Sanyo MPX-CD92P Instruction Manual

Page 1
INSTRUCTION MANUAL
MPX-CD92P
Multiplexer
Multiplexer
Multiplexeur
Multiplexor
Multi distributore
English GB
Deutsch D
Français F
Italiano I
About this manual
Before installing and using this unit, please read this manual carefully. Be sure to keep it handy for later reference.
Über diese Anleitung
Lesen Sie bitte diese Bedienungsanleitung vor der Installation und der Verwendung des Gerätes sorgfältig durch. Bewahren Sie die Anleitung zum späteren Nachschlagen auf.
À propos de ce manuel
Avant d’installer et d’utiliser cet appareil, veuillez lire ce manuel attentivement. Assurez-vous de le garder à portée de la main pour référence ultérieure.
Acerca de este manual
Antes de instalar y usar este aparato, lea detenidamente este manual. Asegúrese de guardarlo a mano para futuras referencias.
Nota su questo manuale
Leggere attentamente questo manuale prima di passare all’installazione ed all’uso di questo apparecchio.
Page 2
PRECAUTION
WARNING: TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR OTHER MOISTURE. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only. If the power supply cord (AC power cord) of this appliance is damaged, it must be replaced. Return to a SANYO Authorised Service Centre for replacement of the cord.
Location
For safe operation and satisfactory performance of your multiplexer, keep the following in mind when selecting a place for its installation:
Shield it from direct sunlight and keep it away from sources of
intense heat. Avoid dusty or humid places.
Avoid places with insufficient ventilation for proper heat
dissipation. Do not block the ventilation holes at the top and bottom of the multiplexer. Do not place the unit on a carpet because this will block the ventilation holes.
Install the multiplexer in a horizontal position only.
Avoid locations subject to strong vibrations.
Avoid moving the multiplexer between cold and hot locations.
Do not place the multiplexer directly on top of a monitor TV,
as this may cause playback or recording problems.
Avoiding Electrical Shock and Fire
Do not handle the power cord with wet hands.
Do not pull on the power cord when disconnecting it from an
AC wall outlet. Grasp it by the plug. If any liquid is spilled on the multiplexer, unplug the power
cord immediately and have the unit inspected at a factory-authorised service centre.
Do not place anything directly on top of this multiplexer.
SERVICE
This unit is a precision instruments and if treated with care, will provide years of satisfactory performance. However, in the event of a problem, the owner is advised not to attempt to make repairs or open the cabinet. Servicing should always be referred to your dealer or Sanyo Authorized Service Centre.
CAUTION
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacture’s instructions.
English 1
Page 3
CONTENTS
FEATURES
PARTS NAMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FRONT PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
REAR PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
BASIC CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . 5
CONNECTIONS TO THE S-VIDEO
TERMINALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CONNECTIONS TO THE ALARM IN AND
RS232C/RS485 TERMINALS . . . . . . . . . . . . . . . . . 6
REMOTE CONTROLLER CIRCUIT
CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
BASIC OPERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 8
MODE SWITCHING . . . . . . . . . . . . . . . . . . . . . . . . . 8
SECURITY LOCK FUNCTION . . . . . . . . . . . . . . . . 9
SETTINGS BACKUP FUNCTION . . . . . . . . . . . . . . 9
RESET FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . 9
LIVE PICTURE MODE . . . . . . . . . . . . . . . . . . . . . . . . . 10
FULL SCREEN OPERATIONS . . . . . . . . . . . . . . . 12
4 DIVISIONS SPLIT SCREEN OPERATIONS . . . 14
MULTI-DISPLAY SCREEN OPERATIONS . . . . . . 15
PLUS-DISPLAY SCREEN OPERATIONS . . . . . . 15
MONITOR 2 OPERATIONS . . . . . . . . . . . . . . . . . . . . . 17
VCR PLAYBACK MODE . . . . . . . . . . . . . . . . . . . . . . . 18
FULL SCREEN OPERATIONS . . . . . . . . . . . . . . . 20
4 DIVISIONS SPLIT SCREEN OPERATIONS . . . 22
MULTI-DISPLAY SCREEN OPERATIONS . . . . . . 23
PLUS-DISPLAY SCREEN OPERATIONS . . . . . . 23
MENU SETTING MODE . . . . . . . . . . . . . . . . . . . . . . . . 25
LANGUAGE SETTING . . . . . . . . . . . . . . . . . . . . . 26
CLOCK AND SUMMER TIME SETTING . . . . . . . . 27
VCR SETTING AND EXTERNAL CONTROL
COMMUNICATION SPEED SETTING . . . . . . . . . 29
ALARM AND SENSOR SETTING . . . . . . . . . . . . . 31
ACTIVE RECORDING AND VIDEO LOSS
SETTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
MONITOR SETTINGS . . . . . . . . . . . . . . . . . . . . . . 35
CAMERA SETTING . . . . . . . . . . . . . . . . . . . . . . . . 36
SETTING EACH CAMERA DISPLAY POSITION
IN SPLIT SCREEN DISPLAY MODE . . . . . . . . . . . 43
CLOCK AND TITLE DISPLAY SETTINGS . . . . . . 44
ALARM DATA DISPLAY . . . . . . . . . . . . . . . . . . . . 45
ALARMS OPERATIONS . . . . . . . . . . . . . . . . . . . . . . . 46
INTERFACE SPECIFICATIONS . . . . . . . . . . . . . . . . . 48
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Using this unit you can display the live pictures from the cameras in split screen display mode (9 or 4 divisions) while recording, and the recorded pictures can also be displayed in split screen display mode.
High-speed switching (up to single field switching)
1, 4, 9 screens display modes, with possibility of displaying
an automatic sequential live or recorded pictures display in the bottom right 1/4 of the screen while in 9 split screen display mode.
Full screen display on monitor 2 and during alarms automatic
switching to the alarm screen. The following operations are possible at each camera
according to the timer settings: Programmed recording of certain or all cameras only can be
done according to the day or night periods. Different alarm durations of certain or all cameras can be set
according to the day or night periods. Live or recorded pictures of certain or all cameras can be
masked so they are not visible according to the day or night periods.
Automatic switching delay can be set for each camera
according to the day or night periods. Video sensor points areas can be set for each camera.
Trigger can start alarm recording operations in priority. If the video signal is interrupted at any of the cameras, the
frozen image just previous to the interruption or colour bars can be displayed (selectable for each camera).
The unit can be controlled by computer through the RS232C
connection. A system controller (sold separately) can be used through the
RS485 (RJ-11) connection. 2 monitors output and S-VIDEO input/output.
Up to 100 alarm entries can be displayed on-screen.
ACCESSORIES
1 Power cord x1 2 Fixer, Power cord tie x1
2
To mount this unit onto a rack, please use the rack mount hardware sold separately.
2 English
Page 4
PARTS NAMES
FRONT PANEL
1234567HKI
SEQUENCE
MENU
NEXT
EXIT
DISPLAY
ALL
RESET
MENU
RESET
+
M
N
POWER
SELECT
1 2 3 4 5 6 7 8 9
PLUS QUAD MULTI LIVE VCR
MON 2 ZOOM STILL
LJGF98
This unit is not equipped with a power switch. The power is turned on/off when the supplied power cord is connected/disconnected at the power source.
1 POWER indicator 2 Camera SELECT buttons and camera indicators
Use these buttons to select the picture from the
corresponding camera. Also, when in still image, sequential
display, 4 divisions split screen or multi-display screen
modes, press one of these buttons to return to the normal
picture full screen display of the corresponding camera.
3 PLUS button and indicator 4 QUAD button and indicator
In sequential display, full screen display or multi-display
screen modes, press this button to switch to 4 divisions
display screen. Press repeatedly to switch to subsequent 4
divisions screens.
5 MULTI button and indicator 6 LIVE button and indicator
Press this button to select the live input mode.
7 VCR button and indicator
F STILL button and indicator
In full screen display mode, press this button to freeze the displayed image. Press the button one more time to cancel.
G SEQUENCE button and indicator
In 4 divisions split screen or full screen display modes, press this button for an automatic sequential full screen display of the pictures.
H MENU button (see page 8)
Press this button to display the menus. Press repeatedly to select the different menus in order.
I NEXT button J EXIT/DISPLAY button K j, l, c, d button L +, – button M ALL RESET button (see page 9) N MENU RESET button (see page 9)
Press this button to select the VCR playback input mode.
8 MON 2 button and indicator
Press this button to set the output at monitor 2.
9 ZOOM button and indicator
In full screen display mode, press this button for a 2x
zoomed in image. Press the button one more time to cancel.
About the cooling fan
In order to keep the unit internal temperature low, a fan is provided on the side of the unit. If the fan does not operate properly, the POWER indicator will flash to indicate a problem. Unplug the unit from the power supply and check to make sure nothing is obstructing the fan. If after the power is restored to the unit, the POWER indicator still flashes, do not use the unit and consult your dealer.
English 3
Page 5
PARTS NAMES
REAR PANEL
I
JK
IN
CAMERA
1
123C456789
2
OUT
S-VIDEO
MONITOR
VCRVCR
IN
OUTIN OUT
3456 7 89 F G H
1 CAMERA IN terminals (1 – 9) 2 CAMERA OUT terminals (1 – 9)
Each camera signal is output directly at these terminals.
3 S-VIDEO VCR IN (VCR S-VHS signal input) terminal 4 S-VIDEO VCR OUT (VCR S-VHS signal output) terminal 5 MONITOR 1 (Monitor 1 S-VHS signal output) terminal 6 VCR IN (Video cassette recorder input) terminal 7 VCR OUT (Video cassette recorder output) terminal 8 MONITOR 1 (Monitor 1 output) terminal 9 MONITOR 2 (Monitor 2 output) terminal F RS-485 control ports (RS485 A, B)
(A) RJ-11 A terminal
Used for connection with a modular cable.
(B) RJ-11 B terminal
Used for connection with a modular cable.
Note:•Do not connect to a phone line.
Only up to two RS-485 control ports can be used.
Do not use all of the RS-485 control ports.
G RS-232C (RS232C) terminal
To control this unit using a personal computer, connect the
computer serial terminal to this terminal using a 9-pin
D-SUB cable (sold separately).
H Interface setting DIP switches (ADDRESS, RS-232C,
RS-485, TERMINATE)
I SENSOR ALARM OUT terminals (1 – 9)
MONITOR
112AB
RS485
K CONTROL terminal
* Used for connection with a twisted-pair cable.
L AC Power socket (AC IN~)
Insert the power cord female plug firmly into this socket. When the other plug of the power cord is connected to a live power source, the POWER indicator on the front panel will light.
M Power cord holder
Using the supplied tie, attach the power cord to the holder as illustrated.
ALARM
IN
SENSOR ALARM
12345678
OUT
CONTROL
RS232C
9
CABCALC
485
Pin Signal
C Ground A RS485 terminal * B RS485 terminal * C Common
AL Alarm output (DC 5V)
C Common R1 Remote input 1 R2 Remote input 2
C Common
SW Switching input (DC 5V)
C Common
NC
R1 R2CSW
ON
123456789
ADDRESS
C
L
ON
TERMI
10
NATE
OFF
232
M
J ALARM IN (Alarm signal input) terminals
The alarm triggers input to the unit are output at the AL pin of the CONTROL terminal.
4 English
Page 6
CONNECTION
RS232C
A B
RS485
485
ON
OFF
232
S-VIDEO
CONTROL
ADDRESS
TERMI NATE
Before making any connection, make sure all the devices are turned off. Before making the connections, please refer to the instruction manual accompanying each device. If the devices are not connected
properly, that may cause a fire and/or damages.
BASIC CONNECTIONS
IN
123C456789
OUT
CAMERA
MONITOR
S-VIDEO
NOTE:
The camera signal input at each CAMERA IN terminal is throughput at the corresponding CAMERA OUT terminal. The CAMERA IN terminals are automatically terminated at 75 .
When no connection is made to the CAMERA
OUT terminal, the CAMERA IN terminal 75
termination is made automatically.
When a connection is made to the CAMERA OUT terminal, the CAMERA IN terminal
termination is open, you must therefore make sure the CAMERA OUT side is terminated.
ALARM
IN
123456789
SENSOR ALARM
OUT
VCRVCR
ININ OUTOUT
MONITOR
112AB
RS485
1 32 465 798
Video input terminal
CONTROL
RS232C
Monitors (sold separately)
NC
CABCALC
485
ON
12345678910
Video input terminal
R1 R2CSW
ADDRESS
232
ALARM input
C
ON
TERMI NATE
OFF
terminal
Ground
Timelapse VCR (sold separately)
Ground
Switching output terminal
CONNECTIONS TO THE S-VIDEO TERMINALS
If connections are made to the S-VIDEO terminals, they will have the priority.
MONITOR
ININ OUTOUT
S-VIDEO
S-VIDEO output
terminal
S-VIDEO input terminal
S-VIDEO input terminal
1 32 465 798
Timelapse VCR (sold separately)
English 5
MONITOR
VCRVCR
112
Page 7
CONNECTION
CONNECTIONS TO THE ALARM IN AND RS232C/RS485 TERMINALS
A RS485 (RJ-11) terminal connection
Make the connection to the RS485 control terminal using a modular cable (sold separately).
If using a straight type cable, connect it between the A
terminals, or between the B terminals (see illustration below). If using a crossed type cable, connect it from the A terminal
to the B terminal, or from the B terminal to the A terminal (see illustration below).
MONITOR
12AB
To terminal A To terminal A
Straight-type cable Cross-type cable
Not used
1
Not used
2
16
3 4
Not used
5
Not used
6
1 2
16 16 16
3 4 5 6
Straight type
RS485
Not used
1
Not used
2 3 4 5
Not used
6
Not used
Cross type
1 2 3 4 5 6
B Using the push-lock terminals
Make the connections to pins A, B, C (Ground) of the CONTROL terminal using a twisted-pair cable (sold separately).
Then, connect signal A to A, and signal B to B.
Push in to insert cable
Common
RS485
A B
External alarm sensors
(door bell, interphone, etc.)
ALARM
IN
123456789
C
SENSOR ALARM
OUT
CONTROL
NC
CABCALC
C
R1 R2CSW
C
CABCALC
RS232C
R1 R2CSW
C
To B signal
Twisted-pair cable
To A signal
Ground
C SENSOR ALARM OUT terminals
When the unit internal video sensor send a trigger, it will be output at the SENSOR ALARM OUT terminals. By connecting indicator lamps switching circuits to theses connectors (Fig. 1), an indication can be generated when the video sensors send a trigger.
For example, the video sensor alarm indicator lamps could be laid out on a factory floor plan to give accurate indication of trigger location. The terminals are normally open (NO). A trigger at the video sensor for one of the cameras, will switch the signal to LOW.
Fig. 1
1K
Rating values for each connector (at 25˚C)
• Maximum current : 25 mA
• Maximum voltage : 25 V
• Maximum power : 40 mW
RS232C
A
B
9-pin D-SUB cable (sold separately)
Computer
Connect a 9-pin D-SUB cable (sold separately) from the RS232C terminal on the rear panel to the computer serial connector.
Switching output terminal
Common
Common
Alarm input terminal
6 English
Page 8
CONNECTION
REMOTE CONTROLLER CIRCUIT CONNECTIONS
Use the layout below to make a remote controller and make the connections to the remote input pins (R1, R2) of the CONTROL terminal as indicated. This will permit remote controlled operation of this unit. (make contact LOW input)
R1 R2
CONTROL
CABCALC
R1 R2CSW
220
SW 1
SW 2
SW 3
SW 4
SW 5
SW 6
SW 7
SW 8
SW 9
: Camera 1
: Camera 2
: Camera 3
: Camera 4
: Camera 5
: Camera 6
: Camera 7
: Camera 8
: Camera 9
220
300
360
470
C
680
820
1.2k
1.8k
SW: switch
220
220
300
360
470
680
820
1.2k
1.8k
2.2k
3.3k
4.7k
7.5k
13k
27k
68k
SW 10
: Menu selection
SW 11
: VCR playback
SW 12
: Live picture
SW 13
: MULTI
SW 14
: PLUS
SW 15
: Camera sequential
display
SW 16
: Zoom
SW 17
: Still image
SW 18
: Monitor 2
SW 19
: 4 divisions split screen
SW 20
: NEXT
SW 21
: EXIT/DISPLAY
SW 22
: +
SW 23
: –
SW 24
: 3
SW 25
: 2
English 7
Page 9
BASIC OPERATIONS
MODE SWITCHING
When the unit is connected to a power source, the default display mode will be as follows: live picture displayed in a 9 divisions split screen on monitor 1, and sequentially, full screen on monitor 2. You can use the VCR, MENU and LIVE buttons to switch to the desired mode on monitor 1 (see below for further information). When the power is restored after having already used the unit, the unit will restart in the modes selected before the unit was turned off.
LIVE picture mode VCR playback mode LIVE picture mode Menu mode
010101 020202
040404
070707
When the power on
050505 060606
080808
030303
090909
010101 020202
040404
070707
080808
VCR
030303
050505 060606
090909
Live Picture Mode (see page 10)
When the LIVE button is pressed, the live (direct) picture from the cameras connected to the camera input terminals (1 – 9) on the unit rear panel, will be displayed on monitor 1. While in live picture mode you can use the still and zoom functions.
NOTE:
The unit will automatically start in the live picture or VCR
playback display mode (9, 4 divisions split screen, full screen or sequential display) last selected. Therefore, when a mode is selected, the display mode will remain the same.
If a camera is not connected at one of the input terminals,
NO VIDEO will be displayed on the monitor 1 screen.
010101 020202
040404
070707
080808
050505 060606
030303
090909
(LANGUAGE/LANG./SPRACHE)
ENGLISH
FRANCAIS
DEUTSCH
MENULIVE
Menu Setting Mode (see page 25)
1 Press the MENU button to display the menu.
The buttons used for menu control are indicated below.
3
21
SEQUENCE
MENU
NEXT
EXIT
DISPLAY
4
+
5
ALL
RESET
MENU
RESET
MULTI LIVE VCR
ZOOM STILL
NO VIDEO
VCR Playback Mode (see page 18)
Start playback on the VCR. If the video signal is correctly recorded, the VCR playback image will be displayed on monitor 1 when the VCR button is pressed. While in VCR playback mode you can use the still and zoom functions.
NOTE: If playing back a tape not recorded through this unit, NO
ID will be displayed on the monitor screen.
NO ID
NOTE: In live picture mode and VCR playback mode there
may be a slight vertical roll of the picture.
2 NEXT button
To select a sub-menu (in the (CAMERA SET), (POSITION SET), (DISPLAY SET) menus) in order to set the title position, etc. Press the NEXT button to switch between the menu and the sub-menu.
3 j, l, c, d buttons...press repeatedly
j button: will move the cursor up.
l button: will move the cursor down.
c button: will move the cursor towards the right.
d button: will move the cursor towards the left.
4 EXIT/DISPLAY button (see page 9)
To exit the menu mode and return to live picture mode. Also, when in live picture mode or VCR playback mode, press
this button to switch the display of the camera title and the clock display on/off.
5 +, – buttons...press repeatedly
+ button: for forward selection of numbers, letters,
button: for backward selection of numbers, letters,
symbols.
symbols.
8 English
Page 10
BASIC OPERATIONS
y
SECURITY LOCK FUNCTION
This function lets you lock the camera live picture mode or VCR playback mode, so that it cannot be switched to another mode.
Camera Live Picture Mode Lock
Press the LIVE button for about 3 seconds.
A buzzer will be heard, and the VCR and MENU buttons will not operate if pressed. If buttons are pressed, a buzzer will be heard and the operation will not be possible.
LIVE
VCR Playback Mode Lock
Press the VCR button for about 3 seconds.
A buzzer will be heard, and the LIVE and MENU buttons will not operate if pressed. If buttons are pressed, a buzzer will be heard and the operation will not be possible.
VCR
VCR MENU
LIVE MENU
RESET FUNCTION
The menus can be reset or cleared using one of the following two methods.
SEQUENCE
MENU
NEXT
EXIT
DISPLAY
+
RESET
MENU RESET
ALL
PLUS QUAD MULTI LIVE VCR
MON 2 ZOOM STILL
Using the ALL RESET button
Press this button to reset the following:
Reset the time and date in the (CLOCK SET) menu to the
default setting.
The display mode on monitor 1 will return to 9 divisions split
screen (default mode).
The display mode on monitor 2 will return to sequential
screen (default mode).
The information about the alarms displayed in the (ALARM
DATA) menu will be erased.
Canceling the Security Lock
To cancel the security lock, press the same button again for about 3 seconds. A buzzer will be heard and the mode will be unlocked.
SETTINGS BACKUP FUNCTION
This unit bottom is equipped with a backup battery (lithium battery) to maintain the clock settings. When the unit is used under normal conditions, the backup battery is recharged. The battery is fully recharged after a minimum of about 30 hours, and will maintain the clock settings for up to 30 days.
NOTE: The settings may not be maintained properly if the
backup battery has been recharged for less than 30 hours when the power goes off.
Battery Life
If the power is turned off for about one hour or more, when the power is restored, the (CLOCK SET) menu is displayed so the clock settings can be checked.
If the clock settings are reset to: 01-01-2000 SAT 00:00:00, that may indicate that the battery is dead and must be replaced.
Replacing the Battery
To replace the battery, please consult your dealer. After the battery has been replaced, press the ALL RESET button, then in the (CLOCK SET) menu set the date and time (see page 27).
Depending on the battery usage it may become necessary to change it. For replacement and disposal of the old battery, please contact your dealer.
NOTE: If the unit does not function properly, press the
ALL RESET button.
Please note that all the settings mentioned above will be reset.
Using the MENU RESET Button
A: While a menu is displayed, press the MENU RESET button to
reset all the values of the displayed menu to the default values.
B: If no menu is displayed, press the MENU RESET button to
reset the time to the nearest hour.
NOTE: For example, between 10:30:00 and 11:29:59 the
clock will be reset to 11:00:00.
Clock, title display operations
Even if the clock and title displays are turned off in the (DISPLAY SET) menu, the display mode can be selected as indicated below by pressing the EXIT/DISPLAY button. Also, when the clock is displayed, its position can be changed by pressing the j (or l) button.
Date and time display:
Title display:
Date and time and title display:
15-10-1999 15:40:00
HALL-1F
15-10-1999 15:40:00 HALL-1F
No displa
English 9
Page 11
LIVE PICTURE MODE
S 04
SZ 04
Z 04
SZ 04
03
04
01
02
05
06
06
03
04
01
02
LIVE
Press the LIVE button.
The live pictures from the cameras connected to the CAMERA IN terminals on the unit back panel will be displayed on monitor 1.
Refer to the diagrams below for the buttons to press in order to select the desired operation mode.
The video signal is output at the VCR OUT terminal on the back panel, for recording purposes.
Please refer to (VCR SET) for more information (see page 29).
Live picture mode operations steps on monitor 1
Full screen operations (see page 12)
(Full screen) (Still image) (Zoomed in still image)
4
040404 S 04
STILL
ZOOM
S 04 SZ 04
(Zoom range setting)
4
SZ 04
4
Press for 2 seconds or more
ZOOM
SEQUENCE
4 divisions split screen operations (see page 14)
(4 divisions split screen: 1 - 4) (4 divisions split screen: 5 - 8) (4 divisions split screen: 9)
QUAD QUAD
01 02
01
03
03 04
02
04
Press for 2 seconds
(Zoomed in image)
Z 04
Z 04
(Automatic sequential
display)
040404
QUAD
05 06
05
070707
06
080808
or more
STILL
(Zoomed in still image)
SZ 04
SZ 04
QUAD
090909
(Automatic sequential display)
SEQUENCE
01
01 02
03
03 04
070707
02
06
06
04
080808
10 English
Page 12
LIVE PICTURE MODE
04
07
01 02 03
04 05 06
07 08 09
01 02 03
04 05 06
07 08 09
02
02
01
09
01
04
02
01
Multi-display screen operations (see page 15)
9 divisions split screen
MULTI
010101 020202 030303
04 050505 060606
04
07 080808 090909
07
Plus-display screen operations (see page 15)
PLUS
6 divisions plus split screen
01 02
04
07
010101
03
VCR
9
SEQUENCE
2
SEQUENCE
01 02
04
07
01 02
04
07
01 02
04
07
01 02
04
07
03
090909
03
010101
020202
03
020202
03
010101
020202
Live picture mode operations steps on monitor 2 (see page 17)
Monitor 1 Monitor 2
010101
020202
030303
040404
050505 060606
080808
070707
090909
(Full screen)
010101
or
(Automatic sequential
display)
010101
MON 2
MON 2
SEQUENCE
4
(Automatic sequential display)
010101
(Full screen)
4
04
04
English 11
Page 13
FULL SCREEN OPERATIONS Live picture mode
1
2
2
...
0202 S 02S 02
STILL
8
9
Press a SELECT (1 – 9) button.
The live pictures from the selected camera will be displayed full screen.
Example: To freeze the image from camera 2
1 Press the SELECT 2 button.
The camera 2 indicator lights, the image from camera 2 is displayed full screen.
2 Press the STILL button.
The STILL indicator flashes and “S flashes on-screen. NOTE: When a still image is displayed, press the ZOOM button for a zoomed in
still image. To return to normal still image display, press the ZOOM button one more time.
To cancel the still image display mode
Press the STILL button. If another mode button is pressed, the still image display mode is cancelled and
the selected mode starts.
Example: To zoom in the image from camera 3
0303 Z 03Z 03
ZOOM
3
1 Press the SELECT 3 button.
The camera 3 indicator lights, the image from camera 3 is displayed full screen.
2 Press the ZOOM button.
The ZOOM indicator flashes and “Z flashes on-screen. NOTE: The zoomed in area will be as set by the zoom range frame.
To cancel the zoomed in image display mode
Press the ZOOM button. If another mode button is pressed, the selected mode starts.
12 English
Page 14
FULL SCREEN OPERATIONS Live picture mode
Z 04
Z 04
Z 04
Z 04
Example:
To zoom in the image from camera 4 and set the zoom range
1 2
040404
ZOOM
4
Z 04
Z 04
You can select the portion of the image to zoom in. The default zoomed in area is the centre of the image, but if a different zoom range is selected it will be memorized until changed or cancelled.
1 Press the SELECT 4 button.
The camera 4 indicator lights, the image from camera 4 is displayed full screen.
2 Press the ZOOM button.
3
The ZOOM indicator flashes and “Z flashes on-screen.
3 Press the SELECT 4 button for about 2 seconds.
Z 04
Z 04
4
4
The zoomed in image will switch to the normal display mode, and the zoom range frame is displayed.
NOTE: If the zoom range frame is not moved for about 10 seconds, the display
will automatically return to zoomed in mode. To display the zoom range frame again, press the SELECT 4 button for about 2 seconds.
4 Press the j, l, d or c button repeatedly to move the zoom range frame to
Z 04
Z 04
the desired area of the image.
5 Press the SELECT 4 button.
The area selected by the zoom range frame is now zoomed in. If necessary, follow the same procedure to set the zoom range for the other cameras.
5
Z 04
Z 04
4
To cancel the zoomed in image display mode
Press the ZOOM button. If another mode button is pressed, the selected mode starts.
While in zoomed mode, if the SELECT button is pressed one more time, depending on the movement of the subject, the image may be more or less clear. Pressing the SELECT button repeatedly will produce the following according to the image conditions.
Image with little or no movement (close to a still image)
The image of still objects will be clear, the picture quality of moving areas of the image will be coarse.
Image with normal movement (people or vehicles)
The moving objects in the image will be clear, the picture quality of areas of the image with little movement will be coarse.
Example: To freeze the zoomed in image from camera 2
1 Press the SELECT 2 button.
2
0202 Z 02Z 02
STILL
ZOOM
The camera 2 indicator lights, the image from camera 2 is displayed full screen.
2 Press the ZOOM button.
The image from camera 2 is zoomed in, and “Z flashes on-screen.
3 Press the STILL button.
SZ 02SZ 02
The STILL indicator flashes and the ZOOM indicator lights. The camera 2 zoomed in image is frozen, and SZ flashes on-screen.
To cancel the still and zoomed in image display modes
Press the STILL button, then press the ZOOM button. If another mode button is pressed, the selected mode starts.
English 13
Page 15
FULL SCREEN OPERATIONS Live picture mode
03
04
01
02
05
06
03
04
01
02
05
06
03
04
01
02
Automatic sequential full screen display
Press the SEQUENCE button.
The SEQUENCE indicator flashes. The pictures from each camera are displayed sequentially full screen, on monitor 1, according to the monitor 1 sequential mode and speed set in the (MONITOR SET) menu (see page 35). The camera SELECT
SEQUENCE
010101
010101
indicators (1 – 9) light sequentially according to the displayed camera.
To cancel the sequential display mode
Press the SEQUENCE button or the SELECT button.
4 DIVISIONS SPLIT SCREEN OPERATIONS
Live picture mode
01
01 02
03
03 04
QUAD
01
01 02
03
03 04
02
04
SEQUENCE
QUAD
Press the QUAD button.
The 4 divisions split screen display mode will be selected.
Switching the 4 divisions split screen
02
04
05 06
05
070707
06
Press the QUAD button.
080808
Every time the QUAD button is pressed a 4 divisions split screen (1 - 4, 5 - 8, 9) is selected. The camera SELECT indicators light according to the displayed cameras.
Automatic sequential 4 divisions split screen display
01
01 02
03
03 04
02
05
05 06
04
070707
06
080808
Press the SEQUENCE button.
The SEQUENCE indicator flashes. The 4 divisions split screens are displayed sequentially according to the 4 divisions split screen sequential mode and speed set in the (MONITOR SET) menu (see page 35). The camera SELECT indicators (1 - 4, 5
- 8, 9) light sequentially according to the displayed 4 divisions split screen.
To cancel the sequential display mode
Press the SEQUENCE button or the SELECT button.
14 English
Page 16
MULTI-DISPLAY SCREEN OPERATIONS
04
07
Live picture mode
MULTI
010101 020202 030303
04
04 050505 060606
07
07 080808 090909
Press the MULTI button.
The 9 divisions split screen display mode will be selected. NOTE: The display position of each camera within the 9 divisions split screens can
be set as desired (see page 43).
PLUS-DISPLAY SCREEN OPERATIONS
Live picture mode
PLUS
01 02
04
07
03
010101
Press the PLUS button.
The PLUS indicator flashes. The 6 divisions plus screen display mode will be selected. (The plus-display will appear in the bottom right corner of the screen.)
01 02
04
07
9
Example: To display the image from camera 9 in the plus
03
Press the SELECT 9 button.
010101
090909
The camera 9 indicator lights, the image from camera 9 is displayed in the plus screen area.
screen area
To cancel the plus display mode
Press the PLUS button.
English 15
Page 17
PLUS-DISPLAY SCREEN OPERATIONS Live picture mode
Automatic sequential plus display
01 02
04
07
SEQUENCE
01 02
04
07
VCR
01 02
04
07
VCR
010101
03
010101
2
010101
SEQUENCE
03
Press the SEQUENCE button.
The SEQUENCE indicator flashes. The pictures from each camera are displayed sequentially in the plus screen area, on monitor 1, according to the monitor 1
010101
020202
sequential mode and speed set in the (MONITOR SET) menu (see page 35). The camera SELECT indicators (1 – 9) light sequentially according to the displayed camera.
To cancel the sequential display mode
Press the SEQUENCE button.
Example: To display the recorded image from camera 2 in
the plus screen area
1 Press the VCR button.
The VCR indicator flashes and, the VCR tape playback image is displayed in the
020202
plus screen area.
2 Press the SELECT 2 button.
The camera 2 indicator lights, the image from camera 2 is displayed in the plus screen area.
Automatic sequential plus display of recorded pictures
03
010101
020202
1 Press the VCR button.
The VCR indicator flashes and the VCR tape playback image is displayed in the plus screen area.
2 Press the SEQUENCE button.
The SEQUENCE indicator flashes, and the recorded pictures are displayed sequentially in the plus screen area, on monitor 1, according to the monitor 1 sequential mode and speed set in the (MONITOR SET) menu (see page 35). The camera SELECT indicators (1 – 9) light sequentially according to the displayed camera.
To cancel the automatic sequential plus display
To cancel the sequential display mode, press the SEQUENCE button.
To cancel the plus display mode, press the PLUS button.
16 English
Page 18
MONITOR 2 OPERATIONS
04
07
04
07
Live pictures will be displayed on monitor 2 even during VCR playback mode
Live picture mode
Monitor 1
010101 020202 030303
04
04 050505 060606
07 080808 090909
07
MON 2
Monitor 2
4
Monitor 2
Press the MON 2 button.
The MON 2 indicator will flash, and the live pictures display mode on monitor 2 can be set. The available display modes are full screen or full screen automatic sequential display.
Example: To display full screen the image from camera 4
on monitor 2
Press the SELECT 4 button.
The camera 4 indicator lights, the image from camera 4 is displayed full screen.
010101
040404
Monitor 1
010101 020202 030303
04 050505 060606
04
07 080808 090909
07
Monitor 2
To switch the display mode on monitor 2 from full screen to full screen automatic sequential display
Press the SEQUENCE button.
The SEQUENCE indicator flashes and the pictures from each camera are displayed sequentially full screen, on monitor 2, according to the monitor 2 sequential mode and
010101
SEQUENCE
speed set in the (MONITOR SET) menu (see page 35).
To cancel the sequential display mode and the monitor 2 display settings
Press the SEQUENCE button, then press the MON 2 button.
Monitor 2
TO DISPLAY ON MONITOR 2 THE SAME IMAGE AS ON MONITOR 1
010101
Press the MON 2 button.
This function can be used to monitor the images from a second location. In the (MONITOR SET) menu, set the item MON2 MON1 to ON (see page 35).
NOTE: When this setting is used, the MON 2 button will not be operate.
English 17
Page 19
VCR PLAYBACK MODE
S 04
SZ 04
Z 04
SZ 04
03
04
01
02
05
06
06
03
04
01
02
VCR
Press the VCR button.
The VCR playback display mode is selected. When a tape is played back, the recording of the live pictures will be displayed on monitor 1.
During VCR playback mode, if a second VCR is connected to the VCR OUT terminal, live pictures can be recorded.
VCR playback mode operations steps on monitor 1
Full screen operations (see page 20)
(Full screen) (Still image) (Zoomed in still image)
4
040404 S 04
STILL
S 04 SZ 04
ZOOM
4
Press for 2 seconds
or more
SZ 04
4
Press for 2 seconds or more
(Zoom range setting)
ZOOM
SEQUENCE
4 divisions split screen operations (see page 22)
(4 divisions split screen: 1 - 4) (4 divisions split screen: 5 - 8) (4 divisions split screen: 9)
QUAD QUAD
01 02
01
03
03 04
02
04
(Automatic sequential display)
(Zoomed in image)
Z 04
Z 04
(Automatic sequential
display)
040404
QUAD
05 06
05
070707
06
080808
STILL
(Zoomed in still image)
SZ 04
SZ 04
QUAD
090909
SEQUENCE
01
01 02
03
03 04
070707
02
06
06
04
080808
18 English
Page 20
VCR PLAYBACK MODE
04
07
01 02 03
04 05 06
07 08 09
02
01
04
09
01 02 03
04 05 06
07 08 09
01
Multi-display screen operations (see page 23)
9 divisions split screen
MULTI
Plus-display screen operations (see page 23)
PLUS
010101 020202 030303
04 050505 060606
04
07 080808 090909
07
6 divisions plus split screen
01 02
04
03
9
01 02
04
07
03
090909
07
010101
SEQUENCE
01 02
04
07
03
010101
020202
VCR playback mode operations steps on monitor 2 (see page 17)
When the VCR button is pressed, the recorded pictures are displayed on monitor 1 and live pictures will be displayed on monitor 2.
Monitor 1: Recorded pictures Monitor 2: Live pictures
010101
020202
050505 060606
080808
030303
090909
040404
070707
(Full screen)
010101
MON 2
(Automatic sequential display)
SEQUENCE
010101
or
(Automatic sequential
display)
010101
English 19
MON 2
(Full screen)
4
04
04
4
Page 21
FULL SCREEN OPERATIONS VCR playback mode
1
2
2
...
0202 S 02S 02
STILL
8
9
Press a SELECT (1 – 9) button.
The recorded pictures from the selected camera will be displayed full screen.
Example: To freeze the recorded image from camera 2
1 Press the SELECT 2 button.
The camera 2 indicator lights, the recorded image from camera 2 is displayed full screen.
2 Press the STILL button.
The STILL indicator flashes and “S flashes on-screen. NOTE: When a still image is displayed, press the ZOOM button for a zoomed in
still image. To return to normal still image display, press the ZOOM button one more time.
To cancel the still image display mode
Press the STILL button. If another mode button is pressed, the still image display mode is cancelled and
the selected mode starts.
Example: To zoom in the recorded image from camera 3
0303 Z 03Z 03
ZOOM
3
1 Press the SELECT 3 button.
The camera 3 indicator lights, the recorded image from camera 3 is displayed full screen.
2 Press the ZOOM button.
The ZOOM indicator flashes and “Z flashes on-screen. NOTE: The zoomed in area will be as set by the zoom range frame.
To cancel the zoomed in image display mode
Press the ZOOM button. If another mode button is pressed, the selected mode starts.
20 English
Page 22
FULL SCREEN OPERATIONS VCR playback mode
Z 04
Z 04
Z 04
Z 04
Example:
To zoom in the recorded image from camera 4 and set the zoom range
1 2
040404
ZOOM
4
Z 04
Z 04
3
Z 04
Z 04
4
4
Z 04
Z 04
You can select the portion of the image to zoom in. The default zoomed in area is the centre of the image, but if a different zoom range is selected it will be memorized until changed or cancelled.
1 Press the SELECT 4 button.
The camera 4 indicator lights, the recorded image from camera 4 is displayed full screen.
2 Press the ZOOM button.
The ZOOM indicator flashes and “Z flashes on-screen.
3 Press the SELECT 4 button for about 2 seconds.
The zoomed in image will switch to the normal display mode, and the zoom range frame is displayed.
NOTE: If the zoom range frame is not moved for about 10 seconds, the display
will automatically return to zoomed in mode. To display the zoom range frame again, press the SELECT 4 button for about 2 seconds.
4 Press the j, l, d or c button repeatedly to move the zoom range frame to
the desired area of the image.
5 Press the SELECT 4 button.
The area selected by the zoom range frame is now zoomed in. If necessary, follow the same procedure to set the zoom range for the other cameras.
5
Z 04
Z 04
4
To cancel the zoomed in image display mode
Press the ZOOM button. If another mode button is pressed, the selected mode starts.
2
0202 Z 02Z 02
STILL
ZOOM
SZ 02SZ 02
Example: To freeze the zoomed in recorded image from
camera 2
1 Press the SELECT 2 button.
The camera 2 indicator lights, the recorded image from camera 2 is displayed full screen.
2 Press the ZOOM button.
The recorded image from camera 2 is zoomed in, and “Z flashes on-screen.
3 Press the STILL button.
The STILL indicator flashes and the ZOOM indicator lights. The camera 2 zoomed in image is frozen, and SZ flashes on-screen.
To cancel the still and zoomed in image display modes
Press the STILL button, then press the ZOOM button. If another mode button is pressed, the selected mode starts.
English 21
Page 23
FULL SCREEN OPERATIONS VCR playback mode
03
04
01
02
05
06
03
04
01
02
05
06
03
04
01
02
Automatic sequential full screen display
Press the SEQUENCE button.
The recorded pictures from each camera are displayed sequentially full screen, on monitor 1, according to the monitor 1 sequential mode and speed set in the (MONITOR SET) menu (see page 35). The camera SELECT indicators (1 – 9) light
SEQUENCE
010101
010101
sequentially according to the displayed camera.
To cancel the sequential display mode
Press the SEQUENCE button one more time.
NOTE: If the sequential display speed set in the (MONITOR SET) menu is faster than
the tape playback speed, the images will not be displayed correctly. The sequential screen display mode will be the same in 4 divisions split screen and in plus screen display modes.
4 DIVISIONS SPLIT SCREEN OPERATIONS
VCR playback mode
01 02
01
03
03 04
QUAD
01
01 02
03
03 04
02
04
SEQUENCE
QUAD
Press the QUAD button.
The recorded images 4 divisions split screen display mode is selected.
Switching the 4 divisions split screen
02
04
05 06
05
070707
06
Press the QUAD button.
080808
Every time the QUAD button is pressed a 4 divisions split screen (1 - 4, 5 - 8, 9) is selected. The camera SELECT indicators light according to the displayed cameras.
Automatic sequential 4 divisions split screen display
01
01 02
03
03 04
02
05
05 06
04
070707
06
080808
Press the SEQUENCE button.
The 4 divisions split screens are displayed sequentially according to the 4 divisions split screen sequential mode and speed set in the (MONITOR SET) menu (see page
35). The camera SELECT indicators (1 - 4, 5 - 8, 9) light sequentially according to the displayed 4 divisions split screen.
To cancel the sequential display mode
Press the SEQUENCE button one more time.
22 English
Page 24
MULTI-DISPLAY SCREEN OPERATIONS
04
07
VCR playback mode
MULTI
010101 020202 030303
04
04 050505 060606
07
07 080808 090909
Press the MULTI button.
The recorded images 9 divisions split screen display mode will be selected. NOTE: The display position of each camera within the 9 divisions split screens can
be set as desired (see page 43).
PLUS-DISPLAY SCREEN OPERATIONS
VCR playback mode
PLUS
01 02
04
07
03
010101
Press the PLUS button.
The recorded images 6 divisions plus screen display mode will be selected. (The plus-display will appear in the bottom right corner of the screen.)
NOTE: During VCR playback mode, a live picture cannot be displayed in the plus
screen area.
01 02
04
07
9
Example: To display the recorded image from camera 9 in
03
Press the SELECT 9 button.
010101
090909
The camera 9 indicator lights, the recorded image from camera 9 is displayed in the plus screen area.
the plus screen area
To cancel the plus display mode
Press the PLUS button.
English 23
Page 25
PLUS-DISPLAY SCREEN OPERATIONS VCR playback mode
Automatic sequential plus display
01 02
04
07
SEQUENCE
03
Press the SEQUENCE button.
The recorded pictures from each camera are displayed sequentially in the plus screen area, on monitor 1, according to the monitor 1 sequential mode and speed set in the
010101
010101
020202
(MONITOR SET) menu (see page 35). The camera SELECT indicators (1 – 9) light sequentially according to the displayed camera.
To cancel the sequential plus display
To cancel the sequential display mode, press the SEQUENCE button.
To cancel the plus display mode, press the PLUS button.
24 English
Page 26
MENU SETTING MODE
04
07
04
07
MENUS DISPLAYS
To display the menus, press the MENU button.
(Monitor 1)
010101 020202 030303
04 050505 060606
04
07
07 080808 090909
EXIT
MENU
Menu 1
(LANGUAGE/LANG./SPRACHE)
ENGLISH
FRANCAIS
DEUTSCH
MENU
Menu 2
(CLOCK SET) 01-01-2000 SAT 00:00:00
(TIMER SET) DAYTIME 00:00-00:00
(SUMMER TIME SET) MODE NO USE WEEK MON TIME ON LST-SUN 03 02:00 OFF LST-SUN 10 02:00
MENU
Menu 3
(VCR SET) VCR MODE TLS REC SPEED 3 H ALARM REC SPEED 3 H PROGRAM REC MODE OFF
(SERIAL SET) DATA SPEED 19200 ALARM SEND OFF ööADDRESS:000öö
MENU
Menu 4
(ALARM SET) DURATION 10 S RETRIGGER OFF BUZZER ON DATA ON MON.1 OUT FULL DOUBLE ALARM LAST MON.2 OUT OFF (SENSOR SET) SENSOR ALARM OFF DURATION 10 S
MENU
Menu 5
(ACTIVE REC SET) EXT ALARM REC OFF SENSOR REC OFF REC MODE MODE2
(VIDEO LOSS SET) VIDEO LOSS OFF DISPLAY FREEZE DATA ON
MENU
Menu 6
(MONITOR SET)
MON1 SEQ.TIMER 1 S MON2 SEQ.TIMER 1 S QUAD SEQ.TIMER 1 S MON1 SEQ.MODE MODE1 MON2 SEQ.MODE MODE1 MON2 í MON1 OFF MON.MASK LIVE ON MON.MASK VCR ON COLOR LEVEL AUTO
MENU
Menu 7
(CAMERA SET) NO.01 TITLE
DAY NIGHT PROGRAM REC OFF OFF
MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
--------
MENU
Menu 8
(POSITION SET)
MULTI 9
01 02 03 04 05 06 07 08 09
MENU
Menu 9
(DISPLAY SET)
LIVE CLOCK OFF TITLE ON VCR PB CLOCK OFF TITLE ON
TITLE POSITION DOWN
CLOCK POSITION SET † PRESS NEXT
MENU
Menu 10
(ALARM DATA) 1/ 1 CAM DATE TIME ITEM
Menu display
01
----------------
----------------
----------------
----------------
----------------
----------------
----------------
NEXT
----------------
----------------
----------------
LEVEL:DAY†OFF NIGHT†OFF MODE:A
NEXT
01-01-2000 00:00:00
ñ
English 25
MENU
010101 020202 030303
04 050505 060606
04
07
07 080808 090909
Live picture display
Page 27
LANGUAGE SETTING Menu 1
(LANGUAGE/LANG./SPRACHE)
The default menu language is English. The available language settings are English, French and German.
Setting the language
1 Press the MENU button once to display the
(LANGUAGE/LANG./SPRACHE) menu.
2 Press the l button to highlight the desired language. 3
Press the MENU button to go to the next menu, or
Press the EXIT button to exit the menu display and
the selected language is set.
All the on-screen menus and settings will be displayed in the selected language.
(LANGUAGE/LANG./SPRACHE)
ENGLISH
FRANCAIS
DEUTSCH
MENU
(HORLOGE) 01-01-2000 SAM 00:00:00
(PROGRAMMATEUR) JOUR 00:00-00:00
(HEURE ETE) MODE NON SEM. MOIS HEURE MAR DER-DIM 03 02:00 ARR DER-DIM 10 02:00
(UHRZEIT) 01-01-2000 SA 00:00:00
(TIMER EINST.) TAGESZEIT 00:00-00:00
(SOMMERZEIT EINST.) ART AUS WOCHE MT ZEIT EIN LZT-SO 03 02:00 AUS LZT-SO 10 02:00
26 English
Page 28
CLOCK AND SUMMER TIME SETTING
Menu 2
(CLOCK SET)
The default setting is as indicated below. The clock will start after the actual time and date are set and the operations under (TIMER SET) are completed.
Default clock settings: 01-01-2000 SAT 00:00:00
(January 1, 2000 at 00:00)
1 Press the MENU button twice to display the (CLOCK
SET) menu.
2 Example: Setting the clock to October 15, 1999 at 3:20 PM
1 Press the + (or –) button to set the day (15), then press
the c button.
2 Press the + (or –) button to set the month (10), then
press the c button.
3 Press the + (or –) button to set the year (1999), then
press the c button.
4 Press the + (or –) button to set the hours (15), then press
the c button.
5 Press the + (or –) button to set the minutes (20), then
press the c button.
NOTE: The day of the week (FRI) will be automatically set
according to the date entered.
3
Press the l button to go to (TIMER SET).
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
2-
1
(CLOCK SET) 15-01-2000 SAT 00:00:00
2-
2~5
(CLOCK SET) 15-10-1999 FRI 15:20:00
(TIMER SET)
You can set a DAY and a NIGHT range for the 24 hour day period, in order to set each camera mode and programmed recording accordingly.
1 Set the daytime period start and end time. 2 Example: Day period from 7:30 AM to 7:30 PM
Night period from 7:30 PM to 7:30 AM
1 Using the + (or –) button, select (7) for the starting hour
of the DAYTIME period, then press the c button.
2 Using the + (or –) button, select (30) for the starting
minutes of the DAYTIME period, then press the c button.
NOTE:
The times for the day period only need to be set. The
night period will be automatically set accordingly.
If the day start and end time are the same, the DAYTIME
settings will be active 24 hours a day.
3
Press the MENU button to go to the next menu
screen, or
Press the EXIT button to exit the menu display.
3
(CLOCK SET) 15-10-1999 FRI 15:20:00
(TIMER SET) DAYTIME 07:30-19:30
(SUMMER TIME SET) MODE NO USE WEEK MON TIME ON LST-SUN 03 02:00 OFF LST-SUN 10 02:00
End time Start time
NOTE: To set the display mode for the clock, refer to
DISPLAY SET (CLOCK, TITLE) on page 44.
English 27
Page 29
CLOCK AND SUMMER TIME SETTING Menu 2
(SUMMER TIME SET)
The default summer time function setting is NO USE, so the summer adjustment will not be made.
If the unit will be used in an area where there is a summer time change, set it to USE, then if necessary, set when the summer time is changed.
The default settings are:
Summer time from the last Sunday of March, at 2:00 AM (LST-SUN 03 02:00) to last Sunday of October, at 2:00 AM (LST-SUN 10 02:00).
TO MAKE CHANGES TO THE SETTINGS
1 Press the l button to highlight the NO USE setting,
then press the + (or –) button to select “USE”, and press the l button one more time.
2 Example: Setting the summer time from the second
Tuesday of May at 3:00 AM, to the fourth Tuesday of September at 3:00 AM.
1 Press the + (or –) button to set the WEEK (2ND), then
press the c button. Menu: 1ST, 2ND, 3RD, 4TH or LST (first, second, third,
fourth or last)
2 Press the + (or –) button to set the WEEK (TUE), then
press the c button. Menu: SUN, MON, TUE, WED, THU, FRI or SAT
3 Press the + (or –) button to set the MON (05), then press
the c button.
Menu: 1, 2, 3, 4 ..... 11, 12
(for January, February, March ..... December)
4 Press the + (or –) button to set the TIME (03), then press
the l button. Following the same procedure as above, set when the
time is changed back from summer time to standard time (the OFF settings).
3
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
12-
(SUMMER TIME SET) MODE USE WEEK MON TIME ON LST-SUN 03 02:00 OFF LST-SUN 10 02:00
2-
2
(SUMMER TIME SET) MODE USE WEEK MON TIME ON 2ND-TUE 03 02:00 OFF LST-SUN 10 02:00
2-
4
(SUMMER TIME SET) MODE USE WEEK MON TIME ON 2ND-TUE 05 03:00 OFF LST-SUN 10 02:00
1
(SUMMER TIME SET) MODE USE WEEK MON TIME ON 2ND-SUN 03 02:00 OFF LST-SUN 10 02:00
2-
3
(SUMMER TIME SET) MODE USE WEEK MON TIME ON 2ND-TUE 05 02:00 OFF LST-SUN 10 02:00
28 English
Page 30
VCR SETTING AND EXTERNAL CONTROL COMMUNICATION SPEED SETTING Menu 3
(VCR SET)
You must set this unit output to match the type (Timelapse or Real time VCR) and settings of the VCR used for recording.
Setting the VCR Output
1 Press the MENU button 3 times to display the (VCR
SET) menu.
2 Using the + (or –) button, select the desired “VCR
MODE setting, then press the l button. Following this procedure, select the settings for REC
SPEED, ALARM REC SPEED and PROGRAM REC MODE.
3
VCR MODE
TLS: If using a timelapse VCR. (Default setting) REAL: If using a real time VCR.
REC SPEED
The recording speed settings on this unit correspond to recording durations on a E-180 tape.
With a timelapse VCR
Set the recording speed to match the recording speed of the timelapse VCR.
The available speeds are: 3 (3H) (Default setting), 12 (12H), 24 (24H), 48 (48H), 72 (72H), 96 (96H), 120, 168, 240, 360, 480, 720, 960 (960H)
With a real time VCR
Set the recording speed to match the recording speed of the real time VCR.
The available speeds are: 6 (6H) (Default setting), 18 (18H), 30 (30H), 48 (48H), 72 (72H), 96 (96H), 120, 168, 240, 360 , 480, 720, 960 (960H)
NOTE: Real time VCRs speed is based on a E-240 cassette
Press the l button to go to the (SERIAL SET) menu,
or Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
(Timelapse VCR) (Real time VCR)
2
(VCR SET) VCR MODE TLS REC SPEED 3 H ALARM REC SPEED 3 H PROGRAM REC MODE OFF
VIDEO LOSS ON DATA ON DISPLAY FREEZE <RS232C SET>
(VCR SET) VCR MODE REAL REC SPEED 6 H ALARM REC SPEED 6 H PROGRAM REC MODE OFF
VIDEO LOSS ON DATA ON DISPLAY FREEZE <RS232C SET>
VCR SET menu
If the VCR is not Equipped with a SW (switching) Output Connector
tape. When setting this unit to 6H, 18H or 30H, refer to the table 1 for the speed correspondence, and select the speed on the VCR accordingly.
Table 1
REC SPEED setting
6 (6H) 8H (8-hour mode) 18 (18H) 24H (24-hour mode) 30 (30H) 40H (40-hour mode)
Recording speed setting on the
real time VCR
ALARM REC SPEED
With a timelapse VCR
Set the recording speed to use when an alarm trigger is received to match the alarm recording speed of the timelapse VCR.
The available speeds are:
3 (3H) (Default setting), 12 (12H), 24 (24H), NC, F3
When an alarm trigger is received, the recording speed is not
NC:
changed and stays as set under REC SPEED”.
F3: Use this setting when using the SW output terminal on a timelapse
VCR that does not output a switching signal in 3H mode.
With a real time VCR
Set the recording speed to use when an alarm trigger is received to match the alarm recording speed of the real time VCR.
The available speeds are:
6 (6H) (Default setting), 18 (18H), NC, F6
NC: When an alarm trigger is received, the recording speed is
not changed and stays as set under REC SPEED”.
F6: Use this setting when using the SW output terminal on a real
time VCR that does not output a switching signal in 6H mode.
PROGRAM REC MODE (Default setting: OFF)
Using the programmed recording mode you can decided to only output the recorded live pictures from a certain camera or to give priority to the pictures from a certain camera.
This will set the programmed recording mode.
MODE1:
MODE2: The live pictures from the camera for which programmed
OFF: Programmed recording will not be done. NOTE:
Only the live pictures from the camera for which programmed recording is set are recorded.
recording is set are recorded together with the live pictures from the other cameras.
Programmed recording of multiple cameras is done by switching to
each camera in order.
In the (CAMERA SET) menu, set for each camera if programmed
recording is to be conducted or not (see page 36).
The recording mode set here is the same as the ACTIVE REC
recording mode (see page 34). The programmed recording mode is the normal recording mode applied to the camera, while the active recording mode will modify the recording mode for the camera when an external alarm or a video sensor trigger is received.
Any camera for which programmed recording is turned off, will not be recorded when an external alarm or a video sensor trigger is received. To record from a camera for which programmed recording is turned off, when an external alarm or a video sensor trigger is received, set the active recording mode to on.
English 29
Page 31
VCR SETTING AND EXTERNAL CONTROL COMMUNICATION
)
SPEED SETTING Menu 3
If the VCR is Equipped with a SW (switching) Output Connector (using the VCR switching signal)
Make the connection from this unit to the VCR SW output connector. The video signal output by this unit will be automatically switched to the recording speed according to the switching signal output by the VCR (switching pulse setting on the VCR).
The (VCR SET) menu REC SPEED and ALARM REC
SPEED items do not need to be set. If a switching signal is not output at the switching terminal
Some VCR models may not output a switching signal in 3H or 6H mode. In such a case, make the settings as indicated in the table below.
VCR SET menu settings Timelapse VCR Real time VCR
REC SPEED ALARM REC SPEED
3 (3H) 6 (6H)
F3 F6
NOTE: When the recording speed is set to F3 or F6, the alarm
recording speed is fixed to 3H or 6H. Therefore, when using a recording speed other than 3H or 6H, do not use the F3 or F6 setting.
(SERIAL SET)
Connect the multiplexer to a computer, using a 9-pin D-SUB cable (sold separately), then set the maximum communication speed between the unit and the computer.
For detailed information, please refer to INTERFACE
SPECIFICATIONS on page 48.
Setting the RS232C/RS485 communication
1 Press the l button to highlight the setting to modify. 2 Using the + (or –) button, select the desired “DATA
SPEED setting, then press the l button.
3 Using the + (or –) button, select the desired “ALARM
SEND setting.
SERIAL SET menu
DATA SPEED (Default setting: 19200 bps)
The available settings are: 2400, 4800, 9600, 19200 bps
ALARM SEND (Default setting: OFF)
ON: The alarm information is output at the RS232C/RS485
terminals.
OFF: The alarm information is not output at the RS232C/RS485
terminals.
Unit address confirmation
If multiple units are going to be controlled through a system controller (sold separately) via the RS485 connection, each unit must have a address for remote control purposes. The address set for the unit can be checked by accessing the (VCR SET) menu.
1 Press the MENU button three times to display the (VCR
SET) menu.
The unit address is displayed on the last line of the menu. The unit address can be set using the Interface setting DIP
switches on the back panel of the unit. (see page 49)
2
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
1
(VCR SET) VCR MODE TLS REC SPEED 3 H ALARM REC SPEED 3 H PROGRAM REC MODE OFF
(SERIAL SET) DATA SPEED 19200 ALARM SEND OFF ööADDRESS:000öö
Address (000 – 127
(Interface setting DIP switches)
ON
12345678910
ON
OFF
4
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
2
(VCR SET) VCR MODE TLS REC SPEED 3 H ALARM REC SPEED 3 H PROGRAM REC MODE OFF
(SERIAL SET) DATA SPEED 19200 ALARM SEND OFF ööADDRESS:000öö
3
(VCR SET) VCR MODE TLS REC SPEED 3 H ALARM REC SPEED 3 H PROGRAM REC MODE OFF
(SERIAL SET) DATA SPEED 19200 ALARM SEND OFF ööADDRESS:000öö
30 English
Page 32
ALARM AND SENSOR SETTING Menu 4
(ALARM SET)
When an alarm trigger is received from sensors such as a door bell, movement sensor, etc. you can set the display mode and the recording mode for the pictures from the concerned camera.
Using the (SENSOR SET) settings (see page 32), the triggers received from the video sensors can be set to operate as alarm triggers.
Changing the Settings
1 Press the MENU button 4 times to display the (ALARM
SET) menu.
2 Using the + (or –) button, select the desired setting,
then press the l button.
Repeat step 2, until all the settings are as desired.
3
DURATION (Default setting: 10 S)
The available durations are (seconds):
CC: The alarm will go on as long as the alarm signal is
NC: The alarm will continue until reset. INDIV.:The alarm duration will be as set for each of the cameras. OFF: No alarm duration setting.
Press the l button to go to the (SENSOR SET)
menu, or Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
2
(ALARM SET) DURATION 10 S RETRIGGER OFF BUZZER ON DATA ON MON.1 OUT FULL DOUBLE ALARM LAST MON.2 OUT OFF (SENSOR SET) SENSOR ALARM OFF DURATION 10 S
ALARM SET menu
1, 2, 3, 4, 5, 10, 20 (in 10 seconds increments)... 180, CC, NC, INDIV., OFF
received (minimum 1 second).
NOTE: If the INDIV.” setting is used, in the (CAMERA SET)
menu, enter the desired alarm duration for each camera (see page 38).
(CAMERA SET) NO.01 TITLE
DAY NIGHT PROGRAM REC OFF OFF AL.DURATION 10 S 10 S MON.MASK OFF OFF
--------
01
DATA (Default setting: ON)
ON: The alarm data is recorded. OFF: The alarm data is not recorded.
MON.1 OUT
(A)
(ALARM SET) DURATION 10 S RETRIGGER OFF BUZZER ON DATA ON MON.1 OUT FULL DOUBLE ALARM LAST MON.2 OUT OFF (SENSOR SET) SENSOR ALARM OFF SENSOR DURATION 10 S
(B)
(ALARM SET) DURATION 10 S RETRIGGER OFF BUZZER ON DATA ON MON.1 OUT MULTI9
MON.2 OUT OFF
(C)
(ALARM SET) DURATION 10 S RETRIGGER OFF BUZZER ON DATA ON MON.1 OUT NC
MON.2 OUT OFF
(A) FULL (Default setting):
If an alarm trigger is received, the picture from the camera corresponding to the alarm input will be displayed full screen.
DOUBLE ALARM (Default setting: LAST)
When using the FULL setting at the MON.1 OUT line, the following settings are possible.
LAST: When triggers from multiple cameras are received in full screen mode, the picture from the camera of the last alarm received is displayed.
FIRST: When triggers from multiple cameras are received in full screen mode, the picture from the camera of the first alarm received only is displayed. Camera pictures from subsequent alarm triggers will not be displayed.
SWITCH: When triggers from multiple cameras are received in full screen mode, the picture from each concerned camera will be displayed sequentially at 1 second interval.
(B) MULTI9: When an alarm trigger is received, the display
will switch to a 9 divisions screen.
(C) NC: The display mode will remain unchanged when an
alarm trigger is received.
MON.2 OUT (Default setting: OFF)
ON: Monitor 2 display will switch to full screen alarm display,
when an alarm trigger is received.
OFF: Monitor 2 display will not change.
RETRIGGER (Default setting: OFF)
To set if an alarm is received while the unit is already in alarm mode.
ON: During alarm mode, other alarm triggers will be received
and the alarm duration will be extended.
OFF: The unit will not receive another alarm, while one is
already being received.
BUZZER (Default setting: ON)
ON: A buzzer will be heard when an alarm trigger is received. OFF: The buzzer will not be heard.
English 31
Page 33
ALARM AND SENSOR SETTING Menu 4
(SENSOR SET)
When the internal video sensor detects a movement in the live video signal, it can be set to trigger an alarm. Priority recording of the concerned pictures can also be set (ACTIVE REC).
Setting the SENSOR SET Mode
1 Press the l button to highlight the setting to modify. 2 Using the + (or –) button, select the desired “SENSOR
ALARM setting, then press the l button. Following this procedure, select the settings for “DURATION.
3
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
2
(ALARM SET) DURATION 10 S RETRIGGER OFF BUZZER ON DATA ON MON.1 OUT FULL DOUBLE ALARM LAST MON.2 OUT OFF (SENSOR SET) SENSOR ALARM OFF DURATION 10 S
SENSOR SET menu
SENSOR ALARM (Default setting: OFF)
This will set if the internal video sensor triggers are considered as alarm triggers.
ON: The sensor triggers will be considered as alarms, and
when received the display will switch to the selected alarm display mode and the buzzer will be heard.
OFF: The sensor triggers are not considered as alarms. AND: Only when a sensor trigger and an alarm trigger are
received simultaneously, it will be considered as an alarm.
NOTE: If SENSOR ALARM is set to AND, a trigger to an
ALARM IN terminal alone will not be considered as an
alarm.
DURATION (Default setting: 10 S)
When a video sensor detects a movement, this will set the active recording mode duration (see page 33).
The available durations are:
1, 2, 3, 4, 5, 10, 20 (in 10 seconds increments)... 180
NOTE: When the SENSOR ALARM settings ON” and AND
are used, the internal video sensor can trigger an alarm operation. The alarm duration is set by the DURATION setting in (ALARM SET) (see page 31).
32 English
Page 34
ACTIVE RECORDING AND VIDEO LOSS SETTING Menu 5
(ACTIVE REC SET)
To set the priority recording mode when an external alarm or video sensor trigger is received.
Setting the ACTIVE REC Recording Mode
1 Press the MENU button 5 times to display the (ACTIVE
REC SET) menu.
2 Using the + (or –) button select the desired “EXT
ALARM REC setting, then press the l button.
All the other settings are selected using the same procedure.
3
Press the l button to go to the (VIDEO LOSS SET)
menu, or Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
2
(ACTIVE REC SET) EXT ALARM REC OFF SENSOR REC OFF REC MODE MODE2
(VIDEO LOSS SET) VIDEO LOSS OFF DISPLAY FREEZE DATA ON
(VIDEO LOSS SET)
When the live picture signal feed is interrupted, you can set the action taken (frozen picture or colour bars), and if the video loss is recorded as alarm data.
Setting the Video Loss Mode
1 Press the l button to highlight the VIDEO LOSS
setting.
2 Using the + (or –) button select the desired “VIDEO
LOSS setting, then press the l button.
All the other settings are selected using the same procedure.
3
Press the MENU button to go to the next menu
screen, or
Press the EXIT button to exit the menu display.
3
(ACTIVE REC SET) EXT ALARM REC OFF SENSOR REC OFF REC MODE MODE2
(VIDEO LOSS SET) VIDEO LOSS OFF DISPLAY FREEZE DATA ON
ACTIVE REC SET menu
EXT ALARM REC (Default setting: OFF)
ON: When an external alarm trigger is received, active recording is
initiated, the concerned camera pictures being recorded in priority.
OFF: When an external alarm trigger is received, active recording will
not be initiated.
SENSOR REC (Default setting: OFF)
ON:
When a video sensor trigger is received, active recording is initiated, the concerned camera pictures being recorded in priority.
OFF: When a video sensor trigger is received, active recording will not
be initiated.
REC MODE (Default setting: MODE2)
This setting selects the active recording operations.
MODE1:
MODE2: The live pictures from the camera corresponding to the alarm
NOTE:
The live pictures from the camera corresponding to the alarm trigger only are recorded.
trigger is recorded together with the signal from the other cameras.
Please refer to ACTIVE REC Settings Examples on page 34.
Programmed recording function will select the camera to record or the camera priority recording normal mode, but the active recording mode will modify the recording mode for that camera when an external alarm or a video sensor trigger is received.
VIDEO LOSS SET menu
VIDEO LOSS (Default setting: OFF)
You can set the action to take when there is an interruption in the video signal feed.
The video loss will not be active independently of the setting
OFF:
entered for each camera.
INDIV.: The ON/OFF setting will be as set for each of the cameras.
NOTE:
If the INDIV. setting is used, in the (CAMERA SET) menu, enter the desired setting for each camera (see page 36).
DISPLAY (Default setting: FREEZE)
FREEZE:
TEST: When there is a video loss, colour bars are displayed on-screen.
NOTE:
When there is a video loss, the image just previous to the interruption is frozen on-screen.
Depending on the timing of the video loss, a complete picture may not be displayed. Even if a frozen image is selected for the monitor display,
colour bars only can be recorded.
DATA (Default setting: ON)
ON:
The video losses data is recorded as alarm data.
OFF: The video losses data is not recorded.
NOTE:
If the ON setting is used, you can review the video losses data (camera number, date, time) in the (ALARM DATA) menu (see page 45).
English 33
Page 35
ACTIVE RECORDING AND VIDEO LOSS SETTING Menu 5
02
09
02
08
010202
02
02
02
02
09
0205050202040406060202070704040808040409090404
06
gg
02
08
ACTIVE REC Settings Examples
Example 1:
Recording on the tape when an alarm trigger is received from camera 2
(Normal)
010102
01 02 03 04 05 06 07 08 09 010102
(REC MODE: MODE1)
01
01 02 03 04 02 020202 020202 02
(REC MODE: MODE2)
01 02 03 01 02 0304 05 06 07 08 09
Normal recording (no alarm trigger)
Example 2:
Recording on the tape when an alarm trigger is received from camera 4 when an
0404050506060707080809
Alarm trigger in Alarm trigger out
02
Alarm trigger in Alarm trigger out
02
02 020202 020202 020202
Alarm duration for camera 2
02 020202 020202 020202 020202 05 06 07 08
Alarm duration for camera 2
01 02 03 04 05 06 07 08
alarm trigger has already been received from camera 2
Camera 2 picture
040405050606070708
020202
Camera 2 picture Camera 4 picture
020202
040404
(Normal)
010102
01 03 04
02
(REC MODE: MODE1)
01 02 03 04
(REC MODE: MODE2)
01 02 03 04
NOTE: The ACTIVE REC examples are given for function illustration purposes only. The actual recordings will vary according to the
various settings.
0404050506060707080809
05 06 07 08 09
Alarm trigger in Alarm trigger in
020202020202040402020404020204040404040404040404050506
02 02 02 04 02 04 02 04 04 04 04 04 05 06
Alarm duration for camera 2
Alarm trigger in Alarm trigger in
02
02 05 02 04 06 02 07 04 08 04 09 04
Alarm duration for camera 2
010102
01 02 03 04 05 06 07 08
Alarm trigger out Alarm trigger out
Alarm trigger received from camera 4 during the alarm duration for trigger from camera 2
Alarm trigger out Alarm trigger out
Alarm trigger received from camera 4 during the alarm duration for
er from camera 2
tri
040405050606070708
Alarm duration for camera 2 is over, remaining alarm duration for trigger from camera 4
Alarm duration for camera 2 is over, remaining alarm duration for trigger from camera 4
01 02
34 English
Page 36
MONITOR SETTINGS Menu 6
You can set the automatic sequential display speed on each monitor and the display sequence order. Also, you can have the live and/or recorded picture from certain cameras masked so that they are not visible on-screen.
(MONITOR SET)
Setting the Monitor Display
1 Press the MENU button 6 times to display the
(MONITOR SET) menu.
2 Press the l button to highlight the setting to modify.
Using the + (or –) button, select the desired setting, then press the l button.
Following this procedure, select the settings or MON1 SEQ. TIMER ... COLOR LEVEL.
3
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
2
(MONITOR SET)
MON1 SEQ.TIMER 1 S MON2 SEQ.TIMER 1 S QUAD SEQ.TIMER 1 S MON1 SEQ.MODE MODE1 MON2 SEQ.MODE MODE1 MON2 í MON1 OFF MON.MASK LIVE ON MON.MASK VCR ON COLOR LEVEL AUTO
MONITOR SET menu
MON2 SEQ.MODE (Default setting: MODE1)
MODE1: The cameras are displayed full screen sequentially in
order (1 to 9).
MODE2: The cameras are displayed sequentially in the order
set in the (POSITION SET) menu, when the 9 cameras are displayed in a 9 divisions screen (see page 43).
MON2MON1 (Default setting: OFF)
ON: The display on monitor 2 will be the same as the one on
monitor 1.
OFF: The display mode on monitor 2 will an automatic
sequential display or full screen display of live pictures.
MON.MASK LIVE (Default setting: ON)
ON: If, for certain cameras, in the (CAMERA SET) menu, the
MON.MASK item is set to ON, the live picture from those cameras will not be visible on-screen.
OFF: The live picture from all cameras will be visible on-screen
regardless of the MON.MASK item setting of each camera, in the (CAMERA SET) menu.
MON.MASK VCR (Default setting: ON)
ON: If, for certain cameras, in the (CAMERA SET) menu, the
MON.MASK item is set to ON, the recorded picture from those cameras will not be visible on-screen.
OFF: The recorded picture from all cameras will be visible
on-screen regardless of the MON.MASK item setting of each camera, in the (CAMERA SET) menu.
MON1 SEQ.TIMER (Default setting: 1 S)
To set the full screen automatic sequential display speed (interval) on monitor 1.
The available intervals are: 1 – 30 seconds, INDIV.
MON2 SEQ.TIMER (Default setting: 1 S)
The available intervals are: 1 – 30 seconds, INDIV.
NOTE:
If the INDIV. setting is used, in the (CAMERA SET) menu, enter the desired setting for each camera (see page 40).
QUAD SEQ.TIMER (Default setting: 1 S)
To set the 4 divisions screen automatic sequential display speed (interval).
The available intervals are: 1 – 30 seconds
MON1 SEQ.MODE (Default setting: MODE1)
MODE1: The cameras are displayed sequentially in order (1 to
9).
MODE2: The cameras are displayed sequentially in the order
set in the (POSITION SET) menu, when the 9 cameras are displayed in a 9 divisions screen (see page 43).
NOTE:
The individual monitor masking setting is entered for each camera in the (CAMERA SET) menu (see page 39).
COLOR LEVEL (Default setting: AUTO)
AUTO: In divided screen display mode, the colours will be
adjusted automatically.
If in divided screen mode the colours depth changes and
the image is not clear, press the + (or –) button to select the desired level.
The available settings are:
1, 2, 3, 4, 5, AUTO, 5, 6, 7, 8, 9 (A higher number will set the
colours to a depth setting.)
English 35
Page 37
CAMERA SETTING Menu 7
(CAMERA SET) NO.01 TITLE
--------
01
DAY NIGHT
(CAMERA SET) NO.02 TITLE
--------
01
DAY NIGHT
(CAMERA SET) NO.03 TITLE
--------
01
DAY NIGHT
(CAMERA SET) NO.04 TITLE
--------
04
For each camera connected to the unit, you can enter a camera title, such as the camera location, etc., that will be displayed together with the picture from that camera. Also, each camera operating mode and timer recording mode can be set.
(CAMERA SET)
1 Press the MENU button 7 times to display the (CAMERA
SET) menu.
2 The following settings are available.
When finished, press the EXIT button to exit the
menu display.
Camera number
(CAMERA SET) NO.01 TITLE
A
DAY NIGHT PROGRAM REC OFF OFF
B
MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
C
SENSOR SET : PRESS NEXT
D
A A camera title (up to 10 characters) to be displayed with
the live picture of the camera can be entered. The camera title displayed location can be set in the
(DISPLAY SET) menu.
B A day period and a night period can be set and the
following actions can be set accordingly.
B1: PROGRAM REC
Set to ON (or OFF) for programmed recording (or no programmed recording) for each camera.
B2: AL. DURATION
Set the alarm duration for each camera.
B3: MON. MASK
Set to ON (or OFF) for each camera, so that the image from that camera is greyed out (or is not greyed out) and is not visible on the monitor.
Also, in the (MONITOR SET) menu, you must set the monitor masking to be applied to live and/or recorded monitoring.
B4: SEQUENCE
Set the sequential display interval for each camera.
C VIDEO LOSS
Set to ON (or OFF), then in the (VIDEO LOSS SET) menu set the VIDEO LOSS item to INDIV. and enter each setting. If the video signal is interrupted during live picture mode, the image just previous to the interruption is frozen on-screen or colour bars can be displayed. However, the frozen image and colour bars settings cannot be used together.
D SENSOR SET
Sensor areas can be set for every camera screen in live picture mode. By setting certain areas that operate as video sensors, priority recording of the concerned camera pictures can be done when a movement is detected within the set sensor area.
--------
01
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
LEVEL:DAY†OFF NIGHT†OFF MODE:A
ñ
A Setting the camera title
Each camera is selected by pressing the appropriate SELECT (1 9) button.
Example: To set the title “HALL-1F” for camera 3
1 Press the SELECT (3) button. 2 Using the + (or –) button set the first character H, then
press the c button. By pressing the + (or –) button repeatedly, the characters
are selected as follows:
Letters: A, B, C,....X, Y, Z
Numbers: 0, 1,....8, 9
Symbols: , :, ., /, *, _ (blank space)
3 Following the same procedure, enter the rest of the title
ALL-1F”.
Press the MENU button to go to the next menu screen,
or
Press the EXIT button to exit the menu display.
(CAMERA SET) NO.09
12
(CAMERA SET) NO.03 TITLE H
DAY NIGHT PROGRAM REC OFF OFF
MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS OFF
SENSOR SET : PRESS NEXT
-------
TITLE
03
3
(CAMERA SET) NO.03 TITLE HALL-1F-03
DAY NIGHT PROGRAM REC OFF OFF
MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS OFF
SENSOR SET : PRESS NEXT
--------
09
36 English
Page 38
CAMERA SETTING Menu 7
B1 Setting up programmed recording for each
camera
1 Press the MENU button twice to display the (TIMER
SET) menu, then check that the day and night periods are set as desired. (For more information on the day and night periods settings, see TIMER SET on page
27.)
2 Press the MENU button once to display the (VCR SET)
menu. Press the l button to highlight the “PROGRAM REC
MODE setting.
3 Using the + (or –) button, set “MODE1” or “MODE2”.
(For more information on each mode operation, see PROGRAM REC MODE on page 29.)
4 Press the MENU button four times to display the
(CAMERA SET) menu.
5 Press the SELECT (1 – 9) button to select the desired
camera (ex: camera 5).
6 Press the l button to highlight the PROGRAM REC
setting.
1 Press the + (or –) button to set ON” in the DAY column,
then press the c button.
2 Press the + (or –) button to set ON” in the NIGHT
column.
Programmed recording will be conducted according to the MODE1 or MODE2 setting entered in the (VCR SET) menu.
7
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
1
(CLOCK SET) 15-10-1999 FRI 15:20:00
(TIMER SET) DAYTIME
(SUMMER TIME SET) MODE NO USE WEEK MON TIME ON LST-SUN 03 02:00 OFF LST-SUN 10 02:00
07:30-19:30
MENU
2, 3
(VCR SET) VCR MODE TLS REC SPEED 3 H ALARM REC SPEED 3 H PROGRAM REC MODE OFF
(SERIAL SET) DATA SPEED 19200 ALARM SEND OFF ööADDRESS:000öö
MENU
4
(CAMERA SET) NO.01 TITLE
DAY NIGHT PROGRAM REC OFF OFF
MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
--------
MENU
OFF
MODE1
MODE2
5, 6
01
(CAMERA SET) NO.05 TITLE
DAY NIGHT PROGRAM REC ON ON
MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
5
--------
05
CAMERA SET menu
PROGRAM REC (Default setting: DAY and NIGHT to OFF)
ON: When the time set in the (TIMER SET) menu is reached,
the pictures from this camera will be recorded in priority.
OFF: Programmed recording will not be done.
English 37
Page 39
CAMERA SETTING Menu 7
B2 Setting the alarm duration for each camera
1 Press the MENU button twice to display the (TIMER
SET) menu, then check that the day and night periods are set as desired. (For more information on the day and night periods settings, see TIMER SET on page
27.)
2 Press the MENU button twice to display the (ALARM
SET) menu.
3 Using the + (or –) button, set “INDIV.” for the
DURATION item.
NOTE: In the (CAMERA SET) menu, the item
AL.DURATION will only be displayed if theDURATION item is set to INDIV.”.
4 Press the MENU button three times to display the
(CAMERA SET) menu.
5 Press the SELECT (1 – 9) button to select the desired
camera (ex: camera 5).
6 Press the l button to highlight the “AL.DURATION”
setting.
1 Press the + (or –) button to set the desired duration
(ex: 20 sec.) in the DAY column, then press the c button.
2 Press the + (or –) button to set the desired duration
(ex: 30 sec.) in the NIGHT column.
If there is an alarm triggered, the alarm duration will be as set for each camera.
7
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
1
(CLOCK SET) 15-10-1999 FRI 15:20:00
(TIMER SET) DAYTIME
(SUMMER TIME SET) MODE NO USE WEEK MON TIME ON LST-SUN 03 02:00 OFF LST-SUN 10 02:00
07:30-19:30
MENU
2, 3
(ALARM SET) DURATION INDIV. RETRIGGER OFF BUZZER ON DATA ON MON.1 OUT FULL DOUBLE ALARM LAST MON.2 OUT OFF (SENSOR SET) SENSOR ALARM OFF DURATION 10 S
MENU
4
(CAMERA SET) NO.01 TITLE
DAY NIGHT PROGRAM REC OFF OFF AL.DURATION 10 S 10 S MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
--------
MENU
5, 6
01
(CAMERA SET) NO.05 TITLE
DAY NIGHT PROGRAM REC ON ON AL.DURATION 20 S 30 S MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
5
--------
05
CAMERA SET menu
AL. DURATION (Default setting: DAY and NIGHT to 10 S)
If in the (ALARM SET) menu, the item DURATION is set toINDIV., enter the desired alarm duration for each camera.
The available durations are:
1, 2, 3, 4, 5, 10, 20 (in 10 seconds increments)... 180, CC, NC, OFF
CC: The alarm will go on as long as the alarm signal is
received (minimum 1 second).
NC: The alarm will continue until reset. OFF: No alarm duration setting.
38 English
Page 40
CAMERA SETTING Menu 7
03
04
01
02
04
07
09
B3 Setting the monitor masking for each camera
1 Press the MENU button twice to display the (TIMER
SET) menu, then check that the day and night periods are set as desired. (For more information on the day and night periods settings, see TIMER SET on page
27.)
2 Press the MENU button five times to display the
(CAMERA SET) menu.
3 Press the SELECT (1 – 9) button to select the desired
camera (ex: camera 5).
4 Press the l button to highlight the “MON.MASK”
setting.
1 Press the + (or –) button to set ON” in the DAY column,
then press the c button.
2 Press the + (or –) button to set ON” in the NIGHT
column.
5 Press the EXIT button to exit the menu mode and return
to live picture mode, then press the MENU button six times to display the (MONITOR SET) menu.
6 Press the l button to highlight the MON.MASK LIVE
setting. 1 Press the + (or ) button to set ON for the MON.MASK
LIVE item, then press the l button.
2 Press the + (or ) button to set ON for the MON.MASK
VCR item.
7
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
1
(CLOCK SET) 15-10-1999 FRI 15:20:00
(TIMER SET) DAYTIME
(SUMMER TIME SET) MODE NO USE WEEK MON TIME ON LST-SUN 03 02:00 OFF LST-SUN 10 02:00
07:30-19:30
MENU
2
(CAMERA SET) NO.01 TITLE
DAY NIGHT PROGRAM REC OFF OFF AL.DURATION 10 S 10 S MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS OFF
SENSOR SET : PRESS NEXT
--------
MENU
5, 6
(MONITOR SET)
MON1 SEQ.TIMER 1 S MON2 SEQ.TIMER 1 S QUAD SEQ.TIMER 1 S MON1 SEQ.MODE MODE1 MON2 SEQ.MODE MODE1 MON2 í MON1 OFF MON.MASK LIVE ON MON.MASK VCR ON COLOR LEVEL AUTO
MENU
EXIT
3, 4
(CAMERA SET) NO.05
01
TITLE
DAY NIGHT PROGRAM REC ON ON AL.DURATION 10 S 10 S MON.MASK ON ON SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
5
--------
05
CAMERA SET menu
MON. MASK (Default setting: DAY and NIGHT to OFF)
If in the (MONITOR SET) menu, monitor masking is set to ON for live and/or recorded monitoring, set this item for each camera.
ON: The pictures from this camera will be masked (not
displayed).
OFF: The pictures from this camera will be visible.
Example
010101
04
04 060606
07 080808
07
01
01 02
03
03 04
020202 030303
050505
02
04
09
09
English 39
Page 41
CAMERA SETTING Menu 7
B4 Setting the sequential display interval for
each camera
1 Press the MENU button twice to display the (TIMER
SET) menu, then check that the day and night periods are set as desired. (For more information on the day and night periods settings, see TIMER SET on page
27.)
2 Press the MENU button four times to display the
(MONITOR SET) menu.
3 1 Using the + (or ) button, set INDIV. for the MON1
SEQ.TIMER item, then press the l button.
2 Using the + (or ) button, set INDIV. for the MON2
SEQ.TIMER item.
4 Press the MENU button once to display the (CAMERA
SET) menu.
5 Press the SELECT (1 – 9) button to select the desired
camera (ex: camera 5).
6 Press the l button to highlight the “SEQUENCE”
setting.
1 Press the + (or –) button to set the desired sequential
display interval (ex: 10 sec.) in the DAY column, then press the c button.
2 Press the + (or –) button to set the desired sequential
display interval (ex: 20 sec.) in the NIGHT column.
7
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
CAMERA SET menu
1
(CLOCK SET) 15-10-1999 FRI 15:20:00
(TIMER SET) DAYTIME
(SUMMER TIME SET) MODE NO USE WEEK MON TIME ON LST-SUN 03 02:00 OFF LST-SUN 10 02:00
07:30-19:30
MENU
2, 3
(MONITOR SET)
MON1 SEQ.TIMER INDIV. MON2 SEQ.TIMER INDIV. QUAD SEQ.TIMER 1 S MON1 SEQ.MODE MODE1 MON2 SEQ.MODE MODE1 MON2 í MON1 OFF MON.MASK LIVE ON MON.MASK VCR ON
COLOR LEVEL AUTO
MENU
4
(CAMERA SET) NO.01 TITLE
DAY NIGHT PROGRAM REC OFF OFF AL.DURATION 10 S 10 S MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
--------
MENU
5, 6
01
(CAMERA SET) NO.05 TITLE
DAY NIGHT PROGRAM REC ON ON AL.DURATION 10 S 10 S MON.MASK OFF OFF SEQUENCE 10 S 20 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
5
--------
05
SEQUENCE (Default setting: DAY and NIGHT to 1 S)
If in the (MONITOR SET) menu, the items MON1 SEQ.TIMER and/or MON2 SEQ.TIMER are set to INDIV., enter the desired sequential display interval for each camera.
The available durations are: 1 to 30 sec., SKIP SKIP: In automatic sequential display, this camera will not be
displayed.
40 English
Page 42
CAMERA SETTING Menu 7
C Setting the video loss operation mode
1 Press the MENU button four times to display the (VIDEO
LOSS SET) menu, then press the l button to highlight the VIDEO LOSS setting.
2 Using the + (or –) button, set “INDIV.” for the “VIDEO
LOSS item.
3 Press the MENU button twice to display the (CAMERA
SET) menu.
4 Press the SELECT (1 – 9) button to select the desired
camera (ex: camera 5).
5 Press the l button to highlight the VIDEO LOSS
setting.
Using the + (or –) button, set ON for the VIDEO LOSS item.
6
VIDEO LOSS (Default setting: ON)
Set the action to take when there is an interruption in the live video signal feed.
ON: A video loss alarm trigger is sent. OFF: No video loss alarm trigger sent.
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
CAMERA SET menu
1, 2
(ACTIVE REC SET) EXT ALARM REC OFF SENSOR REC OFF REC MODE MODE2
(VIDEO LOSS SET) VIDEO LOSS INDIV. DISPLAY FREEZE DATA ON
MENU
3
(CAMERA SET) NO.01 TITLE
DAY NIGHT PROGRAM REC OFF OFF AL.DURATION 10 S 10 S MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
--------
MENU
4, 5
01
(CAMERA SET) NO.05 TITLE
DAY NIGHT PROGRAM REC OFF OFF AL.DURATION 10 S 10 S MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
5
--------
05
English 41
Page 43
CAMERA SETTING Menu 7
D Setting the video sensor area position,
sensitivity level and response mode
1 Press the SELECT (1 – 9) button to select the desired
camera (ex: camera 6).
2 Press the NEXT button.
The live picture from the selected camera and the video sensor setting screen for that camera are displayed.
1, 2
(CAMERA SET) NO.06 TITLE
DAY NIGHT
NEXT
6
PROGRAM REC OFF OFF
MON.MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON
SENSOR SET : PRESS NEXT
--------
06
3 Set the video sensor area position.
Using the l, j, d and c buttons, move the cursor to the
1
desired position according to the picture in the background.
2 Using the + (or –) button, set A or B for the selected point.
Every time the + button is pressed, the setting will change as follows:
A B - A...
Repeat steps 1 and 2 to set all the desired video sensor points of the desired area(s).
Set the desired point(s) to setting A or B.
indicates a sensor point without any setting (there are
10 lines of 16 points each), that is not used as video sensor.
To erase a line of video sensor points (A or B), move the
cursor to the line to erase, then press the MENU RESET button.
3
-1 Sensor point not used
3
-2 Sensor point A
3
-2 Sensor point B
----------------
----------------
----------------
----------------
------AAAA------
----------------
----------------
----------------
------------BBBB
----------------
LEVEL:DAY†8 NIGHT†10 MODE:A
(LEVEL DAY)
4. Sensitivity level for the day period (ex.: 8)
(LEVEL NIGHT)
4. Sensitivity level for the night period (ex.: 10)
(MODE)
5. Sensor response mode
ñ
Modifying the sensor position
In the default sensor screen, the first line of sensor positions will be empty. If you need to set sensor points on this line, please first follow the steps below.
1 Using the j (or l) button, highlight the LEVEL : DAY
setting.
2 Using the c (or d) button, move the cursor to the arrow
(ñ), then press the + (or –) button.
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
LEVEL:DAY†8 NIGHT†10 MODE:A
ñ
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
LEVEL:DAY†8 NIGHT†10 MODE:A
4 Set the sensor sensitivity level.
Using the j (or l) button highlight the “LEVEL : DAY setting.
1 2 Press the c button, then using the + (or –) button set the
desired sensitivity level for the DAY period.
Follow the same procedure to set the desired sensitivity level for the NIGHT period.
The available sensitivity levels are: OFF
1, 2, 3...10 (10 being the least sensitive, default setting), OFF.
NOTE:
The sensor sensitivity level can only be checked for the time of the setting. (I.e., the night level setting cannot be checked during the day.)
5 Set the sensor response mode.
Press the c button to highlight the “MODE setting.
1 2 Using the + (or –) button set the desired mode.
MODE: A (default setting)
The video sensor will send a trigger when it detects movement at the video sensor area points A.
MODE: A AND B
Set points A and points B at a predetermined distance, so that only large subjects, that are detected by both video sensor points simultaneously send an alarm trigger. Smaller objects that are detected only by one set of video sensor points at the time will not send an alarm trigger.
MODE: A AND NB (Fig. 1)
Set the video sensor points A at the centre of the main area, and video sensor points B at the periphery, where no movement will be detected. A trigger will be sent when change is only detected at the video sensor points A, not at the video sensor points B. For example, if the whole screen (A and B) brightness changes due to a change in lighting or sunrays, a trigger is not sent. But, if a change is detected only at the centre of the screen (A), a trigger is sent.
(Fig. 1)
------- BBB
----- BB B
AAAAA AAAAA AAAAA B BB BBB
LEVEL:DAY†8 NIGHT†10 MODE:A AND NB
ó
ó
6
Press the NEXT button to return to the (CAMERA
SET) menu display, or Press the EXIT button to exit the menu display.
42 English
Page 44
SETTING EACH CAMERA DISPLAY POSITION IN
04
07
05
07
09
SPLIT SCREEN DISPLAY MODE Menu 8
You can set where each camera will be displayed when viewing a split screen display. Setting for 9 divisions split screen is available.
(POSITION SET)
Changing a camera position
1 Press the MENU button 8 times to display the
(POSITION SET) menu.
The 9 divisions setting screen is displayed.
2 Example: To interchange the display positions of
camera 4 and camera 9.
1 Using the l, j, d and c buttons, move the cursor to
the first camera number (04).
2 Press the + (or –) button to change the number to the
desired camera number (09). When a camera is moved to a certain position, it will
switch display positions with the camera that was previously displayed at that position.
3
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
1
(POSITION SET)
MULTI 9
01 02 03 04 05 06 07 08 09
MENU
2-
1
(POSITION SET)
MULTI 9
01 02 03 04 05 06 07 08 09
Example of switched camera display
010101 020202 030303
04
04 050505 060606
2-
2
(POSITION SET)
MULTI 9
01 02 03 09 05 06 07 08 04
07 080808 090909
07
010101 020202 030303
09
09
07 080808
07
05
05 060606
040404
English 43
Page 45
CLOCK AND TITLE DISPLAY SETTINGS Menu 9
04
07
04
07
The clock and the camera title settings entered in the menus (CLOCK SET) and (CAMERA SET, TITLE) can be displayed on-screen, and their display position can be set.
(DISPLAY SET)
Setting the clock and title display
1 Press the MENU button 9 times to display the (DISPLAY
SET) menu.
2 Using the + (or –) button select the desired setting, then
press the l button. Following this procedure, select the settings for LIVE
CLOCK, TITLE and VCR PB CLOCK, TITLE.
3 Press the l button to highlight the TITLE POSITION
setting.
4 Using the + (or –) button select the desired title display
position. UP: The title will display at the top of the screen. DOWN: The title will display at the bottom of the screen.
(Default setting)
5
Press the NEXT button to switch to the “CLOCK
POSITION SET screen. To return to the (DISPLAY SET) menu, press the NEXT button again.
Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
(DISPLAY SET)
1, 2
LIVE CLOCK ON TITLE ON VCR PB CLOCK OFF TITLE ON
TITLE POSITION DOWN
CLOCK POSITION SET † PRESS NEXT
MENU
Example of title
position display
(DISPLAY SET)
3, 4
LIVE CLOCK ON TITLE ON VCR PB CLOCK ON TITLE ON
TITLE POSITION DOWN
CLOCK POSITION SET † PRESS NEXT
HALL-1F
HALL-1F
DISPLAY SET menu
LIVE CLOCK (Default setting: OFF)
OFF: The date and time are not displayed during live picture
mode.
ON: The date and time are displayed during live picture mode.
LIVE TITLE (Default setting: ON)
OFF: The camera title is not displayed during live picture mode. ON: The camera title is displayed during live picture mode.
VCR PB CLOCK (Default setting: OFF)
OFF: The recorded date and time are not displayed during VCR
playback picture mode.
ON: The recorded date and time are displayed during VCR
playback picture mode.
VCR PB TITLE (Default setting: ON)
OFF: The recorded camera title is not displayed during VCR
playback picture mode.
ON: The recorded camera title is displayed during VCR
playback picture mode.
Setting the clock display position
1 Press the NEXT button.
The clock display position setting screen is displayed.
2 Using the j (or l) button, set the clock display
position.
3
Press the NEXT button to return to the (DISPLAY
SET) menu Press the MENU button to go to the next menu
screen, or Press the EXIT button to exit the menu display.
Example of clock display
(TITLE POSITION: DOWN)
15-10-1999 15:40:00
01
15-10-1999 00:15:40
01 02
(TITLE POSITION: UP)
15-10-1999 15:40:00
01
01 02
15-10-1999 00:15:40
03 04
03 04
15-10-1999 00:15:40
010101 020202 030303
04 050505 060606
04
07 080808 090909
07
44 English
010101 020202 030303
15-10-1999 00:15:40
04 050505 060606
04
07 080808 090909
07
Page 46
ALARM DATA DISPLAY Menu 10
The alarm recordings are done according to the settings entered in the (ALARM SET), (SENSOR SET) and (VIDEO LOSS SET) menus. Information about the alarms (alarm data) is also recorded and can be displayed on-screen.
(ALARM DATA)
Displaying the Alarm Data
1 Press the MENU button 10 times to display the (ALARM
DATA) menu.
2 Press the NEXT (or l) button to display the next screen
of alarm data entries.
The alarm data is displayed from the most recent ones, 8 entries per screen, up to a maximum of 100 entries (13 screens).
Press the j button to display the previous screen of alarm data entries.
3
Press the EXIT button to exit the menu display.
1
(ALARM DATA) 1/13 CAM DATE TIME ITEM 1 4 22-08 08:48 E 2 2 21-08 08:51 S 3 4 04-05 16:22 E 4 3 04-05 07:45 V 5 1 30-04 14:37 E 6 1 21-04 18:26 V 7 2 12-04 05:31 E 8 4 12-04 12:51 E
MENU
2
(ALARM DATA) 2/13 CAM DATE TIME ITEM 9 4 29-03 17:40 E 10 2 26-03 08:49 V 11 4 13-03 09:25 E 12 3 05-03 08:15 S 13 1 11-02 15:18 E 14 1 29-02 12:30 V 15 2 21-02 08:21 E 16 4 15-01 11:34 E
NEXT
The codes in the ITEM column indicate the type of alarm data.
E: External alarm trigger (see page 46) S: Video sensor trigger (see page 42, 47) V: Video loss (see page 46)
NOTE:
When the number of recorded alarm data entries reaches
100, the oldest ones are erased as new ones are recorded. The illustrated alarm data entries screens are a sample of
alarm inputs.
English 45
Page 47
ALARMS OPERATIONS
VIDEO LOSSVIDEO LOSSVIDEO LOSS
LIVE PICTURES MODE ALARM
There are three types of live pictures alarms; the alarms set by an external alarm trigger, the alarms set by a loss of the video signal and the alarms set by the video sensors.
EXTERNAL ALARMS
Connect external inputs such as a door bell, an interphone, etc., to the ALARM IN terminals (1 – 9). These external switches will send triggers to the alarm inputs and the alarm display will be shown in live pictures mode.
Example: If an alarm trigger is received for camera 4
(in multi-display screen)
1 The buzzer is heard and the camera 4 indicator light.
The alarm output changes from HI (5V) to LOW (0V).
2 The image from camera 4 and the camera number (04)
will be displayed on monitor 1, EA (External Alarm) will flash at the left of the camera number.
The action taken here will depend on the settings entered in the (ALARM SET) menu (see page 31).
EA 04
External alarm Camera number
NOTE:
When the alarm operation is over, the display will return to
the mode preceding the alarm trigger. An alarm trigger can also be received at a terminal for which
a camera is not connected to. In such a case, a grey screen will be displayed and EA (External Alarm) and the corresponding number will be displayed.
Resetting the Alarm
For an alarm in full screen display mode, press the
corresponding SELECT button. For an alarm in multi-display screen mode, press the
corresponding SELECT button to switch to full screen display mode, then press the same SELECT button one more time.
NOTE:
The alarm display mode on monitor 1 is selected according to
the settings entered in the (ALARM SET) menu. During normal monitoring operations the camera select
indicator lights according to the displayed camera. If there is an alarm trigger for another camera, the indicator will flash.
VIDEO LOSS ALARM
If there is an interruption of the video signal, the buzzer is heard, and the image just previous to the interruption is frozen on-screen or test chart are displayed and VIDEO LOSS will flash on-screen.
The action taken will depend on the settings entered in the (VIDEO LOSS SET) menu (see page 33).
VIDEO LOSS
VIDEO LOSSVIDEO LOSS
(Test chart)
NOTE:
If a video signal is not present from the beginning, then NO
VIDEO” will be displayed on a gray screen. This will not trigger a video loss alarm.
During video loss alarm a frozen image or test chart are
displayed on-screen. However, on the video tape, test chart are recorded until the alarm is reset or the video signal is restored.
Even if the video loss is set to a frozen image, test chart will
be displayed when the screen display is switched, or during sequential display.
Resetting the Alarm
For an alarm in full screen display mode, press the
corresponding SELECT button, NO VIDEO” will be displayed on a grey screen.
For an alarm in multi-display screen mode, press the
corresponding SELECT button to switch to full screen display mode. Then, press the same SELECT button one more time and NO VIDEO will be displayed, on a grey screen, on the monitor screen.
NOTE:
The alarm display mode on monitor 1 is selected according to
the settings entered in the (ALARM SET) menu. During normal monitoring operations the camera select
indicator lights according to the displayed camera. If there is an alarm trigger for another camera, the indicator will flash.
If the alarm is not reset, VIDEO LOSS will be displayed until
normal live picture signals are restored. If the display mode is changed it will switch from a frozen picture to test chart.
46 English
Page 48
ALARMS OPERATIONS
VIDEO SENSOR ALARM
When in the (SENSOR SET) menu, the SENSOR ALARM item is set to ON or AND, a moving subject detected by the video sensor in the selected area of the image can trigger an alarm.
Example: If movement is detected at camera 4 (in
multi-display screen)
1 The buzzer is heard and the SELECT 4 indicator flashes.
That particular alarm output changes from OPEN to LOW (0V).
2 The image from camera 4 and the camera number (04)
will be displayed on monitor 1, and SA (Sensor Alarm) will flash at the left of the camera number.
The action (such as the alarm duration, alarm recording mode, etc.) taken here will depend on the settings entered in the (SENSOR SET) and the (ACTIVE REC SET) menus (see pages 32, 33).
SA 04
Sensor alarm Camera number
RECORDED PICTURES MODE ALARM
There are two types of recorded pictures alarms; the alarms recorded on tape and the alarms set by an external alarm trigger.
Alarms recorded on tape
When a tape with recorded alarm triggers is played back, this unit will trigger an alarm, and the alarm display will appear on the concerned camera picture, but the alarm operation will not be activated as for live pictures mode alarms.
External Alarms
If during VCR playback, an alarm trigger is received at the
ALARM IN terminals on back panel, the concerned camera SELECT indicator flashes, the buzzer is heard and the alarm signal is output at the corresponding ALARM OUT terminal. However, the display on monitor 1 will not switch as for the live pictures mode external alarms operations.
If in the (ALARM SET) menu, the item MON.2 OUT is set to
ON, the alarm screen live pictures will be displayed on
monitor 2. To monitor the alarm on monitor 1, switch to live pictures mode.
Resetting the Alarm
For an alarm in full screen display mode, press the
corresponding SELECT button during the alarm operation. For an alarm in multi-display screen mode, press the
corresponding SELECT button to switch to full screen display mode, then press the same SELECT button one more time.
English 47
Page 49
INTERFACE SPECIFICATIONS
RS232C (9-pin connector layout)
54321
9876
Pin No. Signal Function Signal direction
1 –– – 2 RXD Data reception Computer Multiplexer 3 TXD Data transmission Multiplexer Computer 4 –– – 5 GND Ground 6 –– – 7 RTS Request to send Multiplexer Computer 8 –– – 9 ––
DATA FORMAT
Mode Asynchronous Character length 8 bits Data transmission speed 2400, 4800, 9600, 19200 bps
(set in the (SERIAL SET) menu)
Parity check None Stop bit One bit
TRANSMISSION PROTOCOL
The transmission is based on 1 byte units. After the computer has transmitted 1 byte, it will wait for an answer from this unit, then send the following byte of data.
The command ON (F6) is sent to start, and the command OFF (F7) is sent to finish. This unit will receive the commands, and will reply to each command by ACK (0A). (Refer to COMMAND
TABLE 4 on page 52.)
RS-485 (RJ-11 connector layout)
123456
Pin No. A terminal signal B terminal signal
1 Not used Not used 2 Not used Not used 3 A signal B signal 4 B signal A signal 5 Not used Not used 6 Not used Not used
A: Non-inverting driver output/receiver input B: Inverting driver output/receiver input
Transmission line: 2 conductors Transmission system: Half duplex
DATA FORMAT
Mode Asynchronous Character length 8 bits Data transmission speed 2400, 4800, 9600, 19200 bps
(set in the (SERIAL SET) menu)
Parity check None Stop bit One bit
TRANSMISSION PROTOCOL
A proprietary protocol (SSP: Security Serial Protocol) is used. Operates using a Sanyo controller or a controller using containing this protocol.
48 English
Page 50
INTERFACE SPECIFICATIONS
SETTING THE DIP SWITCHES
The DIP switches need to be set when a computer, special controller, etc. connected to the RS-232C or RS-485 connectors is used to control the multiplexer. Make sure to turn the multiplexer power off before setting the DIP switches.
(ADDRESS SET)
ON
ON
12345678910
OFF
SW No.
1-7: To setup the multiplexer address (only when using the
RS-485 connector). Switch 1 is the least significant bit (LSB) and switch 7 the
most significant bit (MSB) (Down: 0, Up: 1)
8: Open (not used) 9: To select the connector used. [232] side (down) for
RS-232C, [485] side (up) for RS-485.
10: To setup the termination (only when using the RS-485
connector).
OFF side (down): Not terminated ON side (up): Terminated
RS-232C exclusive use
1. Set the DIP switch 9 down ([232] position).
RS-485 exclusive use
1. Set the address using DIP switches 1 to 7. Example:
If the address is 1, set switch 1 to the ON side (up)
If the address is 10, set switches 2 and 4 to the ON side
(up) If the address is 127, set all the switches to the ON side
(up)
2. Set the DIP switch 9 up ([485] position).
3. Set the terminator using DIP switch 10
RS485
ON
OFF
TERMINATER ON/OFF
RS232C
COMMANDS
COMMANDS AVAILABLE FROM THE COMPUTER
1-9 (90-98)
To select the picture from a camera to be displayed full screen on monitor 1.
MULTI (82)
To display a 9 divisions split screen on monitor 1.
QUAD (83)
To display a 4 divisions split screen on monitor 1.
PLUS (84)
To display a 6 divisions split screen on monitor 1.
SEQUENCE (87)
To switch the display mode from full screen to sequential display on monitor 1.
ZOOM (85)
To zoom in the picture on monitor 1.
STILL (86)
To freeze the picture on monitor 1.
LIVE (80)
To select the live input mode.
VCR (81)
To select the VCR playback input mode.
MON 2 (88)
To set the output at monitor 2, it can be used in combination with the monitor 1 display.
MENU (74)
To display the menu on monitor 1.
+ (65), – (66)
To select settings (ON/OFF, numbers, letters, symbols) in the menus.
j (54), l (64), c (63), d (53)
To change selection in the menus. (To move the cursor up/down, right/left.)
NEXT (75)
To select the sub-menu in (SENSOR SET) and (DISPLAY SET) menus.
EXIT (76)
To go to the next menu, or to exit the menu mode.
MENU RESET (E1)
To reset all the values of the displayed menu to the default values.
CLOCK ADJUST (E0)
To reset the clock minutes and seconds setting to 00:00.
SECURITY LOCK ON (69)
To set the security lock.
SECURITY LOCK OFF (6A)
To cancel the security lock.
English 49
Page 51
INTERFACE SPECIFICATIONS
INFORMATION GATHERING COMMANDS
STATUS SENSE(D7)
When this command is sent from the computer, this unit will send a 5-byte response (see Table 1).
RXD TXD
STATUS SENSE(D7) byte assignment (Table 1)
Fourth and fifth bytes are reserved.
First byte
Bit Bit state information
7 LIVE/VCR indication 0: LIVE picture mode
6 Monitor 1 display
mode indication
5 001: 4 divisions split screen 4 010: Multi-display screen 4 011: Plus-display screen 4 100: Menu display 3 Monitor 1 displayed
channel depending
2 0000: Channel 1
on the display mode
1 0001: Channel 2
indication
0 0010: Channel 3
D7
d1 d2 d3 d4 d5
1: VCR playback mode 000: Full screen
(Full screen mode)
0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9
(4 divisions split screen)
0000: 4 divisions split screen
(channels 1, 2, 3, 4)
0001: 4 divisions split screen
(channels 5, 6, 7, 8)
0010: 4 divisions split screen
(channels 9)
(Multi-display)
0000: Full screen 1000: 9 divisions split screen
(Plus-display)
0000: Channel 1 0001: Channel 2 0010: Channel 3 0011: Channel 4 0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9
(Menu display)
0001: (LANGUAGE/LANG./SPRACHE)
menu 0010: (CLOCK SET) menu 1000: (VCR SET) menu 0100: (ALARM SET) menu 0101: (ACTIVE REC SET) menu 0110: (MONITOR SET) menu 0011: (CAMERA SET) menu 1110: (POSITION SET) menu 0111: (DISPLAY SET) menu 1001: (ALARM DATA) menu
Second byte
Bit Bit state information
7 EXT/ALARM
indication
6 VIDEO LOSS
indication 5 SENSOR indication SENSOR is ON 4 Reserved 0 3 Monitor 1 display
state mode indication
2 0001: Sequential display mode 1 0010: Zoomed in mode 0 0011: Still image mode
EXT and ALARM are ON
VIDEO LOSS is ON
0000: Normal display mode
0100: Frozen zoomed in image 0101: Zoomed in still image 0110: Zoom range setting mode 0111: Zoomed in still image range setting
mode
Third byte
Bit Bit state information
7 Reserved – 6 Reserved – 5 Monitor 2 operation MON2 setup 4 Monitor 2 operation 0: Full screen
1: Sequential display
3 Monitor 2 displayed
channel
2 0001: Channel 2 1 0010: Channel 3 0 0011: Channel 4
0000: Channel 1
0100: Channel 5 0101: Channel 6 0110: Channel 7 0111: Channel 8 1000: Channel 9
50 English
Page 52
INTERFACE SPECIFICATIONS
ALARM STATUS SENSE(D5)
The external and video loss alarm states are indicated by a 6-byte response (see Table 2).
RXD TXD
D5
d1 d2 d3 d4 d5 d6
ALARM STATUS SENSE(D5) byte assignment (Table 2)
First byte Second byte
Bit Bit
7 ALARM ON 8 7 6 ALARM ON 7 6 5 ALARM ON 6 5 4 ALARM ON 5 4 3 ALARM ON 4 3 2 ALARM ON 3 2 1 ALARM ON 2 1 0 ALARM ON 1 0 ALARM ON 9
Third byte Fourth byte
Bit Bit
7 SENSOR 8 7 6 SENSOR 7 6 5 SENSOR 6 5 4 SENSOR 5 4 3 SENSOR 4 3 2 SENSOR 3 2 1 SENSOR 2 1 0 SENSOR 1 0 SENSOR 9
COMMANDS AVAILABLE FROM THE MULTIPLEXER
ACK(0A)
Response when this unit receives a command.
NAK(0B)
Response if this unit did not receive the command.
ALARM(BF)
When there is an alarm, this command is sent as header. Then, the alarm information is sent in a 1-byte transmission (see Table
3).
ALARM information (Table 3)
Bit Bit state information
7 Alarm information
indication
6 01: External
5 Reserved 0 4 Reserved 0 3 Camera number
indication
2 0001: CAMERA NO. 2 1 0010: CAMERA NO. 3 0 0011: CAMERA NO. 4
00: No alarm
10: Video loss 11: Sensor alarm
0000: CAMERA NO. 1
0100: CAMERA NO. 5 0101: CAMERA NO. 6 0110: CAMERA NO. 7 0111: CAMERA NO. 8 1000: CAMERA NO. 9
Fifth byte Sixth byte
Bit Bit
7 VIDEO LOSS 8 7 6 VIDEO LOSS 7 6 5 VIDEO LOSS 6 5 4 VIDEO LOSS 5 4 3 VIDEO LOSS 4 3 2 VIDEO LOSS 3 2 1 VIDEO LOSS 2 1 0 VIDEO LOSS 1 0 VIDEO LOSS 9
English 51
Page 53
INTERFACE SPECIFICATIONS
COMMAND TABLE (TABLE 4)
The commands available are indicated in the table. If a function is not available on the unit, the command will not operate even if sent.
0123 4 5 6 7 8 9 00 LIVE FULL 1 11 VCR PB FULL 2 2 2 VERSION MULTI FULL 3 33»« QUAD FULL 4 441O MENU PLUS FULL 5 55 + NEXT ZOOM FULL 6 66 EXIT STILL FULL 7 77 SEQ. FULL 8 88 MON 2 FULL 9 9 9 SECURITY LOCK ON A ACK SECURITY LOCK OFF B NAK
C GROUP SET* D GROUP CHECK*
E GROUP CLEAR* F
ABC D EF 0 CLK. ADJ. 1 MENU RESET 2 3 4 5 ALARM STATUS SENSE 6 ON** 7 STATUS SENSE OFF** 8 9 A B
C D RS485
E RS485 RCV
F ALARM*
TRANSMISSION
START*
CHECK*
* Only RS485
** Only RS232C
52 English
Page 54
SPECIFICATIONS
Signal format : Based on PAL colour signal standard Camera signal input synchronization : Asynchronous Camera input terminals (IN) : VS/VBS, 1.0 Vp-p/75 , BNC connector x 9 Camera output terminals (OUT) : Throughput of each input, 1.0 Vp-p/75 , BNC connector x 9 VCR input terminal (VCR IN)
Composite input : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1
S-VHS input terminal (S-VIDEO VCR IN): Separate YC signals, DIN connector (S terminal) x 1
VCR output terminal (VCR OUT)
Composite output : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1
S-VHS output terminal (S-VIDEO VCR
OUT)
Monitor 1 output terminal (MONITOR OUT 1) : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1
Monitor 2 output terminal (MONITOR OUT 2) : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1
Control terminal (CONTROL)
Alarm input : No voltage, make-contact switch input x 9 (Low input)
Sensor alarm output : Alarm output x 9 (low output, normally open (NO))
Remote input : 2-wire type with resistance-based identification system
Alarm output : DC 5 V, 5.7 k (Low output)
Switching input : Low input, for input signal from SW OUT of timelapse VCR/real time recorder (as
RS485 control terminal : RJ-11 type: 2 terminals (A/B), Push-lock type: 3 terminals (A, B, C: Ground)
RS-232C terminal : 9-pin D-SUB
Full screen sequence timing : Available in full screen mode, with interval selectable from 1 – 30 sec. Monitor on-screen display : Title (up to 10 characters), date, time selectable Menu settings : 10 menus: Language, Clock, VCR, Alarm, Active REC, Monitor, Camera, Position,
Alarm sensor : Internal, 9 channel (each camera input, selectable) Back-up function : Back-up for up to 30 days of the clock settings after connected for 30 hours
Operations
Still : Available for camera live or VCR playback in full screen and zoomed in picture
2x zoom : Available for camera live or VCR playback in full screen and frozen picture
Power : AC 100/120/230/240 V; 310/300/170/170 mA, 50/60 Hz Consumption : 20 W Operating environment : Temperature: 5 to 40˚C, Humidity: 10 to 80% Dimensions : 420 (W) x 86 (H) x 325 (D) mm Weight : Approx. 4.1 kg
Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.300 Vp-p/75 Ω, unbalanced
: Separate YC signals, DIN connector (S terminal) x 1
Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.300 Vp-p/75 Ω, unbalanced
Separate YC signals, DIN connector (S terminal) x 1 Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.300 Vp-p/75 Ω, unbalanced
Camera live picture or VCR playback picture signal output: full screen, sequential display, Multi-display screen
Camera live picture signal output: full screen (can be set in (MONITOR SET) menu to display the same image as monitor 1)
per this manufacturer specifications)
Display, Alarm data
continuously
Can be set using a menu to operate automatically when there is an alarm trigger
In full screen mode can switch from frozen to zoomed in picture
Products are subject to change in design and specifications without notice and without incurring any obligation.
English 53
Page 55
SANYO Electric Co., Ltd.
1AC6P1P2015-- L8FL5/XE, UK (0120KP-NI01) Printed in Japan
Loading...