Typical Characteristics
H
Cell Type CR2016
Specifications
Nominal Capac ity
Nominal Voltage
Standard Discharge Current
Max. Discharge Current
Temperature Range
Weight
Dimensions
Nominal capacity is determined to an end voltage of 2.0V when the battery is
*1
allowed to discharge at a standard current level at 23oC.
Current value is determined to be the level at which 50% of the nominal
*2
capacity is obtained with an end voltage of 2.0V at 23
Current value for obtaining 2.0V cell voltage when pulse is applied for
*3
15seconds at 50% discharge depth at 23
*1
80mAh
3V
0.3mA
Continuous
Pulse
*2
*3
5mA
50mA
-20
℃~70℃
1.7g
D 20.0mm
H1.6mm
d 16.9mm
o
C.
o
C.
Discharge Characteristics of CR2016
3.5
23oC
0oC
180
Duration(hour)
240
300
Cell Voltage(V)
3.0
2.5
2.0
1.5
1.0
0
60
120
Discharge Characteristics of CR2016
3.5
3.0
2.5
Cell Voltage(V)
Initial
0
60
after 100days storage at 70
120
2.0
1.5
1.0
o
C
180
240
Duration(hour)
300
360
360
Load:15kohm(=190uA)
420
480
Load:15kohm(=190uA)
o
Temp.:23
C
420
480
Discharge Characteristics of CR2016
3.5
3.0
2.5
2.0
Cell Voltage(V)
1.5
1.0
540
600
0
o
C
23oC
-20oC
50
100
150
200
250
Duration(day)
Load:270kohm(=10uA)70
300
350
400
450
500
Discharge Load vs. Capacity of CR2016
120
100
80
60
40
Capacity(mAh)
20
540
600
0
70oC
0oC
23oC
0.5
1
-20oC
5
10
Discharge Load (kohm)
50
end voltage:2.0V
100
500