEIGHT
Heightmm (in.)467 (18-12 / 32)1526 (60-5 / 64)
Unit dimensions
*1 There are two types of supplied tubings. The one tubing port ø19.05 (fl are process) is connected to the fl ared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
Sol-control-valveUKV-25D18
Magnetic coilUKV-U030E, DC 12 V
4 way valve
4 way valveSTF-0712G
Electro magnetic coilSTF-01AI518A1, AC 220-240 V, 50Hz / 60Hz
1-76
Page 82
1-4. Dimensional Data
(A) Indoor Units: 4-Way Air Discharge Semi-Concealed (X) Type
1
18, 25 Types
97
88
Ceiling opening dimensions
Suspension bolt pitch
Ceiling opening
dimensions
X
Suspension bolt pitch
790
860 – 910
120
88
860 – 910
723
Center of
panel
480
400
30
160
15
73
X View
80160
7
8
35
256
bolts should be selected so that
there is a gap of 30 mm or
more below the lower surface of
the ceiling (15 mm or more
below the lower surface of the
main unit), as shown in the
figure at right. If the suspension
bolt is too long, it will contact
the ceiling panel and the unit
60
113
45
* The length of the suspension
950
514
cannot be installed.
2
70
6
4
250
514
950
7
347
840
30
Suspension bolt hole (4-12 × 37 hole)
Fresh air intake duct connection port (ø100)
9
10
53
97
Less than 35
Less than 35
188
840
120
210
480
10
382
9
Air intake
Discharge outlet
Refrigerant tubing (liquid tube) 18 type ø6.35 (flared), 25 type ø9.52 (flared)
Refrigerant tubing (gas tube) 18 type ø12.7 (flared), 25 type ø15.88 (flared)
Drain tube connection port VP25 (outer dia. ø32)
Power supply port
Discharge duct connection port (ø150)
Vaporization-type humidifier (optional) installation point
12345
678
160
2
2
1
2
8
1-77
Page 83
1
1-4. Dimensional Data
(A) Indoor Units: 4-Way Air Discharge Semi-Concealed (X) Type
36, 48 Types
Ceiling opening
dimensions
X
Suspension bolt pitch
790
860 – 910
30
183
97
88
480
X view
80160
160
15
73
7
8
88
723
Ceiling opening dimensions
860 – 910
Suspension bolt pitch
(400)
319
60
35
* The length of the suspension
bolts should be selected so that
there is a gap of 30 mm or
more below the lower surface of
the ceiling (15 mm or more
below the lower surface of the
main unit), as shown in the
figure at right. If the suspension
bolt is too long, it will contact
the ceiling panel and the unit
113
45
950
514
cannot be installed.
2
6
Center
of panel
347
840
25070
514
950
30
7
9
Air intake
Discharge outlet
Refrigerant tubing (liquid tube) ø9.52 (flared)
Refrigerant tubing (gas tube) ø15.88 (flared)
Drain tube connection port VP25 (outer dia. ø32)
Power supply port
Discharge duct connection port (ø150)
Vaporization-type humidifier (optional) installation point
123456789
382
Suspension bolt hole (4-12 × 37 hole)
Fresh air intake duct connection port (ø100)
10
840
53 4
183
210
480
160
97
Less than 35
2
2
1
2
8
10
Less than 35
188
1-78
Page 84
1-4. Dimensional Data
(A) Indoor Units: 4-Way Air Discharge Semi-Concealed (XM) Type
18 Type
195
8
125
A View
1
30
17
79
AA
600
534
Suspension bolt pitch
Ceiling opening dimensions
600
534
Center of
panel
7
Ceiling opening dimensions
Suspension bolts pitch
316
327
5
170
575
160
53
283
215
The length of the suspension
bolts should be selected so that
there is a gap of 30 mm or
the ceiling (17 mm or more
below the lower surface of the
main unit), as shown in the
figure at right. If the suspension
bolts is too long, it will contact
the ceiling panel and the unit
cannot be installed.
30
2
625
358
3
6
45
117 45
2
625
334
2
1
2
Air intake
Discharge outlet
Refrigerant tubing (liquid tube) 18 type o6.35 (flared)
Refrigerant tubing (gas tube) 18 type o12.7 (flared)
1234567
575
Drain tube connection port VP20 (outer dia. o26)
Power supply port
Suspension bolt hole (4-12 x 30 hole)
Fresh air intake duct connection port (ø100)
8
92
1-79
Less than 25Less than 25
Page 85
1
1-4. Dimensional Data
(A) Indoor Units: Wall-Mounted Type
18 Type
7, 9, 12, 18 type
285
ø80
Gas tube ø12.7 (length: Approx. 400 mm)
LIquid tube ø6.35 (length: Approx. 470 mm)
995
Drain and wiring port (ø9.52)
Drain hose VP13 (length: Approx. 450 mm)
25 Type
25 type
330
ø80
Drain hose VP13 (length: Approx. 450 mm)
Gas tube ø15.88 (length: Approx. 500 mm)
1,140
Drain and wiring port (ø9.52)
Liquid tube ø9.52 (length: Approx. 570 mm)
1-80
Page 86
1-4. Dimensional Data
(A) Indoor Units: Ceiling-Mounted Type
1
Length
Type
18
25
36, 48
25184146161
Closed with rubber stopper at time of shipment.
ABC
855
1125
1540
Left side
910
1180
1595
171
39
210
210
210
Unit: mm
Rear (Figure shows view from front)
Left drain positionRight drain position
170
320
(Suspension bolt pitch)
27.527.5
(Suspension bolt pitch)
Liquid
tubing
Gas tubing
B
Ceiling side
A
7597216
105
680
171
39
C
Right side
Air intake
Air
(Liquid tubing •
Gas tubing)
251
1-81
Page 87
1
1-4. Dimensional Data
(A) Indoor Unit: Concealed-Duct (U) Type
18 Type
SPW-UR184GH56 (A/B), U185H
10
25
175
190
35
11
260
(Air outlet
duct flange)
310
25210
10
25
24
(Hole)
19
662 (Air outlet duct flange)
12-ø3.3
3131
200
3 = 600
×
200 P
160
630
(450 × 450)
Inspection access
7030
(Field supply)
285
70130
25
85
115
65
40700
75
(150)
290262
780 (Suspension bolt pitch)
90
(Suspension bolt pitch)
185
580
1-82
25
Refrigerant liquid line ø6.35 (liquid tube)
Refrigerant gas line ø12.7
Upper drain port (O.D. 32 mm)
Bottom drain port (O.D. 32 mm)
Suspension lug
Power supply outlet (2-ø30)
Fresh air intake port (ø150)
Flange for the flexible air outlet duct (ø200)
9
Tube cover
10
Electrical component box
11
Flange for the air intake duct
(Option or field supply)
Page 88
1-4. Dimensional Data
(A) Indoor Unit: Concealed-Duct (U) Type
SPW-UR254GH56 (A/B), U255H
Indoor unit: 25 Type
10
25
175
1
190
35
11
260
(Air outlet
duct flange)
40
1000
70130
(150)
285
115
65
310
25210
10
25
24
(Hole)
19
16-ø3.3
3131
180
900
160
630
(450 × 450)
(Field supply)
Inspection access
25
7030
85
962 (Air outlet duct flange)
(Suspension bolt pitch)
185
90
580
1-83
29029027275
1080 (Suspension bolt pitch)
25
Refrigerant liquid line ø9.52 (liquid tube)
(Use the tube connector)
Refrigerant gas line ø15.88 (gas tube)
Upper drain port (O.D. 32 mm)
Bottom drain port (O.D. 32 mm)
Suspension lug
Power supply outlet (2-ø30)
Fresh air intake port (ø150)
Flange for the flexible air outlet duct (ø200)
9
Tube cover
10
Electrical component box
11
Flange for the air intake duct
(Option or field supply)
Refrigerant liquid line ø9.52 (liquid tube)
Refrigerant gas line ø15.88 (gas tube)
Upper drain port (O.D. 32 mm)
Bottom drain port (O.D. 32 mm)
Suspension lug
Power supply outlet (2-ø30)
Fresh air intake port (ø150)
Flange for the flexible air outlet duct (ø200)
9
Tube cover
10
Electrical component box
11
Flange for the air intake duct
(Option or field supply)
flared connection (o19.05)
Refrigerant tubing port
4
Electrical wiring port (o16)
5
6
Electrical wiring port (o19)
Electrical wiring port (o29)
7
Electrical wiring port (o38)
8
NameFigureQ’ty
Reducing Joint Tube
(o19.05 o25.4)
Joint Tube (o19.05)
Remark:
There are two types of supplied tubings.
The one tubing port o19.05 (flare process) is
connected to the flared connection of the gas
port side's service valve. The other "L" shaped
tubing port is brazed in connection after cutting
the tube at the proper length. Then make a
brazing connection to the main tubing (o25.4).
340
1
1
Anchor bolt
R30
5
6
8
Anchor bolt
6149
VIEW A
2
22
3077
42
49
7
8
60
57
8
4
Air
3
discharge
39
586
111
111
Anchor bolt
Air intake
1526
5
6
22
30
42
49
77
60
85 64
7
8
25
4
A
33
7
58
63 80
Anchor bolt
5.562 49
VIEW B
Refrigerant tubing connection portBottom removable connection port
677.5
46
65
121
5
52
60
4
3
43
6
8
59
7
Anchor bolt
1-90
Page 96
1-4. Dimensional Data
(B) Outdoor Unit: SPW-C906VH8
410
10
380
20
170660110
26
Air
290
intake
Air
intake
10521975 75
Air discharge
940
2 x o32 holes (holes for drain)
Of the 4 o32 holes , use 1 of the 2 holes specified
for drain use to install the port.
Use rubber plugs to seal the remaining 3 holes.
flared connection (o19.05)
Refrigerant tubing port
4
Electrical wiring port (o16)
5
6
Electrical wiring port (o19)
Electrical wiring port (o29)
7
Electrical wiring port (o38)
8
NameFigureQ’ty
Reducing Joint Tube
(o19.05 o25.4)
Joint Tube (o19.05)
Remark:
There are two types of supplied tubings.
The one tubing port o19.05 (flare process) is
connected to the flared connection of the gas
port side's service valve. The other "L" shaped
tubing port is brazed in connection after cutting
the tube at the proper length. Then make a
brazing connection to the main tubing (o25.4).
340
1
1
1
Anchor bolt
R30
5
6
8
Anchor bolt
6149
VIEW A
2
22
30
42
49
7
8
8
77
60
57
4
Air
3
discharge
39
586
111
111
Anchor bolt
Air intake
1526
5
6
22
30
42
49
77
85 64
7
8
25
4
60
A
33
7
58
63 80
Anchor bolt
5.5
Refrigerant tubing connection portBottom removable connection port
Freeze-prevention coil
(Attached to the heat exchanger)
1-6. Operating Range
TemperatureIndoor air intake temp.Outdoor air intake temp.
Cooling
Heating
Maximum
Minimum
Maximum
Minimum
Solenoid
valve
Strainer
Gas line
service valve
4-way valve
Solenoid
valve
M
M
Strainer
(3/4")
Liquid line
service valve
ø25.4 (brazing)
ø12.7
32°C DB / 23°C WB 43°C DB
18°C DB / 14°C WB–15°C DB
30°C DB / – WB15°C WB
–20°C WB–
Heat
exchanger
Distributor
Strainer
1-92
Page 98
1-7. Capacity Correction Graph According to Temperature Condition
SPW-C706 / 906VH8
Max. Capacity & Input Change Characteristics When the Outdoor Air Temperature Changes :
Cooling capacity ratio (maximum capacity)Heating capacity ratio (maximum capacity)
1
140
120
100
80
60
40
Capacity coefficient (%)Input coefficient (%)
140
120
100
80
60
Indoor air intake temp (WB)
120
22WB
19WB
16WB
Indoor air intake temp (WB)
22WB
19WB
16WB
-5-105010-5
3525155-1545
100
80
60
40
Capacity coefficient (%)Input coefficient (%)
120
100
80
60
40
Indoor air intake temp (°C DB)
Indoor air intake temp (°C DB)
-1515-20
16
20
24
24
20
16
Outdoor air intake temp (°C DB) Outdoor air intake temp (°C WB)
NOTE:
1. The characteristics of this table shows the values under the following condition.
Piping equivalent length7.5m
High & low difference0m
Airflow rateHigh
2. The circle mark " " shows the maximum efficiency and maximum power consumption under the standard condition.
* The maximum efficiency shows the maximum value in the parenthesis of the specifications
(cooling and heating capacity).
3. The heating capacity of this table excludes the capacity failure under the condensation (including the defrosting drive).
For 50 Hz and 60 HzFor 50 Hz and 60 Hz
Outdoor unit heating capacity correction coefficient during of frosting/defrosting
To calculate the heating capacity with consideration for frosting/defrosting operation, multiply the heating
capacity found from the capacity graph by the correction coefficient from the table above.
1-93
1.00.950.91 0.92
Page 99
1
1-8. Noise Criterion Curves
(A) Indoor Units
4-Way Air Discharge Semi-Concealed Type
MODEL:
SOUND LEVEL :31 dB(A)
CONDITION:
60
50
40
30
Approximate
minimum audible
20
(0dB = 0.0002µbar)
limit for
Sound pressure level (dB)
continuous noise
10
Overall
Frequency at center of sound pressure band (Hz)
MODEL:
SOUND LEVEL :39 dB(A)
CONDITION:
60
SPW-XDR184GH56 (A/B)
SPW-X185H
STRONG
MEDIUM
WEAK
1.5 m directly below unit
SPW-XDR364GH56 (A/B)
SPW-X365H
29 dB(A)
27 dB(A)
400063125 250800020001000500
STRONG
MEDIUM
WEAK
1.5 m directly below unit
36 dB(A)
33 dB(A)
NC-50
NC-40
NC-30
NC-20
Both 50Hz / 60Hz
MODEL:
SOUND LEVEL :34 dB(A)
CONDITION:
60
50
40
30
Approximate
minimum audible
20
(0dB = 0.0002µbar)
limit for
Sound pressure level (dB)
continuous noise
10
Overall
Frequency at center of sound pressure band (Hz)
MODEL:
SOUND LEVEL :42 dB(A)
CONDITION:
60
SPW-XDR254GH56 (A/B)
SPW-X255H
STRONG
MEDIUM
WEAK
1.5 m directly below unit
SPW-XDR484GH56 (A/B)
SPW-X485H
31 dB(A)
28 dB(A)
STRONG
MEDIUM
WEAK
1.5 m directly below unit
38 dB(A)
34 dB(A)
Strong
Weak
NC-50
NC-40
NC-30
NC-20
400063125 250800020001000500
50
40
30
Approximate
minimum audible
20
(0dB = 0.0002µbar)
limit for
Sound pressure level (dB)
continuous noise
10
Overall
Frequency at center of sound pressure band (Hz)
400063125 250800020001000500
NC-50
NC-40
NC-30
NC-20
50
40
30
Approximate
minimum audible
20
(0dB = 0.0002µbar)
limit for
Sound pressure level (dB)
continuous noise
10
Overall
Frequency at center of sound pressure band (Hz)
NC-50
NC-40
NC-30
NC-20
400063125 250800020001000500
1-94
Page 100
1-8. Noise Criterion Curves
1
(A) Indoor Units
4-Way Air Discharge Semi-Concealed Type
MODEL
SOUND LEVEL41
CONDITION
60
50
40
30
Approximate
minimum audible
20
(0dB = 0.0002µbar)
limit for
Sound pressure level (dB)
continuous noise
10
Overall
Frequency at center of sound pressure band (Hz)
:
SPW-XM185H
:
STRONG
WEAK33
1.5 m directly below unit
:
dB(A)
dB(A)
NC-50
NC-40
NC-30
NC-20
400063125 250800020001000500
Both 50Hz / 60Hz
Strong
Weak
1-95
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.