Sanyo SAP–K181GJA, SAP–K241GJA, SAP–K181MBA, SAP–C161GA, SAP–K241MBA Technical & Service Manual

...
TECHNICAL & SERVICE MANUAL
SAP–K161GJA + SAP–C161GA
+ SAP–C161JA
SAP–K181GJA + SAP–C181GA
+ SAP–C181JA
SAP–K181MBA + SAP–C181MA
+ SAP–C181BA
SAP–K241GJA + SAP–C241GA
+ SAP–C241JA
SAP–K241MBA + SAP–C241MA
+ SAP–C241BA
FILE NO.
REFERENCE NO. SM700456
Outdoor Unit
SPLIT SYSTEM AIR CONDITIONER
SAP–K161GJA SAP–K181GJA
SAP–K181MBA SAP–K241GJA
SAP–K241MBA
SAP–C161GA SAP–C161JA
SAP–C181GA SAP–C181JA SAP–C181MA SAP–C181BA
SAP–C241GA SAP–C241JA SAP–C241MA SAP–C241BA
Indoor Model No. Product Code No. Destination SAP–K161GJA–S 1 852 070 38 General (50/60Hz) SAP–K181GJA–S 1 852 070 39 SAP–K181MBA–S 1 852 070 40
SAP–K241GJA–S 1 852 070 42 General (50/60Hz)
SAP–K241MBA–S 1 852 070 43
Middle East (50/60Hz)
Middle East (50/60Hz)
Outdoor Model No. Product Code No. Destination
SAP–C161GA–S 1 852 070 55 General (50Hz)
SAP–C161JA–S 1 852 070 56 General (60Hz)
SAP–C181GA–S 1 852 070 57 General (50Hz)
SAP–C181JA–S 1 852 069 62 General (60Hz) SAP–C181MA–S 1 852 070 58 Middle East (50Hz) SAP–C181BA–S 1 852 070 60 Middle East (60Hz) SAP–C241GA–S 1 852 070 61 General (50Hz)
SAP–C241JA–S 1 852 070 62 General (60Hz) SAP–C241MA–S 1 852 070 63 Middle East (50Hz) SAP–C241BA–S 1 852 070 65 Middle East (60Hz)
General (50/60Hz)
i
Important! Please Read Before Starting
This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.
For safe installation and trouble-free operation, you must:
Carefully read this instruction booklet before beginning.
Follow each installation or repair step exactly as shown.
Observe all local, state, and national electrical codes.
Pay close attention to all warning and caution notices
given in this manual.
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
If Necessary, Get Help
These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.
Special Precautions
When Wiring
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.
• Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.
• Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.
• Ground the unit following local electrical codes.
• Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
WARNING
CAUTION
WARNING
When Transporting
Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.
When Installing…
…In a Ceiling or Wall
Make sure the ceiling/wall is strong enough to hold the units weight. It may be necessary to construct a strong wood or metal frame to provide added support.
…In a Room
Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.
…In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.
…In an Area with High Winds
Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.
…In a Snowy Area (for Heat Pump-type Systems)
Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.
When Connecting Refrigerant Tubing
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak­free connection.
• Check carefully for leaks before starting the test run.
When Servicing
• Turn the power off at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.
• Keep your fingers and clothing away from any moving parts.
• Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.
Others
• Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas.
• Confirm upon completing installation that no refrigerant gas is leaking. If escaped gas comes in contact with a stove, gas water heater, electric room heater or other heat source, it can produce dangerously toxic gas.
CAUTION
Table of Contents
Page
1. OPERATING RANGE .............................................................................................................................. 1
2. SPECIFICATIONS
2-1. Unit Specifications.......................................................................................................................... 2
2-2. Major Component Specifications.................................................................................................... 8
2-3. Other Component Specifications.................................................................................................... 17
3. DIMENSIONAL DATA.............................................................................................................................. 18
4. REFRIGERANT FLOW DIAGRAM ......................................................................................................... 21
5. PERFORMANCE DATA
5-1. Performance charts ....................................................................................................................... 23
5-2. Air Throw Distance Chart .............................................................................................................. 26
5-3. Cooling Capacity ........................................................................................................................... 27
6. ELECTRICAL DATA
6-1. Electrical Characteristics................................................................................................................ 33
6-2. Electric Wiring Diagrams................................................................................................................ 36
7. INSTALLATION INSTRUCTIONS
7-1. Installation Site Selection ............................................................................................................... 41
7-2. Remote Control Unit Installation Position....................................................................................... 43
7-3. Recommended Wire Length and Diameter ................................................................................... 44
8. FUNCTION
8-1. Room Temperature Control ........................................................................................................... 45
8-2. Dry Operation ................................................................................................................................ 46
8-3. Freeze Prevention ......................................................................................................................... 46
8-4. Outdoor Fan Speed Control .......................................................................................................... 47
9. TROUBLESHOOTING
9-1. Check before and after troubleshooting ........................................................................................ 48
9-2. Air conditioner does not operate .................................................................................................... 49
9-3. Some part of air conditioner does not operate .............................................................................. 53
9-4. Air conditioner operates, but abnormalities are observed ............................................................. 55
9-5. If a sensor is defective ................................................................................................................... 56
10. CHECKING ELECTRICAL COMPONENTS
10-1. Measurement of Insulation Resistance .......................................................................................... 57
10-2. Checking Continuity of Fuse on PCB Ass'y.................................................................................... 58
10-3. Checking Motor Capacitor ............................................................................................................. 58
11. MAINTENANCE
11-1. Changing Address of Remote Control Unit in Indoor Unit ............................................................. 59
INSTRUCTION MANUAL ........................................................................................................ 60
APPENDIX
ii
1
1. OPERATING RANGE
50Hz models Outdoor Unit SAP–C161GA
SAP–C181GA SAP–C241GA
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 32°C D.B. / 23°C W.B. 43°C D.B.
Minimum 19°C D.B. / 14°C W.B. 19°C D.B.
60Hz models
Outdoor Unit SAP–C161JA
SAP–C181JA SAP–C241JA
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 32°C D.B. / 23°C W.B. 43°C D.B.
Minimum 19°C D.B. / 14°C W.B. 19°C D.B.
Outdoor Unit SAP–C181BA
SAP–C241BA
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 29°C D.B. / 19°C W.B. 54°C D.B.
Minimum 19°C D.B. / 14°C W.B. 19°C D.B.
Outdoor Unit SAP–C181MA
SAP–C241MA
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 32°C D.B. / 23°C W.B. 52°C D.B.
Minimum 19°C D.B. / 14°C W.B. 19°C D.B.
2
2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit SAP–K161GJA Outdoor Unit SAP–C161GA
Power Source
220–240V Single phase 50Hz
Voltage rating 220/230/240 V Performance Cooling
Capacity kW 4.70 / 4.70 / 4.70
BTU/h 16,000 / 16,000 / 16,000
Air circulation (High)
m3/h
760
Moisture removal (High) Liters/h 2.3
Electrical Rating Cooling
Available voltage range V 198 ~ 264 Running amperes A 7.2 / 7.2 / 7.3 Power input W 1,540 / 1,570 / 1,610 Power factor % 97 / 95 / 92 C.O.P. W/W 3.1 / 3.0 / 2.9 Compressor locked rotor amperes A 38 / 40 / 41
Features
Controls / Temperature control Microprocessor / I.C. thermostat Control unit Wireless remote control unit Timer 1-hour OFF / 12-hours ON or OFF Fan speeds Indoor / Outdoor 3 and Auto / Auto(Hi, Lo) Airflow direction (Indoor) Horizontal Manual
Vertical Auto Air filter Washable, Anti-Mold Compressor Rotary (Hermetic) Refrigerant / Amount charged at shipment g R22 / 1,090 Refrigerant control Capillary tube Operation sound Indoor : Hi / Me / Lo dB-A 41 / 38 / 36
Outdoor : Hi dB-A 53 Refrigerant tubing connections Flare type Max. allowable tubing length at shipment m 7.5 Refrigerant Narrow tube mm (in.) 6.35(1/4) tube diameter Wide tube mm (in.) 12.7(1/2) Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 285 630
Width mm 995 810
Depth mm 196 275 Package dimensions Height mm 276 704
Width mm 1,070 953
Depth mm 363 369 Weight Net kg 12.0 43.0
Shipping kg 15.0 47.0 Shipping volume
m
3
0.11 0.25
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are: Cooling : Indoor air temperature 27°C D.B. / 19°C W.B. Outdoor air temperature 35°C D.B. / 24°C W.B.
3
Indoor Unit SAP–K161GJA Outdoor Unit SAP–C161JA
Power Source
220V Single phase 60Hz
Voltage rating 220 V Performance Cooling
Capacity kW 4.70
BTU/h 16,000
Air circulation (High)
m3/h
760
Moisture removal (High) Liters/h 2.3
Electrical Rating Cooling
Available voltage range V 198 ~ 242 Running amperes A 8.1 Power input W 1,770 Power factor % 99 C.O.P. W/W 2.7 Compressor locked rotor amperes A 41
Features
Controls / Temperature control Microprocessor / I.C. thermostat Control unit Wireless remote control unit Timer 1-hour OFF / 12-hours ON or OFF Fan speeds Indoor / Outdoor 3 and Auto / Auto(Hi, Lo) Airflow direction (Indoor) Horizontal Manual
Vertical Auto Air filter Washable, Anti-Mold Compressor Rotary (Hermetic) Refrigerant / Amount charged at shipment g R22 / 1,150 Refrigerant control Capillary tube Operation sound Indoor : Hi / Me / Lo dB-A 41 / 38 / 36
Outdoor : Hi dB-A 51 Refrigerant tubing connections Flare type Max. allowable tubing length at shipment m 7.5 Refrigerant Narrow tube mm (in.) 6.35(1/4) tube diameter Wide tube mm (in.) 12.7(1/2) Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 285 630
Width mm 995 810
Depth mm 196 275 Package dimensions Height mm 276 704
Width mm 1,070 953
Depth mm 363 369 Weight Net kg 12.0 43.0
Shipping kg 15.0 47.0 Shipping volume
m
3
0.11 0.25
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are: Cooling : Indoor air temperature 27°C D.B. / 19°C W.B. Outdoor air temperature 35°C D.B. / 24°C W.B.
4
Indoor Unit SAP–K181GJA SAP–K181MBA Outdoor Unit SAP–C181GA SAP–C181MA
Power Source
220–240V Single phase 50Hz
Voltage rating 220/230/240 V Performance Cooling
Capacity kW 5.15 / 5.15 / 5.15
BTU/h 17,600 / 17,600 / 17,600
Air circulation (High)
m3/h
760
Moisture removal (High) Liters/h 2.7
Electrical Rating Cooling
Available voltage range V 198 ~ 264 Running amperes A 9.6 / 9.5 / 9.5 Power input W 2,030 / 2,060 / 2,110 Power factor % 96 / 94 / 93 C.O.P. W/W 2.5 / 2.5 / 2.4 Compressor locked rotor amperes A 45 / 46 / 48
Features
Controls / Temperature control Microprocessor / I.C. thermostat Control unit Wireless remote control unit Timer 1-hour OFF / 12-hours ON or OFF Fan speeds Indoor / Outdoor 3 and Auto / Auto(Hi, Lo) Airflow direction (Indoor) Horizontal Manual
Vertical Auto Air filter Washable, Anti-Mold Compressor Rotary (Hermetic) Refrigerant / Amount charged at shipment g R22 / 1,140 Refrigerant control Capillary tube Operation sound Indoor : Hi / Me / Lo dB-A 41 / 38 / 36
Outdoor : Hi dB-A 53 Refrigerant tubing connections Flare type Max. allowable tubing length at shipment m 7.5 Refrigerant Narrow tube mm (in.) 6.35(1/4) tube diameter Wide tube mm (in.) 12.7(1/2) Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 285 630
Width mm 995 810
Depth mm 196 275 Package dimensions Height mm 276 704
Width mm 1,070 953
Depth mm 363 369 Weight Net kg 12.0 47.5
Shipping kg 15.0 52.0 Shipping volume
m
3
0.11 0.25
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are: Cooling : Indoor air temperature 27°C D.B. / 19°C W.B. Outdoor air temperature 35°C D.B. / 24°C W.B.
5
Indoor Unit SAP–K181GJA SAP–K181MBA Outdoor Unit SAP–C181JA SAP–C181BA
Power Source
220V Single phase 60Hz
Voltage rating 220 V Performance Cooling
Capacity kW 5.15
BTU/h 17,600
Air circulation (High)
m3/h
760
Moisture removal (High) Liters/h 2.7
Electrical Rating Cooling
Available voltage range V 198 ~ 242 Running amperes A 7.8 Power input W 1,700 Power factor % 99 C.O.P. W/W 3.0 Compressor locked rotor amperes A 41
Features
Controls / Temperature control Microprocessor / I.C. thermostat Control unit Wireless remote control unit Timer 1-hour OFF / 12-hours ON or OFF Fan speeds Indoor / Outdoor 3 and Auto / Auto(Hi, Lo) Airflow direction (Indoor) Horizontal Manual
Vertical Auto Air filter Washable, Anti-Mold Compressor Rotary (Hermetic) Refrigerant / Amount charged at shipment g R22 / 1,150 Refrigerant control Capillary tube Operation sound Indoor : Hi / Me / Lo dB-A 41 / 38 / 36
Outdoor : Hi dB-A 51 Refrigerant tubing connections Flare type Max. allowable tubing length at shipment m 7.5 Refrigerant Narrow tube mm (in.) 6.35(1/4) tube diameter Wide tube mm (in.) 12.7(1/2) Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 285 630
Width mm 995 810
Depth mm 196 275 Package dimensions Height mm 276 704
Width mm 1,070 953
Depth mm 363 369 Weight Net kg 12.0 47.5
Shipping kg 15.0 52.0 Shipping volume
m
3
0.11 0.25
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are: Cooling : Indoor air temperature 27°C D.B. / 19°C W.B. Outdoor air temperature 35°C D.B. / 24°C W.B.
6
Indoor Unit SAP–K241GJA SAP–K241GJA Outdoor Unit SAP–C241GA SAP–C241MA
Power Source
220–240V Single phase 50Hz
Voltage rating 220/230/240 V Performance Cooling
Capacity kW 6.40 / 6.45 / 6.45
BTU/h 21,800 / 22,000 / 22,000
Air circulation (High)
m3/h
830
Moisture removal (High) Liters/h 3.3
Electrical Rating Cooling
Available voltage range V 198 ~ 264 Running amperes A 12.8 / 12.8 / 12.8 Power input W 2,650 / 2,680 / 2,760 Power factor % 94 / 91 / 90 C.O.P. W/W 2.4 / 2.4 / 2.3 Compressor locked rotor amperes A 67 / 70 / 73
Features
Controls / Temperature control Microprocessor / I.C. thermostat Control unit Wireless remote control unit Timer 1-hour OFF / 12-hours ON or OFF Fan speeds Indoor / Outdoor 3 and Auto / Auto(Hi, Lo) Airflow direction (Indoor) Horizontal Manual
Vertical Auto Air filter Washable, Anti-Mold Compressor Rotary (Hermetic) Refrigerant / Amount charged at shipment g R22 / 1,785 Refrigerant control Capillary tube Operation sound Indoor : Hi / Me / Lo dB-A 43 / 41 / 39
Outdoor : Hi dB-A 54 Refrigerant tubing connections Flare type Max. allowable tubing length at shipment m 10 Refrigerant Narrow tube mm (in.) 6.35(1/4) tube diameter Wide tube mm (in.) 15.88(5/8) Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 285 630
Width mm 995 810
Depth mm 196 275 Package dimensions Height mm 276 704
Width mm 1,070 953
Depth mm 363 369 Weight Net kg 12.0 59.0
Shipping kg 15.0 62.0 Shipping volume
m
3
0.11 0.25
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are: Cooling : Indoor air temperature 27°C D.B. / 19°C W.B. Outdoor air temperature 35°C D.B. / 24°C W.B.
7
Indoor Unit SAP–K241GJA SAP–K241GJA Outdoor Unit SAP–C241JA SAP–C241BA
Power Source
220V Single phase 60Hz
Voltage rating 220 V Performance Cooling
Capacity kW 6.40
BTU/h 21,800
Air circulation (High)
m3/h
830
Moisture removal (High) Liters/h 3.3
Electrical Rating Cooling
Available voltage range V 198 ~ 242 Running amperes A 14.5 Power input W 2,890 Power factor % 91 C.O.P. W/W 2.2 Compressor locked rotor amperes A 89
Features
Controls / Temperature control Microprocessor / I.C. thermostat Control unit Wireless remote control unit Timer 1-hour OFF / 12-hours ON or OFF Fan speeds Indoor / Outdoor 3 and Auto / Auto(Hi, Lo) Airflow direction (Indoor) Horizontal Manual
Vertical Auto Air filter Washable, Anti-Mold Compressor Rotary (Hermetic) Refrigerant / Amount charged at shipment g R22 / 1,770 Refrigerant control Capillary tube Operation sound Indoor : Hi / Me / Lo dB-A 43 / 41 / 39
Outdoor : Hi dB-A 54 Refrigerant tubing connections Flare type Max. allowable tubing length at shipment m 10 Refrigerant Narrow tube mm (in.) 6.35(1/4) tube diameter Wide tube mm (in.) 15.88(5/8) Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 285 630
Width mm 995 810
Depth mm 196 275 Package dimensions Height mm 276 704
Width mm 1,070 953
Depth mm 363 369 Weight Net kg 12.0 58.0
Shipping kg 15.0 61.0 Shipping volume
m
3
0.11 0.25
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are: Cooling : Indoor air temperature 27°C D.B. / 19°C W.B. Outdoor air temperature 35°C D.B. / 24°C W.B.
8
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor Unit SAP–K161GJA
Controller PCB
Part No. POW-K181GJA Controls Microprocessor Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-2S2E
Fan & Fan Motor
Type Cross-flow Q'ty ... Dia. and length mm 1 ... ø88 / L746 Fan motor model ... Q'ty UF2-31A5P-S ... 1 No. of poles ... 50/60Hz rpm (High ) 2 ... 1,440 / 1,410 Nominal output W 30 Coil resistance (Ambient temp. 20°C) WHT-BRN : 133.7
WHT-PNK : 168.4
— — — — — —
Safety devices Type Internal protector
Operating temp. Open °C 130±8
Close Automatic reclosing
Run capacitor µF 2.0
VAC 440
Flap Motor
Type Stepping motor Model MP24GA2 Rating DC 12 V Coil resistance (Ambient temp. 25°C) Each terminals (1–2, 1–3, 1–4, 1–5) : 400 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube Rows 2 Fin pitch mm 1.3 Face area
m
2
0.156
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
9
Indoor Unit SAP–K181GJA SAP–K181MBA
Controller PCB
Part No. POW-K181GJA Controls Microprocessor Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-2S2E
Fan & Fan Motor
Type Cross-flow Q'ty ... Dia. and length mm 1 ... ø88 / L746 Fan motor model ... Q'ty UF2-31A5P-S ... 1 No. of poles ... 50/60Hz rpm (High) 2 ... 1,440 / 1,410 Nominal output W 30 Coil resistance (Ambient temp. 20°C) WHT-BRN : 133.7
WHT-PNK : 168.4
— — — — — —
Safety devices Type Internal protector
Operating temp. Open °C 130±8
Close Automatic reclosing
Run capacitor µF 2.0
VAC 440
Flap Motor
Type Stepping motor Model MP24GA2 Rating DC 12 V Coil resistance (Ambient temp. 25°C) Each terminals (1–2, 1–3, 1–4, 1–5) : 400 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube Rows 2 Fin pitch mm 1.3 Face area
m
2
0.156
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
10
Indoor Unit SAP–K241GJA SAP–K241MBA
Controller PCB
Part No. POW-K241GJA Controls Microprocessor Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-2S2E
Fan & Fan Motor
Type Cross-flow Q'ty ... Dia. and length mm 1 ... ø88 / L746 Fan motor model ... Q'ty UF2-31A5P-S ... 1 No. of poles ... 50/60Hz rpm (High) 2 ... 1,440 / 1,410 Nominal output W 30 Coil resistance (Ambient temp. 20°C) WHT-BRN : 133.7
WHT-PNK : 168.4
— — — — — —
Safety devices Type Internal protector
Operating temp. Open °C 130±8
Close Automatic reclosing
Run capacitor µF 2.0
VAC 440
Flap Motor
Type Stepping motor Model MP24GA2 Rating DC 12 V Coil resistance (Ambient temp. 25°C) Each terminals (1–2, 1–3, 1–4, 1–5) : 400 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube Rows 2 Fin pitch mm 1.3 Face area
m
2
0.156
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
11
2-2-2. Outdoor Unit
Outdoor Unit SAP–C161GA
Compressor
Type Rotary (Hermetic) Compressor model C-R140H5W 80610045-S Nominal output W 1,400 Compressor oil ... Amount cc 4GSD-T or SAY-56T ... 500 Coil resistance (Ambient temp. 25°C) C–R : 1.560
C–S : 3.610
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA99150-9201 TS-120N Operating temp. Open °C 145±5 120±5
Close °C 69±11 95±11
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 23.5A
Run capacitor µF 35.0
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller Q'ty ... Dia. 1 ... ø420 Fan motor model ... Q'ty KFG6S-51A5P-S ... 1 No. of poles ... rpm (High) 6 ... 870 Nominal output W 50 Coil resistance (Ambient temp. 20°C) WHT-BRN : 67.09
WHT-YEL : 68.12
YEL-PNK : 15.66
Safety devices Type Internal protector
Operating temp. Open °C 130±8
Close °C Automatic reclosing
Run capacitor µF 4.0
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube Rows 1 Fin pitch mm 1.3 Face area
m
2
0.506
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
12
Outdoor Unit SAP–C161JA
Compressor
Type Rotary (Hermetic) Compressor model C-R132H6D 80612346-S Nominal output W 1,400 Compressor oil ... Amount cc 4GSD-T or SAY-56T ... 500 Coil resistance (Ambient temp. 25°C) C–R : 1.442
C–S : 2.430
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA99828-9201 TS-120N Operating temp. Open °C 145±5 120±5
Close °C 69±11 95±11
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 27A
Run capacitor µF 35.0
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller Q'ty ... Dia. 1 ... ø420 Fan motor model ... Q'ty KFG6S-51A6P-S ... 1 No. of poles ... rpm (220 V, High) 6 ... 860 Nominal output W 50 Coil resistance (Ambient temp. 20°C) WHT-BRN : 81.3
WHT-YEL : 60.86
YEL-PNK : 36.13
Safety devices Type Internal protector
Operating temp. Open °C 130±5
Close °C Automatic reclosing
Run capacitor µF 3.0
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube Rows 1 Fin pitch mm 1.3 Face area
m
2
0.506
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
13
Outdoor Unit SAP–C181GA SAP–C181MA
Compressor
Type Rotary (Hermetic) Compressor model C-2R170H5T 80827445 Nominal output W 1,700 Compressor oil ... Amount cc 4GSD-T or SAY-56T ... 750 Coil resistance (Ambient temp. 25°C) C–R : 1.353
C–S : 3.422
Safety devices Type Internal protector
Overload relay — Operating temp. Open °C Automatic opening
Close °C Automatic reclosing
Operating amp.(Ambient temp. 25°C)
Run capacitor µF 40.0
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller Q'ty ... Dia. 1 ... ø420 Fan motor model ... Q'ty KFG6S-51A5P-S ... 1 No. of poles ... rpm (230 V, High) 6 ... 870 Nominal output W 50 Coil resistance (Ambient temp. 20°C) WHT-BRN : 67.09
WHT-YEL : 68.12
YEL-PNK : 15.66
Safety devices Type Internal protector
Operating temp. Open °C 130±8
Close °C Automatic reclosing
Run capacitor µF 4.0
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube Rows 1 Fin pitch mm 1.3 Face area
m
2
0.506
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
14
Outdoor Unit SAP–C181JA SAP–C181BA
Compressor
Type Rotary (Hermetic) Compressor model C-R132H6D 80612346-S Nominal output W 1,400 Compressor oil ... Amount cc 4GSD-T or SAY-56T ... 500 Coil resistance (Ambient temp. 25°C) C–R : 1.442
C–S : 2.430
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA99828-9201 TS-120N Operating temp. Open °C 145±5 120±5
Close °C 69±11 95±11
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 27A
Run capacitor µF 35.0
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller Q'ty ... Dia. 1 ... ø420 Fan motor model ... Q'ty KFG6S-51A6P-S ... 1 No. of poles ... rpm (220 V, High) 6 ... 860 Nominal output W 50 Coil resistance (Ambient temp. 20°C) WHT-BRN : 81.3
WHT-YEL : 60.86
YEL-PNK : 36.13
Safety devices Type Internal protector
Operating temp. Open °C 130±5
Close °C Automatic reclosing
Run capacitor µF 3.0
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube Rows 1 Fin pitch mm 1.3 Face area
m
2
0.506
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
15
Outdoor Unit SAP–C241GA SAP–C241MA
Compressor
Type Rotary (Hermetic) Compressor model C-R221H5S 80687145 Nominal output W 2,200 Compressor oil ... Amount cc 4GSD-T or SAY-56T ... 1,350 Coil resistance (Ambient temp. 25°C) C–R : 0.777
C–S : 2.408
Safety devices Type Internal protector External(OLR T)
Overload relay OL-D24 Operating temp. Open °C Automatic opening 150±5
Close °C Automatic reclosing 63±11
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 59A
Run capacitor µF 40.0
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller Q'ty ... Dia. 1 ... ø420 Fan motor model ... Q'ty KFG6S-51D5P-S ... 1 No. of poles ... rpm (230 V, High) 6 ... 890 Nominal output W 50 Coil resistance (Ambient temp. 20°C) WHT-BRN : 56.09
WHT-YEL : 42.13
YEL-PNK : 15.99
Safety devices Type Internal protector
Operating temp. Open °C 130±8
Close °C Automatic reclosing
Run capacitor µF 4.0
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube Rows 2 Fin pitch mm 1.2 Face area
m
2
0.499
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
16
Outdoor Unit SAP–C241JA SAP–C241BA
Compressor
Type Rotary (Hermetic) Compressor model C-R191H6M 80649546 Nominal output W 1,900 Compressor oil ... Amount cc 4GSD-T or SAY-56T ... 1,350 Coil resistance (Ambient temp. 25°C) C–R : 0.595
C–S : 2.693
Safety devices Type Internal protector External(OLR T)
Overload relay OL-D24 Operating temp. Open °C Automatic opening 150±5
Close °C Automatic reclosing 63±11
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 59A
Run capacitor µF 35.0
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller Q'ty ... Dia. 1 ... ø420 Fan motor model ... Q'ty KFG6S-51C6P-S ... 1 No. of poles ... rpm (220 V, High) 6 ... 910 Nominal output W 50 Coil resistance (Ambient temp. 20°C) WHT-BRN : 85.16
WHT-YEL : 32.84
YEL-PNK : 51.57
Safety devices Type Internal protector
Operating temp. Open °C 130±8
Close °C Automatic reclosing
Run capacitor µF 3.5
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube Rows 2 Fin pitch mm 1.2 Face area
m
2
0.499
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2-3. Other Component Specifications
17
Thermostat (Fan Speed Control 23S) MQT5S
Switching temp. °C
high LOW 28.5°C ± 1.5 low HIGH 31.5°C ± 2
Contact rating AC 220V, 3A
Power Relay (PR) G7L-2A-TUB
Coil rating AC 200–240V, 50/60Hz Coil resistance (at 23°C) 21 ±15% Contact rating AC 220V, 25A
Outdoor Unit SAP–C161GA SAP–C161JA
SAP–C181GA SAP–C181JA SAP–C181MA SAP–C181BA SAP–C241GA SAP–C241JA SAP–C241MA SAP–C241BA
Thermistor (Room sensor) DTN-TKS142B
Resistance k 25°C 5.0 ± 3%
Thermistor (Coil sensor) DTN-TKS131B
Resistance k 0°C 15.0 ± 2%
Transformer (TR) ATR-J105
Rating Primary AC 230V, 50/60Hz
Secondary 19V, 0.526A Capacity 10VA
Coil resistance (at 21°C) Primary (WHT – WHT): 205 ± 10%
Secondary (BRN – BRN): 2.0 ± 10%
Thermal cut-off temp. 150°C
Indoor Unit SAP–K161GJA
SAP–K181GJA SAP–K181MBA SAP–K241GJA SAP–K241MBA
18
3. DIMENSIONAL DATA
Indoor Unit SAP–K161GJA
SAP–K181GJA SAP–K181MBA SAP–K241GJA SAP–K241MBA
28545
995
45
147.5 147.5
196 (3)
Center of tubing hole (2 places)
Narrow tube ø6.35 (1/4")
Drain hose ø18
Wide tube ø12.7 (1/2") K161, K181 Wide tube ø15.88 (5/8") K241
Remote control unit
172
61 23
Unit : mm
19
Outdoor Unit SAP–C161GA SAP–C161JA
SAP–C181GA SAP–C181JA SAP–C181MA SAP–C181BA
810 15
630
22
538
AIR INTAKE
AIR DISCHARGE
136
140
302
325
ø12
5
275
98 45
Narrow tube service valve ø6.35 (1/4")
Wide tube service valve ø12.7 (1/2")
Unit : mm
20
Outdoor Unit SAP–C241GA SAP–C241JA SAP–C241MA SAP–C241BA
275
98 45
810 15
630
22
538 136
140
302
325
Narrow tube service valve ø6.35 (1/4")
Wide tube service valve ø15.88 (5/8")
Air intake
Air discharge
Unit : mm
4. REFRIGERANT FLOW DIAGRAM
21
Capillary tube
Compressor
Accumulator
Wide tube service valve
Wide tube
O.D. ø12.7 mm (1/2 ")
Narrow tube service valve
Narrow tube
O.D. ø6.35 mm (1/4")
Condenser
Indoor Unit Outdoor Unit
,
Evaporator
Indoor Unit SAP–K161GJA
SAP–K161GJA SAP–K181GJA SAP–K181MBA
Outdoor Unit SAP–C161GA
SAP–C161JA SAP–C181JA SAP–C181BA
Capillary tube
Capillary for liquid injection
Compressor
Accumulator
Wide tube service valve
Wide tube
O.D. ø12.7 mm (1/2 ")
Narrow tube service valve
Narrow tube
O.D. ø6.35 mm (1/4")
Condenser
Indoor Unit Outdoor Unit
Evaporator
Indoor Unit SAP–K181GJA
SAP–K181MBA
Outdoor Unit SAP–C181GA
SAP–C181MA
22
Insulation of Refrigerant Tubing
Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min. 8 mm.
After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack.
IMPORTANT
CAUTION
Wide tube
Thickness: Min. 8 mm
Insulation
Narrow tube
Thickness: Min. 8 mm
Indoor Unit SAP–K241GJA
SAP–K241GJA SAP–K241MBA SAP–K241MBA
Outdoor Unit SAP–C241GA
SAP–C241JA SAP–C241MA SAP–C241BA
Compressor
Wide tube service valve
Wide tube
O.D. ø15.88 mm (5/8 ")
Narrow tube service valve
Narrow tube
O.D. ø6.35 mm (1/4")
Evaporator
Capillary for liquid injection
Indoor Unit Outdoor Unit
Muffler
Capillary tube
Condenser
Strainer
Accumulator
5. PERFORMANCE DATA
5-1. Performance charts
23
Cooling Characteristics
Low pressure at wide tube service valve MPa (kgf/cm
2
G)
1.38 (13)
1.28 (12)
1.18 (11)
1.08 (10)
0.98 ( 9 )
0.89 ( 8 )
0.79 ( 7 )
0.69 ( 6 )
0.59 ( 5 )
0.49 ( 4 )
0.39 ( 3 )
1.47 (14)
25 30 35 40 45 50
Indoor inlet air
D.B. temp. (°C)
Outdoor fan speed
HighLow
13 12 11 10
9 8 7 6 5
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Operating current (A)
14
Indoor inlet air
D.B. temp. (°C)
Outdoor fan speed
HighLow
32 27 21
32 27
21
...... Points of Rating condition
Black dots in above charts indicate the following rating conditions.
Cooling: Indoor air temperature 27°C D.B./19°C W.B.
Outdoor air temperature 35°C D.B./24°C W.B.
NOTE
Indoor Unit SAP–K161GJA Outdoor Unit SAP–C161GA
Cooling Characteristics
Low pressure at wide tube service valve MPa (kgf/cm
2
G)
1.38 (13)
1.28 (12)
1.18 (11)
1.08 (10)
0.98 ( 9 )
0.89 ( 8 )
0.79 ( 7 )
0.69 ( 6 )
0.59 ( 5 )
0.49 ( 4 )
0.39 ( 3 )
1.47 (14)
13 12 11 10
9 8 7 6 5
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Operating current (A)
14
Indoor inlet air
D.B. temp. (°C)
Outdoor fan speed
HighLow
25 30 35 40 45 50
Indoor inlet air
D.B. temp. (°C)
Outdoor fan speed
HighLow
32 27 21
32 27 21
Indoor Unit SAP–K161GJA Outdoor Unit SAP–C161JA