No. 5734-2/13
LA75691
Parameter Symbol Conditions Ratings Unit
Maximum supply voltage V
CC
max 13.2 V
Circuit voltage V13, V17 V
CC
V
I6 –3 mA
Circuit current I10 –10 mA
I24 –2 mA
Allowable power dissipation Pd max Ta ≤ 68°C 720 mW
Operating temperature Topr –20 to +70 °C
Storage temperature Tstg –55 to +150 °C
Note: When mounted on a 65 × 72 × 1.6 mm laminated paper phenolic resin printed circuit board.
Specifications
Maximum Ratings at Ta = 25°C
Parameter Symbol Conditions
Ratings
Unit
min typ max
[VIF Block]
Circuit current I
5
35.5 42.0 48.5 V
Maximum RF AGC voltage V
14H
7.5 8.1 V
Minimum RF AGC voltage V
14L
0 0.5 V
Input sensitivity V
IN
S1 = Off 24 30 36 dBµV
AGC range G
R
62 68 dB
Maximum allowable input V
IN
max 92 97 dBµV
No-signal video output voltage V
6
3.5 3.8 4.2 V
Synchronizing signal tip voltage V
6
tip 1.15 1.45 1.74 V
Video output level V
O
1.7 2.0 2.3 Vp-p
Black noise threshold voltage V
BTH
0.5 0.8 1.1 V
Black noise clamp voltage V
BCL
2.5 2.8 3.1 V
Video signal-to-noise ratio S/N 48 50 dB
C-S beating IC-S 38 43 dB
Frequency characteristics f
C
6 MHz –3.0 –1.5 dB
Differential gain DG 3.0 6.5 %
Differential phase DP 3 5 deg
Maximum AFT voltage V
13H
8.5 8.7 9.0 V
Minimum AFT voltage V
13L
0 0.18 0.5 V
AFT detection sensitivity Sf 22.4 28.0 33.6 mV/kHz
VIF input resistance Ri 38.9 MHz 1.5 kΩ
VIF input capacitance Ci 38.9 MHz 3 pF
APC pull-in range (U) f
PU
0.8 1.3 MHz
APC pull-in range (L) f
PL
–1.5 –0.8 MHz
AFT frequency tolerances 1 dfa 1 –300 0 +300 kHz
VCO1 maximum variability range (U) dfu 1.0 1.3 MHz
VCO1 maximum variability range (L) dfl –1.5 –1.0 MHz
VCO control sensitivity B 1.4 2.8 5.6 kHz/mV
5.5 MHZ output level S
O
P/S = 14 dB 92 95 98 mVrms
[SIF Block]
Limiting voltage Vi (lim) 5.5 MHz ± 30 kHz 43 48 53 dBµV
FM detector output voltage V
O
(FM) 5.5 MHz ± 30 kHz 720 900 1100 mVrms
AM rejection ratio AMR AM = 30 % 50 60 dB
Total harmonic distortion THD 0.3 0.8 %
SIF signal-to-noise ratio S/N (FM) 57 62 dB
Operating Characteristics at Ta = 25°C, VCC= 9 V, fP= 38.9 MHz
Parameter Symbol Conditions Ratings Unit
Recommended supply voltage V
CC
9 V
Operating supply voltage range V
CC
op 8.5 to 12.5 V
Operating Conditions