Sanyo MTR-L03, MTR-5000 User Manual

Data Acquisition System
Monitors operating conditions
by PC
Stores operating records
in the PC
Informs a user of abnormality
of device by e-mail
Operating conditions can be
set through LAN.
Two-step/day operation
is programmable.
MTR-5000 MTR-L03
Monitors operating conditions
Monitors operating conditions
by PC
by PC
in the PC
in the PC
Informs a user of abnormality
Informs a user of abnormality
of device by e-mail
of device by e-mail
Operating conditions can be
Operating conditions can be
set through LAN.
set through LAN.
Cooled Incubator
MIR-254
Ethernet (LAN) Interface
MTR-L03
CO2 Incubator
MCO-19AIC
CO2 Incubator
MCO-80IC
Two-step/day operation
Two-step/day operation
Biomedical Freezer
MDF-U537D
is programmable.
is programmable.
Ultra-Low Freezer
MDF-U53V
Connection examples of a monitoring computer and SANYO biomedical devices to be monitored by LAN*
*For connectable devices, consult with our company. *Those devices and the monitoring computer are connected using the special
software, MTR-5000.
*A personal computer is not included in this system.
SANYO Data acquisition software
MTR-5000
Data Acquisition System
Features
• Device-related information such as temperature, CO
2 and O2 concentration,
and operating condition can be integratedly monitored with one LAN­connected personal computer.
Items that can be monitored depend on the connected devices.
• Operating records are stored in sequence in the PC. It is unnecessary to fill in paper records or to enter in a record book. It is easy to convert the data into a graph.
Please note that there is a case in which data must be recorded on a paper.
• Devices can be set up remotely from a distant point, which saves entering a clean room.
When the operating setting can be changed through the network, it is impossible to change the operation setting on the panel of each device.
Main functions
• Setting the upper/lower limits will cause you to be informed of an abnormality by e-mail if the data is out of the range, and you will also be informed when the system recovers from the abnormality. In addition, the system can be set so that the device conditions will be informed at a designated time whether or not there is an abnormality.
A mail account which can be connected to an SMTP-compatible mail server is required.
• Two-step/day operation to set up two different temperatures is programmable.
For example, energy saving can be expected by changing to different setting temperatures for day and night operations.
• System access is protected by ID/Password.
Specifications
Model
Product name
Exterior dimensions (W x D x H)
Power supply
Output terminal
Compatible protocol
Note
Model
Product name
No. of devices to be monitored
Devices to be monitored
Monitoring PC
Recommendable specifications
• SANYO cannot guarantee operations of all PCs satisfying the above recommendable specifications.
• If other software is installed in a PC in which this software was installed, information may be deleted due to malfunction.
Caution: SANYO guarantees the product under certain warranty conditions. SANYO in no way shall be responsible for any loss of content or damage to content.
• Appearance and specifications are subject to change without notice.
MTR-L03
Ethernet (LAN) Interface
74 x 63 x 58mm (2.9” x 2.5” x 2.3”)
DC5V (to be supplied from the attachment device)
RJ-45 twist pair cable 8-pin connector
TCP/IP *Only static IP (Impossible to use DHCP.)
MTR-L03 is not equipped with sensors for temperature, etc. As information such as in-box temperature, etc., results measured at the sensors of the incubators and freezers are transmitted to the network.
MTR-5000
SANYO Data acquisition software
32 devices at most (up to 100 ch)
SANYO biomedical devices connected to MTR-L03 or MTR­480 (RS232C or RS-485)
CPU: Core2DUO or higher
Memory: 1GB or more HDD: 80 GB or more OS: Microsoft Windows XP SP3 (compatible with Windows Vista)
Map Display
Conditions of biomedical devices can be displayed on the map intelligibly. (A device showing a warning is displayed in red.)
Channel List
The condition of each channel (measurement item) is displayed together with the upper and lower limit setting data.
Set Value Information
Dimensions MTR-L03
65 (2.6”)
74 (2.9”)
58 (2.3”)
[Unit : mm (inch)]
63 (2.5”)
28 (1.1”)
Set values of SANYO biomedical devices can
Graph Display
Condition change of a selected channel can be displayed on a graph.
be changed through the network.
*The above function is only applicable to remote­controllable devices.
Note:
All screen images shown in the catalog are composite images. In the unlikely event of a mechanical failure, the contents of the incubator and any recorded data cannot be guaranteed.
SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for:
Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001
Distributed by:
SANYO Electric Co., Ltd.
Biomedical Division
http://biomedical.sanyo.com/
©2009 SANYO Printed in Japan 2009.7 MA
SHR147