Ordering number : ENN5595A
27.0 27.08.0
ø6.0
1
2
Cathode mark
ø1.3
SB20-04A
Schottky Barrier Diode
SB20-04A
40V, 2.0A Rectifier
Applications
•
High frequency rectification (switching regulators,
converters, choppers).
Package Dimensions
unit : mm
1176
[SB20-04A]
Features
•
Low forward voltage (VF max=0.55V).
•
Fast reverse recovery time.
•
Average rectified current (IO=2.0A).
Specifications
Absolute Maximum Ratings at T a=25°C
Parameter Symbol Conditions Ratings Unit
Repetitive Peak Reverse Voltage V
Average Rectified Current I
Surge Forward Current I
Junction T emperature Tj 125 °C
Storage T emperature T stg --40 to +125 °C
RRM
O
FSM
50Hz sine wave, 1 cycle 100 A
--40 V
2.0 A
Electrical Characteristics at T a=25°C
Parameter Symbol Conditions
Forward Voltage V
Reverse Current I
Interterminal Capacitance C VR=10V, f=1MHz 125 pF
Thermal Resistance (Junction-Ambient) Rth(j-a) Printed circuit board 100 °C / W
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft's
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
R
IF=2.0A 0.55 V
F
VR=--40V --0.5 mA
min typ max
Ratings
SANYO Electric Co.,Ltd. Semiconductor Company
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
31901 GI IM
No.5595A-1/3
Unit

10
7
5
3
-- A
2
F
1.0
7
5
Forward Current, I
3
2
0.1
0 0.2 0.4 0.6 0.8 1.0
IF -- V
°C
125
Ta=
Forward Voltage, V
1.5
-- W
F
1.0
P
25°C
F
-- I
180°C
F
O
F
240°C
-- V
120°C
60°C
DC
SB20-04A
IT03016
I
-- V
R
Ta=
125
100
75°C
50°C
R
°C
°C
-- n
R
-- V
IT03017
50Hz
5
3
2
--10
7
5
-- mA
3
R
2
--1.0
7
5
3
2
--0.1
Reverse Current, I
7
5
3
2
0 10203040
Reverse Voltage, V
I
100
FSM
Ta=25°C
-- A
FSM
50
0.5
θ
O
-- A
360°
IT03018
Average Forward Power Dissipation, P
0
0 0.5 1.0 1.5 2.5 3.0 3.52.0
Average Rectified Current, I
0.4
-- W
R
0.3
θ
360°
V
R
P
-- V
R
R
DC
300°C
0.2
240°C
180°C
0.1
Average Reverse Power Dissipation, P
0
0 10203040
4.0
-- A
3.0
DC
O
Reverse Voltage, V
I
-- Ta
O
R
-- V
IT03020
θ
360°
Surge Forward Current, I
0
1.0 10
23 57
Number of Cycles at 50Hz, n
1000
7
5
-- pF
3
2
100
7
5
Interterminal Capacitance, C
3
2
--1.0 --10
23 57
Reverse Voltage, V
C -- V
23 57
R
23 57
-- V
R
100
IT03019
f=1MHz
Ta=25°C
--100
IT03021
240°C
2.0
180°C
Sine wave
120°C
60°C
1.0
Average Rectified Current, I
0
0 20 40 60 80 100 120 140
Ambient Temperature, Ta -- °C
IT03022
No.5595A-2/3

SB20-04A
Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer's
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customer's products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products(including technical data,services) described or
contained herein are controlled under any of applicable local export control laws and regulations,
such products must not be exported without obtaining the export license from the authorities
concerned in accordance with the above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co. , Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification"
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only ; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.
This catalog provides information as of March, 2001. Specifications and information herein are subject
to change without notice.
No.5595A-3/3
PS